Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “location map”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Pulmonary artery location during microgravity activity: Potential impact for chest-mounted Doppler during space travel

Doppler, or ultrasonic, monitoring for pain manifestations of decompression sickness (the bends) is accomplished by placing a sensor on the chest over the pulmonary artery and listening for bubbles. Difficulties have arisen because the technician notes that the pulmonary artery seems to move with subject movement in a one-g field and because the sensor output is influenced by only slight degrees of sensor movement. This study used two subjects and mapped the position of the pulmonary artery in one-g, microgravity, and two-g environments using ultrasound. The results showed that the pulmonary artery is fixed in location in microgravity and not affected by subject position change. The optimal position corresponded to where the Doppler signal is best heard with the subject in a supine position in a one-g environment. The impact of this result is that a proposed multiple sensor array on the chest proposed for microgravity use may not be necessary to monitor an astronaut during extravehicular activities. Instead, a single sensor of approximately 1 inch diameter and mounted in the position described above may suffice.

Hadley, A. T., III↗

In-Situ Detection of Process-Induced Porosity During Cure of Out-of-Autoclave Composites

Composite materials offer unique benefits in aerospace applications, including high strength-to-weight ratio, and are becoming increasingly used by industry manufacturers. Current manufacturing and processing methods can lead to defects in the composites, which are identified after fabrication using inspection methods. This study utilized a high-temperature ultrasonic inspection system to detect process-induced porosity in an out-of-autoclave (OOA) composite panel during cure. In order to perform ultrasonic scans in-situ during cure, the system needed to be able to operate at oven temperatures up to 200 °C. There are no commercially available ultrasonic scanning systems that can operate continuously at these temperatures, so an enclosure was fabricated to insulate the ultrasonic system in the curing oven. The enclosure housed a MISTRAS® motorized X-Y raster scanner and contact transducer (Olympus® X2002). The Olympus® X2002 contact transducer is a continuous high-temperature delay line transducer with a center frequency of 2.25 MHz. In order to prevent the inside of the enclosure from reaching high temperatures, a sparge pipe inside the cooling enclosure was connected to a liquid nitrogen (LN2) tank outside of the oven via insulated hoses. The cooling system was automatically controlled by a temperature controller that was programmed to open a solenoid valve along the hose at 31 ℃ and close at 28 ℃ inside the cooling enclosure. When the solenoid valve was open, LN2 would flow from the LN2 tank and vaporize prior to reaching cooling enclosure. A U-shaped sparge pipe had holes drilled along its length to uniformly introduce cold nitrogen gas into the cooling enclosure. This prevented the motors from ever reaching the maximum desired operating temperature of 38 ℃. In the bottom of the enclosure, the tool plate was placed with the composite facing the outside of the enclosure, exposing it to the temperatures of the oven. The tool plate was 63.5 mm thick borosilicate glass, which was chosen for its low ultrasonic attenuation and moderate thermal conductivity. A thin layer of ultrasonic couplant was placed on the tool plate. The transducer sent and received ultrasonic waves through the tool plate into the composite. A MISTRAS® Remote UT System performed all wave generation, analog to digital conversion, and data acquisition and processing. The transducer was connected directly to the Remote UT System via a high-temperature BNC cable (CD International, RG-316). Polyimide insulated copper wire was used to connect the scanner to a 2-axis motor drive, which was connected to the Remote UT System. The motor drive and Remote UT System were located outside the industrial oven. A diagram of the ultrasonic system is shown in Figure 1. Figure 1: Diagram of ultrasonic in-situ defect detection system. In this study, a porosity gradient was introduced into the carbon fiber reinforced polymer (CFRP) composite through a misfit of the part and caul plate. A 24-ply quasi-isotropic ([0/90, ±45]12S) composite panel was laid up using Newport® AS4C-M/NB321 out-of-autoclave (OOA) plain weave (PW) prepreg (42% resin content, 195 g/m2). The first 16 plies were 203 mm × 203 mm. Ply drops were incorporated into the panel by decreasing the length of plies 17-24. The sizes of each ply are included in Table 1. All plies were centered along their length (x-axis) creating a trapezoidal type cross-section. Table 1: Ply sizes Plies Length (mm) Width (mm) 1-16 203 203 17-18 102 203 19-20 85 203 21-22 68 203 23-24 51 203 A 15-5 stainless steel caul plate (Size: 203 × 203 × 1.2 mm) was placed on the laminate. The composite and caul plate were vacuum bagged to the tool plate. Per the product datasheet, Newport 321 can be cured between 121 °C and 149 °C, depending on service temperature, with a hold for 90-120 minutes. Based on prior thermal testing of the cooling enclosure, the desired composite temperature cycle could be attained when the air temperature of the oven was ramped to 160 °C at a rate of 1.7 °C/min with a 3 hour hold. The extended hold was not necessary to cure the composite, but did allow for additional scans at the cure temperature during preliminary testing. The composite panel was under vacuum pressure for the entire cure cycle. Under vacuum, the caul plate deformed causing high and low pressure regions. The low-pressure regions formed high porosity in the composite part. The ultrasonic data collected showed that the inspection system was able to monitor the evolution of porosity within the composite throughout the cure cycle. Fifty scans of a 203 mm × 51 mm (8 in. × 2 in.) area of the composite were completed throughout the cure cycle. The scan speed was set to 43 mm/s in the x-direction and 36 mm/s in the y-direction, with a 1.0 mm/pixel resolution in both directions. Each scan took approximately five minutes to complete. Figure 2 shows C-scan amplitude data (top view) from one scan during the cure cycle. The color map indicates the maximum amplitude (%) measured with a time gate that contains reflections from the back surface (furthest from the transducer in contact with the caul plate) of the composite. Because porosity in the composite increases the ultrasonic attenuation in the composite part, a higher amplitude (red) indicates low porosity and a lower amplitude (blue) indicates high porosity. The regions where the caul plate was applying increased pressure (center and ends of the panel) resulted in reduced porosity, whereas the ply drop regions had reduced pressure and thus had higher porosity. Figure 2: Amplitude C-scan (top view) of OOA composite from one scan during the 160 °C temperature hold. Higher amplitude (red) indicates low porosity. Lower amplitude (blue) indicates high porosity. A B-scan is a two-dimensional image plotting the ultrasonic signals from a single y-position at every x-location of the composite panel. The travel time (μs) of the ultrasonic wave (representing the through-thickness location) is plotted along the y-axis, and the ultrasonic wave signal is represented as a contour map. Based on the B-scan data, the location of the defects with respect to the composite thickness was able to be determined. The ply drop regions had high porosity near the front (tool plate) surface of the composite (Figure 3). Figure 3: B-scan (cross-section view) of OOA composite from one scan during the 160 °C temperature hold. Using the data obtained from amplitude C-scans and B-scans throughout the cure cycle, the high and low porosity regions within the composite laminate were detected and localized with high spatial resolution. This paper will discuss the evolution of porosity content in the OOA composite during cure. OOA tests aided the transition of this system to an autoclave, which is the primary method of curing aerospace-grade thermoset composites.

Tyler B. Hudson↗

Multi-frequency optical-depth maps and the case for free-free absorption in two compact symmetric radio sources: The CSO candidate J1324 + 4048 and the CSO J0029 + 3457

We obtained dual-polarization very long baseline interferometry observations at six frequencies of the compact symmetric object J0029 + 3457 and the compact symmetric object candidate J1324 + 4048. By comparing the three lower-frequency maps with extrapolations of the high-frequency maps, we produced maps of the optical depth as a function of frequency. The morphology of the optical-depth maps of J1324 + 4048 is strikingly smooth, suggestive of a foreground screen of absorbing gas. The spectra at the intensity peaks fit a simple free-free absorption (FFA) model, with χ{sub ν}{sup 2}≈2, better than a simple synchrotron self-absorption model, in which χ{sub ν}{sup 2}≈3.5--5.5. We conclude that the case for FFA in J1324 + 4048 is strong. The optical-depth maps of J0029 + 3457 exhibit structure, but the morphology does not correlate with that in the intensity maps. The fit of the spectra at the peaks to a simple FFA model yields χ{sub ν}{sup 2}≈1, but because the turnover is gradual, the fit is relatively insensitive to the input parameters. We find that FFA by a thin amount of gas in J0029 + 3457 is likely but not definitive. One compact feature in J0029 + 3457 has an inverted spectrum even at the highest frequencies. We infer this to be the location of the core and estimate an upper limit to the magnetic field of order 3 Gauss at a radius of order 1 pc. In comparison with maps from observations at earlier epochs, no apparent growth in either J1324 + 4048 or J0029 + 3457 is apparent, with upper limits of 0.03 and 0.02 mas yr{sup –1}, corresponding to maximum linear separation speeds of 0.6c and 0.4c.

79 ASTRONOMY AND ASTROPHYSICS↗

Fault Imaging with High-Resolution Seismic Reflection for Earthquake Hazard and Geothermal Resource Assessment in Reno, Nevada

The Truckee Meadows basin is situated adjacent to the Sierra Nevada microplate, on the western boundary of the Walker Lane. Being in the transition zone between a range-front normal fault on the west and northwest-striking right-lateral strike slip faults to the east, there is no absence of faulting in this basin. The Reno- Sparks metropolitan area is located in this basin, and with a signi cant population living here, it is important to know where these faults are. High-resolution seismic reflection surveys are used for the imaging of these faults along the Truckee River, across which only one fault was previously mapped, and in southern Reno near and along Manzanita Lane, where a swarm of short faults has been mapped. The reflection profiles constrain the geometries of these faults, and suggest additional faults not seen before. Used in conjunction with depth to bedrock calculations and gravity measurements, the seismic reflection surveys provide de nitive locations of faults, as well as their orientations. O sets on these faults indicate how active they are, and this in turn has implications for seismic hazard in the area. In addition to seismic hazard, the faults imaged here tell us something about the conduits for geothermal fluid resources in Reno.

15 GEOTHERMAL ENERGY↗

Quantitative Representativeness and Constituency of the Long-Term Agroecosystem Research Network and Analysis of Complementarity with Existing Ecological Networks

Abstract Studies conducted at sites across ecological research networks usually strive to scale their results to larger areas, trying to reach conclusions that are valid throughout larger enclosing regions. Network representativeness and constituency can show how well conditions at sampling locations represent conditions also found elsewhere and can be used to help scale-up results over larger regions. Multivariate statistical methods have been used to design networks and select sites that optimize regional representation, thereby maximizing the value of datasets and research. However, in networks created from already established sites, an immediate challenge is to understand how well existing sites represent the range of environments in the whole area of interest. We performed an analysis to show how well sites in the USDA Long-Term Agroecosystem Research (LTAR) Network represent all agricultural working lands within the conterminous United States (CONUS). Our analysis of 18 LTAR sites, based on 15 climatic and edaphic characteristics, produced maps of representativeness and constituency. Representativeness of the LTAR sites was quantified through an exhaustive pairwise Euclidean distance calculation in multivariate space, between the locations of experiments within each LTAR site and every 1 km cell across the CONUS. Network representativeness is from the perspective of all CONUS locations, but we also considered the perspective from each LTAR site. For every LTAR site, we identified the region that is best represented by that particular site—its constituency—as the set of 1 km grid locations best represented by the environmental drivers at that particular LTAR site. Representativeness shows how well the combination of characteristics at each CONUS location was represented by the LTAR sites’ environments, while constituency shows which LTAR site was the closest match for each location. LTAR representativeness was good across most of the CONUS. Representativeness for croplands was higher than for grazinglands, probably because croplands have more specific environmental criteria. Constituencies resemble ecoregions but have their environmental conditions “centered” on those at particular existing LTAR sites. Constituency of LTAR sites can be used to prioritize the locations of experimental research at or even within particular sites, or to identify the extents that can likely be included when generalizing knowledge across larger regions of the CONUS. Sites with a large constituency have generalist environments, while those with smaller constituency areas have more specialized environmental combinations. These “specialist” sites are the best representatives for smaller, more unusual areas. The potential of sharing complementary sites from the Long-Term Ecological Research (LTER) Network and the National Ecological Observatory Network (NEON) to boost representativeness was also explored. LTAR network representativeness would benefit from borrowing several NEON sites and the Sevilleta LTER site. Later network additions must include such specialist sites that are targeted to represent unique missing environments. While this analysis exhaustively considered principal environmental characteristics related to production on working lands, we did not consider the focal agronomic systems under study, or their socio-economic context.

54 ENVIRONMENTAL SCIENCES↗

Thylakoid-integrated recombinant Hcf106 participates in the chloroplast twin arginine transport system

The chloroplast twin arginine transport (cpTat) system distinguishes itself as a protein transport pathway by translocating fully folded proteins, using the proton-motive force (PMF) as the sole source of energy. The cpTat pathway is evolutionarily conserved with the Tat pathway found in the plasma membrane of many prokaryotes. The cpTat (Escherichia coli) system uses three proteins, Tha4 (TatA),Hcf106 (TatB), and cpTatC (TatC), to form a transient translocase allowing the pas-sage of precursor proteins. Briefly, cpTatC and Hcf106, with Tha4, form the initial receptor complex responsible for precursor protein recognition and binding in an energy-independent manner, while a separate pool of Tha4 assembles with the pre-cursor-bound receptor complex in the presence the PMF. Analysis by blue-native polyacrylamide gel electrophoresis (BN-PAGE) shows that the receptor complex, in the absence of precursor, migrates near 700 kDa and contains cpTatC and Hcf106with little Tha4 remaining after detergent solubilization. To investigate the role thatHcf106 may play in receptor complex oligomerization and/or stability, systematic cysteine substitutions were made in positions from the N-terminal transmembrane domain to the end of the predicted amphipathic helix of the protein. BN-PAGE analysis allowed us to identify the locations of amino acids in Hcf106 that were critical for interacting with cpTatC. Oxidative cross-linking allowed us to map interactions of the transmembrane domain and amphipathic helix region of Hcf106. In addition, we showed that in vitro expressed, integrated Hcf106 can interact with the precursor signal peptide domain and imported cpTatC, strongly suggesting that a subpopulation of the integrated Hcf106 is participating in competent cpTat complexes.

59 BASIC BIOLOGICAL SCIENCES↗

Fate of cellulose in primary and secondary treatment at municipal water resource recovery facilities

Abstract Cellulose from toilet paper is a significant fraction of particulate organics, which is recoverable. For the first time, comprehensive mapping and tracking the fate of cellulose across various unit processes at full‐scale in two water resource recovery facilities located in North America and Europe was undertaken. The influent cellulose content accounted for approximately one‐third of the total suspended solids (TSS). Although about 80% of the raw wastewater cellulose was removed in primary treatment, the type of primary treatment process (rotating belt filter [RBF] vs. primary clarification [PC]) had a significant impact on cellulose capture and diversion. The high cellulose content of the RBF sludge accounting for 35% of the TSS facilitates cellulose recovery. For the North American plant, with a conventional activated sludge process (SRT of 6–7 days, preceded by PC), cellulose biodegradation efficiencies of 70%–90% of the PC effluent were observed in summer and winter. For the European plant, with a modified University of Cape Town process (SRT of 14 days, without primary treatment in train 2, or preceded by RBF in train 1), comparable cellulose biodegradation efficiencies were also observed. Results from laboratory SBRs indicated that cellulose biodegradation efficiency at room temperature was 86% of the influent cellulose. Practitioner points Cellulose fate was tracked across two different WWTPs in two different geographies. Cellulose in the influent wastewater accounted for 1/3 of the total suspended solids. Primary treatments were able to capture more than 80% of the influent cellulose. Cellulose was biodegraded in secondary treatment, resulting an effluent of 2–3 mg/L.

Ahmed, Ahmed Shawki↗

The GlueX Experiment: First Results

GlueX is a nuclear physics experiment located at the Thomas Jefferson National Accelerator Facility designed to study and understand the nature of confinement in QCD by mapping the spectrum of exotic mesons. The experiment will be able to probe new areas by using photoproduction, i.e. the scattering on nucleon of ~9 GeV linearly polarized photons derived from the recently upgraded CEBAF with a 12 GeV electron beam. Spring 2016 has been characterized by a continued detector commissioning and initial running at the full design energy. The current status of the GlueX detector performance and data collection will be discussed, with a brief overview of first physics results, future run plans, and long term upgrades.

Fanelli, Cristiano (ORCID:0000000219851329)↗

A Geo-Data Science Method for Assessing Unconventional Rare-Earth Element Resources in Sedimentary Systems

Abstract Rare-earth elements (REEs) supply raw materials that constitute many of our modern critical infrastructure, defense, technology, and electrification needs. Despite REE accumulations occurring in conventional bedrock and ion-adsorption deposits sourced from weathering of igneous rocks, unconventional host materials such as coal and related sedimentary strata have been identified as promising sources of REEs to meet growing demand. To maximize the potential of unconventional resources such as REE-coal systems, new approaches are needed overcome challenges from mineral systems with no known deposits and areas with sparse geochemical data. This article presents a systematic knowledge-data resource assessment method for predicting and identifying REE resource potential and occurrence in these unconventional systems. The method utilizes a geologic and geospatial knowledge-data approach informed and guided by REE accumulation mechanisms to systematically assess and identify areas of higher enrichment. An assessment of the Powder River Basin is presented as a test case to demonstrate the method workflow and results. The key output is a potential enrichment score map reported with varying confidence levels based on the amount of supporting evidence. Results from the test case indicate several locations with promising potential for different types of coal-REE deposits, demonstrating the viability of the method for exploration and assessment of unconventional REE resources. The method is flexible by design and, with sufficient applicable knowledge and data, can be adapted for assessing critical mineral systems in other sedimentary systems as well.

58 GEOSCIENCES↗

Crystal structure and electron density in the apatite-type ionic conductor La{sub 9.71}(Si{sub 5.81}Mg{sub 0.18})O{sub 26.37}

Crystal structure and electron density in the apatite-type ionic conductor La{sub 9.71}(Si{sub 5.81}Mg{sub 0.18})O{sub 26.37} have been investigated at 302, 674 and 1010 K by Rietveld refinement and a whole-pattern fitting approach based on the maximum-entropy method (MEM) using synchrotron X-ray powder diffraction data. Second harmonic generation measurements indicated that the space group of this material is centrosymmetric. Among the possible hexagonal groups P6{sub 3}/m, P6{sub 3} and P3-bar the former is correct for La{sub 9.71}(Si{sub 5.81}Mg{sub 0.18})O{sub 26.37}. Rietveld refinements suggested an oxygen interstitial site (0.03,0.15,0.85) near the hexagonal axis. MEM analyses revealed that the Si{sub 0.97}Mg{sub 0.03} atom has covalent bonds with four adjacent oxygen atoms to form a tetrahedron. The oxygen O4 atom located at the 2a site (0.0,0.0,1/4) exhibited large atomic displacement parameters along the c axis and electron density mapping also indicated the wide distribution consistent with migration of oxygen ions in this direction. - Graphical abstract: Equielectron density surfaces at 1.0 A{sup -3} of apatite-type La{sub 9.71}(Si{sub 5.81}Mg{sub 0.18})O{sub 26.37} at 302 K. O4 atoms have large distribution along the <001> direction (white arrows).

36 MATERIALS SCIENCE↗

PROPERTIES OF THE COMPACT H II REGION COMPLEX G-0.02-0.07

We present new extinction maps and high-resolution Paschen-alpha images of G-0.02-0.07, a complex of compact H II regions located adjacent to the M-0.02-0.07 giant molecular cloud, 6 pc in projection from the center of the Galaxy. These H II regions, which lie in projection just outside the boundary of the Sgr A East supernova remnant, represent one of the most recent episodes of star formation in the central parsecs of the Galaxy. The 1.87 {mu}m extinctions of regions A, B, and C are almost identical, approximately 3.7 mag. Region D, in contrast, has a peak extinction of A{sub 1.87} = 5.9 mag. Adopting an extinction law specific to the Galactic center, we find that these extinctions correspond to visual extinctions of A{sub V} = 45 and A{sub V} = 71. The similar and uniform extinctions of regions A, B, and C are consistent with that expected for foreground extinction in the direction of the Galactic center, suggesting that they lie at the front side of the M-0.02-0.07 molecular cloud. Region D is more compact, has a higher extinction, and is thus suspected to be younger and embedded in a dense core in a compressed ridge on the western edge of this cloud.

79 ASTRONOMY AND ASTROPHYSICS↗

EVIDENCE FOR CLOUD-CLOUD COLLISION AND PARSEC-SCALE STELLAR FEEDBACK WITHIN THE L1641-N REGION

We present high spatial resolution {sup 12}CO (J = 1-0) images taken by the Nobeyama 45 m telescope toward a 48' Multiplication-Sign 48' area, including the L1641-N cluster. The effective spatial resolution of the maps is 21'', corresponding to 0.04 pc at a distance of 400 pc. A recent 1.1 mm dust continuum map reveals that the dense gas is concentrated in several thin filaments. We find that a few dust filaments are located at the parts where {sup 12}CO (J = 1-0) emission drops sharply. Furthermore, the filaments have two components with different velocities. The velocity difference between the two components is about 3 km s{sup -1}, corresponding to a Mach number of 10, significantly larger than the local turbulent velocity in the cloud. These facts imply that the collision of the two components (hereafter, the cloud-cloud collision) possibly contributed to the formation of these filaments. Since the two components appear to overlap toward the filaments on the plane of the sky, the collision may have occurred almost along the line of sight. Star formation in the L1641-N cluster was probably triggered by such a collision. We also find several parsec-scale CO shells whose centers are close to either the L1641-N cluster or the V 380 Ori cluster. We propose that these shells were created by multiple winds and/or outflows from cluster young stellar objects, i.e., 'protocluster winds'. One exceptional dust filament located at the western cloud edge lies along a shell; it is presumably part of the expanding shell. Both the cloud-cloud collision and protocluster winds are likely to influence the cloud structure and kinematics in this region.

79 ASTRONOMY AND ASTROPHYSICS↗

Low- n stability and plasma response to RMP in various STEP scenarios

The low-n (n is the toroidal mode number) magnetohydrodynamic (MHD) stability and plasma response are numerically investigated for various scenarios designed for STEP, that are relevant for the H-mode pedestal analysis. Control of the edge-localized modes (ELMs) with externally applied resonant magnetic perturbations (RMPs) is considered. Optimization of the ELM control coil current configuration, based on the computed plasma MHD response and well-established figures of merit validated on present-day experiments, finds reasonable robustness of a fixed coil phasing (for a given n-number) to control ELMs in all five STEP plasmas considered. Based on certain semi-empirical criteria, the required coil current to achieve ELM suppression is estimated to be about 10–20 kAt with the n = 1 or 2 RMP configuration and about 100–200 kAt for the n = 4 RMP. Systematic linear stability calculations are used to map out stability windows for the low-n kink-peeling modes, in terms of the ideal-wall location and variation of the edge safety factor q 95 with respect to the target design. The kink-peeling stability boundary is found to be generally sensitive to the q 95 variation, which has implications for achieving the quiescent H-mode regime in STEP. Full toroidal quasilinear initial-value simulations for these STEP plasmas find that generation of the edge-harmonic oscillations (EHOs) depends sensitively on the plasma scenario, the initial linear stability of the kink-peeling modes, the initial plasma toroidal flow and q 95 . In general, it is easier (more robust) to access the EHO-regime for two of the cases considered with smaller plasma volume and higher on-axis safety factor. Finally, quasilinear simulations find robust density pumpout due to applied RMPs in these STEP plasmas, but the effect on the plasma toroidal flow varies among different cases.

EHO↗

Robotic path-finding in inverse treatment planning for stereotactic radiosurgery with continuous dose delivery

Purpose: Continuous dose delivery in radiation therapy treatments has been shown to decrease total treatment time while improving the dose conformity and distribution homogeneity over the conventional step-and-shoot approach. The authors develop an inverse treatment planning method for Gamma Knife® Perfexion™ that continuously delivers dose along a path in the target. Methods: The authors’ method is comprised of two steps: find a path within the target, then solve a mixed integer optimization model to find the optimal collimator configurations and durations along the selected path. Robotic path-finding techniques, specifically, simultaneous localization and mapping (SLAM) using an extended Kalman filter, are used to obtain a path that travels sufficiently close to selected isocentre locations. SLAM is novelly extended to explore a 3D, discrete environment, which is the target discretized into voxels. Further novel extensions are incorporated into the steering mechanism to account for target geometry. Results: The SLAM method was tested on seven clinical cases and compared to clinical, Hamiltonian path continuous delivery, and inverse step-and-shoot treatment plans. The SLAM approach improved dose metrics compared to the clinical plans and Hamiltonian path continuous delivery plans. Beam-on times improved over clinical plans, and had mixed performance compared to Hamiltonian path continuous plans. The SLAM method is also shown to be robust to path selection inaccuracies, isocentre selection, and dose distribution. Conclusions: The SLAM method for continuous delivery provides decreased total treatment time and increased treatment quality compared to both clinical and inverse step-and-shoot plans, and outperforms existing path methods in treatment quality. It also accounts for uncertainty in treatment planning by accommodating inaccuracies.

60 APPLIED LIFE SCIENCES↗

Activity Characterization for Modeling Behavioral-driven Human Mobility in Platial Networks

The population is increasingly becoming tractable as more and more people carry handheld devices as part of their everyday activities. Recent studies have shown that handheld devices' generated traffic share is now more than 50% of total global online traffic. This has created an unprecedented opportunity for modeling human mobility behavior. For example, aggregate check-ins and dwell time can reveal building level occupancies. However, there are clear limits to accurate modeling (e.g. reproducible, repeatable, and realistic), unless we decipher the underlying reason causing typical mobility patterns. We know that human behavior is a reflection of a set of activities, such as going to the gym or work, and which can be seen as a catalyst for humans to move from one location to another. This work envisions the use of activity characterization for modeling human mobility by introducing a context that maps activities to certain mobility patterns. In the end, we highlight the efficacy of the proposed approach by analyzing the impact of public policies surrounding stay at home order on human mobility.

Thakur, Gautam Malviya↗

Snake River Plain FORGE: Site Characterization Data

The site characterization data used to develop the conceptual geologic model for the Snake River Plain site in Idaho, as part of phase 1 of the Frontier Observatory for Research in Geothermal Energy (FORGE) initiative. This collection includes data on seismic events, groundwater, geomechanical models, gravity surveys, magnetics, resistivity, magnetotellurics (MT), rock physics, stress, the geologic setting, and supporting documentation, including several papers. Also included are 3D models (Petrel and Jewelsuite) of the proposed site. Data for wells INEL-1, WO-2, and USGS-142 have been included as links to separate data collections. These data have been assembled by the Snake River Geothermal Consortium (SRGC), a team of collaborators that includes members from national laboratories, universities, industry, and federal agencies, lead by the Idaho National Laboratory (INL). Other contributors include the National Renewable Energy Laboratory (NREL), Lawrence Livermore National Laboratory (LLNL), the Center for Advanced Energy Studies (CEAS), the University of Idaho, Idaho State University, Boise State University, University of Wyoming, University of Oklahoma, Energy and Geoscience Institute-University of Utah, US Geothermal, Baker Hughes Campbell Scientific Inc., Chena Power, US Geological Survey (USGS), Idaho Department of Water Resources, Idaho Geological Survey, and Mink GeoHydro.

15 GEOTHERMAL ENERGY↗

PDC IC Weld Failure Evaluation and Resolution

During final preparations for start of the PDCF Inner Can (IC) qualification effort, welding was performed on an automated weld system known as the PICN. During the initial weld, using a pedigree canister and plug, a weld defect was observed. The defect resulted in a hole in the sidewall of the canister, and it was observed that the plug sidewall had not been consumed. This was a new type of failure not seen during development and production of legacy Bagless Transfer Cans (FB-Line/Hanford). Therefore, a team was assembled to determine the root cause and to determine if the process could be improved. After several brain storming sessions (MS and T, R and D Engineering, PDC Project), an evaluation matrix was established to direct this effort. The matrix identified numerous activities that could be taken and then prioritized those activities. This effort was limited by both time and resources (the number of canisters and plugs available for testing was limited). A discovery process was initiated to evaluate the Vendor's IC fabrication process relative to legacy processes. There were no significant findings, however, some information regarding forging/anneal processes could not be obtained. Evaluations were conducted to compare mechanical properties of the PDC canisters relative to the legacy canisters. Some differences were identified, but mechanical properties were determined to be consistent with legacy materials. A number of process changes were also evaluated. A heat treatment procedure was established that could reduce the magnetic characteristics to levels similar to the legacy materials. An in-situ arc annealing process was developed that resulted in improved weld characteristics for test articles. Also several tack welds configurations were addressed, it was found that increasing the number of tack welds (and changing the sequence) resulted in decreased can to plug gaps and a more stable weld for test articles. Incorporating all of the process improvements for the actual can welding process, however, did not result in an improved weld geometry. Several possibilities for the lack of positive response exist, some of which are that (1) an insufficient number of test articles were welded under prototypic conditions, (2) the process was not optimized so that significant improvements were observable over the "noise", and (3) the in-situ arc anneal closed the gap down too much so the can was unable to exhaust pressure ahead of the weld. Several operational and mechanical improvements were identified. The weld clamps were changed to a design consistent with those used in the legacy operations. A helium puff operation was eliminated; it is believed that this operation was the cause of the original weld defect. Also, timing of plug mast movement was found to correspond with weld irregularities. The timing of the movement was changed to occur during weld head travel between tacks. In the end a three sequential tack weld process followed by a pulse weld at the same current and travel speed as was used for the legacy processes was suggested for use during the IC qualification effort. Relative to legacy welds, the PDC IC weld demonstrates greater fluctuation in the region of the weld located between tack welds. However, canister weld response (canister to canister) is consistent and with the aid of the optical mapping system (for targeting the cut position) is considered adequate. DR measurements and METs show the PDC IC welds to have sufficient ligament length to ensure adequate canister pressure/impact capacity and to ensure adequate stub function. The PDC welding process has not been optimized as a result of this effort. Differences remain between the legacy BTC welds and the PDC IC weld, but these differences are not sufficient to prevent resumption of the current PDC IC qualification effort. During the PDC IC qualification effort, a total of 17 cans will be welded and a variety of tests/inspections will be performed. The extensive data collected during that qualification effort should be of a sufficient population to determine if additional weld process optimization is necessary prior to production release.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Innovative Exploration Techniques for Geothermal Assessment at Jemez Pueblo, New Mexico

Surface exploration methods like geological mapping, mineralogical analysis, hydrogeochemistry, magnetotelluric as well as seismic, have been used to analyze the study area and identify a location for a production size exploration well. After that location has been identified in a blind resource scenario, a 5,657 feet deep deviated production size exploration well has been drilled. The surface casing is 13 3/8 inch with open hole starting at 4,136 feet. The well has been designed to be deepened up to 8,000 feet if needed. The first 4,180 feet have been sufficiently analyzed and were considered only of direct use interest prior to drilling. That has been confirmed. The remaining depth couldn't be logged by the time the report has been submitted because the well had an obstruction at 4,180 feet. Currently the power production potential for the drilling location cannot be determined without additional work-over of the well. The seismic conducted prior to drilling was a 100% success, providing a clear image of the subsurface and allowing for geosteering to be fact based and on target. Once the obstruction has been removed, work can continue to determine the power generation potential at that location.

15 GEOTHERMAL ENERGY↗