Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Acoustic characterization of sensors used for marine environmental monitoring

We report active acoustic sensors are widely used in oceanographic and environmental studies. Although many have nominal operating frequencies above the range of marine mammal hearing, they can produce out-of-band sound that may be audible to marine mammals. Acoustic emissions from four active acoustic transducers were characterized and compared to marine mammal hearing thresholds. All four transducers had nominal operating frequencies above the reported upper limit of marine mammal hearing, but produced measurable sound below 160 kHz. A spatial map of the acoustic emissions of each sonar is used to evaluate potential effects on marine mammal hearing when the transducer is continuously operated from a stationary platform. Based on the cumulative sound exposure level metric, the acoustic emissions from the transducers are unlikely to cause temporary threshold shifts in marine mammals, but could affect animal behavior. The extent of audibility is estimated to be, at most, on the order of 100 m.

47 OTHER INSTRUMENTATION↗

Application of Advanced Metering Infrastructure Data to Advanced Utility System Operations: Cooperative Research and Development, CRADA Number CRD-17-00712 (Final Report)

The primary objective of the proposed project is to evaluate the capabilities of Advanced Metering Infrastructure (AMI) based controls for grid operations. This includes monitoring and control at the secondary transformer level using existing AMI infrastructure. In addition, some of the challenges of using a model-less control will also be identified. The lessons learned will be disseminated to other utilities around the country through peer-reviewed publications with the consent of SDG&E. The scope of the work includes using data from SDG&E's existing AMI infrastructure and working with third party vendors selected by SDG&E. The grid edge monitoring systems and controls provided by the selected vendors will perform grid operations using AMI data. The National Renewable Energy Laboratory (NREL) will perform a software and controller-based evaluation of the grid edge controller, intelligent devices and sensors, at the Energy System Integration Facility (ESIF) laboratory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Review of Radio Frequency Interference and Potential Impacts on the CMB-S4 Cosmic Microwave Background Survey

CMB-S4 will map the cosmic microwave background to unprecedented precision, while simultaneously surveying the millimeter-wave time-domain sky, in order to advance our understanding of cosmology and the universe. CMB-S4 will observe from two sites, the South Pole and the Atacama Desert of Chile. A combination of small- and large-aperture telescopes with hundreds of thousands of polarization-sensitive detectors will observe in several frequency bands from 20-300 GHz, surveying more than 50% of the sky to arcminute resolution with unprecedented sensitivity. CMB-54 seeks to make a dramatic leap in sensitivity while observing across a broad range of largely unprotected spectrum which is increasingly being utilized for terrestrial and satellite transmissions. Fundamental aspects of CMB instrument technology leave them vulnerable to radio frequency interference (RFI) across a wide range of frequencies, including frequencies outside of their observing bands. Ground-based CMB instruments achieve their extraordinary sensitivities by deploying large focal planes of superconducting bolometers to extremely dry, high-altitude sites, with large fractional bandwidths, wide fields of view, and years of integration time. Suitable observing sites have historically offered significant protection from RFI, both naturally through their extremely remote locations as well as through restrictions on local emissions. Since the coupling mechanisms are complex, "safe" levels or frequencies of emission that would not interfere with CMB measurements cannot always be determined through straightforward calculations. We discuss models of interference for various types of RFI relevant to CMB-54, mitigation strategies, and the potential impacts on survey sensitivity.

Cosmic Microwave Background↗

Coordination Changes And Auto-Hydroxylation of FIH-1: Uncoupled O(2)-Activa in a Human Hypoxia Sensor

Hypoxia sensing is the generic term for pO2-sensing in humans and other higher organisms. These cellular responses to pO2 are largely controlled by enzymes that belong to the Fe(II) alpha-ketoglutarate (alphaKG) dependent dioxygenase superfamily, including the human enzyme called the factor inhibiting HIF (FIH-1), which couples O2-activation to the hydroxylation of the hypoxia inducible factor alpha (HIFalpha). Uncoupled O2-activation by human FIH-1 was studied by exposing the resting form of FIH-1 (alphaKG + Fe)FIH-1, to air in the absence of HIFalpha. Uncoupling lead to two distinct enzyme oxidations, one a purple chromophore (lambda(max) = 583 nm) arising from enzyme auto-hydroxylation of Trp296, forming an Fe(III)-O-Trp296 chromophore [Y.-H. Chen, L.M. Comeaux, S.J. Eyles, M.J. Knapp, Chem. Commun. (2008), doi:10.1039/B809099H]; the other a yellow chromophore due to Fe(III) in the active site, which under some conditions also contained variable levels of an oxygenated surface residue (oxo)Met275. The kinetics of purple FIH-1 formation were independent of Fe(II) and alphaKG concentrations, however, product yield was saturable with increasing [alphaKG] and required excess Fe(II). Yellow FIH-1 was formed from (succinate+Fe)FIH-1, or by glycerol addition to (alphaKG+Fe)FIH-1, suggesting that glycerol could intercept the active oxidant from the FIH-1 active site and prevent hydroxylation. Both purple and yellow FIH-1 contained high-spin, rhombic Fe(III) centers, as shown by low temperature EPR. XAS indicated distorted octahedral Fe(III) geometries, with subtle differences in inner-shell ligands for yellow and purple FIH-1. EPR of Co(II)-substituted FIH-1 (alphaKG + Co)FIH-1, indicated a mixture of 5-coordinate and 6-coordinate enzyme forms, suggesting that resting FIH-1 can readily undergo uncoupled O2-activation by loss of an H2O ligand from the metal center.

54 ENVIRONMENTAL SCIENCES↗

Electrochemical techniques and mechanisms for the corrosion of metals and alloys in sub- and supercritical aqueous systems

Corrosion has become a decisive factor hindering supercritical water technologies' long-cycle, safe implementation. Electrochemical experiments performed in supercritical aqueous systems can capture essential, real-time information about the micro/nanoscale processes of corrosion and their kinetics. As a starting point, this paper first summarizes the critical chemical properties of supercritical aqueous systems and analyzes their role in determining the duality of corrosion mechanisms (whether electrochemical or chemical micro-processes predominate). Next, it reviews the available electrochemical techniques such as pH sensors, electrochemical noise measurements, and related applications for quantitatively elaborating the corrosion issues in supercritical aqueous systems. With thick and heavy colors, a series of mechanistic models, such as the mixed potential model and the coupled environment models were introduced from the fundamental theories to the related applications, which have been applied widely in ambient and subcritical aqueous systems and exhibit great values and potential to be employed in high-density supercritical water environments. The passivity, depassivation, and passivity breakdown of metals and alloys in terms of the Point Defect Model (PDM) were also successfully implemented and discussed. Further, the newly built SCW_PDM describes the film growth kinetics at the atomic level of metals and alloys in supercritical water and is being developed to quantitatively analyze and resolve a series of corrosion issues such as the passivity breakdown and the stress corrosion cracking that occur in supercritical aqueous systems. This review is helpful by promoting the development of the electrochemical corrosion theory in supercritical aqueous systems and by identifying corrosion prevention and control methods for the safe implementation of relevant supercritical water technologies.

36 MATERIALS SCIENCE↗

Field data collection of miscellaneous electrical loads in Northern California: Initial results

This report describes efforts to measure energy use of miscellaneous electrical loads (MELs) in 880 San Francisco Bay Area homes during the summer of 2012. Ten regions were selected for metering: Antioch, Berkeley, Fremont, Livermore, Marin County (San Rafael, Novato, Fairfax, and Mill Valley), Oakland/Emeryville, Pleasanton, Richmond, San Leandro, and Union City. The project focused on three major categories of devices: entertainment (game consoles, set-top boxes, televisions and video players), home office (computers, monitors and network equipment), and kitchen plug-loads (coffee/espresso makers, microwave ovens/toaster ovens/toasters, rice/slow cookers and wine chillers). These categories were important to meter because they either dominated the estimated overall energy use of MELs, are rapidly changing, or there are very little energy consumption data published. A total of 1,176 energy meters and 143 other sensors were deployed, and 90% of these meters and sensors were retrieved. After data cleaning, we obtained 711 valid device energy use measurements, which were used to estimate, for a number of device subcategories, the average time spent in high power, low power and “off” modes, the average energy use in each mode, and the average overall energy use. Consistent with observations made in previous studies, we find on average that information technology (IT) devices (home entertainment and home office equipment) consume more energy (15.0 and 13.0 W, respectively) than non-IT devices (kitchen plug-loads; 4.9 W). Opportunities for energy savings were identified in almost every device category, based on the time spent in various modes and/or the power levels consumed in those modes. Future reports will analyze the collected data in detail by device category and compare results to those obtained from prior studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ammonium Fluoride Passivation of CdZnTeSe Sensors for Applications in Nuclear Detection and Medical Imaging

Cadmium zinc telluride selenide (Cd1−xZnxTe1−ySey or CZTS) is one of the emerging CdTe-based semiconductor materials for detecting X- and gamma-ray radiation at or near room temperature (i.e., without cryogenic cooling). Potential applications of CZTS sensors include medical imaging, X-ray detection, and gamma-ray spectroscopy. Chemical passivation of CZTS is needed to reduce the conductivity of Te-rich surfaces, which reduces the noise and improves the device performance. In this study, we focus on the effect of surface passivation of CZTS using a 10% aqueous solution of ammonium fluoride. The effects of the chemical treatment were studied on the leakage current, charge transport measured as the electron mobility-lifetime (µτ) product, and the spectral resolution measured as the full-width at half-maximum (FWHM) of specific peaks. After passivation, the leakage current increased and began to decrease towards pre-passivation levels. The energy resolutions were recorded for eight applied voltages between −35 V and −200 V. The results showed an average of 25% improvement in the detector’s energy resolution for the 59.6 keV gamma peak of Am-241. The electron µτ product was unchanged at 2 × 10−3 cm2/V. These results show that ammonium fluoride is effective for chemical passivation of CZTS detectors.

36 MATERIALS SCIENCE↗

Validation of an inverse model of zone air heat balance

Our work introduces the validation method and results of an inverse model of zone air heat balance. The inverse model, implemented in EnergyPlus and published in a previous article [1], calculates highly uncertain model parameters such as internal thermal mass and infiltration airflow by inversely solving the zone air heat balance equation using the easy-to-measure zone air temperature data. The paper provides technical details of validation from the experiments using LBNL's Facility for Low Energy eXperiment in Buildings (FLEXLAB) that measures zone air temperature under the controlled experiment of two levels of internal mass and four levels of infiltration airflow. The simulation results of the zone infiltration airflow and internal thermal mass from the inverse model agree well with the measured data from the FLEXLAB experiments. The validated inverse model in EnergyPlus can be utilized to enhance the energy modeling of existing buildings that enables energy performance assessments for energy efficiency improvements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ICAM-1 and AMPK regulate cell detachment and apoptosis by N-methyl-N Prime -nitro-N-nitrosoguanidine, a widely spread environmental chemical, in human hormone-refractory prostate cancers

Poly(ADP-ribose) polymerase-1 (PARP-1), a sensor of DNA damage, plays a crucial role in the regulation of DNA repair. PARP-1 hyperactivation causes DNA damage and cell death. The underlying mechanism is complicated and is through diverse pathways. The understanding of responsible signaling pathways may offer implications for effective therapies. After concentration-response determination of N-Methyl-N Prime -Nitro-N-Nitrosoguanidine (MNNG, a PARP-1 activating agent and an environmental mutagen) in human hormone-refractory prostate cancers, the data showed that concentrations below 5 {mu}M did not change cell survival but cause a time-dependent up-regulation of intracellular adhesion molecule-1 (ICAM-1) in mRNA, total protein and cell surface levels. Detection of phosphorylation and degradation of I{kappa}B-{alpha} and nuclear translocation of NF-{kappa}B showed that MNNG induced the activation of NF-{kappa}B that was responsible for the ICAM-1 up-regulation since PDTC (a NF-{kappa}B inhibitor) significantly abolished this effect. However, higher concentrations (e.g., 10 {mu}M) of MNNG induced a 61% detachment of the cells which were apoptosis associated with the activation of AMP-activated protein kinase (AMPK), c-Jun N-terminal kinase (JNK) and p38 mitogen-activated protein kinase (MAPK). Further identification showed that both AMPK and JNK other than p38 MAPK functionally contributed to cell death. The remaining 39% attached cells were survival associated with high ICAM-1 expression. In conclusion, the data suggest that NF-{kappa}B-dependent up-regulation of ICAM-1 plays a key role on cell attachment and survival; whereas, activation of AMPK and JNK participates in cytotoxic signaling pathways in detached cells caused by PARP-1 activation. Highlights: Black-Right-Pointing-Pointer Low level of DNA damage helps cell attachment and survival via ICAM-1 upregulation. Black-Right-Pointing-Pointer High level of DNA damage causes AMPK- and JNK-involved cell detachment and death. Black-Right-Pointing-Pointer The study provides an anticancer approach targeting PARP-1 and DNA damage response.

60 APPLIED LIFE SCIENCES↗

NDX: Neutron Dose Rate Meters with Extended Capabilities

Particle accelerators, irradiation facilities, and nuclear power plants would benefit from using neutron dose rate meters featuring improved energy response covering full range of expected neutron energies, improved dynamic range of measured dose rates while providing the real-time data, and improved ability to operate in harsh radiation environments including heavy photon backgrounds and pulsed beams. The novel design of the neutron moderator for the NDX dose rate meter implements a layer of a Beryllium-loaded medium Z material which, similar to the earlier known WENDI detectors, allows the device to detect higher energy neutron flux and convert it to dose. Using Beryllium helps to fill the known dip in the response functions around 5-50 MeV. Optimized design parameter set, obtained using FLUKA Monte Carlo simulations, features the NDX moderator made of polyethylene embedding a layer of BeCu alloy inside, with the dose rate response constant within ±10% in the neutron energy range from about 100 keV to 500 MeV, and ±25% essentially in the full energy range above thermal. A new sensor technique implemented in the NDX is based on using the Ionization Chamber (IC) filled with 3He gas to capture the moderated neutron fluence, and includes a symmetric IC filled with regular 4He to evaluate the contributions due to the non-neutron ionizing radiation. Advantages of the method include large accessible dynamic range, relative insensitivity of the IC probes to photon radiation fields, and the ability to subtract their contribution. Two prototype NDX detectors were built, calibrated, and operated in various conditions at the CEBAF 12 GeV electron accelerator at JLab. The first results showed reliable neutron dose rate measurements in the presence of overwhelming photon radiation fields, and at practical high dose rate levels of up to approximately 10 Sv/h. Detector design, operation, first results, and further development plans are presented.

Degtiarenko, Pavel V.↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Stereolithographic Fabrication of a Flow Cell For Improved Neurochemical Sensor Testing

The human brain remains a mystery to researchers. Scientists at Lawrence Livermore National Laboratory (LLNL) have developed highly sensitive and flexible multimodal multielectrode arrays (MEAs) with the potential to be both powerful diagnostic and therapeutic tools when dealing with neurological ailments such as Alzheimers, Parkinson’s, Post Traumatic Stress Disorder, and Traumatic Brain Injuries. These MEAs include biosensors in addition to electrodes for electrical stimulation and recording. The transition from the traditional rigid neural probes to the flexible MEAs has led LLNL researchers on the search for alternative testing and characterization methods for flexible devices in vitro. The rigid devices have been shown to be more abrasive and damaging to the brain when implanted, but due to their rigidity – are more robust and resilient to noise artifacts in in vitro testing. The flexible MEAs, similar in size and flexibility to a human hair, cause much less damage in the brain but have had a difficult time maintaining their integrity and collecting data without high-levels of noise due to the formation of inertial eddies (due to increased turbulent flow) moving the flexible MEA during in vitro testing. The goal of this project was to design a fluidic cell to allow for a more constant electrochemical testing & characterization of biosensors on these flexible MEAs. Design and fabrication of the fluidic cell was through the use of CAD software and a stereolithography printer using clear photopolymer resin (appropriate for biomedical use and quality resolution). Flow cells facilitate analyte delivery to biosensor surfaces in a more constant and controlled fashion, allowing for –in this case –a better electrodeposition of thin-film Platinum-Iridium (Pt-Ir) on MEAs of 16 Platinum disc electrodes 50µm in diameter. Platinum-Iridium alloy electrodes have been widely used in biomedical and industrial applications. Iridium adds mechanical stiffness to platinum. PtIr is a FDA approved electrode material for human implantable devices.

36 MATERIALS SCIENCE↗

Nano-level instrumentation for analyzing the dynamic accuracy of a rolling element bearing

The rotational performance of high-precision rolling bearings is fundamental to the overall accuracy of complex mechanical systems. A nano-level instrument to analyze rotational accuracy of high-precision bearings of machine tools under working conditions was developed. In this instrument, a high-precision (error motion < 0.15 μm) and high-stiffness (2600 N axial loading capacity) aerostatic spindle was applied to spin the test bearing. Operating conditions could be simulated effectively because of the large axial loading capacity. An air-cylinder, controlled by a proportional pressure regulator, was applied to drive an air-bearing subjected to non-contact and precise loaded axial forces. The measurement results on axial loading and rotation constraint with five remaining degrees of freedom were completely unconstrained and uninfluenced by the instrument's structure. Dual capacity displacement sensors with 10 nm resolution were applied to measure the error motion of the spindle using a double-probe error separation method. This enabled the separation of the spindle's error motion from the measurement results of the test bearing which were measured using two orthogonal laser displacement sensors with 5 nm resolution. Finally, a Lissajous figure was used to evaluate the non-repetitive run-out (NRRO) of the bearing at different axial forces and speeds. The measurement results at various axial loadings and speeds showed the standard deviations of the measurements’ repeatability and accuracy were less than 1% and 2%. Future studies will analyze the relationship between geometrical errors and NRRO, such as the ball diameter differences of and the geometrical errors in the grooves of rings.

42 ENGINEERING↗

Chemical and structural analysis of a photoactive vertebrate cryptochrome from pigeon

Computational and biochemical studies implicate the blue-light sensor cryptochrome (CRY) as an endogenous light-dependent magnetosensor enabling migratory birds to navigate using the Earth’s magnetic field. Validation of such a mechanism has been hampered by the absence of structures of vertebrate CRYs that have functional photochemistry. Here we present crystal structures of Columba livia (pigeon) CRY4 that reveal evolutionarily conserved modifications to a sequence of Trp residues (Trp-triad) required for CRY photoreduction. In ClCRY4, the Trp-triad chain is extended to include a fourth Trp (W369) and a Tyr (Y319) residue at the protein surface that imparts an unusually high quantum yield of photoreduction. These results are consistent with observations of night migratory behavior in animals at low light levels and could have implications for photochemical pathways allowing magnetosensing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

WE-D-210-04: Radiation-Induced Polymerization of Ultrasound Contrast Agents in View of Non-Invasive Dosimetry in External Beam Radiation Therapy

Purpose: Ultrasound contrast agents (UCA’s) based on gas-filled microbubbles encapsulated by an amphiphilic shell are well established as safe and effective echo-enhancers in diagnostic imaging. In view of an alternative application of UCA’s, we investigated the use of targeted microbubbles as radiation sensors for external beam radiation therapy. As radiation induces permanent changes in the microbubble’s physico-chemical properties, a robust measure of these changes can provide a direct or indirect estimate of the applied radiation dose. For instance, by analyzing the ultrasonic dispersion characteristics of microbubble distributions before and after radiation treatment, an estimate of the radiation dose at the location of the irradiated volume can be made. To increase the radiation sensitivity of microbubbles, polymerizable diacetylene molecules can be incorporated into the shell. This study focuses on characterizing the acoustic response and quantifying the chemical modifications as a function of radiation dose. Methods: Lipid/diacetylene microbubbles were irradiated with a 6 MV photon beam using dose levels in the range of 0–150 Gy. The acoustic response of the microbubbles was monitored by ultrasonic through-transmission measurements in the range of 500 kHz to 20 MHz, thereby providing the dispersion relations of the phase velocity, attenuation and nonlinear coefficient. In addition, the radiation-induced chemical modifications were quantified using UV-VIS spectroscopy. Results: UV-VIS spectroscopy measurements indicate that ionizing radiation induces the polymerization of diacetylenes incorporated in the microbubble shell. The polymer yield strongly depends on the shell composition and the radiation-dose. The acoustic response is inherently related to the visco-elastic properties of the shell and is strongly influenced by the shell composition and the physico-chemical changes in the environment. Conclusion: Diacetylene-containing microbubbles are polymerizable under influence of ionizing radiation and are a promising design concept within the development of a novel non-invasive in-vivo radiation dosimeter for external beam radiation therapy. This work was funded by the Research Foundation - Flanders (FWO)

60 APPLIED LIFE SCIENCES↗

Vaccination with Recombinant Mycobacterium tuberculosis PknD Attenuates Bacterial Dissemination to the Brain in Guinea Pigs

We have previously identified Mycobacterium tuberculosis PknD to be an important virulence factor required for the pathogenesis of central nervous system (CNS) tuberculosis (TB). Specifically, PknD mediates bacillary invasion of the blood-brain barrier, which can be neutralized by specific antisera, suggesting its potential role as a therapeutic target against TB meningitis. We utilized an aerosol challenge guinea pig model of CNS TB and compared the protective efficacy of recombinant M. tuberculosis PknD subunit protein with that of M. bovis BCG against bacillary dissemination to the brain. BCG vaccination limited the pulmonary bacillary burden after aerosol challenge with virulent M. tuberculosis in guinea pigs and also reduced bacillary dissemination to the brain (P = 0.01). PknD vaccination also offered significant protection against bacterial dissemination to the brain, which was no different from BCG (P>0.24), even though PknD vaccinated animals had almost 100-fold higher pulmonary bacterial burdens. Higher levels of PknD-specific IgG were noted in animals immunized with PknD, but not in BCG-vaccinated or control animals. Furthermore, pre-incubation of M. tuberculosis with sera from PknD-vaccinated animals, but not with sera from BCG-vaccinated or control animals, significantly reduced bacterial invasion in a human blood-brain barrier model (P<0.01). Current recommendations for administering BCG at birth are based on protection gained against severe disease, such as TB meningitis, during infancy. We demonstrate that vaccination with recombinant M. tuberculosis PknD subunit offers a novel strategy to protect against TB meningitis, which is equivalent to BCG in a guinea pig model. Moreover, since BCG lacks the PknD sensor, BCG could also be boosted to develop a more effective vaccine against TB meningitis, a devastating disease that disproportionately affects young children.

59 BASIC BIOLOGICAL SCIENCES↗

Data Processing Package for Cyclic Integrated Reversible Bending Fatigue Testing

A data processing software package has been introduced. The package was developed using MATLAB with the aid of the Curve Fitting Toolbox. The package is made up of four modules: pre-processing, data processing for static testing, data processing for monitoring, and data processing for measurements. CIRFT data are structured with multiple levels of architecture involving group, specimen, session, and scan/block. The degree of complexity of the data structure depends on whether a test is static or cyclic.The test results are presented in figures, scatter plots, and tables. For static testing, the output in tables provides bending mechanical properties and characteristic points of moment–curvature relation: flexural rigidities in linear segments of loading and unloading stages, intersection points between characteristic segments of the curve, and equivalent stress and strain quantities. For cyclic testing, the table output lists control and fatigue life and responsive/dependent quantities including moment, curvature, flexural rigidity, flexural hysteresis, rigidity phase angle, and equivalent stresses and strains. In addition, derivatives such as half-gage length and sensor spacing correction are included. The output also provides standard deviations of the reported quantities when they are applicable or available. The data processing package can serve as a fundamental characterization tool in mechanical study of materials. The package is intended primarily for data processing for the CIRFT process and can also be used in applications for which similar testing requirements exist.

36 MATERIALS SCIENCE↗