Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “learned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Multi-Agent Safe Policy Learning for Power Management of Networked Microgrids

This paper presents a supervised multi-agent safe policy learning (SMAS-PL) method for optimal power management of networked microgrids (MGs) in distribution systems. While unconstrained reinforcement learning (RL) algorithms are black-box decision models that could fail to satisfy grid operational constraints, our proposed method considers AC power flow equations and other operational limits. Accordingly, the training process employs the gradient information of operational constraints to ensure that the optimal control policy functions generate safe and feasible decisions. Furthermore, we have developed a distributed consensus-based optimization approach to train the agents’ policy functions while maintaining MGs’ privacy and data ownership boundaries. After training, the learned optimal policy functions can be safely used by the MGs to dispatch their local resources, without the need to solve a complex optimization problem from scratch. Lastly, numerical experiments have been devised to verify the performance of the proposed method.

, policy gradient↗

Deep Reinforcement Learning based Model-free On-line Dynamic Multi-Microgrid Formation to Enhance Resilience

Multi-microgrid formation (MMGF) is a promising solution for enhancing power system resilience. This paper proposes a new deep reinforcement learning (RL) based model-free on-line dynamic MMGF scheme. Additionally, the dynamic MMGF problem is formulated as a Markov decision process, and a complete deep RL framework is specially designed for the topologytransformable micro-grids. In order to reduce the large action space caused by flexible switch operations, a topology transformation method is proposed and an action-decoupling Q-value is applied. Then, a convolutional neural network (CNN) based multi-buffer double deep Q-network (CM-DDQN) is developed to further improve the learning ability of the original DQN method. The proposed deep RL method provides real-time computing to support the on-line dynamic MMGF scheme, and the scheme handles a long-term resilience enhancement problem using an adaptive on-line MMGF to defend changeable conditions. The effectiveness of the proposed method is validated using a 7-bus system and the IEEE 123-bus system. The results show strong learning ability, timely response for varying system conditions and convincing resilience enhancement.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Safe Reinforcement Learning-Based Transient Stability Control for Islanded Microgrids With Topology Reconfiguration

This paper proposes a safe reinforcement learning (RL)-based transient stability emergency control (TSEC) method for islanded microgrids. RL requires extensive interaction with the environment to learn control strategies, hence, a data-driven approach is used as a substitute for time-consuming time-domain simulation calculations. Deep sigma point processes (DSPP), which is a Gaussian process model, is utilized to predict the normal distribution of transient stability of microgrids and to construct a transient stability chance constraint. Reward-constrained policy optimization (RCPO) can simultaneously achieve objective prediction, policy learning, and constraint cost coefficient update across multiple timescales. RCPO interacts with the DSPP-based microgrid environment through a multi-process parallel manner, greatly increasing the training speed. Case studies on a real islanded microgrid demonstrate that the proposed method can efficiently and quickly obtain the optimal emergency control strategy while adhering to all hard constraints.

14 SOLAR ENERGY↗

SigTime: Learning and Visually Explaining Time Series Signatures

Understanding and distinguishing temporal patterns in time series data is essential for scientific discovery and decision-making. For example, in biomedical research, uncovering meaningful patterns in physiological signals can improve diagnosis, risk assessment, and patient outcomes. However, existing methods for time series pattern discovery face major challenges, including high computational complexity, limited interpretability, and difficulty in capturing meaningful temporal structures. Here, to address these gaps, we introduce a novel learning framework that jointly trains two Transformer models using complementary time series representations: shapelet-based representations to capture localized temporal structures and traditional feature engineering to encode statistical properties. The learned shapelets serve as interpretable signatures that differentiate time series across classification labels. Additionally, we develop a visual analytics system—SigTime—with coordinated views to facilitate exploration of time series signatures from multiple perspectives, aiding in useful insights generation. We quantitatively evaluate our learning framework on eight publicly available datasets and one proprietary clinical dataset. Additionally, we demonstrate the effectiveness of our system through two usage scenarios along with the domain experts: one involving public ECG data and the other focused on preterm labor analysis.

97 MATHEMATICS AND COMPUTING↗

MACHINE LEARNING-ENABLED PREDICTION OF TRANSIENT INJECTION MAP IN AUTOMOTIVE INJECTORS WITH UNCERTAINTY QUANTIFICATION

Accurate prediction of injection profiles is a critical aspect of linking injector operation with engine performance and emissions. However, highly resolved injector simulations can take one to two weeks of wall-clock time, which is incompatible with engine design cycles with desired turnaround times of less than a day. Hence, it is important to reduce the time-to-solution of the internal flow simulations by several orders of magnitude to make it compatible with engine simulations. This work demonstrates a data-driven approach for tackling the computational overhead of injector simulations, whereby the transient injection profiles are emulated for a side-oriented, single-hole diesel injector using a Bayesian machine-learning framework. First, an interpretable Bayesian learning strategy was employed to understand the effect of design parameters on the total void fraction field. Then, autoencoders are utilized for efficient dimensionality reduction of the flowfields. Gaussian process models are finally used to predict the spatiotemporal void fraction field at the injector exit for unknown operating conditions. The Gaussian process models produce principled uncertainty estimates associated with the emulated flowfields, which provide the engine designer with valuable information of where the data-driven predictions can be trusted in the design space. The Bayesian flowfield predictions are compared with the corresponding predictions from a deep neural network, which has been transfer-learned from static needle simulations from a previous work by the authors. The emulation framework can predict the void fraction field at the exit of the orifice within a few seconds, thus achieving a speed-up factor of up to 38 x 10(6) over the traditional simulation-based approach of generating transient injection maps.

machine learning↗

ENGINE COMBUSTION SYSTEM OPTIMIZATION USING CFD AND MACHINE LEARNING: A METHODOLOGICAL APPROACH

Gasoline compression ignition (GCI) engines are considered an attractive alternative to traditional spark-ignition and diesel engines. In this work, a Machine Learning-Grid Gradient Algorithm (ML-GGA) approach was developed to optimize the performance of internal combustion engines. Machine learning (ML) offers a pathway to transform complex physical processes that occur in a combustion engine into compact informational processes. The developed ML-GGA model was compared with a recently developed Machine learning Genetic Algorithm (ML-GA). Detailed investigations of optimization solver parameters and variables limits extension were performed in the present ML-GGA model to improve the accuracy and robustness of the optimization process. Detailed descriptions of the different procedures, optimization tools and criteria that must be followed for a successful output are provided here. The developed ML-GGA approach was used to optimize the operating conditions (case 1) and the piston bowl design (case 2) of a heavy-duty diesel engine running on a gasoline fuel with a Research Octane Number (RON) of 80. The ML-GGA approach yielded > 2% improvements in the merit function, compared to the optimum obtained from a thorough computational fluid dynamics (CFD) guided system optimization. The predictions from the ML-GGA approach were validated with engine CFD simulations. This study demonstrates the potential of ML-GGA to significantly reduce the time needed for optimization problems, without loss in accuracy compared to traditional approaches.

engine optimization↗

A planning quality evaluation tool for prostate adaptive IMRT based on machine learning

Purpose: To ensure plan quality for adaptive IMRT of the prostate, we developed a quantitative evaluation tool using a machine learning approach. This tool generates dose volume histograms (DVHs) of organs-at-risk (OARs) based on prior plans as a reference, to be compared with the adaptive plan derived from fluence map deformation. Methods: Under the same configuration using seven-field 15 MV photon beams, DVHs of OARs (bladder and rectum) were estimated based on anatomical information of the patient and a model learned from a database of high quality prior plans. In this study, the anatomical information was characterized by the organ volumes and distance-to-target histogram (DTH). The database consists of 198 high quality prostate plans and was validated with 14 cases outside the training pool. Principal component analysis (PCA) was applied to DVHs and DTHs to quantify their salient features. Then, support vector regression (SVR) was implemented to establish the correlation between the features of the DVH and the anatomical information. Results: DVH/DTH curves could be characterized sufficiently just using only two or three truncated principal components, thus, patient anatomical information was quantified with reduced numbers of variables. The evaluation of the model using the test data set demonstrated its accuracy {approx}80% in prediction and effectiveness in improving ART planning quality. Conclusions: An adaptive IMRT plan quality evaluation tool based on machine learning has been developed, which estimates OAR sparing and provides reference in evaluating ART.

60 APPLIED LIFE SCIENCES↗

Objected constrained registration and manifold learning: A new patient setup approach in image guided radiation therapy of thoracic cancer

Purpose: The management of thoracic malignancies with radiation therapy is complicated by continuous target motion. In this study, a real time motion analysis approach is proposed to improve the accuracy of patient setup. Methods: For 11 lung cancer patients a long training fluoroscopy was acquired before the first treatment, and multiple short testing fluoroscopies were acquired weekly at the pretreatment patient setup of image guided radiotherapy (IGRT). The data analysis consisted of three steps: first a 4D target motion model was constructed from 4DCT and projected to the training fluoroscopy through deformable registration. Then the manifold learning method was used to construct a 2D subspace based on the target motion (kinetic) and location (static) information in the training fluoroscopy. Thereafter the respiratory phase in the testing fluoroscopy was determined by finding its location in the subspace. Finally, the phase determined testing fluoroscopy was registered to the corresponding 4DCT to derive the pretreatment patient position adjustment for the IGRT. The method was tested on clinical image sets and numerical phantoms. Results: The registration successfully reconstructed the 4D motion model with over 98% volume similarity in 4DCT, and over 95% area similarity in the training fluoroscopy. The machine learning method derived the phase values in over 98% and 93% test images of the phantom and patient images, respectively, with less than 3% phase error. The setup approach achieved an average accumulated setup error less than 1.7 mm in the cranial-caudal direction and less than 1 mm in the transverse plane. All results were validated against the ground truth of manual delineations by an experienced radiation oncologist. The expected total time for the pretreatment setup analysis was less than 10 s. Conclusions: By combining the registration and machine learning, the proposed approach has the potential to improve the accuracy of pretreatment setup for patients with thoracic malignancy.

60 APPLIED LIFE SCIENCES↗

SU-E-T-524: Web-Based Radiation Oncology Incident Reporting and Learning System (ROIRLS)

Purpose: Describe a Web-based Radiation Oncology Incident Reporting and Learning system that has the potential to improve quality of care for radiation therapy patients. This system is an important facet of continuing effort by our community to maintain and improve safety of radiotherapy.Material and Methods: The VA National Radiation Oncology Program office has embarked on a program to electronically collect adverse events and near miss data of radiation treatment of over 25,000 veterans treated with radiotherapy annually. Software used for this program is deployed on the VAs intranet as a Website. All data entry forms (adverse event or near miss reports, work product reports) utilize standard causal, RT process step taxonomies and data dictionaries defined in AAPM and ASTRO reports on error reporting (AAPM Work Group Report on Prevention of Errors and ASTROs safety is no accident report). All reported incidents are investigated by the radiation oncology domain experts. This system encompasses the entire feedback loop of reporting an incident, analyzing it for salient details, and developing interventions to prevent it from happening again. The operational workflow is similar to that of the Aviation Safety Reporting System. This system is also synergistic with ROSIS and SAFRON. Results: The ROIRLS facilitates the collection of data that help in tracking adverse events and near misses and develop new interventions to prevent such incidents. The ROIRLS electronic infrastructure is fully integrated with each registered facility profile data thus minimizing key strokes and multiple entries by the event reporters. Conclusions: OIRLS is expected to improve the quality and safety of a broad spectrum of radiation therapy patients treated in the VA and fulfills our goal of Effecting Quality While Treating Safely The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website. The Radiation Oncology Incident Reporting and Learning System software used for this program has been developed, conceptualized and maintained by TSG Innovations Inc. and is deployed on the VA intranet as a Website.

60 APPLIED LIFE SCIENCES↗

MO-F-16A-03: AAPM Online Learning Support of New ABR MOC Requirements

In 2002 the American Board of Radiology (ABR) discontinued issuing lifetime board certification. After that time diplomates received a timelimited certificate and must participate in the Maintenance of Certification (MOC) program in order to maintain their certification. Initially certificates were issued with a 10 year expiration period and the MOC had requirements to be met over that 10 year period. The goal was to demonstrate continuous maintenance of clinical competency, however some diplomates were attempting to fulfill most or all of the requirements near the end of the 10 year period. This failed to meet the continuous aspect of the goal and so the ABR changed to a sliding 3-year window. This was done to recognize that not every year would be the same, but that diplomates should be able to maintain a reasonable average over any 3 year period.A second significant change occurred in 2013. The initial requirements included 20 selfassessment modules (SAMs) over the original 10 year term. SAMs are a special type of continuing education (CE) credit that were an addition to the 250 standard CE credits required over the 10 year period. In 2013, however, the new requirement is 75 CE credits over the previous 3 years, of which 25 must include self-assessment. Effectively this raised the self-assessment requirement from 20 in 10 years to 25 in 3 years. Previously SAMs were an interactive presentation available in limited quantities at live meetings. However, the new requirement is not for SAMs but CE-SA which includes SAMs, but also includes the online quizzes provided at the AAPM online learning center. All credits earned at the AAPM online learning center fulfill the ABR SA requirement.This talk will be an interactive demonstration of the AAPM online learning center along with a discussion of the MOC requirements.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

MO-G-BRE-06: Metrics of Success: Measuring Participation and Attitudes Related to Near-Miss Incident Learning Systems

Purpose: Interest in incident learning systems (ILS) for improving safety and quality in radiation oncology is growing, as evidenced by the upcoming release of the national ILS. However, an institution implementing such a system would benefit from quantitative metrics to evaluate performance and impact. We developed metrics to measure volume of reporting, severity of reported incidents, and changes in staff attitudes over time from implementation of our institutional ILS. Methods: We analyzed 2023 incidents from our departmental ILS from 2/2012–2/2014. Incidents were prospectively assigned a near-miss severity index (NMSI) at multidisciplinary review to evaluate the potential for error ranging from 0 to 4 (no harm to critical). Total incidents reported, unique users reporting, and average NMSI were evaluated over time. Additionally, departmental safety attitudes were assessed through a 26 point survey adapted from the AHRQ Hospital Survey on Patient Safety Culture before, 12 months, and 24 months after implementation of the incident learning system. Results: Participation in the ILS increased as demonstrated by total reports (approximately 2.12 additional reports/month) and unique users reporting (0.51 additional users reporting/month). Also, the average NMSI of reports trended lower over time, significantly decreasing after 12 months of reporting (p<0.001) but with no significant change at months 18 or 24. In survey data significant improvements were noted in many dimensions, including perceived barriers to reporting incidents such as concern of embarrassment (37% to 18%; p=0.02) as well as knowledge of what incidents to report, how to report them, and confidence that these reports were used to improve safety processes. Conclusion: Over a two-year period, our departmental ILS was used more frequently, incidents became less severe, and staff confidence in the system improved. The metrics used here may be useful for other institutions seeking to create or evaluate their own incident learning systems.

61 RADIATION PROTECTION AND DOSIMETRY↗

TU-C-12A-12: Differentiating Bone Lesions and Degenerative Joint Disease in NaF PET/CT Scans Using Machine Learning

Purpose: [F-18]NaF PET can be used to image bone metastases; however, tracer uptake in degenerative joint disease (DJD) often appears similar to metastases. This study aims to develop and compare different machine learning algorithms to automatically identify regions of [F-18]NaF scans that correspond to DJD. Methods: 10 metastatic prostate cancer patients received whole body [F-18]NaF PET/CT scans prior to treatment. Image segmentation resulted in 852 ROIs, 69 of which were identified by a nuclear medicine physician as DJD. For all ROIs, various PET and CT textural features were computed. ROIs were divided into training and testing sets used to train eight different machine learning classifiers. Classifiers were evaluated based on receiver operating characteristics area under the curve (AUC), sensitivity, specificity, and positive predictive value (PPV). We also assessed the added value of including CT features in addition to PET features for training classifiers. Results: The training set consisted of 37 DJD ROIs with 475 non-DJD ROIs, and the testing set consisted of 32 DJD ROIs with 308 non-DJD ROIs. Of all classifiers, generalized linear models (GLM), decision forests (DF), and support vector machines (SVM) had the best performance. AUCs of GLM (0.929), DF (0.921), and SVM (0.889) were significantly higher than the other models (p<0.001). GLM and DF, overall, had the best sensitivity, specificity, and PPV, and gave a significantly better performance (p<0.01) than all other models. PET/CT GLM classifiers had higher AUC than just PET or just CT. GLMs built using PET/CT information had superior or comparable sensitivities, specificities and PPVs to just PET or just CT. Conclusion: Machine learning algorithms trained with PET/CT features were able to identify some cases of DJD. GLM outperformed the other classification algorithms. Using PET and CT information together was shown to be superior to using PET or CT features alone. Research supported by the Prostate Cancer Foundation.

60 APPLIED LIFE SCIENCES↗

SU-E-E-03: Shared Space Fosters Didactic and Professional Learning Across Professions for Medical and Physics Residents

Purpose: Medical Physicists and Radiation Oncologists are two professions who should be working as a team for optimal patient care, yet lack of mutual understanding about each others respective role and work environment creates barriers To improve collaboration and learning, we designed a shared didactic and work space for physics and radiation oncology residents to maximize interaction throughout their professional training. Methods: Physician and Physics residents are required to take the same didactic classes, including journal clubs and respective seminars. The residents also share an office environment among the seven physician and two physic residents. Results: By maximizing didactic overlap and sharing office space, the two resident groups have developed a close professional relationship and supportive work environment. Several joint research projects have been initiated by the residents. Awareness of physics tasks in the clinic has led to a request by the physician residents to change physics didactics, converting the physics short course into a lab-oriented course for the medical residents which is in part taught by the physics residents. The physics seminar is given by both residency groups; increased motivation and interest in learning about physics has led to several medical resident-initiated topic selections which generated lively discussion. The physics long course has changed toward including more discussion among residents to delve deeper into topics and study beyond what passing the boards would require. A supportive work environment has developed, embedding the two physics residents into a larger residents group, allowing them to find mentor and peers more easily. Conclusion: By creating a shared work and didactic environment, physician and physics residents have improved their understanding of respective professional practice. Resident-initiated changes in didactic practice have led to improved learning and joint research. A strong social support system has developed, embedding physics residents into a larger peer group.

60 APPLIED LIFE SCIENCES↗

SU-E-J-191: Motion Prediction Using Extreme Learning Machine in Image Guided Radiotherapy

Purpose: Real-time motion tracking is a critical issue in image guided radiotherapy due to the time latency caused by image processing and system response. It is of great necessity to fast and accurately predict the future position of the respiratory motion and the tumor location. Methods: The prediction of respiratory position was done based on the positioning and tracking module in ARTS-IGRT system which was developed by FDS Team (www.fds.org.cn). An approach involving with the extreme learning machine (ELM) was adopted to predict the future respiratory position as well as the tumor’s location by training the past trajectories. For the training process, a feed-forward neural network with one single hidden layer was used for the learning. First, the number of hidden nodes was figured out for the single layered feed forward network (SLFN). Then the input weights and hidden layer biases of the SLFN were randomly assigned to calculate the hidden neuron output matrix. Finally, the predicted movement were obtained by applying the output weights and compared with the actual movement. Breathing movement acquired from the external infrared markers was used to test the prediction accuracy. And the implanted marker movement for the prostate cancer was used to test the implementation of the tumor motion prediction. Results: The accuracy of the predicted motion and the actual motion was tested. Five volunteers with different breathing patterns were tested. The average prediction time was 0.281s. And the standard deviation of prediction accuracy was 0.002 for the respiratory motion and 0.001 for the tumor motion. Conclusion: The extreme learning machine method can provide an accurate and fast prediction of the respiratory motion and the tumor location and therefore can meet the requirements of real-time tumor-tracking in image guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

SU-D-204-06: Integration of Machine Learning and Bioinformatics Methods to Analyze Genome-Wide Association Study Data for Rectal Bleeding and Erectile Dysfunction Following Radiotherapy in Prostate Cancer

Purpose: We investigated whether integration of machine learning and bioinformatics techniques on genome-wide association study (GWAS) data can improve the performance of predictive models in predicting the risk of developing radiation-induced late rectal bleeding and erectile dysfunction in prostate cancer patients. Methods: We analyzed a GWAS dataset generated from 385 prostate cancer patients treated with radiotherapy. Using genotype information from these patients, we designed a machine learning-based predictive model of late radiation-induced toxicities: rectal bleeding and erectile dysfunction. The model building process was performed using 2/3 of samples (training) and the predictive model was tested with 1/3 of samples (validation). To identify important single nucleotide polymorphisms (SNPs), we computed the SNP importance score, resulting from our random forest regression model. We performed gene ontology (GO) enrichment analysis for nearby genes of the important SNPs. Results: After univariate analysis on the training dataset, we filtered out many SNPs with p>0.001, resulting in 749 and 367 SNPs that were used in the model building process for rectal bleeding and erectile dysfunction, respectively. On the validation dataset, our random forest regression model achieved the area under the curve (AUC)=0.70 and 0.62 for rectal bleeding and erectile dysfunction, respectively. We performed GO enrichment analysis for the top 25%, 50%, 75%, and 100% SNPs out of the select SNPs in the univariate analysis. When we used the top 50% SNPs, more plausible biological processes were obtained for both toxicities. An additional test with the top 50% SNPs improved predictive power with AUC=0.71 and 0.65 for rectal bleeding and erectile dysfunction. A better performance was achieved with AUC=0.67 when age and androgen deprivation therapy were added to the model for erectile dysfunction. Conclusion: Our approach that combines machine learning and bioinformatics techniques enabled designing better models and identifying more plausible biological processes associated with the outcomes.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-09: Low-Dose CT Image Reconstruction Via Learning From Different Patient Normal-Dose Images

Purpose: To investigate a novel low-dose CT (LdCT) image reconstruction strategy for lung CT imaging in radiation therapy. Methods: The proposed approach consists of four steps: (1) use the traditional filtered back-projection (FBP) method to reconstruct the LdCT image; (2) calculate structure similarity (SSIM) index between the FBP-reconstructed LdCT image and a set of normal-dose CT (NdCT) images, and select the NdCT image with the highest SSIM as the learning source; (3) segment the NdCT source image into lung and outside tissue regions via simple thresholding, and adopt multiple linear regression to learn high-order Markov random field (MRF) pattern for each tissue region in the NdCT source image; (4) segment the FBP-reconstructed LdCT image into lung and outside regions as well, and apply the learnt MRF prior in each tissue region for statistical iterative reconstruction of the LdCT image following the penalized weighted least squares (PWLS) framework. Quantitative evaluation of the reconstructed images was based on the signal-to-noise ratio (SNR), local binary pattern (LBP) and histogram of oriented gradients (HOG) metrics. Results: It was observed that lung and outside tissue regions have different MRF patterns predicted from the NdCT. Visual inspection showed that our method obviously outperformed the traditional FBP method. Comparing with the region-smoothing PWLS method, our method has, in average, 13% increase in SNR, 15% decrease in LBP difference, and 12% decrease in HOG difference from reference standard for all regions of interest, which indicated the superior performance of the proposed method in terms of image resolution and texture preservation. Conclusion: We proposed a novel LdCT image reconstruction method by learning similar image characteristics from a set of NdCT images, and the to-be-learnt NdCT image does not need to be scans from the same subject. This approach is particularly important for enhancing image quality in radiation therapy.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-02: Lessons Learned: Clinical Trials and Operations

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗

WE-A-BRC-03: Lessons Learned: IROC Audits

Quality and safety in healthcare are inextricably linked. There are compelling data that link poor quality radiation therapy to inferior patient survival. Radiation Oncology clinical trial protocol deviations often involve incorrect target volume delineation or dosing, akin to radiotherapy incidents which also often involve partial geometric miss or improper radiation dosing. When patients with radiation protocol variations are compared to those without significant protocol variations, clinical outcome is negatively impacted. Traditionally, quality assurance in radiation oncology has been driven largely by new technological advances, and safety improvement has been driven by reactive responses to past system failures and prescriptive mandates recommended by professional organizations and promulgated by regulators. Prescriptive approaches to quality and safety alone often do not address the huge variety of process and technique used in radiation oncology. Risk-based assessments of radiotherapy processes provide a mechanism to enhance quality and safety, both for new and for established techniques. It is imperative that we explore such a paradigm shift at this time, when expectations from patients as well as providers are rising while available resources are falling. There is much we can learn from our past experiences to be applied towards the new risk-based assessments. Learning Objectives: Understand the impact of clinical and technical quality on outcomes Understand the importance of quality care in radiation oncology Learn to assess the impact of quality on clinical outcomes D. Followill, NIH Grant CA180803.

60 APPLIED LIFE SCIENCES↗