Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “fluids”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Transcapillary fluid shifts in tissues of the head and neck during and after simulated microgravity

To understand the mechanism, magnitude, and time course of facial puffiness that occurs in microgravity, seven male subjects were tilted 6 degrees head down for 8 hr, and all four Starling transcapillary pressures were directly measured before, during , and after tilt. Head-down tilt (HDT) caused facial edema and a significant elevation of microvascular pressures measured in the lower lip. Subcutaneous and intramuscular interstitial fluid pressures in the neck also increased as a result of HDT, while interstitial fluid colloid osmotic pressures remained unchanged. Plasma colloid osmotic pressures dropped significantly after 4 hr of HDT, suggesting a transition from fluid filtration to absorption in capillary beds between the heart and feet during HDT. After 4 hr of seated recovery from HDT, microvascular pressures remained significantly elevated by 5 to 8 mm Hg above baseline values despite a significant HDT diuresis and the orthostatic challenge of an upright, seated posture. During the control (baseline) period, urine output was 46.7 ml/hr; during HDT, it was 126.5 ml/hr.

Hargens, A. R.↗

Computing Properties Of Pure And Mixed Fluids

GASPLUS created as two-part code: first designed for use with pure fluids and second designed for use with mixtures of fluids and phases. Offers routines for mathematical modeling of conditions of fluids in pumps, turbines, compressors and other machines. Other routines for calculating performance of para/ortho-hydrogen reactor and heat of para/normal-hydrogen reaction as well as unique convergence routine demonstrates engineering flavor of GASPLUS. Written in FORTRAN 77.

Fowler, J. R.↗

Space Station fluid resupply

Viewgraphs on space station fluid resupply are presented. Space Station Freedom is resupplied with supercritical O2 and N2 for the ECLSS and USL on a 180 day resupply cycle. Resupply fluids are stored in the subcarriers on station between resupply cycles and transferred to the users as required. ECLSS contingency fluids (O2 and N2) are supplied and stored on station in a gaseous state. Efficiency and flexibility are major design considerations. Subcarrier approach allows multiple manifest combinations. Growth is achieved by adding modular subcarriers.

Winters, AL↗

Design review of fluid film bearing testers

The designs of three existing testers (Hybrid Bearing Tester, OTV Bearing Tester, and Long Life Bearing Tester) owned by NASA were reviewed for their capability to serve as a multi-purpose cryogenic fluid film bearing tester. The primary tester function is the validation of analytical predictions for fluid film bearing steady state and dynamic performance. Evaluation criteria were established for test bearing configurations, test fluids, instrumentation, and test objectives. Each tester was evaluated with respect to these criteria. A determination was made of design improvements which would allow the testers to meet the stated criteria. The cost and time required to make the design changes were estimated. A recommendation based on the results of this study was made to proceed with the Hybrid Bearing Tester.

Scharrer, Joseph K.↗

Some unsteady fluid forces on pump impellers

Special analyses of all the forces and moments acting on a typical centrifugal pump impeller/volute combination are presented. These exhibit shaft frequencies, blade passing frequencies, and beat frequencies associated with a whirl motion imposed on the shaft in order to measure rotordynamic forces. Among other features the unsteady thrust was found to contain a surprisingly large blade passing harmonic. While previous studies have explored the magnitudes of the steady fluid-induced radial forces and the fluid-induced rotordynamic forces for this typical centrifugal pump impeller/volute combination, this paper presents information on the steady bending moments and rotordynamic moments due to the fluid flow. These imply certain axial locations for the lines of action of the radial and rotordynamic forces. Data on the lines of action are presented and allow inferences on the sources of the forces.

Miskovish, R. S.↗

High accuracy computation of fluid-structure interaction in transonic cascades

A coupling strategy for simulating fluid-structure interaction phenomena is formulated and applied to the prediction of flutter in transonic cascades. The flow is governed by the Euler equations and discretized using a finite volume flux-splitting scheme. The structure is modeled using an isoparametric finite element formulation. The coupling strategy successfully reconciles these two formulations at the fluid-structure interface by enforcing both kinematic and kinetic boundary conditions. In particular, the conservation laws applicable to the combined fluid-structure system are preserved across the interface. Since the primary mechanism driving aeroelastic phenomena involves energy exchange occurring at the interface, this highly accurate coupling mechanism is believed to improve the predictive capability of the scheme. The coupled equations are advanced simultaneously in time using an implicit time integration method. Results obtained using the coupling method are presented for cascade geometries operating in transonic flow.

Boschitsch, Alexander↗

Invariant two-dimensional structures of vorticity field in nonviscous fluid

It is shown that a fluid flow which are invariant under translations along their vorticity field directions can be described in terms of a formally 2D system. Its nonviscous behavior of the scalar vorticity is governed by Hamiltonian dynamics, similar to the 2D line vortex case. Applying a statistical mechanical method, the equilibrium distribution of the vorticity field for such a general 2D system is shown to obey a nonlinear partial differential equation that is a generalization of the sinh-Poisson equation derived by Montgomery and Joyce (1973, 1974). Thus, if the domain containing the fluid is finite, similar negative temperature states may occur and the distribution of the vorticity intensity may become localized in space. The results are believed to have applications in studying large-scale partial and temporal properties of flows having small but nonzero viscosity. The analysis can probably be extended to other fluid systems with curved magnetic field lines.

Chen, Hudong↗

Body fluid alterations during head-down bed rest in men at moderate altitude

To determine the effects of hypoxia on fluid balance responses to simulated zero-gravity, measurements were made in six subjects before and during -5 deg continuous head-down bed rest (HDBR) over 8 d at 10,678 ft. The same subjects were studied again at this altitude without HDBR as a control (CON) using a cross-over design. During this time, they maintained normal upright day-time activities, sleeping in the horizontal position at night. Fluid balance changes during HDBR in hypoxia were more pronounced than similar measurements previously reported from HDBR studies at sea level. Plasma volume loss was slightly greater and the diuresis and natriuresis were doubled in magnitude as compared to previous studies in normoxia and sustained for 4 d during hypoxia. These changes were associated with an immediate but transient rise in plasma atrial natriuretic peptide (ANP) to day 4 of 140 percent in HDBR and 41 percent in CON (p less than 0.005), followed by a decline towards baseline. Differences were less striking between HDBR and CON for plasma antidiuretic hormone and aldosterone, which were transiently reduced by HDBR. Plasma catecholamines showed a similar pattern to ANP in both HDBR and CON, suggesting that elevated ANP and catecholamines together accounted for the enhanced fluid shifts with HDBR during hypoxia.

Loeppky, J. A.↗

Effect of the baffle on the spacecraft fluid propellant viscous stress and moment fluctuations

The dynamical behavior of fluids affected by asymmetric gravity jitter oscillations, in particular the effect of surface tension on rotating fluids in a partially filled dewar tank imposed by time-dependent directions of background gravity have been investigated. Results show that a lower frequency gravity jitter imposed on the time-dependent variations of the direction of background gravity induced a greater amplitude of oscillations and a stronger degree of asymmetry in liquid-vapor interface geometry than that caused by higher-frequency gravity jitter. As viscous force between liquid and solid interface greatly contributes to the damping effect of slosh wave excitation, a rotating dewar with installed baffle provides more areas of liquid-solid interface than a rotating dewar without baffle. Damping by baffle reduces the amplitude of slosh wave excitation, angular momentum, and fluid moment fluctuation and lowers the degree of asymmetry in the liquid-vapor distribution.

Hung, R. J.↗

Buoyancy-driven flows of a radiatively participating fluid in a vertical cylinder heated from below

The effect of radiative energy transport on the onset and evolution of natural convective flows is studied in a Rayleigh-Benard system. Steady, axisymmetric flows of a radiatively participating fluid contained in a rigid-walled, vertical cylinder which is heated on the base, cooled on top, and insulated on the side wall are calculated by using the Galerkin FEM. Bifurcation analysis techniques are used to investigate the changes in the flow structure due to internal radiation. The results of this two-parameter study - where the Rayleigh number, Ra and optical thickness, tau, are varied - apply to fluids ranging from opaque to nearly transparent with respect to IR radiation. For any nonopaque fluid, internal radiation eliminates the static state that without radiation, exists for all values of the Rayleigh number. This heat transfer mechanism also destroys a symmetry of the system that relates clockwise and counterclockwise flows. The connectivity between characteristic flow families and the range of Ra where families are stable are found to depend greatly on tau. Results demonstrate the inadequacy of characterizing the behavior of this system using simple notions of radiative transfer in optically thick or thin media; the nonlinear interaction of radiation and flow are far more complicated than these asymptotic limits would imply.

Salinger, A. G.↗

Graphical and analytical methods for the determination of a flow of a compressible fluid around an obstacle

Chaplygin introduced the hodograph method in the theory of compressible fluid flows and developed a method for constructing stream functions of such flows. This method, which has been extensively used in investigation of compressible fluid flows, is limited in certain respects. The expression for the stream function obtained in this manner can represent only certain types of flow patterns. In general, flow patterns obtained in this way cannot represent the whole flow around an obstacle, but only a part of such a flow, and therefore several expressions are needed in order to obtain the whole flow. On the other hand, in many instances it is important to have a single expression representing the whole flow. Recently Von Karman and Tsien constructed more general types of stream functions, but only by replacing the true pressure density relation by the linear pressure-specific volume relation so that their method is essential limited to flows the maximum Mach number of which is not too large. In a companion report the author derived a new formula for stream functions based on the true pressure density relation. It is not subject to the limitations of the Chaplygin method. In the present report this formula is employed to construct two-dimensional subsonic compressible fluid flows around a body similar in shape to a given symmetric obstacle. The methods described in the report are illustrated by numerical examples.

FLOW, COMPRESSIBLE-MEASUREMENT↗

On flow of electrically conducting fluids over a flat plate in the presence of a transverse magnetic field

The use of a magnetic field to control the motion of electrically conducting fluids is studied. The incompressible boundary-layer solutions are found for flow over a flat plate when the magnetic field is fixed relative to the plate or to the fluid. The equations are integrated numerically for the effect of the transverse magnetic field on the velocity and temperature profiles, and hence, the skin friction and rate of heat transfer. It is concluded that the skin friction and the heat-transfer rate are reduced when the transverse magnetic field is fixed relative to the plate and increased when fixed relative to the fluid. The total drag is increased in all of the areas.

Rossow, Vernon J↗

Evolutionary Space Station fluids management

The demand for and management issues associated with fluids usage at the evolutionary Space Station are examined. A variety of fluids such as N2, He, methane and rare gases for research and development activities as well as massive quantities of cryogenic propellants for geosynchronous orbit and planetary exploration missions will need to be accommodated at the Space Station. A data base of fluid types, quantities, and projected usage schedules suggested, and potential accommodation concepts defined. Impacts to the Space Station operational configuration and necessary 'hooks and scars' to be included in the baseline design are addressed. Also presented is an operational scenario of the delivery of a cryogenic propellant tank set to the Space Station, attachment to the Space Station, and propellant transfer to and launch of a space transfer vehicle (STV). Results indicate that the cryogenic propellant requirements of STV and lunar missions may be met by tank sets attached to the Space Station, but those of Mars missions would require off-station methods.

Stevenson, Steve↗

Characterization of fluid physics effects on cardiovascular response to microgravity (G-572)

The recognition and understanding of cardiovascular adaptation to spaceflight has experienced substantial advancement in the last several years. In-flight echocardiographic measurements of astronaut cardiac function on the Space Shuttle have documented a 15 percent reduction in both left ventricular volume index and stroke volume with a compensatory increase in heart rate to maintain cardiac output. To date, the reduced cardiac size and stroke volume have been presumed to be the consequence of the reduction in circulating fluid volume following diuresis and other physiological processes to reduce blood volume within a few days after orbital insertion. However, no specific mechanism for the reduced stroke volume has been elucidated. The following investigation proposes the use of a hydraulic model of the cardiovascular system to examine the possibility that the observed reduction in stroke volume may, in part, be related to fluid physics effects on heart function. The automated model is being prepared to fly as a GAS payload. The experimental apparatus consists of a pneumatically actuated, elliptical artificial ventricle connected to a closed-loop, hydraulic circuit with compliance and resistance elements to create physiologic pressure and flow conditions. The ventricle is instrumented with high-fidelity, acceleration-insensitive, catheter-tip pressure transducers (Millar Instruments) in the apex and base to determine the instantaneous ventricular pressures and (delta)P(sub LV) across the left ventricle (LVP(sub apex)-LVP(sub base). The ventricle is also instrumented with a flow probe and pressure transducers immediately upstream of the inflow valve and downstream of the outflow valve. The experiment will be microprocessor controlled with analog signals stored on the FM data tape recorder. By varying the circulating fluid volume, ventricular function can be determined for varying preload pressures with fixed afterload pressure. Pilot experiments on board the NASA KC-135 aircraft have demonstrated proof-of-concept and provided early support for the proposed hypothesis. A review of the pilot experiments and developmental progress on the GAS version of this experiment will be presented.

Pantalos, George M.↗

FTIR quantification of industrial hydraulic fluids in perchloroethylene

The purpose of this summer research project was to investigate whether perchloroethylene can be used as a solvent for the quantitative analysis of industrial hydraulic fluids by infrared spectroscopy employing Beer's law. Standard calibration curves using carbon-hydrogen stretching (generic) and ester absorption peaks were prepared for a series of standard dilutions at low ppm levels of concentration of seven hydraulic fluids in perchloroethylene. The absorbance spectras were recorded with 1.5-10 mm fixed and variable path length sample cells made of potassium bromide. The results indicate that using ester infrared spectral peak, it is possible to detect about 20 ppm of the hydraulic fluid in perchloroethylene.

Mehta, Narinder K.↗

Thermohydrodynamic analysis of cryogenic liquid turbulent flow fluid film bearings

A thermohydrodynamic analysis is presented and a computer code developed for prediction of the static and dynamic force response of hydrostatic journal bearings (HJB's), annular seals or damper bearing seals, and fixed arc pad bearings for cryogenic liquid applications. The study includes the most important flow characteristics found in cryogenic fluid film bearings such as flow turbulence, fluid inertia, liquid compressibility and thermal effects. The analysis and computational model devised allow the determination of the flow field in cryogenic fluid film bearings along with the dynamic force coefficients for rotor-bearing stability analysis.

Andres, Luis San↗

Weld joint concepts for on-orbit repair of Space Station Freedom fluid system tube assemblies

Because Space Station Freedom (SSF) is an independent satellite, not depending upon another spacecraft for power, attitude control, or thermal regulation, it has a variety of tubular, fluid-carrying assemblies on-board. The systems of interest in this analysis provide breathing air (oxygen and nitrogen), a working fluid (two-phase anhydrous ammonia) for thermal control, and a monopropellant (hydrazine) for station reboost. The tube assemblies run both internally and externally with respect to the habitats. They are found in up to 50 ft. continuous lengths constructed of mostly AISI 316L stainless steel tubing, but also including some Inconel 625 nickel-iron and Monel 400 nickel-copper alloy tubing. The outer diameters (OD) of the tubes range from 0.25-1.25 inches, and the wall thickness between 0.028-.095 inches. The system operational pressures range from 377 psi (for the thermal control system) to 3400 psi (for the high pressure oxygen and nitrogen supply lines in the ECLSS). SSF is designed for a fifteen to thirty year mission. It is likely that the tubular assemblies (TA's) will sustain damage or fail during this lifetime such that they require repair or replacement. The nature of the damage will be combinations of punctures, chips, scratches, and creases and may be cosmetic or actually leaking. The causes of these hypothetical problems are postulated to be: (1) faulty or fatigued fluid joints--both QD's and butt-welds; (2) micro-meteoroid impacts; (3) collison with another man-made object; and (4) over-pressure strain or burst (system origin). While the current NASA baseline may be to temporarily patch the lines by clamping metal c-sections over the defect, and then perform high pressure injection of a sealing compound, it is clear that permanent repair of the line(s) is necessary. This permanent repair could be to replace the entire TA in the segment, or perhaps the segment itself, both alternatives being extremely expensive and risky. The former would likely require extensive EVA to release TA clamps and pose great risk to other engineering subsystems, and the latter would require major de-servicing of the Station.

Jolly, Steven D.↗

Venous compliance and fluid shift measurements on Spacelab IML-1

During the first few hours of a human spaceflight mission, a headward fluid shift out of the abdomen, pelvis, and legs initiates a number of adaptive cardiovascular responses, including a loss of intravascular and extravascular fluid volume. On return to earth, these cardiovascular changes may lead to debilitating symptoms of orthostatic intolerance in an unprotected astronaut. To test the hypothesis that an inflight increase in compliance of the leg veins may contribute to this condition, measurements of lower leg fluid shift and bulk venous compliance were collected from crew members during the eight-day First International Microgravity Laboratory shuttle mission. An ultrasonic limb plethysmograph, in conjunction with two compression cuffs encircling the calf and thigh, was used to determine bulk compliance of the underlying veins over a range of negative and positive transmural pressures. The data from inflight experiment sessions were compared to preflight and postflight sessions. The preliminary results indicate that the volume of the lower leg decreased by over 10 percent by the sixth day of flight, but there was no apparent change in venous compliance.

Leiski, D.↗