Turbulent transport models for scramjet flowfields

Turbulence modeling approaches were examined from the standpoint of their capability to predict the complex flowfield features observed in scramjet combustions. Thus, for example, the accuracy of each turbulence model, with respect to the prediction of recirculating flows, was examined. It was observed that for large diameter ratio axisymmetric sudden expansion flows, a choice of turbulence model was not critical because of the domination of their flowfields by pressure forces. For low diameter ratio axisymmetric sudden expansions and planar backward-facing steps flows, where turbulent shear stresses are of greater significance, the algebraic Reynolds stress approach, modified to increase its sensitivity to streamline curvature, was found to provide the best results. Results of the study also showed that strongly swirling flows provide a stringent test of turbulence model assumptions. Thus, although flows with very high swirl are not of great practical interest, they are useful for turbulence model development. Finally, it was also noted that numerical flowfields solution techniques have a strong interrelation with turbulence models, particularly with the turbulent transport models which involve source-dominated transport equations.

Sindir, M. M.↗

Application of a new K-tau model to near wall turbulent flows

A recently developed K-tau model for near wall turbulent flows is applied to a variety of test cases. The turbulent flows considered include the incompressible flat plate boundary layer with adverse pressure gradients, incompressible flow past a backward facing step, and the supersonic flat plate boundary layer at zero pressure gradient. Calculations are performed for this two-equation model using an anisotropic as well as isotropic eddy-viscosity. The model predictions are shown to compare quite favorably with experimental data.

Abid, R.↗

Present status of the MIT/NASA Langley 6-inch MSBS

The latest improvements are described which were made to the MIT/NASA Langley 6 Inch Magnetic Suspension and Balance System and its operational capabilities. Since its relocation from MIT in 1984, the system has suffered from reliability problems with original equipment. System performance is ultimately limited by noise and antiquated power supplies. Although a limited amount of funding and man hours has been expended, some significant improvements were made to the system. The design and implementation of a new electro-magnetic position sensor has significantly reduced system noise and drift. The system was shown fully operational for the first time since its arrival at NASA Langley. An ogive cylinder test model was suspended while running the wind tunnel at its maximum of approx. Mach 0.5. Other aerodynamic models were suspended with wind on. Also, the simulation of low speed cavity store separation using an ogive cylinder test model is described. Methods used for flow visualization for this test are also discussed. The system is ideally suited for this type of low speed testing.

Schott, Timothy↗

Intermittent-flow coefficients of a poppet valve

Flow coefficients were determined for the inlet valve of a modern air-cooled cylinder during operation of the valve. The cylinder head with valves was mounted on a large tank that could be evacuated. Operating the valve with a rotating cam allowed air to flow through the valve into the evacuated tank. The change of pressure in the tank was a measure of the amount of air flowing though the valve in a given number of cycles. The flow coefficients were determined from the pressure across the valve, the quantity of air flowing, and the valve-lift curve. Coefficients were measured with lifts of 0.1 to 0.6 inch and speeds of 130 to 1,200 r.p.m. The results obtained with intermittent flow were compared with the results of tests made with steady flow through this cylinder head. This comparison indicated that steady-flow coefficients can be used for intermittent flow.

Waldron, C D↗

Flow-visualization study of the X-29A aircraft at high angles of attack using a 1/48-scale model

A water-tunnel study on a 1/48-scale model of the X-29A aircraft was performed at the NASA Dryden Flow Visualization Facility. The water-tunnel test enhanced the results of the X-29A flight tests by providing flow-visualization data for comparison and insights into the aerodynamic characteristics of the aircraft. The model was placed in the water tunnel at angles of attack of 20 to 55 deg. and with angles of sideslip from 0 to 5 deg. In general, flow-visualization techniques provided useful information on vortex formation, separation, and breakdown and their role in yaw asymmetries and tail buffeting. Asymmetric forebody vortices were observed at angles of attack greater than 30 deg. with 0 deg. sideslip and greater than 20 deg. with 5 deg. sideslip. While the asymmetric flows observed in the water tunnel did not agree fully with the flight data, they did show some of the same trends. In addition, the flow visualization indicated that the interaction of forebody vortices and the wing wake at angles of attack between 20 and 35 deg. may cause vertical-tail buffeting observed in flight.

Cotton, Stacey J.↗

Development of the Packed Bed Reactor ISS Flight Experiment

Packed bed reactors are compact, require minimum power and maintenance to operate, and are highly reliable. These features make this technology a leading candidate as a potential unit operation in support of long duration human space exploration. On earth, this type of reactor accounts for approximately 80% of all the reactors used in the chemical process industry today. Development of this technology for space exploration is truly crosscutting with many other potential applications (e.g., in-situ chemical processing of planetary materials and transport of nutrients through soil). NASA is developing an ISS experiment to address this technology with particular focus on water reclamation and air revitalization. Earlier research and development efforts funded by NASA have resulted in two hydrodynamic models which require validation with appropriate instrumentation in an extended microgravity environment. The first model developed by Motil et al., (2003) is based on a modified Ergun equation. This model was demonstrated at moderate gas and liquid flow rates, but extension to the lower flow rates expected in many advanced life support systems must be validated. The other model, developed by Guo et al., (2004) is based on Darcy s (1856) law for two-phase flow. This model has been validated for a narrow range of flow parameters indirectly (without full instrumentation) and included test points where the flow was not fully developed. The flight experiment presented will be designed with removable test sections to test the hydrodynamic models. The experiment will provide flexibility to test additional beds with different types of packing in the future. One initial test bed is based on the VRA (Volatile Removal Assembly), a packed bed reactor currently on ISS whose behavior in micro-gravity is not fully understood. Improving the performance of this system through an accurate model will increase our ability to purify water in the space environment.

Patton, Martin O.↗

Flow field design for zero-gap microbial electrolysis cells using synthetic and real wastewater

Increasing performance in microbial electrolysis cells (MECs) requires the development of optimized reactor configurations with minimal internal resistance and capable to operate with real wastewater. Here, the impact of two different flow fields (serpentine and circular) was examined in zero-gap MECs with synthetic and real wastewaters. The serpentine flow field enabled a uniform distribution of the electrolyte in the anode chamber, resulting in larger current densities at lower flow rates compared to the circular flow field. Electrochemical tests using synthetic media with high buffer capacity revealed more stable and higher performance with the serpentine flow field compared to the circular flow path, producing larger current density (23.7 ± 0.8 A/m 2 vs 21.9 ± 5.6 A/m 2 ), hydrogen production rate (75.8 ± 4.1 L/L-d vs 54.3 ± 2.4 L/L-d), cathodic coulombic efficiency (>91 % vs >50 %), and an overall lower internal resistance (12.5 ± 0.5 mΩm 2 vs 14.8 ± 3.7 mΩm 2 ). Continuous operation for over 30 days with real wastewater indicated higher tolerance of the MECs with serpentine flow field toward media with large concentration of suspended solids, producing a current density of 5.4 ± 1.1 A/m 2 and a hydrogen production rate of 22.2 ± 6.2 L/L-d. Furthermore, the results presented here underscore the importance of reactor design and architecture in optimizing MEC performance for hydrogen production from liquid wastes.

flow path↗

Attrition of hematite particles for chemical looping combustion in a conical jet cup

The attrition of hematite particles for use in the chemical looping combustion process was investigated using a cold flow jet cup test. Jet cup attrition experiments are commonly used for bulk attrition testing of fluidized bed catalyst. The results indicate that the particle attrition in the jet cup cold flow experiments arises from surface abrasion due to particle-particle and particle-wall interactions. Experiments indicate that the measured cumulative mass loss increases with attrition time. However, the attrition rate decreases sharply at the early stage of attrition, and gradually, the rate decline slows and approaches a constant value with increasing attrition time. Furthermore, the influence of inlet gas velocity and solid inventory is discussed. As inlet gas velocities increase, the measured cumulative mass loss also increases. However, as the solid inventory increases, the cumulative mass loss decreases. The results also show that the jet cup experiments quantitatively compare with low magnitude tangential forces which is an indication of attrition through abrasion as the primary mechanism. It is determined through particle size distributions before and after which show a small shift of the main peaks with no peak broadening while producing a small number of fines. By using the mass of abraded fines and the widely-used Archard model for abrasive attrition, the specific wear rate coefficient can be predicted as a function of time. The wear coefficient calculation further identifies that the abrasion mechanism as the primary mechanism of attrition.

42 ENGINEERING↗

An oxidation and erosion test facility for cooled panels

The Panel Oxidation and Erosion Testbed (POET) facility under construction at GASL to provide the required test environment is described. The POET facility comprises three major element including a vitiated air heater, a supersonic nozzle, and a test section. A hydrogen-fueld vitiated air heater will provide the oxidizing and erosive environment. The flow through the test section characterized by low supersonic speed and Mach number of 1.4 will maximize the local heat transfer rate and the local surface shear stress.

Swartwout, W. H.↗

Problems Encountered During the Recertification of the GLORY Solar Array Dual Axis Gimbal Drive Actuators

The Glory observatory is the current incarnation of the Vegetation Canopy Lidar (VCL) mission spacecraft bus. The VCL spacecraft bus, having been cancelled for programmatic reasons in 2000, was nearly integrated when it was put into storage for possible future use. The Glory mission was a suitable candidate for using this spacecraft and in 2006 an effort to recertify the two axis solar array gimbal drive after its extended storage was begun. What was expected to be a simple performance validation of the two dual axis gimbal stepper motors became a serious test, diagnosis and repair task once questions arose on the flight worthiness of the hardware. A significant test program logic flow was developed which identified decisions that could be made based on the results of individual recertification tests. Without disassembling the bi-axial gimbals, beginning with stepper motor threshold voltage measurements and relating these to powered drive torque measurements, both performed at the spacecraft integrator s facility, a confusing picture of the health of the actuators came to light. Tests at the gimbal assembly level and tests of the disassembled actuators were performed by the manufacturer to validate our results and torque discrepancies were noted. Further disassembly to the component level of the actuator revealed the source of the torque loss.

Saltzman, Marc↗

Testing of an Ammonia EVA Vent Tool for the International Space Station

When components of the International Space Station ammonia External Active Thermal Control System are replaced on-orbit, they must be vented immediately after removal from the system. Venting ensures that the component is not hard packed with liquid and thus does not pose a hazard. An extravehicular activity (EVA) vent tool has been developed to perform this function. However, there were concerns that the tool could whip, posing a hazard to the EVA astronaut, or would freeze. The ammonia vent tool was recently tested in a thermal/vacuum chamber to demonstrate that it would operate safely and would not freeze during venting. During the test, ammonia mimicking the venting conditions for six different heat exchanger initial conditions was passed through representative test articles. In the present work, the model that was used to develop the ammonia state and flow for the test points is discussed and the test setup and operation is described. The qualitative whipping and freezing results of the test are discussed and vent plume pressure measurements are described and interpreted.

Ungar, Eugene K.↗

Testing of a controller for a hybrid capillary pumped loop thermal control system

A controller for a series hybrid capillary pumped loop (CPL) system that requires no moving parts does not resrict fluid flow has been tested and has demonstrated improved performance characteristics over a plain CPL system and simple hybrid CPL systems. These include heat load sharing, phase separation, self-regulated flow control and distribution, all independent of most system pressure drop. In addition, the controlled system demonstrated a greater heat transport capability than the simple CPL system but without the large fluid inventory requirement of the hybrid systems. A description of the testing is presented along with data that show the advantages of the system.

Schweickart, Russell↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Waste Treatment Plant laboratory (LAB) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing, determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rates along with the average and maximum qualified stack flow rates for each of the LAB facility stacks. For each stack, the operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAB facility. Flow angle results were primarily less than 10°, except for the LB-C2 Fan A results, which were an average of 13.7°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition averaged between 1.5 and 4.1% COV, which were all within the range of the target percent coefficient of variation values from the scale model tests. Based on these stack verification test results, the three LAB filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan as well as dual-fan operations for LB-C2, each of the dual-fan operating conditions for LB-S1, and each single-fan operating condition for LB-S2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Deployable Aeroshell Flexible Thermal Protection System Testing

Deployable aeroshells offer the promise of achieving larger aeroshell surface areas for entry vehicles than otherwise attainable without deployment. With the larger surface area comes the ability to decelerate high-mass entry vehicles at relatively low ballistic coefficients. However, for an aeroshell to perform even at the low ballistic coefficients attainable with deployable aeroshells, a flexible thermal protection system (TPS) is required that is capable of surviving reasonably high heat flux and durable enough to survive the rigors of construction handling, high density packing, deployment, aerodynamic loading and aerothermal heating. The Program for the Advancement of Inflatable Decelerators for Atmospheric Entry (PAIDAE) is tasked with developing the technologies required to increase the technology readiness level (TRL) of inflatable deployable aeroshells, and one of several of the technologies PAIDAE is developing for use on inflatable aeroshells is flexible TPS. Several flexible TPS layups were designed, based on commercially available materials, and tested in NASA Langley Research Center's 8 Foot High Temperature Tunnel (8ft HTT). The TPS layups were designed for, and tested at three different conditions that are representative of conditions seen in entry simulation analyses of inflatable aeroshell concepts. Two conditions were produced in a single run with a sting-mounted dual wedge test fixture. The dual wedge test fixture had one row of sample mounting locations (forward) at about half the running length of the top surface of the wedge. At about two thirds of the running length of the wedge, a second test surface drafted up at five degrees relative to the first test surface established the remaining running length of the wedge test fixture. A second row of sample mounting locations (aft) was positioned in the middle of the running length of the second test surface. Once the desired flow conditions were established in the test section the dual wedge test fixture, oriented at 5 degrees angle of attack down, was injected into the flow. In this configuration the aft sample mounting location was subjected to roughly twice the heat flux and surface pressure of the forward mounting location. The tunnel was run at two different conditions for the test series: 1) 'Low Pressure', and 2) 'High Pressure'. At 'Low Pressure' conditions the TPS layups were tested at 6W/cm2 and 11W/cm2 while at 'High Pressure' conditions the TPS layups were tested at 11W/cm2 and 20W/cm2. This paper details the test configuration of the TPS samples in the 8Ft HTT, the sample holder assembly, TPS sample layup construction, sample instrumentation, results from this testing, as well as lessons learned.

Hughes, Stephen J.↗

Launch vehicle test and checkout plan. - Volume 2: Saturn 1B launch vehicle Skylab R (rescue) and AS-208 flow plan and listings

The launch operations test and checkout plan is a planning document that establishes all launch site checkout activity, including the individual tests and sequence of testing required to fulfill the development center and KSC test and checkout requirements. This volume contains the launch vehicle test and checkout plan encompassing S-1B, S-4B, IU stage, and ground support equipment tests. The plan is based upon AS-208 flow utilizing a manned spacecraft, LUT 1, and launch pad 39B facilities.

Source record↗

Direct measurements of irradiation-induced creep in micropillars of amorphous Cu{sub 56}Ti{sub 38}Ag{sub 6}, Zr{sub 52}Ni{sub 48}, Si, and SiO{sub 2}

We report in situ measurements of irradiation-induced creep on amorphous (a-) Cu{sub 56}Ti{sub 38}Ag{sub 6}, Zr{sub 52}Ni{sub 48}, Si, and SiO{sub 2}. Micropillars 1 μm in diameter and 2 μm in height were irradiated with ∼2 MeV heavy ions during uniaxial compression at room temperature. The creep measurements were performed using a custom mechanical testing apparatus utilizing a nanopositioner, a silicon beam transducer, and an interferometric laser displacement sensor. We observed Newtonian flow in all tested materials. For a-Cu{sub 56}Ti{sub 38}Ag{sub 6}, a-Zr{sub 52}Ni{sub 48}, a-Si, and Kr{sup +} irradiated a-SiO{sub 2} irradiation-induced fluidities were found to be nearly the same, ≈3 GPa{sup −1} dpa{sup −1}, whereas for Ne{sup +} irradiated a-SiO{sub 2} the fluidity was much higher, 83 GPa{sup −1} dpa{sup −1}. A fluidity of 3 GPa{sup −1} dpa{sup −1} can be explained by point-defect mediated plastic flow induced by nuclear collisions. The fluidity of a-SiO{sub 2} can also be explained by this model when nuclear stopping dominates the energy loss, but when the electronic stopping exceeds 1 keV/nm, stress relaxation in thermal spikes also contributes to the fluidity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of swirling flow on augmentor performance

A test program was conducted with an augmentor which employed swirling flow as a means of promoting rapid flame propagation. The program evaluated the effect of augmentor length, swirl intensity, fuel zoning and Mach number on augmentor performance. Combustion efficiencies near 100% were demonstrated over most of the operating range which extended from an equivalence ratio of 0.2 to over 1.0. The tests were conducted at an inlet temperature of 649 C (1200 F) and at a pressure of 2 atmospheres. The augmentor total pressure losses were typical of current state of the art augmentors.

Clements, T. R.↗

Method for Measuring Thermal Conductivity of Small Samples Having Very Low Thermal Conductivity

This paper describes the development of a hot plate method capable of using air as a standard reference material for the steady-state measurement of the thermal conductivity of very small test samples having thermal conductivity on the order of air. As with other approaches, care is taken to ensure that the heat flow through the test sample is essentially one-dimensional. However, unlike other approaches, no attempt is made to use heated guards to block the flow of heat from the hot plate to the surroundings. It is argued that since large correction factors must be applied to account for guard imperfections when sample dimensions are small, it may be preferable to simply measure and correct for the heat that flows from the heater disc to directions other than into the sample. Experimental measurements taken in a prototype apparatus, combined with extensive computational modeling of the heat transfer in the apparatus, show that sufficiently accurate measurements can be obtained to allow determination of the thermal conductivity of low thermal conductivity materials. Suggestions are made for further improvements in the method based on results from regression analyses of the generated data.

Miller, Robert A.↗