Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distribution system monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

(Paper) TRIPWIRE: Multi-modal Distributed Sensing For Repository Verification

Underground geological repositories for storing used nuclear fuel are being planned and developed around the world. Research is being performed to understand technical aspects of sealing entombed materials and underground repositories to ensure the radiological and nuclear materials remain contained. To support safeguards verification for these facilities research at Idaho National Laboratory (INL) is underway to develop and demonstrate a multi-modal sensor system, TRIPWIRE, for containment verification in inaccessible radiological and nuclear waste repositories. The TRIPWIRE system will continuously monitor ionizing radiation and electromagnetic fields in the vicinity of emplaced nuclear materials buried in a repository, reporting on disturbances with a real-time alarm control station. The system will use long-length scintillating fiber bundles (SFBs) to perform area radiation monitoring; these will be coupled to kilometer-scale multimodal optical communication fibers – all light sensors and electronic components used with this system will be located above ground. Electromagnetic fields, and changes in local dielectric conditions caused by intrusion and soil movement, will be monitored using commercial grade, ported "leaky" coaxial cables (PCCs), with control electronics also located above ground. Tamper-indicating self-diagnostic assessments will be done using optical and electronic time domain reflectometry in the SFBs and PCCs, respectively. The result will be a long, kilometer-scale multi-modal SFB-PCC system. Simulation and modeling are being used to inform the work and a demonstration of the system's utility is planned at a nuclear storage facility in the future.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Development and Testing of a Friction-Based Post-Installable Fiber-Optic Monitoring System for Subsea Applications

This paper presents the design and development of a friction-based coupling device for a fiber-optic monitoring system capable of measuring pressure, strain, and temperature that can be deployed on existing subsea structures. A summary is provided of the design concept, prototype development, prototype performance testing, and subsequent design refinements of the device. The results of laboratory testing of the first prototype performed at the National Aeronautics and Space Administration (NASA) Johnson Space Center (JSC) are also included. Limitations of the initial concept were identified during testing and future design improvements were proposed and later implemented. These new features enhance the coupling of the sensor device and improve the monitoring system measurement capabilities. A major challenge of a post-installed instrumentation monitoring system is to ensure adequate coupling between the instruments and the structure of interest for reliable measurements. Friction-based devices have the potential to overcome coupling limitations caused by marine growth and soil contamination on flowlines, risers, and other subsea structures. The work described in this paper investigates the design and test of a friction-based coupling device (herein referred to as a friction clamp) which is suitable for pipelines and structures that are suspended in the water column as well as for those that are resting on the seabed. The monitoring elements consist of fiberoptic sensors that are bonded to a stainless steel clamshell assembly with a high-friction surface coating. The friction clamp incorporates a single hinge design to facilitate installation of the clamp and dual rows of opposing fasteners to distribute the clamping force along the structure. The friction clamp can be modified to be installed by commercial divers in shallow depths or by remotely operated vehicles in deep-water applications. NASA-JSC was involved in the selection and testing of the friction coating, and in the design and testing of the prototype clamp device. Four-inch diameter and eight-inch diameter sub-scale friction clamp prototypes were built and tested to evaluate the strain measuring capabilities of the design under different loading scenarios. The testing revealed some limitations of the initial design concept, and subsequent refinements were explored to improve the measurement performance of the system. This study was part of a collaboration between NASA-JSC and Astro Technology Inc. within a study called Clear Gulf. The primary objective of the Clear Gulf study is to develop advanced instrumentation technologies that will improve operational safety and reduce the risk of hydrocarbon spillage. NASA provided unique insights, expansive test facilities, and technical expertise to advance technologies that will benefit the environment, the public, and commercial industries.

Bentley, Nicole L.↗

MO-AB-BRA-03: Calorimetry-Based Absorbed Dose to Water Measurements Using Interferometry

Purpose: Interferometry-based calorimetry is a novel technique to measure radiation-induced temperature changes allowing the measurement of absorbed dose to water (ADW). There are no mechanical components in the field. This technique also has the possibility of obtaining 2D dose distributions. The goal of this investigation is to calorimetrically-measure doses between 2.5 and 5 Gy over a single projection in a photon beam using interferometry and compare the results with doses calculated using the TG-51 linac calibration. Methods: ADW was determined by measuring radiation-induced phase shifts (PSs) of light passing through water irradiated with a 6 MV photon beam. A 9×9×9 cm{sup 3} glass phantom filled with water and placed in an arm of a Michelson interferometer was irradiated with 300, 400, 500 and 600 monitor units. The whole system was thermally insulated to achieve sufficient passive temperature control. The depth of measurement was 4.5 cm with a field size of 7×7 cm{sup 2}. The intensity of the fringe pattern was monitored with a photodiode and used to calculate the time-dependent PS curve. Data was acquired 60 s before and after the irradiation. The radiation-induced PS was calculated by taking the difference in the pre- and post-irradiation drifts extrapolated to the midpoint of the irradiation. Results were compared to computed doses. Results: Average comparison of calculated ADW values with interferometry-measured values showed an agreement to within 9.5%. k=1 uncertainties were 4.3% for calculations and 14.7% for measurements. The dominant source of uncertainty for the measurements was a temperature drift of about 30 µK/s caused by heat conduction from the interferometer’s surroundings. Conclusion: This work presented the first absolute ADW measurements using interferometry in the dose range of linac-based radiotherapy. Future work to improve measurements’ reproducibility includes the implementation of active thermal control techniques.

60 APPLIED LIFE SCIENCES↗

Chapter 10 - Remote Sensing Measurements of Aerosol Properties

Satellite instruments have proven especially capable at monitoring the quantity of airborne particles in columns of atmosphere, globally. This chapter describes the principles of satellite measurements and retrieval algorithms, and surveys current instruments and their capabilities. We outline the issues associated with retrieval algorithms, such as surface characterization and aerosol proximity to clouds, and the challenges with interpretation of the results. The relationship between measured aerosol properties and climate-relevant aerosol properties simulated in models is outlined, as well as how measurements are used to evaluate models. Most space-based aerosol instruments are passive sensors that measure reflected sunlight at multiple wavelengths, some at multiple viewing angles. A few are active sensors that send out their own laser light and measure the returned signal. Except when clouds are present, the excess amount of light scattered back to space, beyond that expected from the surface and atmospheric gas, is attributed to aerosol. Satellite measurements are used in many ways in aerosol research. They often provide the only method for monitoring hazardous phenomena such as major wildfire and volcanic eruption plumes, especially in remote areas. Stable, long-term, near-global-scale satellite data records make it possible to identify regional and global aerosol trends. Aerosol radiative effects on climate can be quantified on a near-global scale and used to estimate the strength of aerosol–radiation and aerosol–cloud interactions as well as to evaluate climate model simulations of these interactions. Aerosol-type mapping from satellite imagery is helpful for source attribution, model validation, and to constrain particle light-absorption properties that are essential for radiative forcing calculations. The range of aerosol properties retrieved from satellite observations has grown considerably since the first global estimates of aerosol optical depth (τ a) over ocean were made in the late 1970s. Methods for retrieving particle size and light-absorption properties were explored in the 1990s using multispectral, multi-angle observations, and polarization in visible and near-infrared wavelengths. Sensitivity to particle light absorption, primarily from black or brown carbon content, improved with the inclusion of UV channels, and sensitivity to very thin aerosol layers in the upper troposphere and lower stratosphere was advanced with the use of limb-sounding instruments and active sensors. There are limitations to every measurement technique, including satellite aerosol remote sensing. For wide-swath, passive instruments, aerosol retrievals near clouds can present substantial challenges as far as 15 km away due to cloud-scattered light contaminating the signal. In nearly all cases, retrievals over bright snow and ice surfaces are precluded because surface reflectance uncertainties can overwhelm the aerosol signal. Similarly, meteorological cloud is identified and masked out where possible. Data from passive sensors also lack vertical resolution except those that view toward the limb or where multi-angle imagery is acquired over plumes from wildfires, erupting volcanoes, and wind-blown dust. Yet, passive sensors provide vastly more coverage than the active instruments that mitigate these issues. Particle microphysical information is qualitative from all remote sensing techniques, relying on proxies to infer particle composition, hygroscopicity, and the amount of light-absorbing material. Further, particles smaller than about 200 nm diameter cannot be distinguished from atmospheric gas molecules with remote sensing, which hinders studies of cloud condensation nuclei and their effects on clouds. Most satellite instruments dedicated to aerosol observations are in low-Earth, near-polar, sun-synchronous orbits, which means they cross the equator at the same local time each day. Most are set on cycles that repeat approximately every 16 days, which makes it difficult to monitor aerosol evolution locally. Geostationary satellites make it possible to observe changes occurring from minutes to hours over regions up to 8000 km in size, but lack coverage of high latitudes, and often provide more limited constraints on aerosol properties. Ground-truth data are vital for satellite aerosol-retrieval validation. The AErosol RObotic NETwork (AERONET) of sun photometers was created in 1993 and has become an established global network of over 350 instruments for validating satellite measurements. The network, as well as global networks of ground-based lidars, solar flux radiometers and other sun photometers, are widely used for evaluating global satellite retrievals and model simulations. NASA's Earth Observing System (EOS) program beginning in 1999 led to improvements in reliability, spatial resolution, and spectral resolution (and hence, to improved particle size discrimination and light absorption properties). Satellite payloads include advanced broad-swath and multi-angle imagers, along with the first space-based active sensor focused largely on long-term aerosol monitoring. Since about 2002, Europe's SENTINEL and operational meteorological satellite fleets are also providing sustained aerosol observations, with planned continuation until at least 2030. Satellite remote sensing instruments offer valuable data for evaluating aerosol representations in global climate models. They have been used to assess aerosol optical and physical properties, trends and distributions, and are applied increasingly as direct model constraints in data assimilation to create global aerosol reanalysis products. Aerosol optical depth is the most common quantity adopted for routine model evaluation, including multiwavelength data to loosely constrain particle-size distributions. These evaluations of multiple models have revealed general biases in their regional aerosol amounts and seasonal patterns of transport and removal. Although satellite measurements have near-global coverage, substantial errors can be introduced into the model observation comparison unless attention is paid to spatial and temporal collocation, cloud screening, subgrid-scale variability, and measurement uncertainties that vary with retrieval conditions.

aerosol properties↗

FREQUENCY OF SOLAR-LIKE SYSTEMS AND OF ICE AND GAS GIANTS BEYOND THE SNOW LINE FROM HIGH-MAGNIFICATION MICROLENSING EVENTS IN 2005-2008

We present the first measurement of the planet frequency beyond the 'snow line', for the planet-to-star mass-ratio interval -4.5 < log q < -2, corresponding to the range of ice giants to gas giants. We find (d{sup 2}N{sub pl})/(d log q d log s) = (0.36{+-}0.15) dex{sup -2} at the mean mass ratio q = 5 x 10{sup -4} with no discernible deviation from a flat (Oepik's law) distribution in log-projected separation s. The determination is based on a sample of six planets detected from intensive follow-up observations of high-magnification (A>200) microlensing events during 2005-2008. The sampled host stars have a typical mass M{sub host} {approx} 0.5 M {sub sun}, and detection is sensitive to planets over a range of planet-star-projected separations (s {sup -1}{sub max} R {sub E}, s{sub max} R {sub E}), where R {sub E} {approx} 3.5 AU(M{sub host}/M{sub sun}){sup 1/2} is the Einstein radius and s {sub max} {approx} (q/10{sup -4.3}){sup 1/3}. This corresponds to deprojected separations roughly three times the 'snow line'. We show that the observations of these events have the properties of a 'controlled experiment', which is what permits measurement of absolute planet frequency. High-magnification events are rare, but the survey-plus-follow-up high-magnification channel is very efficient: half of all high-mag events were successfully monitored and half of these yielded planet detections. The extremely high sensitivity of high-mag events leads to a policy of monitoring them as intensively as possible, independent of whether they show evidence of planets. This is what allows us to construct an unbiased sample. The planet frequency derived from microlensing is a factor 8 larger than the one derived from Doppler studies at factor {approx}25 smaller star-planet separations (i.e., periods 2-2000 days). However, this difference is basically consistent with the gradient derived from Doppler studies (when extrapolated well beyond the separations from which it is measured). This suggests a universal separation distribution across 2 dex in planet-star separation, 2 dex in mass ratio, and 0.3 dex in host mass. Finally, if all planetary systems were 'analogs' of the solar system, our sample would have yielded 18.2 planets (11.4 'Jupiters', 6.4 'Saturns', 0.3 'Uranuses', 0.2 'Neptunes') including 6.1 systems with two or more planet detections. This compares to six planets including one two-planet system in the actual sample, implying a first estimate of 1/6 for the frequency of solar-like systems.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated Liquid Microjunction Surface Sampling-HPLC-MS/MS Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections

A fully automated liquid extraction-based surface sampling system utilizing a commercially available autosampler coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) detection is reported. Discrete spots selected for droplet-based sampling and automated sample queue generation for both the autosampler and MS were enabled by using in-house developed software. In addition, co-registration of spatially resolved sampling position and HPLC-MS information to generate heatmaps of compounds monitored for subsequent data analysis was also available in the software. The system was evaluated with whole-body thin tissue sections from propranolol dosed rat. The hands-free operation of the system was demonstrated by creating heatmaps of the parent drug and its hydroxypropranolol glucuronide metabolites with 1 mm resolution in the areas of interest. The sample throughput was approximately 5 min/sample defined by the time needed for chromatographic separation. The spatial distributions of both the drug and its metabolites were consistent with previous studies employing other liquid extraction-based surface sampling methodologies.

drug metabolism↗

Mechanics of failure of composite materials

Composite materials are both inhomogeneous and anisotropic. Both of these characteristics affect the internal stress distributions since inhomogeneity involves variations in both strength and stiffness. The fracture mechanics of nonuniform materials are considered, taking into account the effect of nonuniformity on stress distributions near the crack tip, predicted yield zones in nonuniform and uniform materials, and the fracture of a center-notched unidirectional specimen. The mechanics of failure of laminated materials is discussed. It is found that the development of damage in a laminate with increasing load and, possibly, increasing numbers of cycles of loading is peculiar to the laminate in question, i.e., the material system, the stacking sequence, and the geometry. Approaches for monitoring damage development are also described.

Reifsnider, K. L.↗

Aerodynamic investigation by infrared imaging

Infrared imaging systems can be used to measure temperatures of actively heated bodies immersed in an airstream. This monitoring of the convective heat transfer process, provides also information about the interaction between the body and the flow. The concept appeals to Nusselt/Reynolds numbers relations in order to produce data of interest from surface temperatures. Two test cases are presented and reference is made to analytical results: the mapping of a laminar jet and the temperature distribution along a constant power heated flat plate in laminar boundary layer regime. Although this research is currently focused on low speed aerodynamics, the extension to high speed aerodynamics, where the body undergoes frictional heating is of interest in this context, too.

Roberts, A. Sidney, Jr.↗

Fiber-Optic Distribution Of Pulsed Power To Multiple Sensors

Optoelectronic systems designed according to time-sharing scheme distribute optical power to multiple integrated-circuit-based sensors in fiber-optic networks. Networks combine flexibility of electronic sensing circuits with advantage of electrical isolation afforded by use of optical fibers instead of electrical conductors to transmit both signals and power. Fiber optics resist corrosion and immune to electromagnetic interference. Sensor networks of this type useful in variety of applications; for example, in monitoring strains in aircraft, buildings, and bridges, and in monitoring and controlling shapes of flexible structures.

Kirkham, Harold↗

DATA RECOVERY EFFORTS AT IDAHO NATIONAL LABORATORY, OAK RIDGE NATIONAL LABORATORY, AND SAVANNAH RIVER NATIONAL LABORATORY

Abstract was already submitted. Could not find the previous number. Would be fine with attaching/update of old number. Abstract Below: Modern nuclear facilities will have significant process monitoring capability for their operators. These systems will also be used for domestic safeguards applications, which has led to research over new diversion-detection algorithms. Curiously missing from these efforts are verification and validation data sets. A tri-laboratory project to locate the existing data sets and recover their data has yielded three major potential sources of data. The first is recovery of the process monitoring data of the Idaho Chemical Processing Plant, which now has a distributable package for algorithm developers. The second data set is extensive sampling and process data from Savannah River National Laboratory’s F- and H-canyon sites. Finally, high fidelity data from the start-up tests at the Barnwell Reprocessing Facility is in recovery. This paper details the data sets and compares their relative attributes.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Polymer Electrolyte-Based Ambient Temperature Oxygen Microsensors for Environmental Monitoring

An ambient temperature oxygen microsensor, based on a Nafion polymer electrolyte, has been developed and was microfabricated using thin-film technologies. A challenge in the operation of Nafion-based sensor systems is that the conductivity of Nafion film depends on the humidity in the film. Nafion film loses conductivity when the moisture content in the film is too low, which can affect sensor operation. The advancement here is the identification of a method to retain the operation of the Nafion films in lower humidity environments. Certain salts can hold water molecules in the Nafion film structure at room temperature. By mixing salts with the Nafion solution, water molecules can be homogeneously distributed in the Nafion film increasing the film s hydration to prevent Nafion film from being dried out in low-humidity environment. The presence of organics provides extra sites in the Nafion film to promote proton (H+) mobility and thus improving Nafion film conductivity and sensor performance. The fabrication of ambient temperature oxygen microsensors includes depositing basic electrodes using noble metals, and metal oxides layer on one of the electrode as a reference electrode. The use of noble metals for electrodes is due to their strong catalytic properties for oxygen reduction. A conducting polymer Nafion, doped with water-retaining components and extra sites facilitating proton movement, was used as the electrolyte material, making the design adequate for low humidity environment applications. The Nafion solution was coated on the electrodes and air-dried. The sensor operates at room temperature in potentiometric mode, which measures voltage differences between working and reference electrodes in different gases. Repeat able responses to 21-percent oxygen in nitrogen were achieved using nitrogen as a baseline gas. Detection of oxygen from 7 to 21 percent has also been demonstrated. The room-temperature oxygen micro sensor developed has extremely low power consumption (no heating for operation, no voltage applied to the sensor, only a voltmeter is needed to measure the output), is small in size, is simple to batch-fabricate, and is high in sensor yield. It is applicable in a wide humidity range, with improved operation in low humidity after the additives were added to the Nafion film. Through further improvement and development, the sensor can be used for aerospace applications such as fuel leak detection, fire detection, and environmental monitoring.

Hunter, Gary W.↗

LDCM Ground System. Network Lesson Learned

This slide presentation reviews the Landsat Data Continuity Mission (LDCM) and the lessons learned in implementing the network that was assembled to allow for the acquisition, archiving and distribution of the data from the Landsat mission. The objective of the LDCM is to continue the acquisition, archiving, and distribution of moderate-resolution multispectral imagery affording global, synoptic, and repetitive coverage of the earth's land surface at a scale where natural and human-induced changes can be detected, differentiated, characterized, and monitored over time. It includes a review of the ground network, including a block diagram of the ground network elements (GNE) and a review of the RF design and testing. Also included is a listing of the lessons learned.

Gal-Edd, Jonathan↗

Autoradiography Using OSL for Monitoring Warhead Dismantlement

The use of radiation imaging techniques to provide increased confidence in a dismantlement verification regime is still under investigation. Currently, radiation measurements can be used to confirm attributes such as the presence, quality, and mass of containerized nuclear material. However, imaging techniques can be used to confirm the shape, size, and/or symmetry of the object being interrogated. Imaging can be used as a complementary technique to radiation measurements to confirm a declaration or as a chain of custody measure to confirm that an item has not been tampered with. As with other attribute measurements, the image data must be protected behind an information barrier and analyzed to give an unclassified result when compared to an agreed upon threshold. This paper will discuss the use of Optically Stimulated Luminescence to perform autoradiography of sources using coded apertures to differentiate between point sources and various distributed sources. The coded aperture chosen for this application is based on modified uniform redundant arrays (mURAs) which resulted in the design and manufacture of an efficient, high-resolution mURA mask/antimask system. The potential use of the autoradiography technique with the coded aperture as an intrinsic information barrier and the required protection of the mask and unfolding algorithm will also be discussed. This project has been supported by the US Department of Energy’s National Nuclear Security Administration’s Office of Dismantlement and Transparency (DOE/NNSA/NA-241).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Application Of ERT For Tracking CO2 Plume Growth And Movement At The SECARB Cranfield Site

Electrical Resistance Tomography (ERT) installed to track the development of an injected subsurface CO{sub 2} plume at the SECARB Cranfield, MS. sequestration site will be the deepest subsurface application of this method to date. ERT utilizes vertical arrays of electrodes, usually in a cross-well arrangement, to perform four-electrode measurements of changes in the spatial distribution of electrical resistance within a subsurface formation. Because a formation containing super-critical CO{sub 2} is approximately five times as resistive as its surroundings, significant resistance changes are anticipated during plume growth and movement within a brine-filled formation. ERT has also been shown to be quite sensitive to CO{sub 2} saturation changes. The Cranfield ERT electrode arrays will be emplaced at a depth exceeding 10,000 ft. (3280 m); the system design and installation must address significant challenges associated with both the depth and borehole conditions including temperatures of 258 F (126 C), pressures exceeding 5000 psi and a groundwater pH of 3. In addition, the system must allow co-located emplacement and concurrent operation with other monitoring techniques that utilize the same boreholes. ERT electrode and cabling will be attached to the outside of the well casing, allowing free access to the interior of the well, which is required by some of the other monitoring techniques being fielded. We will highlight these design challenges along with preliminary simulations indicating the anticipated level of imaging and the advantages of applying the technique in conjunction with other methods (such as cross-well seismics) to more accurately track the properties, location and movement of CO{sub 2} plumes.

54 ENVIRONMENTAL SCIENCES↗

SU-E-J-72: Geant4 Simulations of Spot-Scanned Proton Beam Treatment Plans

Purpose: To evaluate density inhomogeneities which can effect dose distributions for real-time image gated spot-scanning proton therapy (RGPT), a dose calculation system, using treatment planning system VQA (Hitachi Ltd., Tokyo) spot position data, was developed based on Geant4. Methods: A Geant4 application was developed to simulate spot-scanned proton beams at Hokkaido University Hospital. A CT scan (0.98 × 0.98 × 1.25 mm) was performed for prostate cancer treatment with three or four inserted gold markers (diameter 1.5 mm, volume 1.77 mm3) in or near the target tumor. The CT data was read into VQA. A spot scanning plan was generated and exported to text files, specifying the beam energy and position of each spot. The text files were converted and read into our Geant4-based software. The spot position was converted into steering magnet field strength (in Tesla) for our beam nozzle. Individual protons were tracked from the vacuum chamber, through the helium chamber, steering magnets, dose monitors, etc., in a straight, horizontal line. The patient CT data was converted into materials with variable density and placed in a parametrized volume at the isocenter. Gold fiducial markers were represented in the CT data by two adjacent voxels (volume 2.38 mm3). 600,000 proton histories were tracked for each target spot. As one beam contained about 1,000 spots, approximately 600 million histories were recorded for each beam on a blade server. Two plans were considered: two beam horizontal opposed (90 and 270 degree) and three beam (0, 90 and 270 degree). Results: We are able to convert spot scanning plans from VQA and simulate them with our Geant4-based code. Our system can be used to evaluate the effect of dose reduction caused by gold markers used for RGPT. Conclusion: Our Geant4 application is able to calculate dose distributions for spot scanned proton therapy.

07 ISOTOPE AND RADIATION SOURCES↗

NASA Tech Briefs, December 2007

Topics include: Ka-Band TWT High-Efficiency Power Combiner for High-Rate Data Transmission; Reusable, Extensible High-Level Data-Distribution Concept; Processing Satellite Imagery To Detect Waste Tire Piles; Monitoring by Use of Clusters of Sensor-Data Vectors; Circuit and Method for Communication Over DC Power Line; Switched Band-Pass Filters for Adaptive Transceivers; Noncoherent DTTLs for Symbol Synchronization; High-Voltage Power Supply With Fast Rise and Fall Times; Waveguide Calibrator for Multi-Element Probe Calibration; Four-Way Ka-Band Power Combiner; Loss-of-Control-Inhibitor Systems for Aircraft; Improved Underwater Excitation-Emission Matrix Fluorometer; Metrology Camera System Using Two-Color Interferometry; Design and Fabrication of High-Efficiency CMOS/CCD Imagers; Foam Core Shielding for Spacecraft CHEM-Based Self-Deploying Planetary Storage Tanks Sequestration of Single-Walled Carbon Nanotubes in a Polymer PPC750 Performance Monitor Application-Program-Installer Builder Using Visual Odometry to Estimate Position and Attitude Design and Data Management System Simple, Script-Based Science Processing Archive Automated Rocket Propulsion Test Management Online Remote Sensing Interface Fusing Image Data for Calculating Position of an Object Implementation of a Point Algorithm for Real-Time Convex Optimization Handling Input and Output for COAMPS Modeling and Grid Generation of Iced Airfoils Automated Identification of Nucleotide Sequences Balloon Design Software Rocket Science 101 Interactive Educational Program Creep Forming of Carbon-Reinforced Ceramic-Matrix Composites Dog-Bone Horns for Piezoelectric Ultrasonic/Sonic Actuators Benchtop Detection of Proteins Recombinant Collagenlike Proteins Remote Sensing of Parasitic Nematodes in Plants Direct Coupling From WGM Resonator Disks to Photodetectors Using Digital Radiography To Image Liquid Nitrogen in Voids Multiple-Parameter, Low-False-Alarm Fire-Detection Systems Mosaic-Detector-Based Fluorescence Spectral Imager Plasmoid Thruster for High Specific-Impulse Propulsion Analysis Method for Quantifying Vehicle Design Goals Improved Tracking of Targets by Cameras on a Mars Rover Sample Caching Subsystem Multistage Passive Cooler for Spaceborne Instruments GVIPS Models and Software Stowable Energy-Absorbing Rocker-Bogie Suspensions

Source record↗

Hardware and Software Engineering

The Launch Control System (LCS) is a part of the system used to launch the Space Launch System (SLS). It monitors and control of both vehicle and ground systems for SLS. My internship this spring was focused both on the hardware and software aspects of the command and control system. During my internship I worked in two groups, the Record and Playback Subsystem (RPS) and Kennedy Ground Control Subsystems (KGCS). During my time on RPS, I worked on automating the updating of displays and engineering reports. While on KGCS I worked on creating a power distribution diagram of the Control System Development Lab (CDL) and a new trainer for new interns or employees to gain an understanding of Programmable Logic Controllers (PLCs).

Hardware↗

Compact Nanoparticle Size Distribution Measurement System for Unmanned Aerial Systems (UAS)

Brechtel Manufacturing Incorporated (BMI) is developing a compact, nanoparticle sizer optimized for use on Unmanned Aerial Vehicles (UAVs) and other applications where space, weight, power and cost are significant barriers to deployment. The instrument will allow observations of size-resolved aerosol number concentration (0.005 < D p < 0.3 μm, D p is particle diameter). The new development helps address the need for reduced uncertainties in atmospheric radiative transfer and weather prediction model sensitivities to ambient aerosol properties by promoting the capability to perform aerosol measurements more often, in more locations, and at reduced cost. Applications of the new technology include vertical atmospheric profiling with UAVs, balloons and other mobile platforms to constrain weather forecast models, long-term air quality measurements, aerosol health effects studies, and routine monitoring of ambient aerosol properties in urban air sheds.

47 OTHER INSTRUMENTATION↗