Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “distributed system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Monitoring system and methods for a distributed and recoverable digital control system

A monitoring system and methods are provided for a distributed and recoverable digital control system. The monitoring system generally comprises two independent monitoring planes within the control system. The first monitoring plane is internal to the computing units in the control system, and the second monitoring plane is external to the computing units. The internal first monitoring plane includes two in-line monitors. The first internal monitor is a self-checking, lock-step-processing monitor with integrated rapid recovery capability. The second internal monitor includes one or more reasonableness monitors, which compare actual effector position with commanded effector position. The external second monitor plane includes two monitors. The first external monitor includes a pre-recovery computing monitor, and the second external monitor includes a post recovery computing monitor. Various methods for implementing the monitoring functions are also disclosed.

Stange, Kent↗

Estimation of discontinuous coefficients in parabolic systems: Applications to reservoir simulation

Spline based techniques for estimating spatially varying parameters that appear in parabolic distributed systems (typical of those found in reservoir simulation problems) are presented. The problem of determining discontinuous coefficients, estimating both the functional shape and points of discontinuity for such parameters is discussed. Convergence results and a summary of numerical performance of the resulting algorithms are given.

Lamm, P. D.↗

Biofilm formation and control in a simulated spacecraft water system - Interim results

The ability of iodine to control microbial contamination and biofilm formation in spacecraft water distribution systems is studied using two stainless steel water subsystems. One subsystem has an iodine level of 2.5 mg/L maintained by an iodinated ion-exchange resin. The other subsystem has no iodine added. Stainless steel coupons are removed from each system to monitor biofilm formation. Results from the first six months of operation indicate that 2.5 mg/L of iodine has limited the number of viable bacteria that can be recovered from the iodinated subsystem. Epifluorescence microscopy of the coupons taken from this subsystem, however, indicates some evidence of microbial colonization after 15 weeks of operation. Numerous bacteria have been continually removed from both the water samples and the coupons taken from the noniodinated subsystem after only 3 weeks of operation.

Schultz, John R.↗

Case Study of an Object-Oriented System: EOSDIS

Mission to Planet Earth (MTPE) is a long-term NASA research mission to study the processes leading to global climate change. The Earth Observing System (EOS) is a NASA campaign of satellite observatories that are a major component of MTPE. The EOS Data and Information System (EOSDIS) is another component of MTPE that will provide the Earth science community with easy, affordable, and reliable access to Earth science data. EOSDIS is a distributed system, with major facilities at six Distributed Active Archive Centers (DAACS) located throughout the United States. The EOSDIS software architecture is being designed to receive, process, and archive several terabytes of science data on a daily basis. Thousands of science users and perhaps several hundred thousands of non-science users are expected to access the system. While there are many segments in EOSDIS (e.g., flight operations, network) this case study discusses the development of the science data processing segment (SDPS). We briefly review the architecture of the system, the goals of the SDPS, and the development progress to date. This study highlights key software development challenges, experiences integrating COTS, and the difficulties of managing a complex system development effort.

Behnke, Jeanne↗

PCLIPS

CLIPS is an expert system, created specifically to allow rapid implementation of an expert system. CLIPS is written in C, and thus needs a very small amount of memory to run. Parallel CLIPS (PCLIPS) is an extension to CLIPS which is intended to be used in situations where a group of expert systems are expected to run simultaneously and occasionally communicate with each other on an integrated network. PCLIPS is a coarse-grained data distribution system. Its main goal is to take information in one knowledge base and distribute it to other knowledge bases so that all the executing expert systems are able to use that knowledge to solve their disparate problems.

Krolak, Patrick D.↗

Analyzing at-scale distribution grid response to extreme temperatures

Threats against power grids continue to increase, as extreme weather conditions and natural disasters (extreme events) become more frequent. Hence, there is a need for the simulation and modeling of power grids to reflect realistic conditions during extreme events conditions, especially distribution systems. Herein, this paper presents a modeling and simulation platform for electric distribution grids which can estimate overall power demand during extreme weather conditions. The presented platform's efficacy is shown by demonstrating estimation of electrical demand for 1) Electricity Reliability Council of Texas (ERCOT) during winter storm Uri in 2021, and 2) alternative hypothetical scenarios of integrating Distributed Energy Resources (DERs), weatherization, and load electrification. In comparing to the actual demand served by ERCOT during the winter storm Uri of 2021, the proposed platform estimates approximately 34 GW of peak capacity deficit. These numbers are consistent with state-of-the-art prediction results published in the literature. For the case of the future electrification of heating loads, peak capacity of 78 GW (124% increase) is estimated, which would be reduced to 47 GW (38% increase) with the adoption of efficient heating appliances and improved thermal insulation. Integrating distributed solar PV and storage into the grid causes improvement in the local energy utilization and hence reduces the potential unmet energy by 31% and 40%, respectively.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Security Enhancement of Network Constraint Grid-Edge Energy Management System

Network constrained grid edge energy management system (EMS) provides economic solution for active and reactive power dispatch of distributed energy resources (DERs) at the grid edge level. Grid edge EMS ensures secure interconnection of a circuit segment to the distribution system by maintaining grid code requirements (e.g. IEEE 1547–2018). Grid edge EMS is dependent on communication to receive load measurement, which brings a risk of unobservable false data injection attacks (FDIAs). To mitigate the risk, this paper proposes a framework to enhance resilient operation of grid edge EMS by detecting the unobservable FDIAs on loads and replacing them with forecasted values. In this work, a two-step detection algorithm is proposed. In first step, conventional residual based algorithm is deployed. Autoencoder (AE) based data driven mechanism is included in second step to detect the presence of unobservable FDIAs. After ensuring the presence of FDIA, its specific location is detected by checking the maximum residue values till the predefined threshold value is reached. Detected false data injected loads are then replaced with forecasted load values following long-short term memory (LSTM) based forecast to ensure resilient performance of grid edge EMS in the presence of attacks. This proposed security enhancement framework for grid edge EMS is evaluated in IEEE 13 bus system with three integrated DERs. Numerical simulation shows the validation of the proposed framework by reducing voltage violation in real operation of grid edge EMS.

cyber attack detection↗

Equitable Transactive Market Design to Coordinate Networked Microgrids with Mixed Ownership

This paper presents an inter-microgrid peer-topeer (P2P) transactive market mechanism to support the coordination of multiple microgrids in a mixed-ownership environment, while enabling prosumers to actively participate in the market to get their own benefits. An equitable P2P transactive energy market is designed, in which the energy burden to customers within microgrids is fairly distributed by leveraging a peer-to-peer communication network among MG owners and the distribution system operator (DSO). To reach the market settlement, a consensus-based distributed optimization algorithm is introduced to enable each MG owner and the DSO to distributedly determine the cleared price which is compensated by a household-income-based discount factor to encourage the energy-burden equity among customers in networked microgrids service territory. Numerical results on the modified 123 node test feeder including 6 microgrids are used to demonstrate the operation of the introduced equitable transactive energy market.

Vu, Thanh Long↗

Reinforcement Learning for Distribution Grid Optimization (PyCIGAR) v0.1

PyCIGAR is a python software package that merges off-the-shelf reinforcement learning libraries (RLLib and Ray) with electric power distribution system simulation tools (OpenDSS and a custom power flow solver built by LBL). PyCIGAR enables the training of neural networks to optimize the behavior of different components in the electric distribution grid, such as control systems in photovoltaic rooftop solar inverters and electric battery storage systems. The software package has been used to train neural networks to update settings in photovoltaic rooftop solar inverter control systems to mitigate cyber attacks on other solar photovoltaic rooftop devices.

Arnold, Daniel↗

Hydrogen fueled-hydrogen transport rail system - A NASA proposal

The technical possibility of fueling motive power equipment with hydrogen as an alternative to petroleum is studied, and the economics of operating hydrogen-fueled systems are evaluated. Technical considerations include the areas of fuel storage and distribution systems, engine design changes, and a test and evaluation program. A conversion methodology, which conforms to the scheme of high-pressure injection of hydrogen directly into the cylinder late in the compresssion stroke and injection of pilot diesel fuel for ignition, is illustrated with detailed diagrams.

Bain, A. L.↗

Status of space station power system

The major requirements and guidelines that affect the manned space station configuration and the power systems are explained. The evolution of the space station power system from the NASA program development feasibility phase through the current preliminary design phase is described. Several early station concepts are described and linked to the present concept. The recently completed phase B tradeoff study selections of photovoltaic system technologies are described. The present solar dynamic and power management and distribution systems are also summarized for completeness.

Baraona, Cosmo R.↗

Auxiliary propulsion technology for advanced Earth-to-orbit vehicles

The payload which can be delivered to orbit by advanced Earth-to-Orbit vehicles is significantly increased by advanced subsystem technology. Any weight which can be saved by advanced subsystem design can be converted to payload at Main Engine Cut Off (MECO) given the same launch vehicle performance. The auxiliary propulsion subsystem and the impetus for the current hydrogen/oxygen technology program is examined. A review of the auxiliary propulsion requirements of advanced Earth-to-Orbit (ETO) vehicles and their proposed missions is given first. Then the performance benefits of hydrogen/oxygen auxiliary propulsion are illustrated using current shuttle data. The proposed auxiliary propulsion subsystem implementation includes liquid hydrogen/liquid oxygen (LH2/LO2) primary Reaction Control System (RCS) engines and gaseous hydrogen/gaseous oxygen (GH2/GO2) vernier RCS engines. A distribution system for the liquid cryogens to the engines is outlined. The possibility of providing one dual-phase engine that can operate on either liquid or gaseous propellants is being explored, as well as the simultaneous firing of redundant primary RCS thrusters to provide Orbital Maneuvering System (OMS) level impulse. Scavenging of propellants from integral main engine tankage is proposed to utilize main engine tank residuals and to combine launch vehicle and subsystem reserves.

Schneider, Steven J.↗

Launch Processing System operations with a future look to Operations Analyst (OPERA)

The Launch Processing System architecture and the ground support operations required to provide Shuttle System engineers with the capability to safely process and launch an Orbiter are described. The described ground operations are the culmination of eleven years of experience and redesign. Some of the 'lessons learned' are examined, and problem areas which ground support operations have identified over the years as the Shuttle and Launch Processing Systems continue to grow in complexity are discussed. The Operational Analyst for Distributed Systems (OPERA), a proposed set of expert systems for the Launch Processing System Operational assistance, is discussed along with its extensions to prospective future configurations and components for the Launch Processing System.

Heard, Astrid E.↗

Status of the Space Station power system

The major requirements and guidelines that affect the manned Space Station configuration and the power systems are explained. The evolution of the Space Station power system from the NASA program development feasibility phase through the current preliminary design phase is described. Several early station concepts are described and linked to the present concept. The recently completed phase B tradeoff study selections of photovoltaic system technologies are described. The present solar dynamic and power management and distribution systems are also summarized for completeness.

Baraona, Cosmo R.↗

Data system overview

The data system architecture design philosophy for 'SFOC', which is a large-scale distributed system for support of current and future space missions at the JPL, stresses 'design for change' standardization that will permit software-reuse, periodic hardware-changeout, and network-configuration evolution. Multimission capabilities are supported through a buildup of the baseline system with a minimum of special-purpose adaptations. SFOC can accommodate multiple users representing multiple disciplines, and is capable of furnishing near-real time and nonrealtime support to end-users for downlink (telemetry) and uplink (command) functions.

Kahr, Joseph R.↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

Electric Propulsion Systems (Aircraft)↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

electric propulsion systems (aircraft) mission ana↗

Power System Options Evaluated for the Radiation and Technology Demonstration Mission

The Radiation and Technology Demonstration (RTD) Mission is under joint study by three NASA Centers: the NASA Johnson Space Center, the NASA Goddard Space Flight Center, and the NASA Glenn Research Center at Lewis Field. This Earth-orbiting mission, which may launch on a space shuttle in the first half of the next decade, has the primary objective of demonstrating high-power electric thruster technologies. Secondary objectives include better characterization of Earth's Van Allen trapped-radiation belts, measurement of the effectiveness of the radiation shielding for human protection, measurement of radiation effects on advanced solar cells, and demonstration of radiation-tolerant microelectronics. During the mission, which may continue up to 1 year, the 2000-kg RTD spacecraft will first spiral outward from the shuttle-deployed, medium-inclination, low Earth orbit. By the phased operation of a 10-kW Hall thruster and a 10-kW Variable Specific Impulse Magneto-Plasma Rocket, the RTD spacecraft will reach a low-inclination Earth orbit with a radius greater than five Earth radii. This will be followed by an inward spiraling orbit phase when the spacecraft deploys 8 to 12 microsatellites to map the Van Allen belts. The mission will conclude in low Earth orbit with the possible retrieval of the spacecraft by the space shuttle. A conceptual RTD spacecraft design showing two photovoltaic (PV) array wings, the Hall thruster with propellant tanks, and stowed microsatellites is presented. Early power system studies assessed five different PV array design options coupled with a 120-Vdc power management and distribution system (PMAD) and secondary lithium battery energy storage. Array options include (1) state-of-the-art 10-percent efficient three-junction amorphous SiGe thin-film cells on thin polymer panels deployed with an inflatable (or articulated) truss, (2) SCARLET array panels, (3) commercial state-of-the-art, planar PV array rigid panels with 25-percent efficient, three-junction GaInP2/GaAs/Ge solar cells, (4) rigid panels with 25-percent efficient, three-junction GaInP2/GaAs/Ge solar cells, in a 2 -concentrator trough configuration, and (5) thin polymer panels with 25-percent efficient, three-junction GaInP2/GaAs/Ge solar cells deployed with an inflatable (or articulated) truss. To assess the relative merits of these PV array design options, the study group developed a dedicated Fortran code to predict power system performance and estimate system mass. This code also modeled Earth orbital environments important for accurately predicting PV array performance. The most important environmental effect, solar cell radiation degradation, was calculated from electron-proton fluence input from the industry standard AE8/AP8 trapped radiation models and the concept of damage equivalence. Power systems were sized to provide 10 kW of thruster power and approximately 1 kW of spacecraft power at end of life. Of the five PV array design options, the option 1 (thin-film cells) power system was the most massive 590 kg, whereas the option 4 (trough concentrator) power system was the lightest 260 kg. Arguably, the lowest cost would come from the option 3 (commercial array panels) power system with an acceptable, albeit greater, system mass of 320 kg. Predicted power system performance during the spiral-out mission phase is shown the preceding graph for the option 5 (flexible-panel) array. From the results, the radiation-induced power loss over time is evident as the spacecraft slowly spirals outward through the trapped proton belt. The importance of the spiral trip time is also evident in the two curves representing 74-day and 182-day spiral-out periods. The longer spiral time introduces a beginning-of-life power oversizing penalty greater than 1 kW. Future studies will analyze power system performance and mass with a 50-Vdc power management and distribution architecture favorable to the VASIMR thruster and longer missions.

Kerslake, Thomas W.↗