Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The Vital Function of Fe3O4@Au nanocomposites for Hydrolase Biosensor Design and Its Application in Detection of Methyl Parathion

A nanocomposite of gold nanoparticles (AuNPs) decorating a magnetic Fe3O4 core was synthesized using cysteamine (SH–NH2) as linker, and characterized by TEM, XPS, UV and electrochemistry. Then a hydrolase biosensor, based on self-assembly of methyl parathion hydrolase (MPH) on the Fe3O4@Au nanocomposite, was developed for sensitive and selective detection of the organophosphorus pesticide (OP) methyl parathion. The magnetic nanocomposite provides an easy way to construct the enzyme biosensor by simply exerting an external magnetic field, and also provides a simple way to renew the electrode surface by removing the magnet. Unlike inhibition-based enzyme biosensors, the hydrolase is not poisoned by OPs and thus is reusable for continuous measurement. AuNPs not only provide a large surface area, high loading efficiency and fast electron transfer, but also stabilize the enzyme through electrostatic interactions. The MPH biosensor shows rapid response and high selectivity for detection of methyl parathion, with a linear range from 0.5 to 1000 ng/mL and a detection limit of 0.1 ng/mL. It also shows acceptable reproducibility and stability. The simplicity and ease of operation of the proposed method has great potential for on-site detection of P–S containing pesticides and provides a promising strategy to construct a robust biosensor.

Au nanoparticles↗

Assembly of polythiophenes on responsive polymer microgels for the highly selective detection of ammonia gas

For this study, a class of smart composite materials based on the assembly of conjugated polymers on responsive polymer microgels has been prepared. We have chosen poly(3-((2-(2-methoxyethoxy)ethoxy)methyl)-thiophene) as the model conjugated polymer and an ammonia-responsive microgel of phenoxazinium-functionalized poly(N-isopropylacrylamide-co-propargyl acrylate) as the model template. Under this design, the composite materials can combine the electrical conductivity of the conjugated polymers and the ammonia recognisability of the ammonia-responsive polymer microgels; the cooperation of these properties allows the reversible control of electrical conductivity by ammonia gas. Those composite materials can not only adapt to ammonia gas, but also convert changes in the concentration of ammonia into conductance, allowing the electrical detection of ammonia gas with high selectivity. This makes the composite materials different from the conductive polymer platforms reported previously, which may also respond to non-ammonia gases and the response induced by non-ammonia gases is close to that induced by ammonia gas. Using these composite materials as sensing materials for the electrical detection of ammonia gas, the detection limit can reach as low as 1.1 ppb. Finally, these features enable their use for the electrical detection of ammonia in breath.

36 MATERIALS SCIENCE↗

TDCOSMO. VII. Boxyness/discyness in lensing galaxies: Detectability and impact on H 0

In the context of gravitational lensing, the density profile of lensing galaxies is often considered to be perfectly elliptical. Potential angular structures are generally ignored, except to explain flux ratios of point-like sources (i.e. flux ratio anomalies). Surprisingly, the impact of azimuthal structures on extended images of the source has not been characterised, nor has its impact on the H 0 inference. We address this task by creating mock images of a point source embedded in an extended source and lensed by an elliptical galaxy on which multipolar components are added to emulate boxy or discy isodensity contours. Modelling such images with a density profile free of angular structure allows us to explore the detectability of image deformation induced by the multipoles in the residual frame. Multipole deformations are almost always detectable for our highest signal-to-noise ratio (S/N) mock data. However, the detectability depends on the lens ellipticity and Einstein radius, on the S/N of the data, and on the specific lens modelling strategy. Multipoles also introduce small changes to the time-delays. We therefore quantify how undetected multipoles would impact H 0 inference. When no multipoles are detected in the residuals, the impact on H 0 for a given lens is in general less than a few k ms -1 Mpc -1 , but in the worst-case scenario, combining low S/N in the ring and large intrinsic boxyness or discyness, the bias on H0 can reach 10-12 km s -1 Mpc -1 . If we now look at the inference on H 0 from a population of lensing galaxies with a distribution of multipoles representative of what is found in the light profile of elliptical galaxies, we find a systematic bias on H 0 of less than 1%. A comparison of our mock systems to the state-of-the-art time-delay lens sample studied by the H0LiCOW and TDCOSMO collaborations indicates that multipoles are currently unlikely to be a source of substantial systematic bias on the inferred value of H 0 from time-delay lenses.

79 ASTRONOMY AND ASTROPHYSICS↗

Early photometric and spectroscopic observations of the extraordinarily bright INTEGRAL-detected GRB 221009A

Context. GRB 221009A, initially detected as an X-ray transient by Swift, was later revealed to have triggered the Fermi satellite about an hour earlier, marking it as a post-peak observation of the event’s emission. This GRB distinguished itself as the brightest ever recorded, presenting an unparalleled opportunity to probe the complexities of GRB physics. The unprecedented brightness, however, challenged observation efforts, as it led to the saturation of several high-energy instruments.Aims. Our study seeks to investigate the nature of the INTEGRAL-detected GRB 221009A and elucidate the environmental conditions conducive to these exceptionally powerful bursts. Moreover, we aim to understand the fundamental physics illuminated by the detection of teraelectronvolt (TeV) photons emitted by GRB 221009A.Methods. We conducted detailed analyses of early photometric and spectroscopic observations that span from the Fermi trigger through to the initial days following the prompt emission phase in order to characterize GRB 221009A’s afterglow, and we complemented these analyses with a comparative study.Results. Our findings from analyzing INTEGRAL data confirm GRB 221009A as the most energetic event observed to date. Early optical observations during the prompt phase negate the presence of bright optical emissions with internal or external shock origins. Spectroscopic analyses enabled us to measure GRB 221009A’s distance and line-of-sight properties. The afterglow’s temporal and spectral analysis suggests prolonged activity of the central engine and a transition in the circumburst medium’s density. Finally, we discuss the implications for fundamental physics of detecting photons as energetic as 18 TeV from GRB 221009A.Conclusions. Early optical observations have proven invaluable for distinguishing between the potential origins of optical emissions in GRB 221009A, underscoring their utility in GRB physics studies. However, the rarity of such data underscores the need for dedicated telescopes capable of synchronous multiwavelength observations. Additionally, our analysis suggests that the host galaxies of TeV GRBs share commonalities with those of long and short GRBs. Expanding the sample of TeV GRBs could further solidify these findings.Key words: techniques: photometric / techniques: spectroscopic / gamma-ray burst: general / gamma-ray burst: individual: GRB 221009A

79 ASTRONOMY AND ASTROPHYSICS↗

Anomaly Detection Based on Machine Learning for the CMS Electromagnetic Calorimeter Online Data Quality Monitoring

Using a semi-supervised machine learning approach we present a real-time anomaly detection system based on an autoencoder used for online data quality monitoring of the CMS electromagnetic calorimeter operating at the CERN LHC. We introduce a novel method that maximizes the anomaly detection performance making use of the time-dependence of anomalies and the spatial variations in the detector response. The autoencoder-based system efficiently detects anomalies in real time and maintains a very low false discovery rate. We validate the performance of this novel system with anomalies from LHC collision data taken in 2018 and 2022. In addition, results are presented after deploying the autoencoder-based system in the CMS online Data Quality Monitoring workflow at the beginning of LHC Run 3 resulting in the system to detect issues that were missed by the existing system.

Harilal, Abhirami [Carnegie Mellon University, Pit↗

Methodological demonstration of laser beam pointing control for space gravitational wave detection missions

In space laser interferometer gravitational wave (G.W.) detection missions, the stability of the laser beam pointing direction has to be kept at 10 nrad/√Hz. Otherwise, the beam pointing jitter noise will dominate the noise budget and make the detection of G.W. impossible. Disturbed by the residue non-conservative forces, the fluctuation of the laser beam pointing direction could be a few μrad/√Hz at frequencies from 0.1 mHz to 10 Hz. Therefore, the laser beam pointing control system is an essential requirement for those space G.W. detection missions. An on-ground test of such beam pointing control system is performed, where the Differential Wave-front Sensing technique is used to sense the beams pointing jitter. An active controlled steering mirror is employed to adjust the beam pointing direction to compensate the jitter. The experimental result shows that the pointing control system can be used for very large dynamic range up to 5 μrad. At the interested frequencies of space G.W. detection missions, between 1 mHz and 1 Hz, beam pointing stability of 6 nrad/√Hz is achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detecting vapour bubbles in simulations of metastable water

The investigation of cavitation in metastable liquids with molecular simulations requires an appropriate definition of the volume of the vapour bubble forming within the metastable liquid phase. Commonly used approaches for bubble detection exhibit two significant flaws: first, when applied to water they often identify the voids within the hydrogen bond network as bubbles thus masking the signature of emerging bubbles and, second, they lack thermodynamic consistency. Here, we present two grid-based methods, the M-method and the V-method, to detect bubbles in metastable water specifically designed to address these shortcomings. The M-method incorporates information about neighbouring grid cells to distinguish between liquid- and vapour-like cells, which allows for a very sensitive detection of small bubbles and high spatial resolution of the detected bubbles. The V-method is calibrated such that its estimates for the bubble volume correspond to the average change in system volume and are thus thermodynamically consistent. Both methods are computationally inexpensive such that they can be used in molecular dynamics and Monte Carlo simulations of cavitation. We illustrate them by computing the free energy barrier and the size of the critical bubble for cavitation in water at negative pressure.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Design of electric-field assisted surface plasmon resonance system for the detection of heavy metal ions in water

Surface Plasmon Resonance (SPR) sensors are widely used in diverse applications. For detecting heavy metal ions in water, surface functionalization of the metal surface is typically used to adsorb target molecules, where the ionic concentration is detected via a resonance shift (resonance angle, resonance wavelength or intensity). This paper studies the potential of a possible alternative approach that could eliminate the need of using surface functionalization by the application of an external electric field in the flow channel. The exerted electrical force on the ions pushes them against the surface for enhanced adsorption; hence it is referred to as “Electric-Field assisted SPR system”. High system sensitivity is achieved by monitoring the time dynamics of the signal shift. The ion deposition dynamics are discussed using a derived theoretical model based on ion mobility in water. On the application of an appropriate force, the target ions stack onto the sensor surface depending on the ionic concentration of target solution, ion mass, and flow rate. In the experimental part, a broad detection range of target cadmium ions (Cd{sup 2+}) in water from several parts per million (ppm) down to a few parts per billion (ppb) can be detected.

36 MATERIALS SCIENCE↗

Centrifugal sedimentation immunoassays for multiplexed detection of enteric bacteria in ground water

Water-born pathogens pose significant threat to the global population and early detection plays an important role both in making drinking water safe, as well as in diagnostics and treatment of water-borne diseases. We present an innovative centrifugal microfluidic platform (SpinDx) for detection of bacterial pathogens using bead-based immunoassays. Our approach is based on binding of pathogens to antibody-functionalized capture particles followed by sedimentation of the particles through a density-media in a microfluidic disk and quantification by fluorescence microscopy. Our platform is fast (20 min), sensitive (10 3 CFU/mL), requires minimal sample preparation, and can detect multiple pathogens simultaneously with sensitivity similar to that required by the EPA. We demonstrate detection of a panel of enteric bacteria (Escherichia coli, Salmonella typhimurium, Shigella, Listeria, and Campylobacter) at concentrations as low as 10 3 CFU/mL or 30 bacteria per reaction.

59 BASIC BIOLOGICAL SCIENCES↗

Thin film organic photodetectors for indirect X-ray detection demonstrating low dose rate sensitivity at low voltage operation

Here, developments in the field of organic semiconductors have generated organic photodetectors with high quantum efficiency, wide spectral sensitivity, low power consumption, and unique form factors that are flexible and conformable to their substrate shape. In this work, organic photodetectors coupled with inorganic CsI(Tl) scintillators are used to showcase the low dose rate sensitivity that is enabled when high performance organic photodetectors and scintillator crystals are integrated. The detection capability of these organic-inorganic coupled systems to high energy radiation highlights their potential as an alternative to traditional photomultiplier tubes for nuclear spectroscopy applications. When exposed to Bremsstrahlung radiation produced from an X-ray generator, SubPc:C 60 , AlPcCl:C 70 , and P3HT:PC 61 BM thin film photodetectors with active layer thicknesses less than 100 nm show detection of incident radiation at low and no applied bias. Remarkably low dose rates, down to at least 0.28 µGy/s, were detectable with a characteristic linear relationship between exposure rate and photodetector current output. These devices also demonstrate sensitivities as high as 5.37 mC Gy -1 cm -2 when coupled to CsI(Tl). Additionally, as the tube voltage across the X-ray generator was varied, these organic-inorganic systems showed their ability to detect a range of continuous radiation spectra spanning several hundred keV.

36 MATERIALS SCIENCE↗

Phase modulation failsafe system for multi-kJ lasers based on optical heterodyne detection

Amplification of the transverse scattered component of stimulated Brillouin scattering (SBS) can contribute to optical damage in the large aperture optics of multi-kJ lasers. Because increased laser bandwidth from optical phase modulation (PM) can suppress SBS, high energy laser amplifiers are injected with PM light. Phase modulation distributes the single-frequency spectrum of a master oscillator laser among individual PM sidebands, so a sufficiently high modulation index β can maintain the fluence for all spectral components below the SBS threshold. To avoid injection of single frequency light in the event of a PM failure, a high-speed PM failsafe system (PMFS) must be employed. Because PM is easily converted to AM, essentially all PM failsafes detect AM, with the one described here employing a novel configuration where optical heterodyne detection converts PM to AM, followed by passive AM power detection. Although the PMFS is currently configured for continuous monitoring, it can also detect PM for pulse durations ≥2 ns and could be modified to accommodate shorter pulses. This PMFS was deployed on the Z-Beamlet Laser (ZBL) at Sandia National Laboratories, as required by an energy upgrade to support programs at Sandia’s Z Facility such as magnetized liner inertial fusion. Depending on the origin of a PM failure, the PMFS responds in as little as 7 ns. In the event of an instantaneous failure during initiation of a laser shot, this response time translates to a 30–50 ns margin of safety by blocking a pulse from leaving ZBL’s regenerative amplifier, which prevents injection of single frequency light into the main amplification chain. In conclusion, the performance of the PMFS, without the need for operator interaction, conforms to the principles of engineered safety.

47 OTHER INSTRUMENTATION↗

Compact single-shot electro-optic detection system for THz pulses with femtosecond time resolution at MHz repetition rates

Electro-optical detection has proven to be a valuable technique to study temporal profiles of THz pulses with pulse durations down to femtoseconds. As the Coulomb field around a relativistic electron bunch resembles the current profile, electro-optical detection can be exploited for non-invasive bunch length measurements at accelerators. We have developed a very compact and robust electro-optical detection system based on spectral decoding for single-shot longitudinal bunch profile monitoring at the European X-ray Free Electron Laser (XFEL) for electron bunch lengths down to 200 fs (rms). Apart from the GaP crystal and the corresponding laser optics at the electron beamline, all components are housed in 19 in. chassis for rack mount and remote operation inside the accelerator tunnel. An advanced laser synchronization scheme based on radio-frequency down-conversion has been developed for locking a custom-made Yb-fiber laser to the radio-frequency of the European XFEL accelerator. In order to cope with the high bunch repetition rate of the superconducting accelerator, a novel linear array detector has been employed for spectral measurements of the Yb-fiber laser pulses at frame rates of up to 2.26 MHz. In this paper, we describe all sub-systems of the electro-optical detection system as well as the measurement procedure in detail and discuss the first measurement results of longitudinal bunch profiles of around 400 fs (rms) with an arrival-time jitter of 35 fs (rms).

47 OTHER INSTRUMENTATION↗

High efficiency hexagonal boron nitride neutron detectors with 1 cm 2 detection areas

We report the realization of 1 cm 2 hexagonal boron nitride (h-BN) thermal neutron detectors with an unprecedented detection efficiency of 59%. This was achieved through improvements in material quality, as reflected in a sixfold enhancement in the electron mobility and lifetime product and a threefold reduction in the surface recombination field, which resulted in a higher detection efficiency at a lower applied electric field over that of a previous state-of-the-art lateral detector with a detection area of 30 mm 2 . The attainment of 1 cm 2 h-BN neutron detectors capable of retaining a high detection efficiency represents a significant milestone toward the practical applications of h-BN detectors.

42 ENGINEERING↗

Early internal detection of magnetic tearing and implications for tokamak magnetohydrodynamic stability

Internal fluctuation measurements with Faraday-effect polarimetry in the DIII-D tokamak reveal the onset of a tearing mode with toroidal mode number n = 3 well before it is detected by the sensing coils external to the plasma. This mode appears before the n = 2, 1 modes and is first detected with internal measurements at a lower value of the ideal-wall kink beta limit than is indicated at the time of first detection by the sensing coils. When the mode is first detected, the linear resistive stability parameter, Δ′, indicates marginal stability and continues to do so until later when the mode amplitude begins increasing linearly with time—together suggesting a neoclassical origin for this mode.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Ultrawide bandgap semiconductor h-BN for direct detection of fast neutrons

III-nitride wide bandgap semiconductors have contributed on the grandest scale to many technological advances in lighting, displays, and power electronics. Among III-nitrides, BN has another unique application as a solid-state neutron detector material because the isotope B-10 is among a few elements that have an unusually large interaction cross section with thermal neutrons. A record high thermal neutron detection efficiency of 60% has been achieved by B-10 enriched h-BN detectors of 100 μm in thickness in our group. However, direct detection of fast neutrons with energies above 1 MeV is highly challenging due to the extremely low interaction cross section of fast neutrons with matter. We report the successful attainment of 0.4 mm thick freestanding h-BN 4"-diameter wafers, which enabled the demonstration of h-BN fast neutron detectors capable of delivering a detection efficiency of 2.2% in response to a bare AmBe neutron source. Furthermore, it was shown that the energy information of incoming fast neutrons is retained in the neutron pulse-height spectra. A comparison of characteristics between h-BN fast and thermal neutron detectors is summarized. Neutron detectors are vital diagnostic instruments for nuclear and fusion reactor power and safety monitoring, oil field exploration, neutron imaging and therapy, as well as for plasma and material science research. With the outstanding attributes resulting from its ultrawide bandgap (UWBG), including the ability to operate at extreme conditions of high power, voltage, and temperature, the availability of h-BN UWBG semiconductor detectors with the capability of simultaneously detecting thermal and fast neutrons with high efficiencies is expected to open unprecedented applications that are not possible to attain by any other types of neutron detectors.

36 MATERIALS SCIENCE↗

Ionization effects in single-shot carrier-envelope phase detection with gas-gap devices

The carrier-envelope phase (CEP) is a key parameter for attosecond waveform control of ultrashort laser pulses. For laser systems with high repetition rates, however, single-shot CEP detection is still challenging. Building on recent findings on phase detection with electric current generation in gases, we show that with an optimized detection method, a long-term stable single-shot phase detection is feasible. We investigate the achievable performance depending on various parameters such as pulse duration, gas pressure, or incident intensity. The latter exhibits a regime where the saturation of the ionization process boosts the phase sensitivity of the signal, which is elucidated by numerical calculations.

47 OTHER INSTRUMENTATION↗

Mineralogical effects on the detectability of the postperovskite boundary

The discovery of a phase transition in Mg-silicate perovskite (Pv) to postperovskite (pPv) at lowermost mantle pressure-temperature (P - T) conditions may provide an explanation for the discontinuous increase in shear wave velocity found in some regions at a depth range of 200 to 400 km above the core-mantle boundary, hereafter the D{double_prime} discontinuity. However, recent studies on binary and ternary systems showed that reasonable contents of Fe{sup 2+} and Al for pyrolite increase the thickness (width of the mixed phase region) of the Pv - pPv boundary (400-600 km) to much larger than the D{double_prime} discontinuity ({le} 70 km). These results challenge the assignment of the D{double_prime} discontinuity to the Pv - pPv boundary in pyrolite (homogenized mantle composition). Furthermore, the mineralogy and composition of rocks that can host a detectable Pv {yields} pPv boundary are still unknown. Here we report in situ measurements of the depths and thicknesses of the Pv {yields} pPv transition in multiphase systems (San Carlos olivine, pyrolitic, and midocean ridge basaltic compositions) at the P - T conditions of the lowermost mantle, searching for candidate rocks with a sharp Pv - pPv discontinuity. Whereas the pyrolitic mantle may not have a seismologically detectable Pv {yields} pPv transition due to the effect of Al, harzburgitic compositions have detectable transitions due to low Al content. In contrast, Al-rich basaltic compositions may have a detectable Pv - pPv boundary due to their distinct mineralogy. Therefore, the observation of the D{prime} discontinuity may be related to the Pv {yields} pPv transition in the differentiated oceanic lithosphere materials transported to the lowermost mantle by subducting slabs.

Grocholski, Brent↗

Detection efficiency of a water condensation particle counter using electrically neutral sulfuric acid and sulfuric acid-dimethylamine clusters

Recent advances in condensation particle counters (CPCs) have improved the detection of sub-3 nm particles, increasing the accuracy of new particle formation (NPF) measurements. However, the detection efficiencies for neutrally charged, atmospherically relevant, sub-1 nm particles, which are critical for the accurate derivation of atmospheric NPF rates, are currently unknown. Here, this study presents a method to measure the detection efficiency of sulfuric acid and clusters of sulfuric acid and dimethylamine using measured CPC concentrations and modeled cluster distributions at atmospherically relevant concentrations. This study finds that water-based CPCs can measure these clusters at detection efficiencies relevant to NPF studies.

Cheng, Darren [Carnegie Mellon Univ., Pittsburgh, ↗