Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

LOX cooled thrust chamber technology developments

An experimental LOX heat-transfer study and a LOX-cooled thrust-chamber demonstration program are summarized. Heat transfer to supercritical oxygen was investigated at 17 to 34.5 MPa (2460 to 5000 psia), and heat fluxes up to 90 MW/sq m (55 Btu/sq in.-sec). Experimental data obtained previously were correlated along with these recent data, and a design equation was derived which correlates 95% of the data within + or - 30%. Liquid-oxygen-cooled thrust chambers have been designed using this correlation and are currently being fabricated. A test program is planned for evaluating the LOX-cooled design concept using NASA test facilities. The purpose of these tests is to verify the LOX cooling correlation in a high-pressure liquid rocket engine and to determine the effects of a LOX coolant leak.

Spencer, R. G.↗

Effect of thermal barrier coatings on the performance of steam and water-cooled gas turbine/steam turbine combined cycle system

An analytical study was made of the performance of air, steam, and water-cooled gas-turbine/steam turbine combined-cycle systems with and without thermal-barrier coatings. For steam cooling, thermal barrier coatings permit an increase in the turbine inlet temperature from 1205 C (2200 F), resulting in an efficiency improvement of 1.9 percentage points. The maximum specific power improvement with thermal barriers is 32.4 percent, when the turbine inlet temperature is increased from 1425 C (2600 F) to 1675 C (3050 F) and the airfoil temperature is kept the same. For water cooling, the maximum efficiency improvement is 2.2 percentage points at a turbine inlet temperature of 1683 C (3062 F) and the maximum specific power improvement is 36.6 percent by increasing the turbine inlet temperature from 1425 C (2600 F) to 1730 C (3150 F) and keeping the airfoil temperatures the same. These improvements are greater than that obtained with combined cycles using air cooling at a turbine inlet temperature of 1205 C (2200 F). The large temperature differences across the thermal barriers at these high temperatures, however, indicate that thermal stresses may present obstacles to the use of coatings at high turbine inlet temperatures.

Nainiger, J. J.↗

Design and fabrication of a radiative actively cooled honeycomb sandwich panel

The mass of a radiative actively cooled panel was compared to the mass of a bare actively cooled panel designed to the same conditions and constraints. The approach was to design and optimize a 0.61 x 6.1 m full scale panel which combines radiative and active cooling to control structural temperatures to levels compatible with use of lightweight materials and to fabricate a 0.61 x 1.22 m panel for performance testing. Results of the design and optimization of the full scale radiative actively cooled structural panel, including radiative concept selection, final configuration details, test panel description, and conclusions are summarized.

Koch, L. C.↗

Liquid-cooling technology for gas turbines - Review and status

After a brief review of past efforts involving the forced-convection cooling of gas turbines, the paper surveys the state of the art of the liquid cooling of gas turbines. Emphasis is placed on thermosyphon methods of cooling, including those utilizing closed, open, and closed-loop thermosyphons; other methods, including sweat, spray and stator cooling, are also discussed. The more significant research efforts, design data, correlations, and analytical methods are mentioned and voids in technology are summarized.

Van Fossen, G. J., Jr.↗

Radiative cooling in shock-heated hydrogen-helium plasmas

Axial and off-axis radiative cooling of cylindrical shock-heated hydrogen-helium plasmas is investigated theoretically and experimentally. The coupled fluid dynamic-radiative transfer equations are solved by a combination of approximation techniques aimed at simplifying the computation of the flux divergence term, namely, the quasi-isothermal approximation and the exponential approximation developed for the solid angle integration. The accuracy of the approximation schemes has been assessed and found acceptable for applying the methods to the rapid computation of the radiatively coupled flow problem. Radiative cooling experiments were conducted in a 6-inch annular arc accelerator shock tube (ANAA) for an initial pressure of 1 torr and shock speeds from 35 to 45 Km/sec. The results indicate that the lateral cooling is small compared with the axial cooling, and that better agreement is achieved between the data and the theoretical results by inclusion of the lateral temperature gradient.

Poon, P. T. Y.↗

Effect of tropospheric aerosols upon atmospheric infrared cooling rates

The effect of tropospheric aerosols on atmospheric infrared cooling rates is investigated by the use of recent models of infrared gaseous absorption. A radiative model of the atmosphere that incorporates dust as an absorber and scatterer of infrared radiation is constructed by employing the exponential kernel approximation to the radiative transfer equation. Scattering effects are represented in terms of a single scattering albedo and an asymmetry factor. The model is applied to estimate the effect of an aerosol layer made of spherical quartz particles on the infrared cooling rate. Calculations performed for a reference wavelength of 0.55 microns show an increased greenhouse effect, where the net upward flux at the surface is reduced by 10% owing to the strongly enhanced downward emission. There is a substantial increase in the cooling rate near the surface, but the mean cooling rate throughout the lower troposphere was only 10%.

Harshvardhan, MR.↗

Subsolidus convective cooling histories of terrestrial planets

The subsolidus convective cooling histories of terrestrial planets evolving from hot initial states are investigated quantitatively. A simple analytic model simulating average heat flux from a vigorously convecting mantle and incorporating a mantle viscosity proportional to mantle temperature and a lithosphere which thickens as the planet cools is employed. Heat flux from the convecting mantle is calculated on the basis of a power law relation between Nusselt number and Rayleigh number. The temperature distribution in the lithosphere is assumed to be linear throughout the cooling history of the planet. Cooling histories have been determined for the earth, Mars, Mercury and the moon and the mantle temperature decreases, mantle viscosity increases and decreases of heat flux to the surface and to the base of the lithosphere and of Nusselt and Rayleigh numbers are illustrated for each planet. It is found that primordial heat can contribute substantially to the present surface heat flux of a planet.

Schubert, G.↗

Olivine cooling speedometers

Several kinetic models of zoning in olivines are discussed at length. The effects on predicted cooling rates of various assumptions used in the analyses are evaluated. It is concluded that the models of Walker et al. (1977) and Taylor et al. (1977) both provide underestimates of the cooling rate required to preserve a given compositional profile, and that both models as well as the model of Taylor et al. (1978) can be used to provide order-of-magnitude estimates of cooling rates. A new model is described which considers diffusion in both solid and liquid during crystallization as well as diffusion in the solid after crystallization is complete. The model provides a description of the compositional gradients which develop during crystallization as well as after cooling at various rates. Applied to olivine crystals nucleated at 1272 C in a high-iron analogue to Lunar Composition 15555, the model predicts only slight compositional gradients - in accord with electron beam microprobe measurements on crystals grown isothermally at this temperature.

Onorato, P. I. K.↗

Full-scale wind tunnel study of nacelle shape on cooling drag

Tests were made in the NASA-Ames 40- by 80 Foot Wind Tunnel of a wing semispan with a nacelle (no propeller) from a typical, general aviation twin-engine aircraft. Measurements were made of the effect on drag of the cooling air flow through the nacelle. Internal and external nacelle pressures were measured. It was found that the cooling flow accounts for about 13% of the estimated airplane drag and about 42% of the cooling flow drag is associated with the internal flow. It was concluded that improvements could be made by relocating both the inlet and the outlet of the cooling air.

Corsiglia, V. R.↗

Radioisotope thermoelectric generator cooling in the Shuttle bay

The paper describes a Shuttle-integrated radioisotope thermoelectric generator (RTG) that consists primarily of a pump package and plumbing connected directly to the Shuttle payload heat exchanger. The RTG utilizes on-board water evaporative cooling capability, which is normally used for ascent, entry, and for supplementing the radiators. Attention is given to the RTG cooling concepts which include: (1) an active thermal cooling system (ATCS), where two Freon-21 loops operate simultaneously to transport heat from the Orbiter subsystem and payloads through liquid-to-liquid heat exchangers and pin-fin coldplates to four heat sinks, and (2) an atmosphere revitalization system (ARS) which provides for thermal, pressure, and contaminate control of the crew cabin and its equipment. The use of a payload heat exchanger to reduce weight, cost and complexity associated with an independent cooling system was investigated in detail.

Stimpson, L. D.↗

CO2 and CO electron vibrational cooling rates

Electron cooling rates for electron vibrational excitation of CO2 and CO and rotational excitation of CO are calculated. Results of the calculation are expressed as closed form analytic relations that are both convenient for numerical calculations and valid over a wide range of electron and neutral temperatures. It is found that the cooling rates and their temperature dependences differ significantly from other calculations. For CO2, these differences are related mainly to the assumptions about the approach to equilibrium and not to the actual cross-section choices. For electron temperatures below 1000 K and gas temperatures near 300 K (representative of conditions in the Venus atmosphere, where collisional cooling of the electrons dominates), the CO2 cooling rate is as much as an order of magnitude larger than previously considered in ionospheric models.

Porter, H. S.↗

Crystal/liquid partitioning in augite - Effects of cooling rate

The partitioning of major and minor elements between augite and melt was determined as a function of cooling rate for two high-titanium basalt compositions. The results of this study of lunar rock systems 10017 and 75055 were compared with the results of other kinetic studies of augite-liquid partitioning in other rock systems. It was found that the partitioning of major elements (i.e., Ca, Fe, Mg) is essentially rate independent and is insensitive to bulk rock composition and to the nature and order of appearance of coexisting phases for cooling rates of less than 100 C/hr. The partitioning behavior of minor elements (i.e., Al, Cr, Ti) for the same range of cooling rates is complex, being dependent on cooling rate and bulk rock composition. Consideration of these factors is important when augite chemistry and/or partitioning behavior are used in modeling certain magmatic processes or in estimating the thermal history of basaltic rocks.

Gamble, R. P.↗

Solar-Cooled Hotel in the Virgin Islands

Performance of solar cooling system is described in 21-page report. System provides cooling for public areas including ball rooms, restaurant, lounge, lobby and shops. Chilled water from solar-cooling system is also used to cool hot water from hotel's desalinization plant.

Harber, H.↗

Full-scale study of the cooling system aerodynamics of an operating piston engine installed in a light aircraft wing panel

Measurements of the drag and of the nacelle internal pressures on a wing and nacelle that housed a horizontally opposed piston engine were made in the 40- by 80-Foot Wind Tunnel at Ames Research Center. These tests are follow-ons to earlier tests made with the same wing and nacelle but in which the engine was replaced with an electric motor and an adjustable orifice plate. In the initial tests the orifice plate was used to control the rate of cooling-air flow through the nacelle and thereby to simulate a range of gasoline engine types. Good agreement was found between the results of those tests and of the test reported here. Also, the upper and lower plenum pressure and cooling-air flow rate were found to be related by conventional equations used to represent the flow through orifices. Tests were run with three cooling air inlet sizes over a free-stream velocity range from 50 to 150 knots, an angle of attack range from 0 deg to 10 deg, and a cowl-flap deflection range from 0 deg to 30 deg. The data were analyzed by computing a flow coefficient similar to that used in the analysis of orifices. It was found that all of the flow coefficient values fell within a band that varied linearly with inlet area. The linear mean line through this band provides an estimate of the relationship between cooling-air flow rate and upper plenum pressure over a wide range of test conditions.

Corsiglia, V. R.↗

The seasonal effect of nitric oxide cooling on the thermospheric U.V. heat budget

The effects of (1) the radiative cooling of vibrationally-excited NO at 5.3 microns and (2) radiation entrapment at 63 microns on the UV heating efficiency 'epsilon' are examined. It is noted that the previously used heating efficiency definition contradicts its logical application, and that the two processes mentioned should be included as cooling phenomena in the energy equations. Comparisons are made with previous work by including O and NO radiative cooling in the calculation of epsilon, which is found to vary from 45 to 60%, depending on how the two radiative cooling mechanisms are included in the calculation. It is also found that the shape of the heating efficiency altitude profile varies with season, while the peak value is nearly invariant.

Richards, P. G.↗

An accurate radiative heating and cooling algorithm for use in a dynamical model of the middle atmosphere

The circulation of the middle atmosphere of the earth (15-90 km) is driven by the unequal distribution of net radiative heating. Calculations have shown that local radiative heating is nearly balanced by radiative cooling throughout parts of the stratosphere and mesosphere. The 15 micrometer band of CO2 is the dominant component of the infrared cooling. The present investigation is concerned with an algorithm regarding the involved cooling process. The algorithm was designed for the semispectral primitive equation model of the stratosphere and mesosphere described by Holton and Wehrbein (1980). The model consists of 16 layers, each nominally 5 km thick, between the base of the stratosphere at 100 mb (approximately 16 km) and the base of the thermosphere (approximately 96 km). The considered algorithm provides a convenient means of incorporating cooling due to CO2 into dynamical models of the middle atmosphere.

Wehrbein, W. M.↗

Metering Baffle for Turbine-Blade Cooling

Mixing losses due to excessive film cooling reduced. Turbine blade or vane cooled by gas or liquid flowing through holes to exterior airfoil surface. Metering baffle inside airfoil controls flow to each row of cooling holes. Resulting surface-film flow keeps airfoil cool enough to operate in high-heat, high pressure turbines.

Moore, R.↗

Burner rig study of variables involved in hole plugging of air cooled turbine engine vanes

The effects of combustion gas composition, flame temperatures, and cooling air mass flow on the plugging of film cooling holes by a Ca-Fe-P-containing deposit were investigated. The testing was performed on film-cooled vanes exposed to the combustion gases of an atmospheric Mach 0.3 burner rig. The extent of plugging was determined by measurement of the open hole area at the conclusion of the tests as well as continuous monitoring of some of the tests using stop-action photography. In general, as the P content increased, plugging rates also increased. The plugging was reduced by increasing flame temperature and cooling air mass flow rates. At times up to approximately 2 hours little plugging was observed. This apparent incubation period was followed by rapid plugging, reaching in several hours a maximum closure whose value depended on the conditions of the test.

Deadmore, D. L.↗