Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “controllable loads”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Synergistic Effect of High Sulfur Loading Layered Cathode, Ceramic Separator and Gel Electrolyte

Lithium sulfur (Li-S) batteries are promising candidates for next-generation energy storage devices as they are capable of providing higher energy density and lower cost in comparison to the state of the art Li-ion batteries. To gain these characteristics, there are challenges such as polysulfide crossover, large volume changes during cycling, and deposition of insulating lithium sulfide that need to be alleviated. A popular approach to address these issues is to control the structure and properties of the carbon cathode in order to influence the transport of polysulfides, surface area for reaction, and lithium sulfide deposition. Ceramic separators on the other hand can drastically affect ion diffusion and overall battery performance. Safety concerns regarding the flammable liquid electrolyte can be reduced by deploying gel electrolyte. Towards this direction, we developed a layer-on-layer cathode structure with sulfur-impregnated activated carbon alternating with graphene layer, which was fabricated by Air-assisted electrospray. A much higher sulfur loading compared to slurry cast cathodes can be provided in this method. Combining the new cathode with gel electrolyte can offer higher safety of the battery and capacity retention. Ceramic separator would compensate the reduced ion conductivity of the gel electrolyte and the combination of these variables will be very promising in improvement of battery performance and safety.

25 ENERGY STORAGE↗

Cost Reduction of School Bus Fleet Electrification With Optimized Charging and Distributed Energy Resources: Preprint

Considerations for electrifying school buses are presented with an analysis of battery sizing to match bus driving requirements. The charging and vehicle-to-building dispatch of the electric school buses were optimized to evaluate the potential to reduce the impact of the bus charging on the school's electric utility bill. Distributed energy resources (DER) and flexible building loads were also considered with the school bus electrification to evaluate the further reduction in energy costs with enhanced system integration and optimized dispatch. The effect of degradation on the school bus batteries was analyzed to determine if the smart charging and vehicle-to-building battery operation decreases the life of the battery. The results show that there is an opportunity to mitigate the increase of electric utility bills with improved charging controls and bi-directionally operating the school bus batteries to reduce building demand charges. The battery degradation analysis using dispatch with optimized charging and discharging shows acceptable battery life.

24 POWER TRANSMISSION AND DISTRIBUTION↗

OC6 project Phase III: validation of the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure

Abstract. This paper provides a summary of the work done within Phase III of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project, under the International Energy Agency Wind Technology Collaboration Programme Task 30. This phase focused on validating the aerodynamic loading on a wind turbine rotor undergoing large motion caused by a floating support structure. Numerical models of the Technical University of Denmark 10 MW reference wind turbine were validated using measurement data from a 1:75 scale test performed during the UNsteady Aerodynamics for FLOating Wind (UNAFLOW) project and a follow-on experimental campaign, both performed at the Politecnico di Milano wind tunnel. Validation of the models was performed by comparing the loads for steady (fixed platform) and unsteady (harmonic motion of the platform) wind conditions. For the unsteady wind conditions, the platform was forced to oscillate in the surge and pitch directions under several frequencies and amplitudes. These oscillations result in a wind variation that impacts the rotor loads (e.g., thrust and torque). For the conditions studied in these tests, the system aerodynamic response was almost steady. Only a small hysteresis in airfoil performance undergoing angle of attack variations in attached flow was observed. During the experiments, the rotor speed and blade pitch angle were held constant. However, in real wind turbine operating conditions, the surge and pitch variations would result in rotor speed variations and/or blade pitch actuations, depending on the wind turbine controller region that the system is operating. Additional simulations with these control parameters were conducted to verify the fidelity of different models. Participant results showed, in general, a good agreement with the experimental measurements and the need to account for dynamic inflow when there are changes in the flow conditions due to the rotor speed variations or blade pitch actuations in response to surge and pitch motion. Numerical models not accounting for dynamic inflow effects predicted rotor loads that were 9 % lower in amplitude during rotor speed variations and 18 % higher in amplitude during blade pitch actuations.

17 WIND ENERGY↗

Control-oriented core-SOL-divertor model to address integrated burn and divertor control challenges in ITER

The real-time regulation of a burning plasma’s temperature and density, or burn control, will be necessary to produce high fusion power in future tokamaks like ITER. This is made more challenging due to the plasma’s nonlinear characteristics and the interdependence between the core-plasma and edge-plasma regions. For example, a raising plasma temperature leads to increasing reactivity and therefore to more alpha-particle heating, which further increases temperature. Furthermore, a raise of the fusion power increases the heat flow through the scrape-off-layer (SOL), which can compromise the integrity of the divertor without proper safeguards. For control design, a model-based approach is attractive because it can directly incorporate the nonlinear, coupled, burning-plasma dynamics into the design. To facilitate this design approach, a control-oriented core-SOL-divertor (CSD) model is presented in this work. In this CSD model, a core-plasma model captures the nonlinear dynamics of the core’s density and temperature, and a SOL-divertor model defines the plasma conditions at the separatrix and divertor including the heat load on the target plates. The core-plasma and SOL-divertor models are coupled through the exchange of various variables. In particular, the SOL-divertor model yields the separatrix temperature and the influx of recycled particles into the core-plasma. Further, these variables influence the power and particle balances captured by the core-plasma model. In return, the core-plasma model determines the intensity of the heat and particles fluxes across the separatrix, and this outflow strongly impacts the SOL-divertor model. Therefore, the power and density of the core-plasma, which can be readily modulated through external heating systems and pellet injection, can be viewed as control knobs for the SOL-divertor region in addition to the gas puffing. In simulations of the CSD model, it is demonstrated how external actuation can be utilized to meet burn control and divertor control objectives simultaneously.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of Online Cross-Section Generation Capability with Depletion and Transient Solvers in Griffin

Griffin is a Multiphysics Object-Oriented Simulation Environment (MOOSE)-based reactor multiphysics analysis application jointly developed by Argonne and Idaho National Laboratories under the DOENE Nuclear Energy Advanced Modeling and Simulation (NEAMS) program. In FY25, an online crosssection generation capability based on the Self-Shielding Application Programming Interface (SSAPI) was demonstrated for TRISO-fueled reactor problems under steady-state conditions. This fiscal year, that capability was extended to support depletion and transient multiphysics calculations, enabling high-fidelity analyses that generate self-shielded cross sections on the fly from the actual evolving composition and temperature states rather than from pre-tabulated libraries. For depletion, a two-way coupling was established in which SSAPI computes compact-averaged self-shielded cross sections that the depletion solver then uses to advance the Bateman equations, with the updated compositions returned to SSAPI at each step; the depletion module was refactored to support both library-based and SSAPI-based cross sections, and additional logic was added to track daughter isotopes and to exclude minor isotopes for efficiency. For transient analysis, the SSAPI multigroup library was extended with the kinetics data required for time-dependent calculations, the Improved Quasi-Static (IQS) scheme was coupled with SSAPI, and several supporting capabilities were implemented, including a self-shielding treatment that lets control rods and drums move within a self-shielded model, which had previously been impossible and had ruled out rod- and drum-movement transients with on-the-fly cross sections altogether, a new mixing scheme for delayed-neutron precursor decay constants, a checkpoint-based restart workflow, and performance improvements such as pointwise cross-section interpolation and the bypassing of unnecessary Dancoff factor calculations. The implemented capabilities were verified against Serpent Monte Carlo solutions. For depletion, a prismatic pin-cell problem based on a Next Generation Nuclear Plant (NGNP) Very High Temperature Reactor benchmark showed excellent agreement, with eigenvalue differences within 200 pcm over the entire burnup range (up to 140 MWD/kgU) and fission-product and actinide inventories agreeing to within 0.8% and 2.5%, respectively; a heat-pipe microreactor assembly problem with a much higher fuel loading confirmed the same behavior and quantified the bias introduced when the multigroup equivalence effect is neglected. For transient analysis, a pin-cell problem with a step reactivity insertion and temperature feedback reproduced the analytically expected asymptotic power and showed close agreement between the direct and IQS solutions, and a two-dimensional microreactor core problem with control-drum rotation exercised the new moving-drum self-shielding treatment and demonstrated successful coupling of the online crosssection generation with both the direct and IQS transient methods. The capability was further exercised on a full-core pebble-bed problem, in which Griffin was coupled with the System Analysis Module (SAM) to simulate load-following operation of the gPBR with the Doppler feedback resolved at the TRISO fuel kernel temperature. These developments in Griffin provide a convenient, high-fidelity approach to cross-section generation for advanced thermal reactors with geometrically complex and highly heterogeneous configurations, including TRISO-fueled prismatic and pebble-bed systems, and support steady-state, depletion, and transient multiphysics calculations. They also enable self-shielded cross sections to be evaluated directly at the actual coupled state of the system, thereby establishing a foundation for high-fidelity, fully coupled multiphysics analysis of advanced reactors

Park, H.↗

Experimental Tests of Lateral Bedload Transport Induced by a Yawed Submerged Vane Array in Open-Channel Flows

This work proposes the use of an array of yawed porous vanes to control the lateral bedload transport by locally steering bedform migration and maximize the amount of sediments redirected toward a potential sediment extraction system or bypass channel. A laboratory experiment was conducted in a quasifield-scale channel with an array of permeable vanes installed on one side, in live-bed conditions under bedload dominant regime, i.e., negligible suspended load. A baseline experiment without vanes was also performed for comparison. The evolution of migrating bedforms of different scales was tracked in space and time using a high-resolution, state-of-the-art laser scanning device. The bedload transport rate in the streamwise direction was first calculated using bedforms’ geometry and migration velocity, and then spatially distributed over the entire monitored area using a new Eulerian-averaged grid-mapping method. This allowed us to introduce a new methodology to estimate the lateral bedload transport using control volume theory and applying mass conservation. Quantitative assessments of lateral bedload transport along the channel yield consistent results, suggesting that the vanes effectively move sediments laterally as intended. Under the investigated setup, the maximum lateral sediment transport rate ranges from 9% to 18% of the whole domain-averaged streamwise transport rate. The developed methodology also allowed to identify the location where sediment capture could be maximized for the given vane spatial distribution.

42 ENGINEERING↗

Model-Free Dynamic Voltage Control of Distributed Energy Resource (DER)-Based Microgrids

In this paper, we present a new control technique for sustaining dynamic voltage stability by effective reactive power control and coordination of distributed energy resources (DERs) in microgrids. The proposed control technique is based on model-free control (MFC), which has shown successful operation and improved performance in different domains and applications. This paper presents its first use in the voltage stability of a microgrid setting employing multiple synchronous generator (SG)-based and power electronic (PE)-based DERs. MFC is a computationally efficient, data-driven control technique that does not require modelling of the different components and disturbances in the power system. It is utilized as an online controller to achieve the dynamic voltage stability of a microgrid system under different disturbances and fault conditions. A 21-bus microgrid system fed by multiple DERs is considered as a case study and the overall dynamic voltage stability is investigated using time-domain dynamic simulations. Numerical results show that the proposed MFC provides improvements on the dynamic load bus voltage profiles and requires less computational time as compared to the traditional enhanced microgrid voltage stabilizer (EMGVS) scheme. Due to its simplicity and low computational requirement, MFC can be easily implemented in resource-constrained computing devices such as smart inverters.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stackelberg Game Based on Supervised Charging Method and Pricing Strategy of Charging Service Providers

The charging of large-scale electric vehicles (EVs) brings about a large new load to the electricity network, while it is also a demand response resource. Smart charging equipment and patterns of charging service will be one of the research focuses at the next stage. Smart charging equipment schedules EV's charging on the basis of electricity price, and this method enables users to hold the right of controlling their own EV's charging procedure. Thus, there exists a Stackelberg game between charging service providers, who set the price, and independent EVs. The marginal charging price, which reflects properties of individual EV, and the pricing strategy of charging service providers can be derived through solving this game problem. A price based charging strategy is proposed, which is suitable for the dynamic electricity price mechanism because of its light communication burden. In a simulation of a charging service provider covering 200 smart devices, this real-time supervised charging strategy shows its advantages of curbing users' payment and guiding the charging load effectively.

33 ADVANCED PROPULSION SYSTEMS↗

Lithium–Sulfur Batteries Enabled by Fluorine-Free Electrolytes with a Compressed Solvation Structure

In this paper, a fluorine-free aromatic cosolvent strategy is presented to regulate electrolyte solvation chemistry in Li-S batteries with sulfurized polyacrylonitrile (SPAN) cathodes. Assisted by the Uni-ELF AI tool and experimental validation, toluene is identified as an optimal weakly solvating cosolvent. Its incorporation compresses the Li⁺ solvation sheath and induces an anion-dominated solvation structure, thereby enhancing interfacial ion transport and sulfur redox kinetics through controlled π-π interactions with polysulfides. Consequently, Li || Li symmetric cells exhibit stable cycling for over 1,000 cycles at a current density of 1 mA cm⁻². Meanwhile, Li-S cells employing high-loading SPAN cathodes retain more than 75% of their initial capacity after 250 cycles at -10 °C. Additionally, a practical pouch cell with high SPAN loading and a low electrolyte-to-SPAN ratio of 3 µL mg⁻¹ delivers an initial capacity of around 600 mAh gSPAN⁻¹, underscoring the potential of fluorine-free electrolytes for practical metal-sulfur batteries.

25 ENERGY STORAGE↗

General Applications for Hamilton Vantage (GenApps for Vantage) v0.6.1

General applications for Hamilton Vantage is a flexible liquid handling method used to automate the most widely applicable types of automated liquid transfers. General applications can also be used as a tool to onboard new fully-automated workflows by breaking them down step by step into single transfers. The goal of General Applications is to make using the Hamilton Vantage liquid handler as easy & practical as using a handheld pipette for the end user. The software supports plate-to-plate transfers for a variety of method types including: Stamp: One-to-One, Stamp: One-To-Many, Split, Combine, Hitpick, and Qtray plating. General Applications eliminates the need for automation engineers to customize individual methods for each new workflow that gets onboarded. Steps can be customized within GenApps according to the needs of the researcher. The software utilizes a GUI to prompt the users to input variables – Allowing for flexible control over plate types, transfer volumes, number of replicates, tip types, liquid classes, mixing steps, aspiration/dispense heights and more. General Applications also generates a deck image and setup instructions to guide the researcher on how to load the deck and start the instrument.

Yoder, Sam↗

Cyber-Physical Dynamic System (CPDS) Modeling for Frequency Regulation and AGC Services of Distributed Energy Resources

The substantial integration of renewable energy brings significant challenges to balance the system in real time because of the variability and intermittency of renewable power. For the reliable system operation, the frequency regulation service is used to stabilize the system frequency through automatically balancing the system generation and load. On one hand, with the substantially increasing deployment of renewable energy in electricity system, the requirement of frequency regulation (FR) services increases significantly. On the other hand, the current main resource of FR services, the controllable conventional generation, is continuously decreasing in the system generation mix. This means that in the future high renewable penetration power system, additional and alternative reliable FR services providers such as distributed energy storage (DES) resources should be explored. Although the capability of utility-scale energy storage to provide FR services has been demonstrated, the integrated control and dynamic modeling of distributed energy resource (DER) providing frequency regulation grid services has been rarely explored. There are several challenges to adopt DERs to provide reliable grid services as illustrated in FERC 755. First, the distributed installation of DES requires a comprehensive cyber-physical dynamic system (CPDS) modeling to fully consider the impacts of the communication latency variability on its real time FR provision capability. Unlike the conventional generators, there are two-layer communication between DERs and system operators which increase the communication delay. Second, unlike the conventional generators whose dynamic models have been comprehensively studied, the difference among individual DER components' power-dynamic characteristic brings challenges in the accurate dynamic AGC modeling of its power-frequency relationship. Third, the temporal dependent state of charge uncertainty of DERs challenges DERs' power and frequency regulation capacities scheduling in the look-ahead generation scheduling. Therefore, the aggregator should optimize the frequency regulation provision from individual DER in real time. To overcome these challenges, this project proposes a cyber-physical dynamic system (CPDS) model to handle the uncertainty of DERs two-layer communication latency and power dynamics. The variability of DERs' communication delay and dynamic constraints will be comprehensively modeled. The DERs' AGC model with communication delay is designed to validate DESs' frequency regulation services. Like current performance-based frequency regulation evaluation, the delivery of DERs' frequency regulation will be assessed through post-analysis of the actual AGC response with respect to the AGC control signal from system operators. Consequently, the reliability improvement with DERs providing reliable frequency regulation services can be evaluated from a comprehensive perspective considering all the dynamics of communication and power.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Using Best Basis Inventory Data to Direct Strategies for Real-Time Monitoring of Hanford High Level Waste

The proposed Direct Feed High Level Waste (DFHLW) approach for processing high-level tank waste at Hanford is intended to reduce processing time by bypassing the Pretreatment Facility and transferring waste directly from the tank farm to the WTP HLW vitrification facility. This processing strategy could reduce or eliminate the washing and leaching steps that would have occurred in the Pretreatment facility. Operation of the vitrification facility is subject to chemical and radiological limits protecting safety (e.g. Waste Acceptance Criteria, or WACs) and process quality (e.g. Process Control Limits, or PCLs). Without washing and leaching, there is a greater risk of exceeding the WACs and PCLs. Hanford process engineers have devised blending strategies based on known chemical and radiological composition, volumes, and solids loadings of individual layers within each waste tank. These blending campaigns succeed in predicting a processing strategy that does not exceed the WACs and PCLs. However, the calculations do not ascribe uncertainties to the tank analysis data, quantities of material taken from the tanks to make the blend, or potential for mixing of layers within tanks. In order to confirm that a process strategy is working, it would be advantageous to have inline or at-line analytical instrumentation installed in the processing facilities that deliver measurement results in real time.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Guarded Hot Cylinder Apparatus for Characterization of Thermal Insulation Systems and Materials at Liquid Hydrogen Temperatures

As interest in liquid hydrogen (LH2) continues to grow within the energy and mobility sectors, so does the demand for testing capabilities at deep cryogenics temperatures. However, cost-, complexity-, and safety-related challenges associated with handling LH2 effectively limit the landscape of possible options. As an alternative, LH2 temperatures can be accessed via a helium-based cryogenic refrigerator, or “cryocooler”. Recently, NASA and its partners CB&I and Shell began the development of a cryocooler-based calorimeter to characterize the thermal performance of insulations and other materials down to 20 K. Deemed the Guarded Hot Cylinder (GHC), the apparatus utilizes a small vacuum chamber in conjunction with a GM cryocooler and trim heater to control the cold boundary temperature. A sealed, cylindrical copper cup bolts to the cryocooler and houses the material specimen, with an internal, cylindrical test heater assembly to maintain the warm boundary. The steady-state heat load, traveling radially through the specimen, is measured via the electrical input power to the test heater and then used to evaluate the material’s absolute thermal performance. Initial checkout and validation of the GHC using a common bulk-fill insulation material showed close agreement with published data from standardized LN2 boiloff calorimetry testing. The instrument is now considered a lab standard, with the goal of incorporating it into the ASTM C1774 standard in the future, and it is in continuous use, examining insulation materials for next-generation LH2 applications.

Swanger, Adam (ORCID:000000021487592X)↗

Smart Building Technology Training Modules for Academic and Professional Education

Smart building technologies are a new suite of resources that improve building energy efficiency and resilience, reduce carbon emissions, and provide load flexibility to the grid. However, in both college curricula and building professionals’ continuing education, there is a lack of systematic instruction on smart building technologies–topics that include smart building concepts, key components, smart building controls, “Internet of Things” (IoT) devices, and how to integrate multiple energy systems including distributed energy resources (DER). This major gap in smart building education prevents stakeholders from understanding and adopting smart building technologies in building design and operations. Slipstream leads a DOE-funded project developing a semester-long smart building curriculum for college students and adapting the contents into 16 training videos for building professionals and the general public. The education and training cover the drivers and benefits of smart building technologies, key building energy systems, the latest sensor technologies and IoT devices, and focus on topics related to smart building controls (i.e., energy management information systems, smart building control platforms, cybersecurity, grid-interactive-efficient buildings (GEBs), smart building control methods, and occupant-centric control. This paper describes the project approach, provides outlines of the training materials, and identifies lessons learned in creating the content. We also suggest ways to scale the instruction of smart building concepts to empower the workforce to accelerate the adoption of smart building technologies in the real world.

99 GENERAL AND MISCELLANEOUS↗

Best Practices for Shielding Analyses of Activated Metals and Spent Resins from Reactor Operation

This report investigated best practices for performing shielding evaluations of Type B waste packages, as defined in 10 CFR Part 71 regulations on packaging and transportation of radioactive material, or packages for which the contents are not defined before loading and may include a broad range of nuclides, geometries, and non-fuel materials. The following non-fuel waste streams were analyzed: Activated metals from decommissioned commercial power reactors, including Type 304 stainless steel, reactor vessel steel, and Inconel, Control blades from boiling water reactors, Neutron-activated corrosion products on surfaces of activated metals, and Spent resins from power plant operations. Measured elemental compositions, including major constituents and impurities, for steel and Inconel samples from commercial power reactors were used in activation calculations to determine radionuclide inventories in activated metals. For a simplified cask model, 60 Co contribution to the total external package dose rate at 30 days after shutdown varied from approximately 60% to 95%, depending on the activated metal, initial cobalt impurity concentration in the metal, and the thickness of the overpack gamma shield. Its maximum contribution to the total external package dose rate of approximately 100% was reached within the time interval of 2 to 5 years after shutdown and was maintained for up to 45 to 60 years after shutdown, depending on material, initial cobalt impurity concentration, and shield thickness. Thereafter, the 60 Co contribution to external package dose rate decreased with increasing decay time. Cobalt-60 is primarily produced by neutron reactions with the cobalt impurity in steel and Inconel. Other important radionuclides in activated metals contributing to package external dose rate are radionuclides with relatively short decay times, including 51 Cr, 59 Fe, 58 Co, and 54 Mn. These radionuclides may be represented as an equivalent 60 Co activity/source because 60 Co gamma ray emissions are bounding in terms of source strength and energy to other important radionuclides identified in the analyzed activated metals. Approaches for modeling the neutron-activated corrosion products that may be attached to activated reactor components were analyzed in this report. It was demonstrated that a surface source is more conservative than a uniform volumetric source for the treatment of neutron-activated corrosion products with respect to external package dose rates. An analysis of the maximum radionuclide loadings reported on spent resins identified the radionuclides 137 Cs, 60 Co, 134 Cs, 65 Zn, and 58 Co as the primary contributors to external package dose rate. For a resin cooled for 3.08 years, the external package dose rate was entirely produced by the reported 137 Cs and 60 Co inventory. The neutron sources from actinides found on spent resins or activated metals produced negligible dose rates and may be ignored in dose rate analyses. Effects of idealized waste material, source geometry, and spatial material/source distributions on external package dose rates were determined based on dose rate results for a simplified cask model under normal conditions of transport. Type 304 stainless steel, zirconium, and aluminum with adjusted mass densities based on a maximum content weight were analyzed for material modeling effects on external package dose rate. These materials produced identical external package dose rates within the statistical uncertainties of the dose rate estimates. Among four different source geometry configurations with homogeneous material of different mass densities, uniform volumetric source distribution, and the same source strength, the geometry configuration with lowest mass density (i.e., minimum self-shielding effect among the four cases) was most conservative. Spatial source distributions that better represent localized peak 60 Co activity values were more conservative than a uniform volumetric source distribution, assuming the same weight and total source strength per package. The increase in external dose rate caused by localized source peaks can be as much as the ratio between source peak activity density to average activity density, depending on the location of the activated metal with peak activity density. Therefore, the shielding analysis may be simplified if localized peak activities and the average activity per package can be measured/determined and documented at the time of cask loading. For simplicity, external package dose rates may be determined based on average source activity and a uniform volumetric source distribution. The dose rate results from that calculation model multiplied by the ratio of peak activity density to average activity density will produce maximum dose rate values for conservative estimates.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Shaping of Grid Response of Multi-Machine Multi-Inverter Systems Through Grid-Forming IBRs

We consider the problem of controlling the frequency response of weakly-coupled multi-machine multi-inverter low-inertia power systems via grid-forming inverter-based resources (IBRs). In contrast to existing methods, our approach relies on dividing the larger system into multiple strongly-coupled subsystems, without ignoring either the underlying network or approximating the subsystem response as an aggregate harmonic mean model. Rather, through a structured clustering and recursive dynamic shaping approach, the frequency response of the overall system to load perturbations is shaped appropriately. We demonstrate the proposed approach for a three-node triangular configuration and a small-scale radial network. Furthermore, previous synchronization analysis for heterogeneous systems requires the machines to satisfy certain proportionality property. In our approach, the effective transfer functions for each cluster can be tuned by the IBRs to satisfy such property, enabling us to apply the shaping control to systems with a wider range of heterogeneous machines.

frequency-shaping control↗

Efficient excitation and control of integrated photonic circuits with virtual critical coupling

Critical coupling in integrated photonic devices enables the efficient transfer of energy from a waveguide to a resonator, a key operation for many applications. This condition is achieved when the resonator loss rate is equal to the coupling rate to the bus waveguide. Carefully matching these quantities is challenging in practice, due to variations in the resonator properties resulting from fabrication and external conditions. Here, we demonstrate that efficient energy transfer to a non-critically coupled resonator can be achieved by tailoring the excitation signal in time. We rely on excitations oscillating at complex frequencies to load an otherwise overcoupled resonator, demonstrating that a virtual critical coupling condition is achieved if the imaginary part of the complex frequency equals the mismatch between loss and coupling rate. We probe a microring resonator with tailored pulses and observe a minimum intensity transmission T = 0.11 in contrast to a continuous-wave transmission T = 0.58, corresponding to 8 times enhancement of intracavity intensity. Our technique opens opportunities for enhancing and controlling on-demand light-matter interactions for linear and nonlinear photonic platforms.

42 ENGINEERING↗