Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “collider”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Front-end electronic readout system for the Belle II imaging Time-Of-Propagation detector

The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB ee collider. The purpose of the detector is to identify the type of charged hadrons produced in ee collisions, and requires a single photon timing resolution below 100 picoseconds. A novel front-end electronic system was designed, built, and integrated to acquire data from the 8192 microchannel plate photomultiplier tube channels in the detector. Waveform sampling of these analog signals is done by switched-capacitor array application-specific integrated circuits. The processes of triggering, digitization of windows of interest, readout, and data transfer to the Belle II data acquisition system are managed by Xilinx Zynq-7000 programmable system on a chip devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A new Transition Radiation detector based on GEM technology

Transition Radiation Detectors (TRD) have the potential feature of separating particles by their gamma factor. Classical TRDs are based on Multi-Wire Proportional Chambers (MWPC) or straw tubes, using a Xenon based gas mixture to efficiently absorb transition radiation photons. These detectors operate well in experiments with relatively low particle multiplicity. The performance of MWPC-TRD in experiments with luminosity of order 10 34 cm 2 s –1 and above, is significantly deteriorated due to the high particle multiplicity and channel occupancy. Replacing MWPC or straw tubes with a high granularity Micro Pattern Gas Detectors (MPGD) like Gas Electron Multipliers (GEMs), could improve the performance of the TRD. In addition, GEM technology allows one to combine a tracker with TRD identification (GEM-TRD/T). This report presents a new TRD development based on GEM technology for the future Electron Ion Collider (EIC). The first beam test was performed at Jefferson Lab (Hall-D) using 3–6 GeV electrons. A GEM-TRD/T module has been exposed to electrons with and without a fiber radiator. First results of test beam measurements and comparison with Geant4 Monte Carlo are introduced here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of Large Area Picosecond Photo-Detectors (LAPPD TM )

In this study, we report on performance results achieved for recently produced LAPPDs - largest commercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to 1 0 7 , low dark noise rates (~100 Hz/cm 2 at a gain of 6 ∙ 1 0 6 ), single photoelectron (PE) timing resolution of ~50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE (Back et al., 2017), WATCHMAN (Askins et al., 2015), DUNE (Capozzi et al., 2018), particle collider experiments (e.g. EIC (Accardi et al., 2016), neutrinoless double-beta decay experiments (e.g. THEIA (Fischer et al., 2018)), medical and nuclear non-proliferation applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a large active area beam telescope based on the SiD microstrip sensor

A beam telescope as one of the most important and often requested test beam equipment provides particle tracking to test beam users. At the DESY II test beam facility, a new beam telescope called Lycorisbased on a microstrip sensor has been designed to address the user demands for momentum measurement in a 1 T solenoid magnet or large area tracking with limited space (3.5 cm between the potential user device and the magnet inner wall). Lycorisis designed to provide a high-precision resolution of at least ~10 µm along the bending direction, and a large active area of 10x10 cm 2 to cover at least 90% of the beam particles at energies of 1-6 GeV. The microstrip sensor was originally designed for the Silicon Detector (SiD) at the International Linear Collider (ILC), which adopted a hybrid-less design, i.e. a second metallization layer is used to route signals from strips to the bump-bonded ASIC, and from the ASIC to a wire-bond pad to the outside. This hybrid-less arrangement eliminates the need for a complex hybrid design, and its functioning is first-time tested in this project. The performance of the sensor modules was firstly tested in the lab then at the DESY II test beam facility in August/September 2018, and the results will be presented here. In addition, a summary will be given at the end with an overview of the ongoing test beam campaign of the Lycorisprototype in February 2019.

47 OTHER INSTRUMENTATION↗

Hadron blind Cherenkov counters

A Hadron Blind Detector, or HBD, is a novel form of Cherenkov counter that is designed to provide high efficiency for detecting highly relativistic electrons while being essentially blind to most hadrons. Herein, we present some of the most prominent realizations of the HBD concept in real experiments. We describe the first implementation of an HBD that was made in the CERES experiment at CERN using a spectrometer based on a doublet of hadron blind RICH detectors for the measurement of low-mass electron pairs in pA and AA collisions at the SPS. We next present a detailed account of a more extensive realization of the HBD that was made in the PHENIX experiment for the measurement of low-mass electron pairs in central heavy-ion collisions at RHIC, followed by a description of a very similar detector that is currently under construction at J-PARC for the measurement of vector mesons through their e + e – decay in pA collisions. We conclude with a brief discussion of possible evolutions of the HBD concept as well as possible developments and uses of HBDs in experiments at the future Electron Ion Collider.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Performance of prototype GE1/1 chambers for the CMS muon spectrometer upgrade

The high-luminosity phase of the Large Hadron Collider (HL-LHC) will result in ten times higher particle background than measured during the first phase of LHC operation. In order to fully exploit the highly-demanding operating conditions during HL-LHC, the Compact Muon Solenoid (CMS) Collaboration will use Gas Electron Multiplier (GEM) detector technology. The technology will be integrated into the innermost region of the forward muon spectrometer of CMS as an additional muon station called GE1/1. The primary purpose of this auxiliary station is to help in muon reconstruction and to control level-1 muon trigger rates in the pseudo-rapidity region 1.6 ≤ |η| ≤ 2.2. The new station will contain trapezoidal-shaped GEM detectors called GE1/1 chambers. The design of these chambers is finalized, and the installation is in progress during the Long Shutdown phase two (LS-2) that started in 2019. Several full-size prototypes were built and operated successfully in various test beams at CERN. Here, we describe performance measurements such as gain, efficiency, and time resolution of these prototype chambers, developed after years of R&D, and summarize their behavior in different gas compositions as a function of the applied voltage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A state of the art Lambertson septum magnet of the RHIC beam injection system

The beam injection system of the Relativistic Heavy Ion Collider (RHIC) is the last section of the beam transfer line which transports the beam from the Alternating Gradient Synchrotron (AGS) to RHIC and comes under the acronym AtR (AGS to RHIC). The Lambertson septum magnet is one of the magnetic elements of the RHIC injection system. This paper presents results from the 2D and 3D electromagnetic design of the RHIC Lambertson septum magnet which has unique design features to minimize the magnetic field at the circulated beam region including the fringe field regions at the entrance and exit of the magnet.

43 PARTICLE ACCELERATORS↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Effects of trapped charge on the signal formation and detection efficiency for subsequent pulses in irradiated silicon sensors

Envisaged high energy physics experiments like the Future Circular Collider require unprecedented radiation hardness of the detectors, as well as short readout time due to high luminosity and occupancy. Silicon has proven to be extremely radiation hard. Sufficient signals can be recorded even at fluences close to 1 ∙ 1 0 16 n e q / cm 2 . Here, the signal formation was studied in silicon strip sensors, irradiated and annealed until the phenomenon of charge multiplication occurred. ATLAS12EC R0 mini sensors were tested by means of edge TCT measurements at temperatures around –20 °C. It was observed that the detection of subsequent signals separated up to several microseconds is altered by the charge trapped during the preceding pulses. The effects of trapped charge on the electrical configuration of a sensor are well known as a polarization or pumping effect in larger band-gap materials like diamond, but is often neglected for silicon at this relatively high temperature. The investigation of the effect created by trapped charges in silicon sensors using subsequent pulses allows to gain information on important parameters such as de-trapping times. Furthermore, it shows a severe impact on the sensor performance in a pile-up scenario. The irradiation fluence and hence the effective doping concentration, the temperature and the amount of initially created charge have a large impact on this phenomenon. The measurements presented help to characterize this phenomenon; particular attention was paid to the application point of view.

47 OTHER INSTRUMENTATION↗

Study of CMOS strip sensor for future silicon tracker

Monolithic silicon sensors developed with High-Voltage CMOS (HV-CMOS) processes have become highly attractive for charged particle tracking. Compared with the standard CMOS sensors, HV-CMOS sensors can provide larger and deeper depletion regions that lead to larger signals and faster charge collection. They can provide high position resolution, low material budget, high radiation hardness and low cost that are desirable for high performance tracking in harsh collision environment. Various studies have been conducted to explore the technology feasibility for the large-area tracking systems at future collider experiments. CHESS (CMOS HV/HR Evaluation for Strip Sensor) sensor series have been developed as an alternative solution to the conventional silicon micro-strip detectors for the ATLAS inner tracker upgrade. The first prototype (named CHESS1) was to evaluate the diode geometry and the in-pixel analog electronics. Obtained test results were used to optimize the second prototype (named CHESS2). CHESS2 was implemented with a full digital readout architecture and realized as a full reticle sized monolithic sensor. Here, the basic characteristics of the CHESS2 prototype sensors and their performance in response to different input signals are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and evaluation of large area strip sensor prototypes for the ATLAS Inner Tracker detector

The ATLAS community is facing the last stages prior to the production of the upgraded silicon strip Inner Tracker for the High-Luminosity Large Hadron Collider. An extensive Market Survey was carried out in order to evaluate the capability of different foundries to fabricate large area silicon strip sensors, satisfying the ATLAS specifications. The semiconductor manufacturing company, Infineon Technologies AG, was one of the two foundries, along with Hamamatsu Photonics K.K., that reached the last stage of the evaluation for the production of the new devices. The full prototype wafer layout for the participation of Infineon, called ATLAS17LS-IFX, was designed using a newly developed Python-based Automatic Layout Generation Tool, able to rapidly design sensors with different characteristics and dimensions based on a few geometrical and technological input parameters. Here we present the layout design process and the results obtained from the evaluation of the new Infineon large area sensors before and after proton and neutron irradiations, up to fluences expected in the inner layers of the future ATLAS detector.

79 ASTRONOMY AND ASTROPHYSICS↗

Patterned anodes with sub-millimeter spatial resolution for large-area MCP-based photodetector systems

Micro-channel-plate-based photo-detectors are unique in being capable of covering very large areas such as those required in elementary particle and nuclear physics, while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, and time resolutions of 30 psec–50 psec for single photons. In such systems the electronic channel count is a major cost driver. Incorporating a capacitively-coupled anode allows the use of external pickup electrodes with patterns of individual channels optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be economically implemented as a printed circuit card with a 2-dimensional array of pads for high-occupancy/high-rate applications such as in particle colliders and medical imaging, or a 1-dimensional array of strips for a lower channel count in low-occupancy/low-rate applications such as large neutrino detectors. In this paper we present pad patterns that enhance signal-sharing between pads to lower the channel count per unit area in large-area systems by factors up to 4, while maintaining spatial resolutions of approximately 100 to 200 μ m for charged particles and 400 to 1000 μ m for single photons. Patterns that use multiple signal layers in the signal-pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ka-band linearizer for the Ultra-Compact X-ray free-electron laser at UCLA

There is a strong demand for accelerating structures able to achieve higher gradients and more compact dimensions for the next generation of linear accelerators for research, industrial and medical applications. Notably innovative technologies will permit compact and affordable advanced accelerators as the linear collider and X-ray free-electron lasers (XFELs) with accelerating gradients over twice the value achieved with current technologies. In particular XFELs are able to produce coherent X-ray pulses with peak brightness 10 orders of magnitude greater than preceding approaches, which has revolutionized numerous research fields through imaging of the nanoscopic world at the time and length scale of atom-based systems, that is of femtosecond and Angstrom. There is a strong interest for combining these two fields, to form a proper tool with the goal of producing a very compact XFEL in order to investigate multi-disciplinary topics in chemistry, biology, materials science, medicine and physics. In the framework of the Ultra-Compact XFEL project under study at the University of California, Los Angeles, a high gradient radio-frequency accelerating structure for the longitudinal phase-space linearization with an integrated voltage of at least 15 MV working on 6th harmonic of the main Linac frequency is required. We here present the electromagnetic design of a cryogenic normal-conducting 8 cm long Ka-band standing-wave linearizer working on π mode with a target accelerating gradient beyond 100 MV/m. The studies have been performed analytically and numerically to investigate the beam dynamics and electromagnetic issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined analysis of HPK 3.1 LGADs using a proton beam, beta source, and probe station towards establishing high volume quality control

The upgrades of the CMS and ATLAS experiments for the high luminosity phase of the Large Hadron Collider will employ precision timing detectors based on Low Gain Avalanche Detectors (LGADs). We present a suite of results combining measurements from the Fermilab Test Beam Facility, a beta source telescope, and a probe station, allowing full characterization of the HPK type 3.1 production of LGAD prototypes developed for these detectors. We demonstrate that the LGAD response to high energy test beam particles is accurately reproduced with a beta source. Finally, we further establish that probe station measurements of the gain implant accurately predict the particle response and operating parameters of each sensor, and conclude that the uniformity of the gain implant in this production is sufficient to produce full-sized sensors for the ATLAS and CMS timing detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First 3D vector tracking of helium recoils for fast neutron measurements at Super$\mathrm{KEKB}$

Here we present results from the first deployment of novel, high definition, compact gas Time Projection Chambers (TPCs) with pixel chip readout as part of the BEAST II beam background measurement project at SuperKEKB. The TPCs provide detailed 3D imaging of ionization from neutron-induced nuclear recoils in a helium and carbon dioxide target gas mixture at standard temperature and pressure. We present the TPC performance and the neutron backgrounds observed during the initial stage of collider commissioning. We find excellent electron background rejection, leading to background-free nuclear recoil measurements above 50 keV ee , despite the extreme high-background environment. We measure an angular resolution better than 20° for recoil tracks longer than 1.7 mm, corresponding to an average ionization energy of approximately 100 keV ee . We also obtain the full 3D vector direction of helium recoils by utilizing charge profile measurements along the recoil axis, with a correct head/tail assignment efficiency of approximately 80%. With this performance, we present comparisons between measured and simulated event rates, recoil energy spectra, and directional distributions originating from beam–gas and Touschek beam losses at SuperKEKB. We utilize head/tail recognition to distinguish neutron components traveling with positive radial velocity in the Belle II coordinate system from those traveling in the opposite direction. Finally, we present a novel method of discriminating beam–gas interactions from Touschek beam losses that can eliminate the need for dedicated accelerator runs for background measurements. This method is still statistics-limited. However, future studies should be able to verify this method, which in turn could lead to neutron background analysis runs symbiotic with normal Belle II operation. The capabilities demonstrated here also suggest that high definition recoil imaging in gas TPCs is applicable to low energy, low-background experiments, such as directional dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reconstructing the kinematics of deep inelastic scattering with deep learning

We introduce a method to reconstruct the kinematics of neutral-current deep inelastic scattering (DIS) using a deep neural network (DNN). Unlike traditional methods, it exploits the full kinematic information of both the scattered electron and the hadronic-final state, and it accounts for QED radiation by identifying events with radiated photons and event-level momentum imbalance. The method is studied with simulated events at HERA and the future Electron–Ion Collider (EIC). We show that the DNN method outperforms all the traditional methods over the full phase space, improving resolution and reducing bias. Our method has the potential to extend the kinematic reach of future experiments at the EIC, and thus their discovery potential in polarized and nuclear DIS.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Correction of crosstalk effect in the Low Energy RHIC electron Cooler Booster Cavity

we report that the Low Energy Relativistic Heavy Ion Collider (RHIC) electron Cooler (LEReC) is designed to deliver a 1.6 MeV to 2.6 MeV electron beam, with rms dp/p less than 5e-4. The superconducting radiofrequency (SRF) Booster Cavity is the major accelerating component in LEReC. It is a 0.4 cell cavity operating at 2 K, providing a maximum energy gain of 2.2 MeV. It is modified from an experimental Energy Recovery Linac (ERL) photocathode gun, and thus has fundamental power couplers (FPCs), pickup (PU) couplers (field probes) and HOM coupler close to each other on the same side of the cavity. Direct capacitive coupling between the FPC and PU, called the crosstalk effect, combined with microphonic detuning, can induce closed loop voltage fluctuations that exceed the total energy spread requirement of LEReC. The crosstalk effect in this cavity is modelled, simulated, and measured, and a correction method is proposed and demonstrated to suppress the voltage fluctuation so that energy spread requirement can be met.

43 PARTICLE ACCELERATORS↗

Measurements of beam backgrounds in SuperKEKB Phase 2

The high design luminosity of the SuperKEKB electron-positron collider will result in challenging levels of beam-induced backgrounds in the interaction region. Understanding and mitigating these backgrounds is critical to the success of the Belle II experiment. We report on the first background measurements performed after roll-in of the Belle II detector, utilizing both the BEAST II system of dedicated background sensors and the Belle II detector itself. Here we also report on first revisions to the background simulation made in response to our findings. Backgrounds measured include contributions from synchrotron radiation, beam-gas, Touschek, and injection backgrounds. At the end of Phase 2, single-beam backgrounds originating from the 4 GeV positron Low Energy Ring (LER) agree reasonably well with simulation, while backgrounds from the 7 GeV electron High Energy Ring (HER) are approximately one order of magnitude higher than simulation. We extrapolate these backgrounds forward and conclude it is safe to proceed to installation of the Belle II vertex detector.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗