Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “chip”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Insulator Nanostructure Desorption Ionization Mass Spectrometry

Surface-assisted laser desorption ionization (SALDI) is an approach for gas-phase ion generation for mass spectrometry using laser excitation on typically conductive or semiconductive nanostructures. Here, we introduce insulator nanostructure desorption ionization mass spectrometry (INDI-MS), a nanostructured polymer substrate for SALDI-MS analysis of small molecules and peptides. INDI-MS surfaces are produced through the self-assembly of a perfluoroalkyl silsesquioxane nanostructures in a single chemical vapor deposition silanization-step. We find that surfaces formed from the perfluorooctyltrichlorosilane monomer assemble semielliptical features with a 10 nm height, diameters between 10 and 50 nm, and have attomole–femtomole sensitivities for selected analytes. Surfaces prepared with silanes that either lack the trichloro or perfluoro groups, lack sensitivity. Further, we demonstrate that hydrophobic INDI regions can be micropatterned onto hydrophilic surfaces to perform on-chip self-desalting in an array format.

59 BASIC BIOLOGICAL SCIENCES↗

High-Responsivity Graphene–Boron Nitride Photodetector and Autocorrelator in a Silicon Photonic Integrated Circuit

Graphene and other two-dimensional (2D) materials have emerged as promising materials for broadband and ultrafast photodetection and optical modulation. These optoelectronic capabilities can augment complementary metal–oxide–semiconductor (CMOS) devices for high-speed and low-power optical interconnects. We demonstrate an on-chip ultrafast photodetector based on a two-dimensional heterostructure consisting of high-quality graphene encapsulated in hexagonal boron nitride. Coupled to the optical mode of a silicon waveguide, this 2D heterostructure-based photodetector exhibits a maximum responsivity of 0.36 A/W and high-speed operation with a 3 dB cutoff at 42 GHz. From photocurrent measurements as a function of the top-gate and source-drain voltages, we conclude that the photoresponse is consistent with hot electron mediated effects. At moderate peak powers above 50 mW, we observe a saturating photocurrent consistent with the mechanisms of electron–phonon supercollision cooling. This nonlinear photoresponse enables optical on-chip autocorrelation measurements with picosecond-scale timing resolution and exceptionally low peak powers.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A Versatile Microfluidic Device for Automating Synthetic Biology

New microbes are being engineered that contain the genetic circuitry, metabolic pathways, and other cellular functions required for a wide range of applications such as producing biofuels, biobased chemicals, and pharmaceuticals. Although currently available tools are useful in improving the synthetic biology process, further improvements in physical automation would help to lower the barrier of entry into this field. We present an innovative microfluidic platform for assembling DNA fragments with 10× lower volumes (compared to that of current microfluidic platforms) and with integrated region-specific temperature control and on-chip transformation. Integration of these steps minimizes the loss of reagents and products compared to that with conventional methods, which require multiple pipetting steps. For assembling DNA fragments, we implemented three commonly used DNA assembly protocols on our microfluidic device: Golden Gate assembly, Gibson assembly, and yeast assembly (i.e., TAR cloning, DNA Assembler). Here, we demonstrate the utility of these methods by assembling two combinatorial libraries of 16 plasmids each. Each DNA plasmid is transformed into Escherichia coli or Saccharomyces cerevisiae using on-chip electroporation and further sequenced to verify the assembly. Lastly, we anticipate that this platform will enable new research that can integrate this automated microfluidic platform to generate large combinatorial libraries of plasmids and will help to expedite the overall synthetic biology process.

59 BASIC BIOLOGICAL SCIENCES↗

A Droplet Microfluidic Platform for Automating Genetic Engineering

We present a water-in-oil droplet microfluidic platform for transformation, culture and expression of recombinant proteins in multiple host organisms including bacteria, yeast and fungi. The platform consists of a hybrid digital microfluidic/channel-based droplet chip with integrated temperature control to allow complete automation and integration of plasmid addition, heat-shock transformation, addition of selection medium, culture, and protein expression. The microfluidic format permitted significant reduction in consumption (100-fold) of expensive reagents such as DNA and enzymes compared to the benchtop method. Furthermore, the chip contains a channel to continuously replenish oil to the culture chamber to provide a fresh supply of oxygen to the cells for long-term (~5 days) cell culture. The flow channel also replenished oil lost to evaporation and increased the number of droplets that could be processed and cultured. The platform was validated by transforming several plasmids into Escherichia coli including plasmids containing genes for fluorescent proteins GFP, BFP and RFP; plasmids with selectable markers for ampicillin or kanamycin resistance; and a Golden Gate DNA assembly reaction. We also demonstrate the applicability of this platform for transformation in widely used eukaryotic organisms such as Saccharomyces cerevisiae and Aspergillus Niger. Duration and temperatures of the microfluidic heat-shock procedures were optimized to yield transformation efficiencies comparable to those obtained by benchtop methods with a throughput up to 6 droplets/min. The platform we proposed offers potential for automation of molecular biology experiments significantly reducing cost, time and variability while improving throughput.

59 BASIC BIOLOGICAL SCIENCES↗

Microfluidic Generation of Lipidic Mesophases for Membrane Protein Crystallization

We report on a microfluidic method for the formation of aqueous/lipid mesophases to enable screening of suitable crystallization conditions of membrane proteins from a membrane-like phase in sub-20 nL volumes. This integrated microfluidic chip and the employed mixing strategy address the specific challenges associated with the mixing of fluids of highly different viscosities (here a factor of 30) as well as the non-Newtonian character of the resulting mesophases. The chip requires less than 20 nL of material per condition screened, whereas typically on the order of 10 {micro}L or more is needed for a batch preparation in the present screening methods. We validated our approach with the successful crystallization of the membrane protein bacteriorhodopsin.

59 BASIC BIOLOGICAL SCIENCES↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

ProMAT Calibrator: A Tool for Reducing Experimental Bias in Antibody Microarrays

Our research group has been developing enzyme-linked immunosorbent assays (ELISA) microarray technology for the rapid and quantitative evaluation of biomarker panels. Studies using antibody microarrays are susceptible to systematic bias from the various steps in the experimental process, and these biases can mask biologically significant differences. For this reason, we have developed a calibration system that can identify and reduce systematic bias due to processing factors. Specifically, we developed a sandwich ELISA for green fluorescent protein (GFP) that is included on each chip. The GFP antigen is spiked into each biological sample or standard mixture and the resulting signal is used for calibration across chips. We developed ProMAT Calibrator, an open-source bioinformatics tool, for the rapid visualization and interpretation of the calibrator data and, if desired, data normalization. We demonstrate that data normalization using this system markedly reduces bias from processing factors. Equally useful, this calibrator system can help reveal the source of the bias, thereby facilitating the elimination of the underlying problem.

59 BASIC BIOLOGICAL SCIENCES↗

Liquid-based gating mechanism with tunable multiphase selectivity and antifouling behaviour

Living organisms make extensive use of micro- and nanometre-sized pores as gatekeepers for controlling the movement of fluids, vapours and solids between complex environments. The ability of such pores to coordinate multiphase transport, in a highly selective and subtly triggered fashion and without clogging, has inspired interest in synthetic gated pores for applications ranging from fluid processing to 3D printing and lab-on-chip systems(1-10). But although specific gating and transport behaviours have been realized by precisely tailoring pore surface chemistries and pore geometries(6,11-17), a single system capable of controlling complex, selective multiphase transport has remained a distant prospect, and fouling is nearly inevitable(11,12). Here we introduce a gating mechanism that uses a capillary-stabilized liquid as a reversible, reconfigurable gate that fills and seals pores in the closed state, and creates a non-fouling, liquid-lined pore in the open state. Theoretical modelling and experiments demonstrate that for each transport substance, the gating threshold-the pressure needed to open the pores-can be rationally tuned over a wide pressure range. This enables us to realize in one system differential response profiles for a variety of liquids and gases, even letting liquids flow through the pore while preventing gas from escaping. These capabilities allow us to dynamically modulate gas-liquid sorting in a microfluidic flow and to separate a three-phase air-water-oil mixture, with the liquid lining ensuring sustained antifouling behaviour. Because the liquid gating strategy enables efficient long-term operation and can be applied to a variety of pore structures and membrane materials, and to micro- as well as macroscale fluid systems, we expect it to prove useful in a wide range of applications.

Hou, X↗

Imaging electric field dynamics with graphene optoelectronics

The use of electric fields for signalling and control in liquids is widespread, spanning bioelectric activity in cells to electrical manipulation of microstructures in lab-on-a-chip devices. However, an appropriate tool to resolve the spatio-temporal distribution of electric fields over a large dynamic range has yet to be developed. Here we present a label-free method to image local electric fields in real time and under ambient conditions. Our technique combines the unique gate-variable optical transitions of graphene with a critically coupled planar waveguide platform that enables highly sensitive detection of local electric fields with a voltage sensitivity of a few microvolts, a spatial resolution of tens of micrometres and a frequency response over tens of kilohertz. Our imaging platform enables parallel detection of electric fields over a large field of view and can be tailored to broad applications spanning lab-on-a-chip device engineering to analysis of bioelectric phenomena.

59 BASIC BIOLOGICAL SCIENCES↗

Aerosol jet printing of surface acoustic wave microfluidic devices

Abstract The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Coherent coupling between a quantum dot and a donor in silicon

Individual donors in silicon chips are used as quantum bits with extremely low error rates. However, physical realizations have been limited to one donor because their atomic size causes fabrication challenges. Quantum dot qubits, in contrast, are highly adjustable using electrical gate voltages. This adjustability could be leveraged to deterministically couple donors to quantum dots in arrays of qubits. In this work, we demonstrate the coherent interaction of a 31P donor electron with the electron of a metal-oxide-semiconductor quantum dot. We form a logical qubit encoded in the spin singlet and triplet states of the two-electron system. We show that the donor nuclear spin drives coherent rotations between the electronic qubit states through the contact hyperfine interaction. This provides every key element for compact two-electron spin qubits requiring only a single dot and no additional magnetic field gradients, as well as a means to interact with the nuclear spin qubit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-quality microresonators in the longwave infrared based on native germanium

The longwave infrared (LWIR) region of the spectrum spans 8 to 14 μm and enables high-performance sensing and imaging for detection, ranging, and monitoring. Chip-scale LWIR photonics has enormous potential for real-time environmental monitoring, explosive detection, and biomedicine. However, realizing technologies such as precision sensors and broadband frequency combs requires ultra low-loss and low-dispersion components, which have so far remained elusive in this regime. Here, we use native germanium to demonstrate the first high-quality microresonators in the LWIR. These microresonators are coupled to partially-suspended Ge waveguides on a separate glass chip, allowing for the first unambiguous measurements of isolated linewidths. At 8 μm, we measured losses of 0.5 dB/cm and intrinsic quality (Q) factors of 2.5 × 10 5 , nearly two orders of magnitude higher than prior LWIR resonators. Our work portends the development of novel sensing and nonlinear photonics in the LWIR regime.

47 OTHER INSTRUMENTATION↗

Synchronous detection of cosmic rays and correlated errors in superconducting qubit arrays

Quantum information processing at scale will require sufficiently stable and long-lived qubits, likely enabled by error-correction codes. Several recent superconducting-qubit experiments, however, reported observing intermittent spatiotemporally correlated errors that would be problematic for conventional codes, with ionizing radiation being a likely cause. Here, we directly measured the cosmic-ray contribution to spatiotemporally correlated qubit errors. We accomplished this by synchronously monitoring cosmic-ray detectors and qubit energy-relaxation dynamics of 10 transmon qubits distributed across a 5 × 5 × 0.35 mm 3 silicon chip. Cosmic rays caused correlated errors at a rate of $1/\left(592\begin{array}{c}+48\\ -41\end{array}\,{\rm{s}}\right)$, accounting for 17.1 ± 1.3% of all such events. Our qubits responded to essentially all of the cosmic rays and their secondary particles incident on the chip, consistent with the independently measured arrival flux. Moreover, we observed that the landscape of the superconducting gap in proximity to the Josephson junctions dramatically impacts the qubit response to cosmic rays. Given the practical difficulties associated with shielding cosmic rays, our results indicate the importance of radiation hardening—for example, superconducting gap engineering—to the realization of robust quantum error correction.

Science & Technology - Other Topics↗

Milliwatt-level UV generation using sidewall poled lithium niobate

Integrated coherent sources of ultra-violet (UV) light are essential for a wide range of applications, from ion-based quantum computing and optical clocks to gas sensing and microscopy. Recently, approaches that use frequency upconversion have received considerable attention. Among these, the integrated thin-film lithium niobate (TFLN) photonic platform shows particular promise. However, to date, the high propagation losses and lack of reliable techniques for consistent poling of cm-long waveguides with small poling periods have impeded progress. Here, we present a sidewall poled lithium niobate (SPLN) waveguide approach that overcomes these obstacles and results in a two-orders-of-magnitude increase in generated UV power. We demonstrate SPLN waveguides featuring record-low propagation losses of 2.3 dB/cm, complete domain inversion across the waveguide cross-section, and an optimum 50% duty cycle, resulting in a record-high normalized conversion efficiency of 5050%W$^{−1}$cm$^{−2}$, and 4.2 mW of generated on-chip power at 390 nm wavelength. This advancement makes the TFLN platform a viable option for high-quality on-chip UV generation, benefiting emerging applications.

Franken, C. A.A. [Harvard U.; Twente U., Enschede]↗

Short-depth QAOA circuits and quantum annealing on higher-order ising models

Abstract We present a direct comparison between QAOA (Quantum Alternating Operator Ansatz), and QA (Quantum Annealing) on 127 qubit problem instances. QAOA with p = 1, 2 rounds is executed on the 127 qubit heavy-hex graph gate-model quantum computer ibm_washington, using on-device grid-searches for angle finding, and QA is executed on two Pegasus-chip D-Wave quantum annealers. The problems are random Ising models whose connectivity matches heavy-hex graphs and the Pegasus graph connectivity, and optionally include hardware-compatible cubic terms ( Z Z Z terms). The QAOA circuits are heavily optimized and of extremely short depth, with a CNOT depth of 6 per round, which allows whole chip usage of the heavy-hex lattice. QAOA and QA are both compared against simulated annealing and the optimal solutions are computed exactly using CPLEX. The noiseless mean QAOA expectation values for p = 1, 2 are computed using classical light-cone based simulations. We find QA outperforms QAOA on the evaluated devices.

127 qubits↗

Vibrational fingerprints of ferroelectric HfO 2

Hafnia (HfO 2 ) is a promising material for emerging chip applications due to its high-κ dielectric behavior, suitability for negative capacitance heterostructures, scalable ferroelectricity, and silicon compatibility. The lattice dynamics along with phononic properties such as thermal conductivity, contraction, and heat capacity are under-explored, primarily due to the absence of high quality single crystals. Herein, we report the vibrational properties of a series of HfO 2 crystals stabilized with yttrium (chemical formula HfO2: xY, where x = 20, 12, 11, 8, and 0%) and compare our findings with a symmetry analysis and lattice dynamics calculations. We untangle the effects of Y by testing our calculations against the measured Raman and infrared spectra of the cubic, antipolar orthorhombic, and monoclinic phases and then proceed to reveal the signature modes of polar orthorhombic hafnia. This work provides a spectroscopic fingerprint for several different phases of HfO 2 and paves the way for an analysis of mode contributions to high-κ dielectric and ferroelectric properties for chip technologies.

36 MATERIALS SCIENCE↗

Axon-like active signal transmission

Any electrical signal propagating in a metallic conductor loses amplitude due to the natural resistance of the metal. Compensating for such losses presently requires repeatedly breaking the conductor and interposing amplifiers that consume and regenerate the signal. This century-old primitive severely constrains the design and performance of modern interconnect-dense chips. Here we present a fundamentally different primitive based on semi-stable edge of chaos (EOC), a long-theorized but experimentally elusive regime that underlies active (self-amplifying) transmission in biological axons. By electrically accessing the spin crossover in LaCoO 3 , we isolate semi-stable EOC, characterized by small-signal negative resistance and amplification of perturbations. In a metallic line atop a medium biased at EOC, a signal input at one end exits the other end amplified, without passing through a separate amplifying component. While superficially resembling superconductivity, active transmission offers controllably amplified time-varying small-signal propagation at normal temperature and pressure, but requires an electrically energized EOC medium. Operando thermal mapping reveals the mechanism of amplification—bias energy of the EOC medium, instead of fully dissipating as heat, is partly used to amplify signals in the metallic line, thereby enabling spatially continuous active transmission, which could transform the design and performance of complex electronic chips.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Functional and transcriptional characterization of complex neuronal co-cultures

Brain-on-a-chip systems are designed to simulate brain activity using traditional in vitro cell culture on an engineered platform. It is a noninvasive tool to screen new drugs, evaluate toxicants, and elucidate disease mechanisms. However, successful recapitulation of brain function on these systems is dependent on the complexity of the cell culture. In this study, we increased cellular complexity of traditional (simple) neuronal cultures by co-culturing with astrocytes and oligodendrocyte precursor cells (complex culture). We evaluated and compared neuronal activity (e.g., network formation and maturation), cellular composition in long-term culture, and the transcriptome of the two cultures. Compared to simple cultures, neurons from complex co-cultures exhibited earlier synapse and network development and maturation, which was supported by localized synaptophysin expression, up-regulation of genes involved in mature neuronal processes, and synchronized neural network activity. Also, mature oligodendrocytes and reactive astrocytes were only detected in complex cultures upon transcriptomic analysis of age-matched cultures. Functionally, the GABA antagonist bicuculline had a greater influence on bursting activity in complex versus simple cultures. Collectively, the cellular complexity of brain-on-a-chip systems intrinsically develops cell type-specific phenotypes relevant to the brain while accelerating the maturation of neuronal networks, important features underdeveloped in traditional cultures.

59 BASIC BIOLOGICAL SCIENCES↗