At least 1,693 records · Page 94

Overcoming Codes and Standards Barriers to Innovations in Building Energy Efficiency

In this journal article, the authors discuss approaches to overcoming building code barriers to energy-efficiency innovations in home construction. Building codes have been a highly motivational force for increasing the energy efficiency of new homes in the United States in recent years. But as quickly as the codes seem to be changing, new products are coming to the market at an even more rapid pace, sometimes offering approaches and construction techniques unthought of when the current code was first proposed, which might have been several years before its adoption by various jurisdictions. Due to this delay, the codes themselves can become barriers to innovations that might otherwise be helping to further increase the efficiency, comfort, health or durability of new homes. . The U.S. Department of Energy’s Building America, a program dedicated to improving the energy efficiency of America’s housing stock through research and education, is working with the U.S. housing industry through its research teams to help builders identify and remove code barriers to innovation in the home construction industry. The article addresses several approaches that builders use to achieve approval for innovative building techniques when code barriers appear to exist.

Building America↗

Double Wall Framing Technique An Example of High Performance, Sustainable Building Envelope Technology

Double wall technologies utilizing wood framing have been well-known and used in North American buildings for decades. Most of double wall designs use only natural materials such as wood products, gypsum, and cellulose fiber insulation, being one of few building envelope technologies achieving high thermal performance without use of plastic foams or fiberglass. Today, after several material and structural design modifications, these technologies are considered as highly thermally efficient, sustainable option for new constructions and sometimes, for retrofit projects. Following earlier analysis performed for U.S. Department of Energy by Fraunhofer CSE, this paper discusses different ways to build double walls and to optimize their thermal performance to minimize the space conditioning energy consumption. Description of structural configuration alternatives and thermal performance analysis are presented as well. Laboratory tests to evaluate thermal properties of used insulation and whole wall system thermal performance are also discussed in this paper. Finally, the thermal loads generated in field conditions by double walls are discussed utilizing results from a joined project performed by Zero Energy Building Research Alliance and Oak Ridge National Laboratory (ORNL), which made possible evaluation of the market viability of low-energy homes built in the Tennessee Valley. Experimental data recorded in two of the test houses built during this field study is presented in this work.

Building Envelope↗

PNNL’s Building Operations Control Center

PNNL's Building Operations Control Center (BOCC) video provides an overview of the center, its capabilities, and its objectives. The BOCC was relocated to PNNL's new 3820 Systems Engineering Building in 2015. Although a key focus of the BOCC is on monitoring and improving the operations of PNNL buildings, the center's state-of-the-art computational, software and visualization resources also have provided a platform for PNNL buildings-related research projects.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida

Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Impact of Slab-Foundation Heat Transfer on Space-Conditioning Energy Use in Florida, Cocoa, Florida

Heat transfer to slab foundations has remained an area of building science with poor understanding over the last three decades of energy efficiency research. This is somewhat surprising since the area of floors in single family homes is generally equal to wall, or windows or attics which have been extensively evaluated. Research that has been done has focused in the impact of slab on grade foundations and insulation schemes on heat losses associated with heating in predominantly heating dominated climates. Slab on grade construction is very popular in cooling-dominated southern states where it accounts for 77 percent of new home floors according to U.S. Census data in 2014. There is a widespread conception that tile flooring, as opposed to carpet, makes for a cooler home interior in warm climates. Empirical research is needed as building energy simulations such as DOE-2 and EnergyPlus rely on simplified models to evaluate these influences. BA-PIRC performed experiments over an entire year from 2014-2015 in FSEC's Flexible Residential Test Facilities (FRTF) intended to assess for the first time 1) slab on grade influence in a cooling dominated climate, and 2) how the difference in a carpeted vs. uncarpeted building might influence heating and cooling. Two identical side by side residential buildings were evaluated, the East with pad and carpet and the west with a bare slab floor. A highly detailed grid of temperature measurements were taken on the slab surface at various locations as well as at depths of 1, 2.5, 5, 10 and 20 feet.

BAPIRC↗

Energy Demand Management in Buildings Using PCM-Integrated Wall

The buildings in the United States annually consume nearly 40% of total U.S. energy consumption and approximately 75% of U.S. electricity consumption. Almost half of the total U.S. energy consumption in buildings is attributed to the space conditioning through Heating, Ventilation, and Air Conditioning (HVAC) systems. Utilizing thermal energy storage in buildings, particularly integrating phase change material (PCM) in the walls, has been reported to be an effective method of managing the space heating and cooling loads. This presentation covers an in-depth discussion on the integration of a PCM to building walls, the key conditions required for effective utilization of the PCM, and effect of the PCM transition temperature and the PCM location on energy-saving potential of the PCM-integrated wall.

building↗

Integrating Electric Vehicle Charging Infrastructure into Commercial Buildings and Mixed-Use Communities: Design, Modeling, and Control Optimization Opportunities: Preprint

This paper discusses modeling and field studies of controlled EV charging that have been performed with the goal of minimizing requirements for infrastructure upgrades, minimizing building peak demand charges, and maximizing the use of on-site generation. We present a large-scale workplace charging pilot of a demand-controlled scheduled EV charging system with over 250 active daily commuters, successfully demonstrating management of aggregate charging power to avoid new infrastructure investments, mitigate peak demand charges, and provide cost-effective workplace charging to users. In addition to understanding opportunities for demand management, integrating these controllable loads into the energy modeling process for new buildings will also be necessary. This paper then presents an example energy modeling process that evaluates the potential effects of EV charging on building load profiles and infrastructure requirements for a mixed-use community. Finally, we discuss an illustration of how EV charging can be controlled to be synergistic with other building loads and distributed generation.

buildings↗

ComStock/COVID-19: U.S. Commercial Building Stock Analysis of COVID-19 Mitigation Strategies

ComStock is a DOE platform, with NREL as the lead developer, that models the U.S. commercial building stock using OpenStudio/EnergyPlus to perform physics-based building energy modeling simulations. The ASHRAE Epidemic Taskforce (ASHRAE-ETF) has released several COVID-19 mitigation strategies for commercial buildings. ComStock was used to analyze the impact of four strategies on the existing commercial building stock. These strategies are upgrading to MERV-13 filters, disabling demand control ventilation (DCV), increasing minimum outdoor air to 100%, and HVAC flushing mode operation. Results show the impact of each measure on energy consumption, electric consumption, gas consumption and peak electric.

30 DIRECT ENERGY CONVERSION↗

U.S. Department of Energy Solar Decathlon Competition Guide: 2022 Design Challenge and 2023 Build Challenge

The Solar Decathlon offers a unique experience that enables collegiate teams to develop critical career skills, learn from both national experts and peers, and gain valuable insights from world class thought leaders and mentors. Specifically, student teams are challenged to design and (if part of the Solar Decathlon Build Challenge) build highly energy-efficient buildings powered by renewable energy. Teams are evaluated on 10 measured contests, and the winning teams are those that best blend the topics of architectural and engineering excellence with innovation, market potential, building efficiency, smart energy production, and environmental justice.

Build Challenge↗

Probabilistic Modeling of Commercial Building Occupancy Patterns Using Location-Based Map Data: Preprint

Considering occupancy patterns is crucial to simulate buildings' energy use. Current energy models use inputs that simplify the actual diversity in occupancy into static occupancy patterns and are not able to represent the numerous variations in occupancy patterns between buildings and across different locations. Recently, inferring occupancy schedules from metered electricity consumption data was used to model occupancy in commercial buildings. However, the translation from metered data to occupancy schedules requires many assumptions that might not capture the reality, and the process is hindered by the availability of data from advanced metering infrastructure. With the development of information technologies, occupancy modeling should not be limited to traditional approaches. The prevalence of social networks and location services with real-time user feedback provides publicly accessible data via Maps Application Programming Interfaces (APIs) such as Google Maps, SafeGraph, Mapbox, Foursquare, etc. This paper presents an automated framework for modeling parametric occupancy patterns using such APIs to calibrate commercial district buildings' energy models. This process includes three main steps: data extraction and processing, parametric schedules generation, and schedules integration. We demonstrated this framework in districts where we used maps API to generate more accurate behavioral patterns for operations and electric vehicle charging events. We used these patterns to determine differences in energy use across key sociodemographic and spatial parameters. The presented method has the potential for worldwide applications. Users can utilize this framework to extract data for selected locations of interest to create more realistic behavioral patterns for commercial facilities across different districts.

building energy modeling↗

The CO2 Reduction Potential of Combined Heat and Power in California's Commercial Buildings

The Ernest Orlando Lawrence Berkeley National Laboratory (LBNL) is working with the California Energy Commission (CEC) to determine the potential role of commercial sector distributed generation (DG) with combined heat and power (CHP) capability deployment in greenhouse gas emissions (GHG) reductions. CHP applications at large industrial sites are well known, and a large share of their potential has already been harvested. In contrast, relatively little attention has been paid to the potential of medium-sized commercial buildings, i.e., ones with peak electric loads ranging from 100 kW to 5 MW. We examine how this sector might implement DG with CHP in cost minimizing microgrids that are able to adopt and operate various energy technologies, such as solar photovoltaics (PV), on-site thermal generation, heat exchangers, solar thermal collectors, absorption chillers, and storage systems. We apply a mixed-integer linear program (MILP) that minimizes a site's annual energy costs as its objective. Using 138 representative mid-sized commercial sites in California (CA), existing tariffs of three major electricity distribution ultilities plus a natural gas company, and performance data of available technology in 2020, we find the GHG reduction potential for this CA commercial sector segment, which represents about 35percent of total statewide commercial sector sales. Under the assumptions made, in a reference case, this segment is estimated to be capable of economically installing 1.4 GW of CHP, 35percent of the California Air Resources Board (CARB) statewide 4 GW goal for total incremental CHP deployment by 2020. However, because CARB's assumed utilization is far higherthan is found by the MILP, the adopted CHP only contributes 19percent of the CO2 target. Several sensitivity runs were completed. One applies a simple feed-in tariff similar to net metering, and another includes a generous self-generation incentive program (SGIP) subsidy for fuel cells. The feed-in tariff proves ineffective at stimulating CHP deployment, while the SGIP buy down is more powerful. The attractiveness of CHP varies widely by climate zone and service territory, but in general, hotter inland areas and San Diego are the more attractive regions because high cooling loads achieve higher equipment utilization. Additionally, large office buildings are surprisingly good hosts for CHP, so large office buildings in San Diego and hotter urban centers emerge as promising target hosts. Overall the effect on CO2 emissions is limited, never exceeding 27percent of the CARB target. Nonetheless, results suggest that the CO2 emissions abatement potential of CHP in mid-sized CA buildings is significant, and much more promising than is typically assumed.

03 NATURAL GAS↗

Co-simulation of innovative integrated HVAC systems in buildings

Integrated performance simulation of buildings HVAC systems can help in reducing energy consumption and increasing occupant comfort. However, no single building performance simulation (BPS) tool offers sufficient capabilities and flexibilities to analyze integrated building systems and to enable rapid prototyping of innovative building and system technologies. One way to alleviate this problem is to use co-simulation, as an integrated approach to simulation. This article elaborates on issues important for co-simulation realization and discusses multiple possibilities to justify the particular approach implemented in the here described co-simulation prototype. The prototype is validated with the results obtained from the traditional simulation approach. It is further used in a proof-of-concept case study to demonstrate the applicability of the method and to highlight its benefits. Stability and accuracy of different coupling strategies are analyzed to give a guideline for the required coupling time step.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Load Profiles for the U.S. Building Stock

The United States is embarking on an ambitious transition to a 100% clean energy economy by 2050, which will require improving the flexibility of electric grids. One way to achieve grid flexibility is to shed or shift demand to align with changing grid needs. To facilitate this, it is critical to understand how and when energy is used. High quality end-use load profiles (EULPs) provide this information, and can help cities, states, and utilities understand the time-sensitive value of energy efficiency, demand response, and distributed energy resources. Publicly available EULPs have traditionally had limited application because of age and incomplete geographic representation. To help fill this gap, the U.S. Department of Energy (DOE) funded a three-year project, End-Use Load Profiles for the U.S. Building Stock, that culminated in this publicly available dataset of calibrated and validated 15-minute resolution load profiles for all major residential and commercial building types and end uses, across all climate regions in the United States. These EULPs were created by calibrating the ResStock and ComStock physics-based building stock models using many different measured datasets, as described in the "Technical Report Documenting Methodology" linked in the submission.

Array↗

Assessment of the Technical Potential for Achieving Net Zero-Energy Buildings in the Commercial Sector

This report summarizes the findings from research conducted at NREL to assess the technical potential for zero-energy building technologies and practices to reduce the impact of commercial buildings on the U.S. energy system. Commercial buildings currently account for 18% of annual U.S. energy consumption, and energy use is growing along with overall floor area. Reducing the energy use of this sector will require aggressive research goals and rapid implementation of the research results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Occupant behavior models: A critical review of implementation and representation approaches in building performance simulation programs

Occupant behavior (OB) in buildings is a leading factor influencing energy use in buildings. Quantifying this influence requires the integration of OB models with building performance simulation (BPS). This study reviews approaches to representing and implementing OB models in today’s popular BPS programs, and discusses weaknesses and strengths of these approaches and key issues in integrating of OB models with BPS programs. Two of the key findings are: (1) a common data model is needed to standardize the representation of OB models, enabling their flexibility and exchange among BPS programs and user applications; the data model can be implemented using a standard syntax (e.g., in the form of XML schema), and (2) a modular software implementation of OB models, such as functional mock-up units for co-simulation, adopting the common data model, has advantages in providing a robust and interoperable integration with multiple BPS programs. Such common OB model representation and implementation approaches help standardize the input structures of OB models, enable collaborative development of a shared library of OB models, and allow for rapid and widespread integration of OB models with BPS programs to improve the simulation of occupant behavior and quantification of their impact on building performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermal characterization of the build chamber in electron beam melting

Electron beam powder bed fusion, commonly termed electron beam melting (EBM), offers great versatility in multiple-part processes and can produce high quality as-built components due to low residual stresses. The EBM process is complex and requires careful thermal management, including uniform and consistent preheating of the powder bed, in order to ensure quality and consistency of the product. However, most of the simulations in the literature focus on the selective melting stage of the process. As of today, optimal conditions for initial pre-heating temperatures are only available for specific materials. Thus, in order to extend the EBM technology to other desired build materials, a much better understanding of the pre-heating stages is required. In this work, numerical and experimental approaches are combined in order to investigate the effects and sensitivities of heat removal from the build plate during EBM pre-heating stages. For this purpose, a carefully reconstructed numerical model of the build chamber of an ARCAM Q20 + machine is developed. It includes all main parts of the chamber and all relevant heat transfer mechanisms, whereas special attention is paid to radiation heat exchange between various bodies. In order to validate the model, dedicated experiments are performed, in which a system of thermocouples is installed in the build chamber, allowing direct measurement of the local temperatures of the start-plate and heat shields. A good agreement between the simulation and experimental findings is achieved, leading to a better understanding of the thermal processes characteristic to the pre-heating stages. This basic analysis is followed by a representative pre-heating case, where a powder bed is also considered. The energy required to obtain the desired pre-heating temperatures is evaluated, and the role of the powder bed in heat transfer within the chamber is assessed. The pre-heating stage, simulated in the present work, is supposed to create proper conditions for sintering and consequent melting of the powder, which are highly dependent on the local temperatures and heat transfer features. Thus, the findings of the reported work present a step towards a better understanding of the thermal processes that characterize EBM. The reported model can be further used to provide realistic boundary condition inputs for other meso- or macro-scale models as a function of time and geometry. The model can serve also for verification of machine settings, i.e., jump-safe and melt-safe ones which actually provide desired preheat, and for development of settings for new powders.

36 MATERIALS SCIENCE↗

Improving the accuracy of energy baseline models for commercial buildings with occupancy data

More than 80% of energy is consumed during operation phase of a building's life cycle, so energy efficiency retrofit for existing buildings is considered a promising way to reduce energy use in buildings. The investment strategies of retrofit depend on the ability to quantify energy savings by “measurement and verification” (M&V), which compares actual energy consumption to how much energy would have been used without retrofit (called the “baseline” of energy use). Although numerous models exist for predicting baseline of energy use, a critical limitation is that occupancy has not been included as a variable. However, occupancy rate is essential for energy consumption and was emphasized by previous studies. This study develops a new baseline model which is built upon the Lawrence Berkeley National Laboratory (LBNL) model but includes the use of building occupancy data. The study also proposes metrics to quantify the accuracy of prediction and the impacts of variables. However, the results show that including occupancy data does not significantly improve the accuracy of the baseline model, especially for HVAC load. The reasons are discussed further. In addition, sensitivity analysis is conducted to show the influence of parameters in baseline models. To conclude, the results from this study can help us understand the influence of occupancy on energy use, improve energy baseline prediction by including the occupancy factor, reduce risks of M&V and facilitate investment strategies of energy efficiency retrofit.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Personal thermal management using portable thermoelectrics for potential building energy saving

Heating and cooling of buildings consume approximately 15% of all energy used in the United States. Such a large energy demand is primarily due to heating and cooling of the entire building space to temperature setpoints usually between 21.1 degrees C (70 degrees F) and 23.9 degrees C (75 degrees F). However, even with such a narrow range of temperature setpoints, more than 20% of the occupants do not feel thermally comfortable due to individual differences (e.g. age, gender, clothing, or physiology). The personal thermal management techniques, which create a local thermal envelope around a human body instead of heating or cooling the entire building space, have the potential to greatly reduce the building energy consumption and to enhance thermal comfort of individuals. In this study, a portable thermoelectric energy conversion unit (TECU) that converts electricity into cooling and heating energy is developed. The TECU supplies cool air (in the cooling mode) or warm air (in the heating mode) to regulate the thermal comfort of a human body. The cool or warm air is supplied through a tree-like rubber tube network that is knitted into a thermoregulatory undergarment. To achieve a cooling/heating target that provides satisfactory thermal comfort, the required cooling/heating power supply from the TECU is determined first while a theoretical model is then developed to guide the design of the TECU. To minimize the TECU weight and make it suitable for portable applications, relationships between weight and thermal resistances of commercial off-the-shelf heat sinks are established first, and a method to find the minimal weight of heat sinks for the TECU is then developed. This methodology is also applicable for other applications where heat sink weight needs to be minimized. The thermal manikin tests demonstrate that 24.6 W of personal cooling power and 18.5 W of personal heating power are achieved by using the TECU.