Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “better”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Phenomenological Constitutive Modeling of High-Temperature Flow Behavior Incorporating Individual and Coupled Effects of Processing Parameters in Super-austenitic Stainless Steel

A novel constitutive model has been developed for predicting flow responses of super-austenitic stainless steel over a wide range of strains (0.05-0.6), temperatures (1173-1423 K) and strain rates (0.001-1 s{sup −1}). Further, the predictability of this new model has been compared with the existing Johnson–Cook (JC) and modified Zerilli–Armstrong (M-ZA) model. The JC model is not befitted for flow prediction as it is found to be exhibiting very high (~ 36%) average absolute error (δ) and low (~ 0.92) correlation coefficient (R). On the contrary, the M-ZA model has demonstrated relatively lower δ (~ 13%) and higher R (~ 0.96) for flow prediction. The incorporation of couplings of processing parameters in M-ZA model has led to exhibit better prediction than JC model. However, the flow analyses of the studied alloy have revealed the additional synergistic influences of strain and strain rate as well as strain, temperature, and strain rate apart from those considered in M-ZA model. Hence, the new phenomenological model has been formulated incorporating all the individual and synergistic effects of processing parameters and a ‘strain-shifting’ parameter. The proposed model predicted the flow behavior of the alloy with much better correlation and generalization than M-ZA model as substantiated by its lower δ (~ 7.9%) and higher R (~ 0.99) of prediction.

36 MATERIALS SCIENCE↗

Comparative Atmospheric Corrosion Behavior of a Mild Steel and an Interstitial Free Steel

The present work discusses the effect of structure and morphology of rust on the corrosion behavior of a mild steel and an interstitial free steel exposed to open atmosphere for 2 years involving extreme weather conditions, where temperature varies from 2-3 to 45 °C, rainfall varies from 10 to 320 mm and humidity varies from ~ 20 to 75%. Effect of duration of atmospheric exposure, change in morphological characteristics of rust, and atmospheric parameters, such as temperature, humidity, rain and SO{sub 2} content on the corrosion behavior of both the steels was analyzed. Corrosion resistance of the interstitial free steel was better than the mild steel due to lower carbon content and better compactness of the rusts formed on the interstitial free steel.

36 MATERIALS SCIENCE↗

Comparative Study of Oxides Formed on Fusion Zone and Base Metal of Laser Welded Zr-1.0Sn-1.0Nb-0.1Fe Alloy

Numerous studies have primarily focused on the corrosion mechanism of zirconium alloy base metal. However, the corrosion resistance of weld beads or seams is of vital importance in the degradation of structural components in the reactor. In the present work, the corrosion resistance of the fusion zone and base metal of laser welded zirconium alloy joints was comparatively investigated. The microstructure morphologies, phase structures and strain fields of oxide films formed on fusion zone and base metal were observed and analyzed. The oxide thickness of the fusion zone was thicker than that of the base metal with prolonged corrosion. Compared to the base metal, the lower density of dislocations and level of strain values in the oxide film of the fusion zone indicated that the stress in the oxide film was lower. The phase transition from the tetragonal ZrO{sub 2} to the monoclinic ZrO{sub 2} could be suppressed due to the high level of stress, resulting in the better corrosion resistance of the base metal. Moreover, the second phase particles and non-βZr phase in the base metal contributed to the better corrosion resistance.

36 MATERIALS SCIENCE↗

Cyclic Thermal Oxidation Evaluation to Improve Ti6Al4V Surface in Applications as Biomaterial

Thermal oxidation treatments are widely used to modify titanium surfaces. Thermally oxidized titanium alloys are used as biomaterials due to their better surface properties, such as corrosion resistance. However, the use of cyclic thermal treatment for this purpose has not yet been reported. This paper’s objective was to compare roughness, microhardness and corrosion resistance after cyclic and conventional isothermal heat treatments in a Ti6Al4V alloy. The heat treatments were performed over a period of 24 h with a maximum temperature of 650 °C, and cyclic conditions were executed from 200 to 400 °C for 48 cycles, each lasting 0.5 h. After the thermal treatments, roughness was measured through profilometer and atomic force microscopy, Vickers microhardness was evaluated, and polarization corrosion tests were performed in simulated body fluid. All treatments increased surface roughness, microhardness and corrosion resistance at 500 mV above open-circuit potential in polarization tests, compared to the material without oxidation. These results are associated with rutile formation, observed through XRD analysis. Although the isothermal and cyclic treatments presented similar behaviors, the 650-200 °C cyclic heat treatment provided an intermediate roughness and produced a slightly better corrosion resistance, demonstrating that cyclic thermal treatments are a viable alternative for improving titanium alloy surface properties.

36 MATERIALS SCIENCE↗

Hot Corrosion Behavior of Ni20Cr Alloy in NaVO{sub 3} Molten Salt

The hot corrosion behavior of Ni20Cr alloy was evaluated in NaVO{sub 3} at temperatures of up to 700 °C and compared to Inconel 600. The performance of both the alloys was evaluated using electrochemical measurements, such as potentiodynamic polarization, linear polarization resistance, and electrochemical impedance spectroscopy measurements, as well as a cyclic corrosion test. The results show that the Ni20Cr alloy has better corrosion performance than the Inconel 600. The better performance of the Ni20Cr alloy was due to its ability to develop a stable protector oxide (Cr{sub 2}O{sub 3}) on its surface.

36 MATERIALS SCIENCE↗

Microstructure Evolution, Structural Integrity, and Hot Corrosion Performance of Nitrogen-Enhanced Stainless Steel Welds

This work articulated the multi-pass, gas tungsten arc welding by adopting pulsating current for joining nitrogen-enhanced, low-carbon austenitic stainless steel, AISI 316L(N). An austeno-ferrite stainless steel (ER2594) and an over-alloyed (ERNiCrMo-3) fillers were employed to join 6-mm-thick plates of AISI 316L(N). Acicular and lathy ferrite in the weld zone of ER2594 and the occurrence of secondary phases in the fusion zone of over-alloyed filler were observed. The notch tensile strength data attested that the joint strength was greater for the welds employing an over-alloyed filler. This study also affirms that the welds obtained with ER2594 filler resulted in better impact toughness (144 J) compared with ERNiCrMo-3 filler and base metal. Also the notch impact toughness of ER2594 weldment is increased to 60% in comparison with that of candidate metal. Corrosion studies were also performed by exposing the coupons in a eutectic salt mixture comprising of 40%K{sub 2}SO{sub 4}-60%NaCl for 50 cycles at 650 °C. It is observed that the weld zone employing over-alloyed filler experienced better high-temperature corrosion resistance compared to the base metal. The specific results of this investigation will be of greater demand to the nuclear and marine applications utilizing these joints.

36 MATERIALS SCIENCE↗

Mg-3Zn/HA Biodegradable Composites Synthesized via Spark Plasma Sintering for Temporary Orthopedic Implants

In the present study, an attempt has been made to improve the mechanical properties, biocompatibility and degradation rate of Mg/3Zn matrix composite, by reinforcing with chemically inert and osteoconductive hydroxyapatite (HA). The composites were synthesized through spark plasma sintering for better consolidation. The HA content, in Mg/3Zn matrix, was optimized with an aim of improving mechanical behavior, corrosion resistance and biocompatibility simultaneously. It has been observed that reinforcement with 15 wt.% HA could slow down the corrosion rate by ~ 60% and improve the hardness and compression strength by ~ 42.8 and 18%, respectively. In vitro studies, up to 56 days, unveil the effect of HA reinforcement in corrosion resistance of magnesium-based matrix. Osteoblastic activity has shown better cell proliferation on the composite surfaces, which were reinforced with HA.

36 MATERIALS SCIENCE↗

Mechanical Behavior of Lead at High Strain Rates

This paper presents a study on the material behaviors and constitutive models of lead at high strain rates. Quasi-static compressive tests and split Hopkinson pressure bar (SHPB) tests were conducted at room temperature. The results of the SHPB tests were verified by high-speed photography, and the error of strain is less than 3% at high strain rate (5000/s). Our results show that the yield stress and flow stress increase at high strain rates. This result indicates that lead is sensitive to the strain rate at high strain rates, but the dependence is not linear during 3000-5000/s. The strain-rate dependence of lead was fitted by a quadratic polynomial curve. To describe the nonlinear strain-rate relationship of lead, modified Johnson–Cook and Cowper–Symonds material models were used to fit the experimental stress–strain curves. The modified Cowper–Symonds model agrees better with the experimental results and can better describe the dynamic mechanical behavior of lead under high strain rates.

36 MATERIALS SCIENCE↗

Microstructure, Mechanical Properties and Residual Stress of Selective Laser Melted AlSi10Mg

AlSi10Mg processed by selective laser melting (SLM) is common in various industries because of its complex structure and high performance. The microstructure, residual stress and mechanical properties restrict its application, while they are affected by the scanning path type and preheating temperature. In this work, to investigate the properties of selective laser melted AlSi10Mg alloys and gain better performance results, the microstructure and mechanical tests are performed at several preheating temperatures based on the uniformity and chessboard scanning strategy. It is found that the selective laser melted AlSi10Mg parts fabricated in the chessboard scanning path have better mechanical properties than those fabricated in the uniformity scanning path. Furthermore, a higher preheating temperature can induce less residual stress due to the enhanced Al crystal faces. Finally, analyses of the microstructures, mechanical and residual stress provide a valuable suggestion that the combination of the range of preheating temperature and the scanning path can improve the performance of selective laser melted AlSi10Mg.

36 MATERIALS SCIENCE↗

Computation of Effective Radiative Properties of Powders for Selective Laser Sintering Simulations

Selective laser sintering (SLS) is an additive manufacturing technique for rapidly creating parts directly from a computer-aided design (CAD) model by using a laser to fuse successive layers of powder. However, better understanding of the effect of particle-level variations on the overall build quality is needed. In this work, we investigated these effects computationally by considering the role of the particle size distribution and variations in the powder bed depth to mimic the part complexity found in overhangs and protrusions. In addition, the results from these studies can be distilled to obtain better effective material properties such as laser absorptivity and laser extinction coefficient that are needed for continuum models of the process. We implement a Monte Carlo ray-tracing algorithm within the discrete element model in the open-source simulation software MFiX. Random, loose-packed, particle bed structures are generated, and effective absorptivity and extinction coefficients are calculated. Results are compared against previous computational and experimental measurements for free, monodisperse, and deep powder beds, with good agreement being obtained. Correlations along with uncertainties are developed to allow the effective absorptivity and extinction coefficient as a function of various particle and operational parameters to be accurately set in SLS macroscale models.

Moser, Daniel↗

Enhanced Mechanical Properties and Wear Resistance of FeCrAl Alloys at ~ 300°C and Higher Temperatures

Abstract Worldwide, light water reactors (LWRs) have been using zirconium (Zr)-based alloys for the cladding of the uranium dioxide fuel for more than 6 decades. Zr alloys oxidize rapidly in the presence of water and steam at temperatures > 450°C; therefore, they do not respond well to scenarios of loss of coolant accidents. There is a global effort by nuclear materials technologists to find more robust or stronger cladding materials for LWRs. One option is to use an iron-chromium-aluminum (FeCrAl) alloy since they have excellent resistance to high temperature oxidation and superior mechanical properties at LWR operation temperatures. Results show that (1) FeCrAl alloys have better mechanical properties than Zr alloy and are orders of magnitude more resistant to creep at temperatures higher than LWR normal operation conditions. (2) FeCrAl alloys have better resistance to fretting wear than Zr alloys at the normal operation conditions of LWRs.

Materials Science↗

Timing of treatment in small-cell lung cancer

Small-cell lung cancer (SCLC) is an aggressive disease with poor survival and rapid doubling time. Current practice is to treat SCLC as soon as possible but evidence on appropriate timing of treatment from diagnosis (TTD) is lacking. This is a retrospective analysis of SCLC patients from the 2012 to 2015 Kentucky Cancer Registry. Data collected included age at diagnosis, stage, gender, race, insurance and treatment. Factors and survival associated with TTD were identified with logistic regression analyses and Cox proportional hazards models. Among the 2992 SCLC patients, 2371 (79%) of SCLC patients were treated with one or more treatment modalities. Among treated patients, 93% received chemotherapy ± radiation with the mean TTD of 18 days. Most patients (80%) have TTD of ≤ 4 weeks with 33% treated within 1 week, 20% 1–2 weeks, and 27% 2–4 weeks from diagnosis. Delay in treatment (TTD > 4 weeks) was less in stage III and IV disease (odds ratio: 0.33 and 0.27 respectively, p < 0.01) but not significantly associated with age, race, gender, and insurance. One and two-year survival of patients with TTD ≤ 4 weeks was significantly worse when compared to > 4 weeks (hazard ratio = 1.43, 95% CI 1.2–1.6, p < 0.01; HR = 1.45, 95% CI 1.3–1.6, p < 0.01 respectively). These results show a trend toward better survival with late treatment of SCLC. Therefore, a general urgency to treat SCLC needs to be re-evaluated with consideration of patients needing more optimization before treatment. Further studies are needed to better clarify the appropriate timing of treatment from diagnosis in SCLC and who will benefit from early versus late treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prediction of long-term (> 10 year) cardiovascular outcomes in heart transplant recipients: Value of stress technetium-99m tetrofosmin myocardial perfusion imaging

Background: Myocardial perfusion imaging (MPI) using single-photon emission computed tomography (SPECT) is useful in the evaluation of cardiac allograft vasculopathy (CAV) in heart transplant (HTx) recipients. The current study evaluated the long-term prognostic value of stress SPECT MPI for predicting all-cause mortality and cardiac events in HTx recipients. Methods: The study population consisted of 166 HTx recipients (mean age 54 ± 10 years, 84% male) who underwent exercise or dobutamine stress {sup 99m}Tc-tetrofosmin SPECT MPI for the assessment of CAV. An abnormal SPECT MPI was defined as the presence of a fixed or a reversible perfusion defect. Endpoints were all-cause mortality, cardiac mortality, and non-fatal myocardial infarction (MI). Results: MPI abnormalities were detected in 55 patients (33%), including fixed defects in 28 patients (17%), partially reversible in 17 patients (10%), and completely reversible defects in 10 patients (6%). During a median follow-up of 12.8 years (range 0-15, mean follow-up 9.5 years), 109 (66%) patients died (all-cause mortality), of which 67 (40%) were due to cardiac causes. A total of 5 (3%) patients experienced a non-fatal MI. HTx recipients with a normal stress {sup 99m}Tc-tetrofosmin SPECT MPI had a significantly better prognosis as compared with those with an abnormal study, up to 5 years after the initial test. The presence of a reversible perfusion defect was a significant predictor of all-cause mortality, cardiac mortality, and major cardiac events, during the entire follow-up period. Conclusions: Stress {sup 99m}Tc-tetrofosmin SPECT MPI provides valuable prognostic information for the prediction of long-term outcome in HTx recipients. Patients with a normal stress {sup 99m}Tc-tetrofosmin SPECT MPI have a significantly better prognosis as compared with those with an abnormal study, up to 5 years after initial testing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship of left ventricular global longitudinal strain with cardiac autonomic denervation as assessed by {sup 123}I-mIBG scintigraphy in patients with heart failure with reduced ejection fraction submitted to cardiac resynchronization therapy

Background: Heart failure (HF) is associated with cardiac autonomic denervation (AD), which can be non-invasively assessed by {sup 123}I-metaiodobenzylguanidine ({sup 123}I-mIBG) scintigraphy and has prognostic implications. We aimed to study the relationship between myocardial contractility assessed by global longitudinal strain (GLS) and AD assessed by {sup 123}I-mIBG scintigraphy in advanced HF. Methods/Results: BETTER-HF is a prospective randomized clinical trial including HF patients (pts) submitted to cardiac resynchronization therapy (CRT) who are submitted to a clinical, echocardiographic, and scintigraphic assessment before and 6 months after CRT. 81 pts were included. An echocardiographic response (absolute increase in left ventricular ejection fraction ≥ 10%) was observed in 73.7% of pts. A higher baseline late heart-to-mediastinum ratio (HMR) was associated with a better echocardiographic response. There was a significant association between late HMR and GLS at baseline and 6 months. At baseline, GLS had an AUC of 0.715 for discrimination for a late HMR < 1.6. A GLS cut-off of − 9% maximized the likelihood of correctly classifying a pt as having severe AD (HMR < 1.6). Conclusion: Myocardial contractility as assessed by GLS is moderately correlated with AD as assessed by {sup 123}I-mIBG scintigraphy and has a good discrimination for the identification of severe cardiac denervation. GLS may allow for a more readily accessible estimation of the degree of AD in advanced HF pts.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improving mine safety technology and training in the U.S. recommendations of the Mine Safety Technology and Training Commission

The key issues studied focused on underground coal mining and included (1) prevention of explosions in sealed areas, (2) better emergency preparedness and response, (3) improvement of miners' ability to escape, (4) better protection of miners before and after a fire or explosion, (5) improved provision of oxygen, and (6) development and implementation of more robust post-incident communication. The U.S. Congress passed the Mine Improvement and New Emergency Response Act of 2006, which mandated new laws to address the issues. Concurrent with investigations and congressional deliberations, the National Mining Association formed the independent Mine Safety Technology and Training Commission to study the state-of-the-art relative to technology and training that could address the vulnerabilities exposed by the mine disasters. As discussed, the report outlined persistent vulnerabilities linked with significant hazards in underground coal mines, and made recommendations to provide a path for addressing them. Overall the commission report made 75 recommendations in the areas of risk-based design and management, communications technology, emergency response and mine rescue procedures, training for preparedness, and escape and protection strategies. In its deliberations, the commission importantly noted that mine safety in the U.S. needs to follow a new paradigm for ensuring mine safety and developing a culture of prevention that supports safe production at the business core. In the commission's viewpoint, the bottom line in protecting coal miners is not only adopting a culture of prevention but also systematically pursuing mitigation of significant risks. 4 refs., 2 figs.

01 COAL, LIGNITE, AND PEAT↗

Diagnostic assessment of reservoir response to fracturing: a case study from Hydraulic Fracturing Test Site (HFTS) in Midland Basin

Abstract This paper outlines a data collection and diagnostics case study involving multiple horizontal shale wells. We look at well production profiles using rate transient analysis, differences in near wellbore complexity, geologic variations within the area of interest, as well as compositional differences in the rocks based on cores obtained from within the stimulated reservoir. The Hydraulic Fracturing Test Site is a multi-well experiment involving stimulation of unconventional shale wells in the southeastern Midland portion of the Permian Basin. The targeted formations include both the upper as well as the middle Wolfcamp formations, also referred alternatively as Wolfcamp A and Wolfcamp B. Data integration and analysis shared in this paper help us understand the various geologic controls impacting well productivity, particularly the wide variance observed between the Wolfcamp A and Wolfcamp B formations. Rate transient analysis indicates similar system permeabilities for stimulated wells. However, we observe higher effective fracture half-lengths for upper Wolfcamp wells. Using observations from 3D seismic interpretations (such as pad scale faults) as well as petrophysical and image log data, we highlight the substantial differences in stimulation as we move along the well laterals from the heel toward the toe sections. These differences are further reconciled with observations from zones with high data density at the core locations through stimulated rock, as well as independent data such as microseismic emissions. At the test site, Wolfcamp A was found to be relatively quartz rich with significant heterogeneity whereas Wolfcamp B is richer in clay and organic content. This impacts the geomechanical characteristics of the rock mass with much higher natural fracture density in the shallower interval. Thus, the fracture growth is more uniform in the deeper interval and more heterogeneous with branching likely in upper interval. Increased complexity also leads to consistently better productivity from the wells in the shallower interval as demonstrated from RTA results. This case study is unique because it provides valuable insights from actual sampling of the stimulated zones in hydraulically fractured wells and helps understand impact of various factors that contribute toward variability in well production. The findings from this study provides insights into need for optimization of completion designs in the various Wolfcamp landing zones, such as optimization of cluster or fracture spacing in various Wolfcamp intervals. In addition, it provides a useful template for data collection and research direction in future field test sites of similar nature in unconventional reservoirs.

Energy & Fuels↗

Argon Cluster Sputtering Source for ToF-SIMS Depth Profiling of Insulating Materials: High Sputter Rate and Accurate Interfacial Information

For the first time, the use of an argon cluster ion sputtering source has been demonstrated to perform superiorly relative to traditional oxygen and cesium ion sputtering sources for ToF-SIMS depth profiling of insulating materials. The superior performance has been attributed to effective alleviation of surface charging. A simulated nuclear waste glass, SON68, and layered hole-perovskite oxide thin films were selected as model systems due to their fundamental and practical significance. Our study shows that if the size of analysis areas is same, the highest sputter rate of argon cluster sputtering can be 2-3 times faster than the highest sputter rates of oxygen or cesium sputtering. More importantly, high quality data and high sputter rates can be achieved simultaneously for argon cluster sputtering while this is not the case for cesium and oxygen sputtering. Therefore, for deep depth profiling of insulating samples, the measurement efficiency of argon cluster sputtering can be about 6-15 times better than traditional cesium and oxygen sputtering. Moreover, for a SrTiO3/SrCrO3 bi-layer thin film on a SrTiO3 substrate, the true 18O/16O isotopic distribution at the interface is better revealed when using the argon cluster sputtering source. Therefore, the implementation of an argon cluster sputtering source can significantly improve the measurement efficiency of insulating materials, and thus can expand the application of ToF-SIMS to the study of glass corrosion, perovskite oxide thin films, and many other potential systems.

Environmental Molecular Sciences Laboratory↗

Towards High-Resolution Tissue Imaging Using Nanospray Desorption Electrospray Ionization Mass Spectrometry Coupled to Shear Force Microscopy

Constant mode ambient mass spectrometry imaging (MSI) of tissue sections with high lateral resolution of better than 10 μm was performed by combining shear force microscopy with nanospray desorption electrospray ionization (nano-DESI). Shear force microscopy enabled precise control of the distance between the sample and nano-DESI probe during MSI experiments and provided information on sample topography. Proof-of-concept experiments were performed using lung and brain tissue sections representing spongy and dense tissues, respectively. Topography images obtained using shear force microscopy were comparable to the results obtained using contact profilometry over the same region of the tissue section. Variations in tissue height were found to be dependent on the tissue type and were in the range of 0–5 μm for lung tissue and 0–3 μm for brain tissue sections. Ion images of phospholipids obtained in this study are in good agreement with literature data. Normalization of nano-DESI MSI images to the signal of the internal standard added to the extraction solvent allowed us to construct high-resolution ion images free of matrix effects. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗