Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “accelerator design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Ions Beams and Ferroelectric Plasma Sources

Near-perfect space-charge neutralization is required for the transverse compression of high perveance ion beams for ion-beam-driven warm dense matter experiments, such as the Neutralized Drift Compression eXperiment (NDCX). Neutralization can be accomplished by introducing a plasma in the beam path, which provides free electrons that compensate the positive space charge of the ion beam. In this thesis, charge neutralization of a 40~keV, perveance-dominated Ar$^+$ beam by a Ferroelectric Plasma Source (FEPS) is investigated. First, the parameters of the ion beam, such as divergence due to the extraction optics, charge neutralization fraction, and emittance were measured. The ion beam was propagated through the FEPS plasma, and the effects of charge neutralization were inferred from time-resolved measurements of the transverse beam profile. In addition, the dependence of FEPS plasma parameters on the configuration of the driving pulser circuit was studied to optimize pulser design. An ion accelerator was constructed that produced a 30-50~keV Ar$^+$ beam with pulse duration $<$300~$\mu$s and dimensionless perveance $Q$ up to 8$\times$10$^{-4}$. Transverse profile measurements 33~cm downstream of the ion source showed that the dependence of beam radius on $Q$ was consistent with space charge expansion. It was concluded that the beam was perveance-dominated with a charge neutralization fraction of approximately zero in the absence of neutralizing plasma. Since beam expansion occurred primarily due to space charge, the decrease in effective perveance due to neutralization by FEPS plasma can be inferred from the reduction in beam radius. Results on propagation of the ion beam through FEPS plasma demonstrate that after the FEPS is triggered, the beam radius decreases to its neutralized value in about 5~$\mu$s. The duration of neutralization was about 10~$\mu$s at a charging voltage $V_{FEPS}$~=~5.5~kV and 35~$\mu$s at $V_{FEPS}$~=~6.5~kV. With $V_{FEPS}$~=~6.5~kV, the transverse current density profile 33~cm downstream of the source had a Gaussian shape with $x_{rms}$=5~mm, which corresponds to a half-angle divergence of 0.87$^\circ$. The measurements show that near-perfect charge neutralization with FEPS can be attained. No loss of ion beam current was detected, indicating the absence of a neutral cloud in the region of beam propagation, which would cause beam loss to charge exchange collisions. This provides evidence in favor of using FEPS in a future Heavy Ion Fusion accelerator. The FEPS discharge was investigated based on current-voltage measurements in the pulser circuit. Different values of series resistance and storage capacitance in the pulser circuit were used. The charged particle current emitted by the FEPS into vacuum was measured from the difference in forward and return currents in the driving circuit. It was found that FEPS is an emitter of negative charge, and that electron current emission begins approximately 0.5~$\mu$s after the fast-rising high voltage pulse is applied and lasts for tens of $\mu$s. The value of the series resistance in the pulser circuit was varied to change the rise time of the voltage pulse; plasma density was expected to decrease with increasing values of resistance. However, the data showed that changing the resistance had no significant effect. The average charge emitted per shot depends strongly on the value of the storage capacitance. Lowering the capacitance from 141~nF to 47~nF resulted in a near-complete shut-off of charge emission, although the amplitude of the applied voltage pulse was as high, and rise time as short, as when high-density plasma was produced. Increasing the capacitance from 141~nF to 235~nF increased the average charge emitted per shot by a factor of$~$2.

ferroelectric plasma source↗

Beam Dynamics Study of X-Band Linac Driven X-Ray FELs

Several linac driven X-ray Free Electron Lasers (XFELs) are being developed to provide high brightness photon beams with very short, tunable wavelengths. In this paper, three XFEL configurations are proposed that achieve LCLS-like performance using X-band linac drivers. These linacs are more versatile, efficient and compact than ones using S-band or C-band rf technology. For each of the designs, the overall accelerator layout and the shaping of the bunch longitudinal phase space are described briefly.

43 PARTICLE ACCELERATORS↗

Status of the conceptual design of ALS-U

The ALS-U upgrade promises to deliver diffraction limited performance throughout the soft x-ray range by lowering the horizontal emittance to about 50 pm resulting in 2-3 orders of brightness increase for soft x-rays compared to the current ALS. The design utilizes a multi bend achromat lattice with on-axis swap-out injection and an accumulator ring. One central design goal is to install and commission ALS-U within a short dark period. This paper summarizes the status of the conceptual design of the accelerator, as well as some results of the R&D program that has been ongoing for the last 3 years.

Steier, C↗

Multistage CSR Microbunching Gain Development in Transport or Recirculation Arcs

Coherent synchrotron radiation (CSR) induced microbunching instability has been one of the most challenging issues in the design of modern accelerators. A linear Vlasov solver has been developed [1] and applied to investigate the physical processes of microbunching gain amplification for several example lattices [2]. In this paper, by further extending the concept of stage gain as proposed by Huang and Kim [3], we develop a method to characterize the microbunching development in terms of stage orders that allow the quantitative comparison of optics impacts on microbunching gain for different lattices. We find that the microbunching instability in our demonstrated arcs has a distinguishing feature of multistage amplification (e.g, up to 6th stage amplification for our example transport arcs, in contrast to two-stage amplification for a typical 4-dipole bunch compressor chicane). We also try to connect lattice optics pattern with the obtained stage gain functions by a physical interpretation. This Vlasov analysis is validated by ELEGANT [4] tracking results with excellent agreement.

Tsai, C. -Y.↗

Partial Wave Analysis of Strange Mesons Decaying to K+p+p- in the Reaction ¿p ¿ K+p+p-¿(1520) and the Commissioning of the GlueX DIRC Detector

Hadron spectroscopy is a cornerstone of our understanding of the strong nuclear interactions. Studying the hadron spectrum led to the postulation of quarks and gluons, and the development of Quantum Chromodynamics (QCD), the theory of the strong nuclear force. Today hadron spectroscopy provides an important test of QCD, particularly in the non-perturbative energy regime. One such test is the existence of hybrid hadrons that have gluonic degrees of freedom, e.g. q ?qg states, that are allowed by QCD but have remained elusive in experimental searches. The GlueX experiment located at Thomas Jefferson National Accelerator Facility, is designed to map the light meson spectrum, including hybrid mesons, produced by a linearly polarized photon beam that is scattered off of a liquid hydrogen target. This dissertation concerns the installation and commissioning of the GlueX DIRC upgrade and the analysis of three reactions measured by the GlueX experiment. The GlueX DIRC is a particle identification detector installed as an upgrade to the GlueX experiment in 2019 to improve the experiment?s ability to distinguish pions and kaons. The DIRC uses Cherenkov photons radiated by charged particles that travel faster than the speed of light in the detector medium to determine the velocity of said particles. The velocity measurement is used in conjunction with momentum measurements from other detectors to determine the mass of the particle. The DIRC will be essential to the future of strange meson spectroscopy in GlueX. The reactions ?p ? K+K??+??p, ?p ? K+K??0?0p, ?p ? K+K??0?p were initially chosen for this analysis to search for the hybrid meson candidate ?(2170) and related resonances. The ?(2170) has been observed in e+e? collider experiments decaying to K+K??+?? and K+K??0?0, among other final states. The ?(2170) was not observed in this analysis. The reaction ?p ? K+?+???(1520), a subset of the ?p ? K+K??+??p reaction, was analyzed with a Partial Wave Analysis (PWA) in order to study strange mesons that decay to K+?+??. In the PWA, a useful model for the angular distributions was found but no significant structures could be observed due to statistical limitations.

Hurley, Andrew↗

Advanced Computing Annual Report 2023

In 2023, advanced computing saw the arrival of Kestrel, the National Renewable Energy Laboratory's (NREL's) newest high-performance computing (HPC) system. Kestrel will accelerate clean energy research at a pace and scale more than five times greater than Eagle, with approximately 44 petaflops of computing power. Kestrel's heterogeneous architecture - which includes both CPU-only and GPU-accelerated nodes - is designed to bring a much greater GPU capacity to EERE workloads compared to Eagle, enabling rapidly advancing applications in artificial intelligence and expanding research in new directions for computing. In Fiscal Year (FY) 2023, 333 projects utilized NREL's HPC system, advancing the U.S. Department of Energy's (DOE's) Office of Energy Efficiency and Renewable Energy (EERE) mission across 13 funding areas. Cross-disciplinary collaboration among researchers yielded more than 800 technical outputs, including 177 peer-reviewed journal articles in FY 2023. All this great work continues to advance the science of energy efficiency and renewable energy. This report highlights research that utilized HPC resources in FY 2023.

advanced computing↗

Cost-Benefit Assessment of Additive Manufacturing for Injection Molds

This report presents an additive-manufacturing (AM) technology, where AM Cyclic Olefin Resin (COR) molds would be used for injection molding. The National Laboratory of the Rockies (NLR) team has focused on the costs and economics of this developing technology. This report presents a cost-benefit analysis of using the polySpectra AM COR molds made of COR, at the start of the project (Present') and the potential lifetime, cost-effectiveness, and performance by the end of the project period (Period 3'). The analysis of the AM COR molds is compared to traditional Computer Numerical Control (CNC) machined aluminum molds across the time periods. A cost-benefit model framework has been developed to evaluate AM COR molds. This model accounts for mold delivery to customers, current and future levels of technology readiness, the type of material injected, and various business cases. AM COR molds offer a major advantage in lead time, reducing production setup from weeks or months (with CNC machining) to as little as two to five days. This enables faster prototyping, quicker design cycles, and accelerated time-to-market, critical in industries like electronics, aerospace, medical devices, and automotive. Even modest improvements in the durability of polySpectra AM COR molds show the potential for these molds to complement traditional tooling. With further development, AM COR mold technology could provide significant time and cost savings while supporting increased domestic manufacturing capacity.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Experimental Studies of Nonlinear Integrable Optics with Elliptic Potentials

The stable transport of charged particle beams is the core challenge in designing and operating accelerators. The current paradigm for transverse focusing is based on quadrupole and dipole elements, described as a linear integrable Hamiltonian by Courant and Snyder. The operational limits of high intensity accelerators are often determined by collective instabilities within the beam. Nonlinear elements may be added to suppress certain forms of these collective effects, but restrict the range of stable trajectories. These shortcomings motivate extending to a nonlinear integrable system which can offer the benefits of suppressing collective instabilities without limiting the stable trajectories. Danilov and Nagaitsev proposed a novel nonlinear integrable system with elliptical potentials, which could be implemented as magnetic elements in an accelerator. Such a system has been implemented for practical verification in the integrable optics test accelerator (IOTA), a small storage ring constructed for beam dynamics studies. Electron beam studies in IOTA treat the low-emittance beam as a macroparticle for detailed probing of the expected single particle dynamics. This dissertation details new measurements of the nonlinear integrable system relevant for practical implementation. Turn-by-turn measurements of the kicked beam responses are used for phase space reconstruction and analysis of the predicted nonlinear dynamics. The stability and aperture for various nonlinear configurations are measured with beam losses. Amplitude dependent detuning, a core figure of merit for suppressing instabilities, is measured and compared with high fidelity particle tracking simulations. The synchrotron radiation images of circulating beam allow direct measurements of the topology and lifetime in configurations where nonlinear focusing terms dominate.

Wieland, John [Michigan U.] (ORCID:000000028971852↗

Solid Xenon Project

Crystals like Germanium and Silicon need to be grown in specialized facilities which is time and money costly. It takes many runs to test the detector once it's manufactured and mishaps are very probable. It is of a great challenge to grow big germanium crystals and that's why stacking them up in a tower is the only way at the moment to increase testing mass. Liquid Noble gas experiments experiencing contamination problems, their predicted energy resolution at 10 keV and lower energy range is not as good as predicted. Every experiment is targeting one specific purpose, looking for one thing. Why not to design an experiment that is diverse and build a detector that can search for Dark Matter, Solar Axions, Neutrinoless Double Beta decay, etc. Solid Xenon detector is such detector. We designed a simple Xenon crystal growing chamber that was put together at Fermi National Accelerator Laboratory. The first phase of this experiment was to demonstrate that a good, crack free Xenon crystal can be grown (regardless of many failed attempts by various groups) and our first goal, 1 kg crystal, was successful.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concept em design of the 650 MHz cavities for the Project X

Concept of the 650 MHz cavities for the Project X is presented. Choice of the basic parameters, i.e., number of cells, geometrical {beta}, apertures, coupling coefficients, etc., is discussed. The cavity optimization criteria are formulated. Results of the RF design are presented for the cavities of both the low-energy and high-energy sections.

43 PARTICLE ACCELERATORS↗

Lessons Learned From The 200 West Pump And Treatment Facility Construction Project At The US DOE Hanford Site - A Leadership For Energy And Environmental Design (LEED) Gold-Certified Facility

CH2M Hill Plateau Remediation Company (CHPRC) designed, constructed, commissioned, and began operation of the largest groundwater pump and treatment facility in the U.S. Department of Energy&#x27;s (DOE) nationwide complex. This one-of-a-kind groundwater pump and treatment facility, located at the Hanford Nuclear Reservation Site (Hanford Site) in Washington State, was built in an accelerated manner with American Recovery and Reinvestment Act (ARRA) funds and has attained Leadership in Energy and Environmental Design (LEED) GOLD certification, which makes it the first non-administrative building in the DOE Office of Environmental Management complex to earn such an award. There were many contractual, technical, configuration management, quality, safety, and LEED challenges associated with the design, procurement, construction, and commissioning of this $95 million, 52,000 ft groundwater pump and treatment facility. This paper will present the Project and LEED accomplishments, as well as Lessons Learned by CHPRC when additional ARRA funds were used to accelerate design, procurement, construction, and commissioning of the 200 West Groundwater Pump and Treatment (2W P&T) Facility to meet DOE&#x27;s mission of treating contaminated groundwater at the Hanford Site with a new facility by June 28, 2012.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Zero Degree Line Mo Target Thermal Test Results and Analysis

Target testing at 35 and 42 MeV was completed on January 14, 2015. At 35 MeV the current was varied from 177 to 375 μA with helium mass flow rate varied from 45 up to 101 g/s. At 42 MeV only one current, 170 mA, was tested because of accelerator performance limitations. The target design for this test, and the subsequent production tests, is largely unchanged from the earlier design for ANL beam tests at lower energy and higher current, comprised of 25 Mo disks 1 mm thick spaced 0.5 mm apart for helium coolant flow gaps. Disks are 12 mm diameter, with expected beam size 6 mm FWHM. Because the target, particularly the window, was designed for lower energy and higher current, the intercepted beam (beam heating) was much less during these tests. Therefore, the thermal stress and, more importantly, reduction in material strength resulting from high temperature, was not a limiting concern. The intended result of the thermal test is to measure heat transfer as a function of helium mass flow rate. Heat transfer coefficient was determined by the measurement of temperature at the center of the first 8 Mo disks while varying helium flow rate and beam current. The performance was then compared to predictive tools: Heat transfer correlations in the literature and finite element analysis using ANSYS

42 ENGINEERING↗

Memorandum of Understanding for the 2010-2011 Meson Test Beam Program T-994: JASMIN in the Meson Test Beam

This is a memorandum of understanding between the Fermi National Accelerator Laboratory (Fermilab) and Japan Atomic Energy Agency (JAEA) experimenters who have committed to participate in beam tests to be carried out during the 2010-2011 Meson Test Beam Facility program. The memorandum is intended solely for the purpose of providing a budget estimate and a work allocation for Fermi1ab, the funding agencies and the participating institutions. It reflects an arrangement that currently is satisfactory to the parties; however, it is recognized and anticipated that changing circumstances of the evolving research program will necessitate revisions. The parties agree to negotiate the appropriate amendments to this memorandum if adjustments are required. The experimenters require beam time at Fermilab during the 2010-2011 Meson Test Beam Run to perform a precise measurement of secondary particles and activation of materials irradiated by high energy particles. This measurement will provide basic data for radiation safety design of high energy accelerators. The data will be used for validation of high energy multi-particle transport codes that are widely used for radiation safety design at high energy accelerators. The JASMIN Collaboration has already performed measurements of activation and secondary particles at the pbar vault and NuMI alcoves at Fermilab. The groups from JAEA and Fermilab have been supported by grant-aid of the Ministry of Education Science and Culture in Japan to perform data taking at the Fermilab Meson Test Beam Facility. The continued experiments at the pbar vault and NuMI alcoves after April 2009 are outlined in a separate MOU T993. The new measurements using the Meson Test Beam Facility (MTest) have as their purpose to obtain basic nuclear data and to develop instrumental techniques for characterization of particle fields of protons, neutrons, muons, etc. The data taken at MTest, in contrast to the data taken at pbar and NuMI, play an important role to the check validity of secondary particle generation models without the effect from attenuation.

43 PARTICLE ACCELERATORS↗

MRI Guidance for Accelerated Partial Breast Irradiation in Prone Position: Imaging Protocol Design and Evaluation

Purpose: To design and evaluate a magnetic resonance imaging (MRI) protocol to be incorporated in the simulation process for external beam accelerated partial breast irradiation. Methods and Materials: An imaging protocol was developed based on an existing breast MRI technique with the patient in the prone position on a dedicated coil. Pulse sequences were customized to exploit T1 and T2 contrast mechanisms characteristic of lumpectomy cavities. A three-dimensional image warping algorithm was included to correct for geometric distortions related to nonlinearity of spatially encoding gradients. Respiratory motion, image distortions, and susceptibility artifacts of 3.5-mm titanium surgical clips were examined. Magnetic resonance images of volunteers were acquired repeatedly to analyze residual setup deviations resulting from breast tissue deformation. Results: The customized sequences generated high-resolution magnetic resonance images emphasizing lumpectomy cavity morphology. Respiratory motion was negligible with the subject in the prone position. The gradient-induced nonlinearity was reduced to less than 1 mm in a region 15 cm away from the isocenter of the magnet. Signal-void regions of surgical clips were 4 mm and 8 mm for spin echo and gradient echo images, respectively. Typical residual repositioning errors resulting from breast deformation were estimated to be 3 mm or less. Conclusions: MRI guidance for accelerated partial breast irradiation with the patient in the prone position with adequate contrast, spatial fidelity, and resolution is possible.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design of a Plasma Injector for a Pulsed Plasma Accelerator

In recent years, a pulsed plasma accelerator has been proposed as a candidate stand-off driver for the formation of an imploding liner in magnetized target fusion. For a near-term physics exploratory experiment to study the feasibility of this standoff approach, a plasma accelerator has been proposed that requires the controlled introduction and preparation of the initial plasma for acceleration. This includes uniform injection of the propellant downstream of the breech with a high degree of ionization. The design of a plasma feed is presented, which injects a high conductivity, highly collisional propellant transverse to the conductor. The plasma injector is designed to establish an initial plasma with a moderate Hall parameter at the trailing edge of the plasma slug, high Hall parameter behind the slug for magnetic insulation, and a short diffusion length in comparison with characteristic dimensions of the plasma slug to avoid propellant loss at the trailing edge.

Cassibry, J. T.↗

TU-H-BRA-02: The Physics of Magnetic Field Isolation in a Novel Compact Linear Accelerator Based MRI-Guided Radiation Therapy System

Purpose: To develop a method for isolating the MRI magnetic field from field-sensitive linear accelerator components at distances close to isocenter. Methods: A MRI-guided radiation therapy system has been designed that integrates a linear accelerator with simultaneous MR imaging. In order to accomplish this, the magnetron, port circulator, radiofrequency waveguide, gun driver, and linear accelerator needed to be placed in locations with low magnetic fields. The system was also required to be compact, so moving these components far from the main magnetic field and isocenter was not an option. The magnetic field sensitive components (exclusive of the waveguide) were placed in coaxial steel sleeves that were electrically and mechanically isolated and whose thickness and placement were optimized using E&M modeling software. Six sets of sleeves were placed 60° apart, 85 cm from isocenter. The Faraday effect occurs when the direction of propagation is parallel to the magnetic RF field component, rotating the RF polarization, subsequently diminishing RF power. The Faraday effect was avoided by orienting the waveguides such that the magnetic field RF component was parallel to the magnetic field. Results: The magnetic field within the shields was measured to be less than 40 Gauss, significantly below the amount needed for the magnetron and port circulator. Additional mu-metal was employed to reduce the magnetic field at the linear accelerator to less than 1 Gauss. The orientation of the RF waveguides allowed the RT transport with minimal loss and reflection. Conclusion: One of the major challenges in designing a compact linear accelerator based MRI-guided radiation therapy system, that of creating low magnetic field environments for the magnetic-field sensitive components, has been solved. The measured magnetic fields are sufficiently small to enable system integration. This work supported by ViewRay, Inc.

60 APPLIED LIFE SCIENCES↗

Two-element Zeeman slower for rubidium and lithium

We demonstrate a two-element oven and Zeeman slower that produce simultaneous and overlapped slow beams of rubidium and lithium. The slower uses a three-stage design with a long, low-acceleration middle stage for decelerating rubidium situated between two short, high-acceleration stages for aggressive deceleration of lithium. This design is appropriate for producing high fluxes of atoms with a large mass ratio in a simple, robust setup.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Transverse Linac Optics Design in Multi-pass ERL

In this paper, we analyzed the linac optics design requirement for a multi-pass energy recovery linac (ERL) for arbitrary number of linacs. A set of general formula of constrains for the 2-D transverse matrix is derived to ensure design optics acceptance matching throughout the entire accelerating and decelerating process. Meanwhile, the rest free parameters can be adjusted for fulfilling other requirements or optimization purpose. As an example, we design the linac optics for the future MeRHIC (Medium Energy eRHIC) project and show the optimization for small {beta} function.

43 PARTICLE ACCELERATORS↗