Direct methane utilization through benzene dehydroalkylation catalyzed by Co2+ sites in ZSM-5 intersections
Not Available
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
In low-temperature CO 2 electrolysis, a fundamental trade-off exists between maximizing electrolyzer performance and minimizing downstream CO 2 recovery. Here, by coupling a down-the-gas-channel electrolyzer model with a techno-economic analysis, we find that the optimal single-pass CO 2 conversion for ethylene production is typically low—on the order of 5%–10%—although larger optima are found if the H 2 faradic efficiency is very low. Similarly, strategies for eliminating carbonate crossover require more energy than downstream gas separation if they increase the cell potential by ~0.2 V; however, when CAPEX are accounted for, this “break-even” voltage increases to ~ 0.4 to 0.8 V for electricity prices varying from 6c/kWh to 1.5c/kWh. These findings are a consequence of the low energy requirements of industrial gas separation relative to electrochemical CO 2 reduction. Under most circumstances, maintaining near-optimal electrolyzer performance is more important than reducing or eliminating downstream gas separations.
N/A
As classic treatises make clear, determining a reasonable return on equity is a judgment call, one that reflect the regulator's broad perspective on public policy matters. That requires one to look beyond economic concepts, such as cost of equity, to find the proper return. (author)
Treat the creation of a robust business continuity planning program, its continuous improvement, and the ongoing activities that support preparedness as an exercise in change management. Obtain executive sponsorship, use it only to initiate dialogue, and then seek to engage the entire workforce. (author)
Section 203 of the Federal Power Act remains subject to considerable uncertainty. Therefore, it is important to keep several rules in mind. Each potential acquisition must be separately analyzed under Section 203(a)(1) and 203(a)(2) of the Act. A proposed acquisition that is exempt or preapproved under one provision may still require prior FERC approval under the other one. (author)
Economic regulation began when much about retail electricity service was unknown. It supported a rapid evolution of technology, business models, and customers. Now, when much is unknown about the technology, business models, and customers of the future, economic regulation can serve this role again. Doing so requires only that we decide what to keep. (author)
Maine PUC and Morgan Stanley have resolved some of the key issues facing the energy industry. The Supreme Court has plainly and directly in both cases reaffirmed the central role that private contracts play in the energy industry and set terms to balance the need to secure long-term investment with the public interest that lies at the heart of the Federal Power Act. (author)
Not Available
Not Available
Not Available
Not Available
Most electricity in the world is conventionally generated using coal, oil, natural gas, nuclear energy, or hydropower. Due to environmental concerns, there is a growing interest in alternative energy sources for heat and electricity production. The major by-products obtained from coal combustion are fly ash, bottom ash, boiler slag, and flue gas desulfurization (FGD) materials. The solid wastes produced in coal-fired power plants create problems for both power-generating industries and environmentalists. The coal fly ash and bottom ash samples may be used as cementitious materials.
Desalination technologies and industry have advanced significantly in the past two decades to meet the growing freshwater demands stimulated by the compounding issues of both water quality and quantity in many regions of the world. As desalination processes are energy demanding, there have been many efforts dedicated to improve energy-efficiency of the process units, enhance energy conservation and recovery, and increase renewable energy integration in desalination plants. This review article highlights recent key advances and discusses possible venues for further development in desalination energy portfolio to reduce specific energy consumption and, via integration with solar energy, to minimize the environmental footprint associated with freshwater production. First, an overview of current desalination technologies and their energy requirements are presented followed by a discussion on opportunities for improving energy efficiency and energy recovery in both membrane and thermal desalination technologies. Then, various combinations of renewable energy driven desalination plants are discussed with some recent highlights in solar energy driven membrane, thermal and hybrid desalination processes. Technological readiness levels for novel desalination processes, their perceived impact and expected near-future developments in renewable energy integrated desalination technologies are presented. Lastly, the potential for solar driven desalination as a cost-competitive freshwater supply alternative is discussed
As microgrids transition away from use of conventional generating resources and increasingly rely on renewable resources towards decarbonization goals, it is crucial to evaluate the capability inverter-based resources to provide microgrid stability and resilience. Particularly, microgrids with a high contribution of intermittent solar photo voltaic generation and higher load variability present unique challenges requiring fast voltage and frequency support. At the San Diego Gas & Electric Company(R) (SDG&E(R)) Borrego Springs Microgrid, a battery inverter was upgraded with grid-forming (GFM) capability to serve as island leader, transitioning responsibility away from diesel generators. An interoperable microgrid control scheme was developed, coordinating GFM and grid-following (GFL) inverters. Hardware-in-the-loop (HIL) simulations using relevant power and controller HIL interfaces between real-time simulators and field equipment are being conducted to de-risk field deployment.
This paper presents the preliminary results and findings of the four operational Floating PV systems across the USA. At each site, temperature of five PV modules located at North-West, North-East, Middle, South-West, and, South-East have been monitored through the Resistant Temperature Detector (RTD) sensors. Three RTDs were attached to each PV module on the rear-side along the diagonal at top, middle and bottom cells. The preliminary results reveal wide temperature differences among the inter and intra PV modules. Besides this, wave pattern temperatures were observed in a few PV modules. The final results, findings, and, factors responsible will be investigated during the next few months.
Each year, more than 20% of electricity generated in the United States is consumed for meeting the thermal demands (e.g., space cooling, space heating, and water heating) in residential and commercial buildings. Integrating thermal energy storage (TES) with building’s HVAC systems has the potential to reshape the electric load profile of the building and mitigate the mismatch between the renewable generation and the demand of buildings. A novel ground source heat pump (GSHP) system integrated with underground thermal energy storage (UTES) has been proposed to level the electric demand of buildings while still satisfying their thermal demands. This study assessed the potential impacts of the proposed system with a bottom-up approach. The impacts on the electricity demand in various electricity markets were quantified. The results show that, within the capacity of the existing electric grids, the maximum penetration rate of the proposed system in different wholesale markets could range from 51% to 100%. Altogether, about 46 million single-family detached houses can be retrofitted into the proposed system without increasing the annual peak demand of the corresponding markets. By implementing the proposed system at its maximum penetration rate, the grid-level summer peak demand can be reduced by 9.1% to 18.2%. Meanwhile, at the grid level, the annual electricity consumption would change by –12% to 2%. The nationwide total electricity consumption would be reduced by 9%.
Differentiating between energy-efficient and inefficient single-family homes on a community scale helps identify and prioritize candidates for energy-efficiency upgrades. Prescreening diagnostic procedures can further retrofit efforts by providing efficiency information before a site-visit is conducted. We applied the prescreening diagnostic to a simulated community of homes in Boulder, Colorado and analyzed energy consumption data to identify energy-inefficient homes.