Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Application of Probability Methods to Assess Crash Modeling Uncertainty

Full-scale aircraft crash simulations performed with nonlinear, transient dynamic, finite element codes can incorporate structural complexities such as: geometrically accurate models; human occupant models; and advanced material models to include nonlinear stress-strain behaviors, and material failure. Validation of these crash simulations is difficult due to a lack of sufficient information to adequately determine the uncertainty in the experimental data and the appropriateness of modeling assumptions. This paper evaluates probabilistic approaches to quantify the effects of finite element modeling assumptions on the predicted responses. The vertical drop test of a Fokker F28 fuselage section will be the focus of this paper. The results of a probabilistic analysis using finite element simulations will be compared with experimental data.

Lyle, Karen H.↗

Heat Transfer in Conical Corner and Short Superelliptical Transition Ducts

Local surface heat transfer measurements were experimentally mapped using a transient liquid-crystal heat-transfer technique on the surface of two circular-to-rectangular transition ducts. One has a transition cross section defined by conical corners (Duct 1) and the other by an elliptical equation with changing coefficients (Duct 2). Duct 1 has a length-to-diameter ratio of 0.75 and an exit plane aspect ratio of 1.5. Duct 2 has a length-to-diameter ratio of 1.0 and an exit plane aspect ratio of 2.9. Test results are reported for various inlet-diameter-based Reynolds numbers ranging from 0.45 106 to 2.39 106 and two freestream turbulence intensities of about 1 percent, which is typical of wind tunnels, and up to 16 percent, which may be more typical of real engine conditions.

Poinsatte, Philip↗

Evaluation of Ferrite Chip Beads as Surge Current Limiters in Circuits with Tantalum Capacitors

Limiting resistors are currently required to be connected in series with tantalum capacitors to reduce the risk of surge current failures. However, application of limiting resistors decreases substantially the efficiency of the power supply systems. An ideal surge current limiting device should have a negligible resistance for DC currents and high resistance at frequencies corresponding to transients in tantalum capacitors. This work evaluates the possibility of using chip ferrite beads (FB) as such devices. Twelve types of small size FBs from three manufacturers were used to evaluate their robustness under soldering stresses and at high surge current spikes associated with transients in tantalum capacitors. Results show that FBs are capable to withstand current pulses that are substantially greater than the specified current limits. However, due to a sharp decrease of impedance with current, FBs do not reduce surge currents to the required level that can be achieved with regular resistors.

surge current testing↗

Langley facility for tests at Mach 7 of subscale, hydrogen-burning, airframe-integratable, scramjet models

Modifications to a 20-megawatt arc-heated facility for testing a hydrogen-burning, airframe-integratable, subscale, scramjet model are described. Arc-heated flow is mixed with unheated air to furnish a test flow duplicating Mach 7 flight. (Stagnation temperature is 2220 K.) Modifications to the commercially available heater to improve survivability and smoothness are described. Pitot profiles show uniform flow and a slightly thinner nozzle boundary layer than predicted. Comparison of the tunnel boundary layer, which will be ingested by the engine model, with the boundary layer that a flight engine might ingest from its vehicle forebody shows a difference in the density distribution through the boundary layer. Calculations of wall heating and transient wall temperatures of the engine model show that for a 30-sec burn, the heat sink model requires cooling at selected locations to avoid thermal-stress, cycle-life problems. Model performance predictions show that fuel equivalence ratio and nozzle exit area both have large effects on thrust. Average inlet entrance Mach number (as affected by boundary-layer ingestion) has little effect on thrust.

Boatright, W. B.↗

Problems and solutions for transition detection in cryogenic wind tunnels by infrared imaging

The authors analyzed the problems associated with the detection of boundary-layer transition to turbulence by using the IR imaging techique in cryogenic wind-tunnel testing. It is shown that testing at low temperatures forces this implementation to run against the physical laws of diminishing returns. The most difficult obstacle resulted from the considerable decrease in the overall level of IR radiation and the parallel shift of the bulk of the radiated energy to longer wavelengths, beyond 30 microns at 100 K. Some measures to alleviate the problem are described. The thermal signature of transition can be enhanced by allowing the flow in the wind tunnel to heat incrementally, thus inducing a transient heat transfer to the model. As a result, the model area under the turbulent regime is revealed by its higher heating rate compared to the laminar regime.

Gartenberg, Ehud↗

Summary: Experimental validation of real-time fault-tolerant systems

Testing and validation of real-time systems is always difficult to perform since neither the error generation process nor the fault propagation problem is easy to comprehend. There is no better substitute to results based on actual measurements and experimentation. Such results are essential for developing a rational basis for evaluation and validation of real-time systems. However, with physical experimentation, controllability and observability are limited to external instrumentation that can be hooked-up to the system under test. And this process is quite a difficult, if not impossible, task for a complex system. Also, to set up such experiments for measurements, physical hardware must exist. On the other hand, a simulation approach allows flexibility that is unequaled by any other existing method for system evaluation. A simulation methodology for system evaluation was successfully developed and implemented and the environment was demonstrated using existing real-time avionic systems. The research was oriented toward evaluating the impact of permanent and transient faults in aircraft control computers. Results were obtained for the Bendix BDX 930 system and Hamilton Standard EEC131 jet engine controller. The studies showed that simulated fault injection is valuable, in the design stage, to evaluate the susceptibility of computing sytems to different types of failures.

Iyer, R. K.↗

Simulation of Aircraft Landing Gears with a Nonlinear Dynamic Finite Element Code

Recent advances in computational speed have made aircraft and spacecraft crash simulations using an explicit, nonlinear, transient-dynamic, finite element analysis code more feasible. This paper describes the development of a simple landing gear model, which accurately simulates the energy absorbed by the gear without adding substantial complexity to the model. For a crash model, the landing gear response is approximated with a spring where the force applied to the fuselage is computed in a user-written subroutine. Helicopter crash simulations using this approach are compared with previously acquired experimental data from a full-scale crash test of a composite helicopter.

Lyle, Karen H.↗

Capillary Flow in Containers of Polygonal Section: Theory and Experiment

An improved understanding of the large-length-scale capillary flows arising in a low-gravity environment is critical to that engineering community concerned with the design and analysis of spacecraft fluids management systems. Because a significant portion of liquid behavior in spacecraft is capillary dominated it is natural to consider designs that best exploit the spontaneous character of such flows. In the present work, a recently verified asymptotic analysis is extended to approximate spontaneous capillary flows in a large class of cylindrical containers of irregular polygonal section experiencing a step reduction in gravitational acceleration. Drop tower tests are conducted using partially-filled irregular triangular containers for comparison with the theoretical predictions. The degree to which the experimental data agree with the theory is a testament to the robustness of the basic analytical assumption of predominantly parallel flow. As a result, the closed form analytical expressions presented serve as simple, accurate tools for predicting bulk flow characteristics essential to practical low-g system design and analysis. Equations for predicting corner wetting rates, total container flow rates, and transient surfaces shapes are provided that are relevant also to terrestrial applications such as capillary flow in porous media.

Weislogel, Mark M.↗

Vestibular and Non-vestibular Contributions to Eye Movements that Compensate for Head Rotations during Viewing of Near Targets

We studied horizontal eye movements induced by en-bloc yaw rotation, over a frequency range 0.2 - 2.8 Hz, in 10 normal human subjects as th ey monocularly viewed a target located at their near point of focus. We measured gain and phase relationships between eye-in-head velocity and head velocity when the near target was either earth-fixed or head-fixed. During viewing of the earth-fixed near target,median gain was 1.49 (range 1.24 - 1.87) at 0.2 Hz for the group of subjects, but decl ined at higher frequencies, so that at 2.8 Hz median gain was 1.08 (r ange 0.68 - 1.67). During viewing of the head-fixed near target, median gain was 0.03 (range 0.01 - 0.10) at 0.2 Hz for the group of subjec ts, but increased at higher frequencies, so that at 2.8 Hz median gai n was 0.71 (range 0.28 - 0.94). We estimated the vestibular contribution to these responses (vestibulo-ocular reflex gain, Gvor) by applyin g transient head perturbations (peak acceleration> 1,000 deg's(exp 2) ) during sinusoidal rotation under the two viewing conditions. Median Gvor, estimated < 70m after the onset of head perturbation, was 0.98 (range 0.39 - 1.42) while viewing the earth-fixed near target, and 0. 97 (range 0.37 - 1.33) while viewing the head-fixed near target. For the group of subjects, 9 out of 10 subjects showed no sigificant diff erence of Gvor between the two viewing conditions ( p > 0.053 ) at all test frequencies. Since Gvor accounted for only approximately 73% of the overall response gain during viewing of the earth-fixed target, we investigated the relative contributions of non-vestibular factors. When subjects viewed the earth-fixed target under strobe illumination , to eliminate retinal image slip information, the gain of compensato ry eye movements declined compared with viewing in ambient room light . During sum-of-sine head rotations, while viewing the earth-fixed target, to minimize contributions from predictive mechanisms, gain also declined Nonetheless, simple superposition of smooth-pursuit tracking of sinusoidal target motion could not fully account for the overall r esponse at higher frequencies, suggesting other non-vestibular contributions. During binocular viewing conditions when vergence angle was s ignificantly greater than monocular viewing (p < 0.001), this gain of compensatory eye movements did not show proportional change; indeed, gain could not be correlated with vergence angle during monocular or binocular viewing. We conclude that several separate factors contribute to generate eye rotations during sinusoidal yaw head rotations whi le viewing a near target; these include the VOR, visual-tracking eye movements that utilize retinal image motion, predictive eye movements and, possibly, other unidentified nonvestibular factors. For these experiments, vergence was not an important determinant of response gain .

Han, Yanning H.↗

Macro Scale Independently Homogenized Subcells for Modeling Braided Composites

An analytical method has been developed to analyze the impact response of triaxially braided carbon fiber composites, including the penetration velocity and impact damage patterns. In the analytical model, the triaxial braid architecture is simulated by using four parallel shell elements, each of which is modeled as a laminated composite. Currently, each shell element is considered to be a smeared homogeneous material. The commercial transient dynamic finite element code LS-DYNA is used to conduct the simulations, and a continuum damage mechanics model internal to LS-DYNA is used as the material constitutive model. To determine the stiffness and strength properties required for the constitutive model, a top-down approach for determining the strength properties is merged with a bottom-up approach for determining the stiffness properties. The top-down portion uses global strengths obtained from macro-scale coupon level testing to characterize the material strengths for each subcell. The bottom-up portion uses micro-scale fiber and matrix stiffness properties to characterize the material stiffness for each subcell. Simulations of quasi-static coupon level tests for several representative composites are conducted along with impact simulations.

Blinzler, Brina J.↗

Interplanetary Space Weather Effects on Lunar Reconnaissance Orbiter Avalanche Photodiode Performance

Space weather is a major concern for radiation-sensitive space systems, particularly for interplanetary missions, which operate outside of the protection of Earth's magnetic field. We examine and quantify the effects of space weather on silicon avalanche photodiodes (SiAPDs), which are used for interplanetary laser altimeters and communications systems and can be sensitive to even low levels of radiation (less than 50 cGy). While ground-based radiation testing has been performed on avalanche photodiode (APDs) for space missions, in-space measurements of SiAPD response to interplanetary space weather have not been previously reported. We compare noise data from the Lunar Reconnaissance Orbiter (LRO) Lunar Orbiter Laser Altimeter (LOLA) SiAPDs with radiation measurements from the onboard Cosmic Ray Telescope for the Effects of Radiation (CRaTER) instrument. We did not find any evidence to support radiation as the cause of changes in detector threshold voltage during radiation storms, both for transient detector noise and long-term average detector noise, suggesting that the approximately 1.3 cm thick shielding (a combination of titanium and beryllium) of the LOLA detectors is sufficient for SiAPDs on interplanetary missions with radiation environments similar to what the LRO experienced (559 cGy of radiation over 4 years).

LOLA↗

Densification of Liquid Oxygen – A Comparison of Numerical and Experimental Results

The NASA Launch Services Program and the NASA Engineering Safety Center had a requirement to conduct large scale tests with densified liquid oxygen. A densification system was designed where two dewars were simultaneously filled with liquid oxygen and pumped down with an ejector using nitrogen as the motive gas to densify the liquid. The dewars were evacuated to a final pressure of 5.86 kPa. The temperature of the liquid was not measured. Three distinct numerical models were created and compared against the experimental results. While these models were able to predict the final pump down time to within 15%, the transient behavior agrees with the experimental results within 30%. The final predicted temperature could not be verified as this was not measured during the experiment.

J Sasson↗

Transient performance of fan engine with water ingestion

In a continuing investigation on effects of rain-water ingestion into bypass fan engines, it is shown that the performance of axial-flow compressors and fans is fundamentally time-dependent during ingestion of water. A code named WINCOF-I has been developed for establishing the performance of axial-flow turbomachinery operating with air-water vapor-water droplet-water film mixture, Illustrative examples of predictions and effects are provided for the case of the air-compression system of a generic bypass fan engine. Utilizing performance maps so-generated, the effects of water ingestion into the generic engine have been determined under test cell conditions simulating ingestion, flight operation (altitude and flight Mach number), and power-demand setting.

Murthy, S. N. B.↗

G-189A analytical simulation of the integrated waste management-water system using radioisotopes for thermal energy

An analytical simulation of the RITE-Integrated Waste Management and Water Recovery System using radioisotopes for thermal energy was prepared for the NASA-Manned Space Flight Center (MSFC). The RITE system is the most advanced concept water-waste management system currently under development and has undergone extended duration testing. It has the capability of disposing of nearly all spacecraft wastes including feces and trash and of recovering water from usual waste water sources: urine, condensate, wash water, etc. All of the process heat normally used in the system is produced from low penalty radioisotope heat sources. The analytical simulation was developed with the G189A computer program. The objective of the simulation was to obtain an analytical simulation which can be used to (1) evaluate the current RITE system steady state and transient performance during normal operating conditions, and also during off normal operating conditions including failure modes; and (2) evaluate the effects of variations in component design parameters and vehicle interface parameters on system performance.

Coggi, J. V.↗

An improved high power hybrid capillary pumped loop

In order to improve performance testing, NASA's High-Power Spacecraft Thermal Management system has been modified through (1) an augmentation of heat-dissipation capacity of the condenser sink for steady-state high power operation, (2) the addition of more pressure transducers for pressure-drop monitoring in various system components, (3) the installation of pressure-contact thermocouples on the evaporators to measure heating surface temperature, (4) the provision of a coolant loop to one of the evaporator plates, (5) the placing of a transient fluid flow-monitoring load cell in the reservoir, and (6) the reorientation of the reservoir to reduce compressed vapor effects. The system is now capable of 10 hours of continuous capillary mode operation at an input power level of 20 kW.

Ku, Jentung↗

Heavy ion induced Single Event Phenomena (SEP) data for semiconductor devices from engineering testing

The accumulation of JPL data on Single Event Phenomena (SEP), from 1979 to August 1986, is presented in full report format. It is expected that every two years a supplement report will be issued for the follow-on period. This data for 135 devices expands on the abbreviated test data presented as part of Refs. (1) and (3) by including figures of Single Event Upset (SEU) cross sections as a function of beam Linear Energy Transfer (LET) when available. It also includes some of the data complied in the JPL computer in RADATA and the SPACERAD data bank. This volume encompasses bipolar and MOS (CMOS and MHNOS) device data as two broad categories for both upsets (bit-flips) and latchup. It also includes comments on less well known phenomena, such as transient upsets and permanent damage modes.

Nichols, Donald K.↗

An adaptive grid algorithm for one-dimensional nonlinear equations

Richards' equation, which models the flow of liquid through unsaturated porous media, is highly nonlinear and difficult to solve. Step gradients in the field variables require the use of fine grids and small time step sizes. The numerical instabilities caused by the nonlinearities often require the use of iterative methods such as Picard or Newton interation. These difficulties result in large CPU requirements in solving Richards equation. With this in mind, adaptive and multigrid methods are investigated for use with nonlinear equations such as Richards' equation. Attention is focused on one-dimensional transient problems. To investigate the use of multigrid and adaptive grid methods, a series of problems are studied. First, a multigrid program is developed and used to solve an ordinary differential equation, demonstrating the efficiency with which low and high frequency errors are smoothed out. The multigrid algorithm and an adaptive grid algorithm is used to solve one-dimensional transient partial differential equations, such as the diffusive and convective-diffusion equations. The performance of these programs are compared to that of the Gauss-Seidel and tridiagonal methods. The adaptive and multigrid schemes outperformed the Gauss-Seidel algorithm, but were not as fast as the tridiagonal method. The adaptive grid scheme solved the problems slightly faster than the multigrid method. To solve nonlinear problems, Picard iterations are introduced into the adaptive grid and tridiagonal methods. Burgers' equation is used as a test problem for the two algorithms. Both methods obtain solutions of comparable accuracy for similar time increments. For the Burgers' equation, the adaptive grid method finds the solution approximately three times faster than the tridiagonal method. Finally, both schemes are used to solve the water content formulation of the Richards' equation. For this problem, the adaptive grid method obtains a more accurate solution in fewer work units and less computation time than required by the tridiagonal method. The performance of the adaptive grid method tends to degrade as the solution process proceeds in time, but still remains faster than the tridiagonal scheme.

Gutierrez, William E.↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

Ku, Jentung↗