At least 1,693 records · Page 94

Pyrotechnic shock measurement and data analysis requirements

A study of laboratory measurement and analysis of pyrotechnic shock prompted by a discrepancy in preliminary Mariner Jupiter/Saturn shock test data is reported. It is shown that before generating shock response plots from any recorded pyrotechnic event, a complete review of each instrumentation and analysis system must be made. In addition, the frequency response capability of the tape recorder used should be as high as possible; the discrepancies in the above data were due to inadequate frequency response in the FM tape recorders. The slew rate of all conditioning amplifiers and input converters must be high enough to prevent signal distortion at maximum input voltage; amplifier ranges should be selected so that the input pulse is approximately 50% of full scale; the Bessel response type should be chosen for digital shock analysis if antialiasing filters are employed; and transducer selection must consider maximum acceleration limit, mounted resonance frequency, flat clean mounting surfaces, base bending sensitivity, and proper torque.

Albers, L.↗

Viking 1975 Orbiter Development Test Model/Lander Dynamic Test Model dynamic environmental testing - An overview

The current work presents an overview of the Viking 1975 environmental testing from an engineering standpoint. An extremely large vibration test fixture had to be designed, analyzed, and integrated into a test setup that employed hydrostatic bearings in a new fashion. A vibration control system was also required that would allow for thirty-six channels of sine-wave peak select control from acceleration, force-of-strain transducers. In addition, some 68 channels of peak limiting shutdown capability were needed for backup and monitoring of other data during the forced vibration test. Pretesting included analyses of the fixture design, overturning moment, control system capabilities, and response of the entire spacecraft/fixture/exciter system to the test environment. Closed-loop control for acoustic testing was a necessity due to the fact that the Viking spacecraft took up a major portion of the volume of the 10,000 cu ft chamber. The spacecraft emerged from testing undamaged.

Milder, G.↗

Electro-optical liquid depth sensor

Transducer utilizes absorptive properties of water to determine variations in depth without disturbing liquid. Instrument is inexpensive, simple, and small and thus can be used in lieu of direct graduated scale readout or capacitive, ultrasonic, resistive or inducive sensors when these are impractical because of complexity or cost.

Heppner, D. B.↗

Improved interferometer beam splitter

Cat's-eye retroreflector attached to motor driven lead screw allows low-frequency changes in optical path. Moving-coil actuator attached to other retroreflector allows mid-frequency movements. High-frequency movements are achieved by employing piezoelectric transducer attached to secondary mirror of same retroreflector.

Schindler, R. A.↗

Ultrasonic monitoring of crack extension

System consisting of commerical ultrasonic flaw detector with transducer clamped to specimen and x-yy' recorder provides permanent record of crack extension, resulting in clear indication of onset of cracking that is relatively insensitive to plastic deformation.

Kliman, S. J.↗

Noise addendum experimental clean combustor program, phase 1

The development of advanced CTOL aircraft engines with reduced exhaust emissions is discussed. Combustor noise information provided during the basic emissions program and used to advantage in securing reduced levels of combustion noise is included. Results are presented of internal pressure transducer measurements made during the scheduled emissions test program on ten configurations involving variations of three basic combustor designs.

Sofrin, T. G.↗

Use of a pitot probe for determining wing section drag in flight

A wake traversing probe was used to obtain section drag and wake profile data from the wing of a sailplane. The transducer sensed total pressure defect in the wake as well as freestream total pressure on both sides of the sensing element when the probe moved beyond the wake. Profiles of wake total pressure defects plotted as a function of distance above and below the trailing edge plane were averaged for calculating section drag coefficients for flights at low dynamic pressures.

Saltzman, E. J.↗

Mechanical test in-situ fracture device for Auger electron spectroscopy

An in-situ fracture device for Auger spectroscopy was described. The device is designed to handle small tensile specimens or small double cantilever beam specimens and is fully instrumented with load and displacement transducers so that quantitative stress-strain measurements can be made directly. Some initial test results for specimens made from 4130 and 1020 steel were presented.

Moorhead, R. D.↗

Amplification of Reynolds number dependent processes by wave distortion

A system using a hot-wire transducer as an analog of a liquid droplet of propellant was employed to investigate the ingredients of the acoustic instability of liquid-propellant rocket engines. It was assumed that the combustion process was vaporization-limited and that the combustion chamber was acoustically similar to a closed-closed right-circular cylinder. Before studying the hot-wire closed-loop system (the analog system), a microphone closed-loop system, which used the response of a microphone as the source of a linear feedback exciting signal, was investigated to establish the characteristics of self-sustenance of acoustic fields. Self-sustained acoustic fields were found to occur only at resonant frequencies of the chamber. In the hot-wire closed-loop system, the response of hot-wire anemometer was used as the source of the feedback exciting signal. The self-sustained acoustic fields which developed in the system were always found to be harmonically distorted and to have as their fundamental frquency a resonant frequency for which there also existed a second resonant frequency which was approximately twice the fundamental frequency.

Ventrice, M. B.↗

Description of a landing site indicator (LASI) for light aircraft operation

An experimental cockpit mounted head-up type display system was developed and evaluated by LaRC pilots during the landing phase of light aircraft operations. The Landing Site Indicator (LASI) system display consists of angle of attack, angle of sideslip, and indicated airspeed images superimposed on the pilot's view through the windshield. The information is made visible to the pilot by means of a partially reflective viewing screen which is suspended directly in frot of the pilot's eyes. Synchro transmitters are operated by vanes, located at the left wing tip, which sense angle of attack and sideslip angle. Information is presented near the center of the display in the form of a moving index on a fixed grid. The airspeed is sensed by a pitot-static pressure transducer and is presented in numerical form at the top center of the display.

Fuller, H. V.↗

Investigation of rotor blade element airloads for a teetering rotor in the blade stall regime (second wind tunnel test)

A test was conducted in the NASA-Ames 7 x 10 ft low speed wind tunnel on a seven-foot diameter model of a teetering rotor. The objectives of the test were: (1) acquire pressure data for correlation with laser and flow visualization measurements; (2) explore rotor propulsive force limits by varying the advance ratio at constant lift and propulsive force coefficients; (3) obtain additional data to define the differences between teetering and articulated rotors; and (4) verify the acceleration sensitivity of experimental transducers. Results are presented.

Dadone, L. U.↗

A tactile paging system for deaf-blind people, phase 1

A tactile paging system for deaf-blind people has been brought from the concept stage to the development of a first model. The model consists of a central station that transmits coded information via radio link to an on-body (i.e., worn on the wrist) receiving unit, the output from which is a coded vibrotactile signal. The model is a combination of commercially available equipment, customized electronic circuits, and electromechanical transducers. The paging system facilitates communication to deaf-blind clients in an institutional environment as an aid in their training and other activities. Several subunits of the system were individually developed, tested, and integrated into an operating system ready for experimentation and evaluation. The operation and characteristics of the system are described and photographs are shown.

Baer, J. A.↗

Loadcell supports for a dynamic force plate

An apparatus was developed to accurately measure components of force along three mutually perpendicular axes, torque, and the center of pressure imposed by the foot of a subject walking over its surface. The data obtained were used to supplement high-speed motion picture and electromyographic (EMG) data for in-depth studies of normal or abnormal human gait. Significant features of the design (in particular, the mechanisms used to support the loadcell transducers) are described. Results of the development program and typical data obtained with the device are presented and discussed.

Keller, C. W.↗

Software for Digital Acquisition System and Application to Environmental Monitoring

Criteria for selection of a minicomputer for use as a core resident acquisition system were developed for the ODU Mobile Air Pollution Laboratory. A comprehensive data acquisition program named MONARCH was instituted in a DEC-8/E-8K 12-bit computer. Up to 32 analog voltage inputs are scanned sequentially, converted to BCD, and then to actual numbers. As many as 16 external devices (valves or any other two-state device) are controlled independently. MONARCH is written as a foreground-background program, controlled by an external clock which interrupts once per minute. Transducer voltages are averaged over user specified time intervals and, upon completion of any desired time sequence, outputted are: day, hour, minute, second; state of external valves; average value of each analogue voltage (E Format); as well as standard deviations of these values. Output is compatible with any serially addressed media.

Copeland, G. E.↗

Sonic environment of aircraft structure immersed in a supersonic jet flow stream

Test methods for determining the sonic environment of aircraft structure that is immersed in the flow stream of a high velocity jet or that is subjected to the noise field surrounding the jet, were investigated. Sonic environment test data measured on a SCAT 15-F model in the flow field of Mach 1.5 and 2.5 jets were processed. Narrow band, lateral cross correlation and noise contour plots are presented. Data acquisition and reduction methods are depicted. A computer program for scaling the model data is given that accounts for model size, jet velocity, transducer size, and jet density. Comparisons of scaled model data and full size aircraft data are made for the L-1011, S-3A, and a V/STOL lower surface blowing concept. Sonic environment predictions are made for an engine-over-the-wing SST configuration.

Guinn, W. A.↗

Ultrasonic evaluation of high voltage circuit boards

Preliminary observations indicate that an ultrasonic scanning technique may be useful as a quick, low cost, nondestructive method for judging the quality of circuit board materials for high voltage applications. Corona inception voltage tests were conducted on fiberglass-epoxy and fiberglass-polyimide high pressure laminates from 20 to 140 C. The same materials were scanned ultrasonically by utilizing the single transducer, through-transmission technique with reflector plate, and recording variations in ultrasonic energy transmitted through the board thickness. A direct relationship was observed between ultrasonic transmission level and corona inception voltage. The ultrasonic technique was subsequently used to aid selection of high quality circuit boards for the Communications Technology Satellite.

Klima, S. J.↗

System for measuring Reynolds in a turbulently flowing fluid

A system for measuring momentum flux in a turbulently flowing fluid includes: a sensing apparatus for dynamically sensing the mainstream and the cross velocity components of the fluid, a transducer operative to provide two electrical output signals representative of the velocity components in the mainstream and in the cross direction, and signal processors to derive the Reynolds stress wave and the Reynolds stress.

Cheng, D. Y.↗

Results of tests CS4 and CS5 to investigate dynamic loads and pressures on 0.03-scale models (Ax1319-3/4 and 45-0) of mated 747 cam and space shuttle orbiter in the Boeing transonic wind tunnel

A 0.03-scale model of the 747 CAM/Orbiter was tested in an 8 x 12 foot transonic wind tunnel. Dynamic loads, pressure, and empennage flow field data were obtained using pressure transducers, strain gages, and a split film anemometer. The test variables included Mach number, angle of attack, sideslip angle, orbiter tailcone on and off, orbiter partial tailcone, orbiter nozzle air scoops, orbiter body flap angle, and orbiter elevon angle.

Source record↗