Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERMOCOUPLES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Thermodynamic Measurements Using the Knudsen Cell Technique

The Knudsen cell technique has been used for over a century and is a valuable tool for measurement of vapor pressures and thermodynamic properties. It is based on a small enclosure (~1 cm long x 1 cm diameter) in which a condensed phase/vapor equilibria can be established. A small (<1 mm) orifice on the cell allows sampling of the vapor via a variety of techniques including weight loss, torsion effusion, target collection, and mass spectrometry. Many excellent measurements based on these methods have been reported. However in order to obtain reliable measurements, a variety of factors must be considered. They include proper cell material selection, accurate and uniform temperature control and measurement, and proper sampling of the vapor. Each of these factors are discussed in detail in this chapter. Typically these studies are conducted at high temperatures and it is a challenge to select an inert container material. Recommended materials are discussed and in some cases the container may be used as part of the system under study. Temperature control and measurement is perhaps the most important issue. In most systems, the furnace must be compact yet there can be no temperature gradient in the cell. Temperatures are measured with either a thermocouple or pyrometer and the relative advantages of each are discussed. Sampling method considerations depend on the particular technique. It is essential that all of the vapor or a representative portion of the vapor be sampled. The distribution of the effusate from a Knudsen cell is discussed and sampling positions discussed. Mass spectrometry is often used to study the effusing vapor and the relations between ion current and vapor pressure are discussed.

mass spectrometry↗

PIV and Rotational Raman-Based Temperature Measurements for CFD Validation of a Perforated Plate Cooling Flow Part I

Film cooling is used in a wide variety of engineering applications for protection of surfaces from hotor combusting gases. The design of more efficient film cooling geometries/configurations could be facilitated by an ability to accurately model and predict the effectiveness of current designs using computational fluid dynamics (CFD) code predictions. Hence, a benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Both Particle Image Velocimetry (PIV) and spontaneous rotational Raman scattering (SRS) spectroscopy were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms temperatures in a film cooling flow field. In addition to off-body flow field measurements, infrared thermography (IR) and thermocouple measurements on the plate surface enabled estimates of the film effectiveness. Raman spectra in air were obtained across a matrix of axial locations downstream from a 68.07 mm square nozzle blowing heated air over a range of temperatures (up to TR =2.7) and Mach numbers (up to Mach 0.9), across a 30.48 cm long plate equipped with three patches of 45 small (~1 mm) diameter cooling holes arranged in a staggered configuration. In addition, both streamwise 2-component PIV (along the plate centerline) and cross-stream 3-component Stereo PIV data at 14 axial stations were collected in the same flows. Only a subset of the data collected in the test program is included in this Part 1 report. The rest of the data will be published in a future report, Part 2, along with planned CFD predictions of the complex cooling film flow.The entire data set of Raman temperature data, PIV velocity data and IR camera data covering the Set Points 23 and 49 in the test matrix in Table 1 is available in an accompanying DVD (available online from www.sti.nasa.gov) for those interested in further analysis.

Mark P Wernet↗

Streak Instabilities on HIFiRE-5 Elliptic Cone

The Hypersonic International Flight Research and Experimentation (HIFiRE) 5 flight experiment by the Air Force Research Laboratories and Australian Defense Science and Technology Organization yielded inflight, hypersonic transition data for a canonical, 3D configuration in the form of an elliptic cone at various combinations of angle-of-attack and yaw. Previous analysis has shown that boundary-layer stability calculations for the as-flown, zero-yaw flight conditions are able to capture the second mode dominated transition along the attachment line as well as the crossflow induced transition in between the attachment line and the minor axis symmetry plane. However, there is still a need to understand the transition in the vicinity of the minor axis plane of symmetry, where the boundary layer thickness exhibits an azimuthally compact bulge due to the collision of the secondary flow approaching from the attachment lines on both sides. This paper reports a computational analysis of the stability of the boundary layer flow along the bulge regions on both the leeward and windward sides of the vehicle surface. At a representative flight condition corresponding to a time instant of t = 514.813 seconds, computations are performed to identify several different unstable modes within the bulge regions, with the eventual goal of developing a linear stability correlation for the transition onset near the minor axis symmetry plane. The most amplified flow instabilities in the pretransitional region correspond to a “stem” mode that is concentrated within a pair of nearly vertical shear layers below the cap of the mushroom shaped bulge in the mean velocity contours. An excellent agreement is found between the predictions of instability amplification based on the plane marching parabolized stability equations (PSE) and the direct numerical solutions (DNS). Given the large number of unstable modes within the bulge region, the observed agreement demonstrates, for first time, that the PSE can provide accurate predictions for the development of flow instabilities in streak-like flow features over three-dimensional bodies. The peak N-factor of approximately 15 at the transition location estimated from the thermocouple measurements along the leeward centerline is close to the transition N-factor for Mack mode transition during the HIFiRE-1 circular cone flight experiment with nearly zero degrees angle of attack.

Meelan Choudhari↗

TPSAS-NF1676L-16463-DND

Ceramic Matrix Composites (CMCs) have been proposed for hot structures in scramjet combustors. Previous studies have calculated significant weight savings by utilizing CMCs (active and passive) versus actively cooled metallic scramjet structures. Both a C/C and a C/C-SiC material system fabricated by DLR (Stuttgart, Germany) are being considered for use in a passively cooled combustor design for HIFiRE 8, a joint Australia / AFRL hypersonic flight program, expected to fly at Mach 7 for ~ 30 sec, at a dynamic pressure of 55 kPa. Flat panels of the DLR C/C and the C/C-SiC were tested in the NASA Langley Direct Connect Rig (DCR) at Mach 5 and Mach 6 enthalpy for several minutes. Gaseous hydrogen fuel was used to fuel the scramjet combustor. The test panels were instrumented with embedded Type K and Type S thermocouples. Zirconia felt insulation was used in some of the tests to increase the surface temperature of the C/C-SiC panel ~ 350?F. The final C/C-SiC panel was tested for 3 cycles totaling over 135 sec at Mach 6 enthalpy. Slightly more erosion was observed on the C/C panel than the C/C-SiC panels, but both material systems demonstrated acceptable recession performance for the HIFiRE 8 flight.

David E Glass↗

Instrumentation for Measuring Entry Radiative Heating - Past, Present, and Future

Radiative heating can be a significant contributor to the total heat load during atmospheric entry, especially for large vehicles with high entry velocties. For example, the stagnation region heat load derived from thermocouples embedded in the thermal protection system (TPS)of the Mars Science Laboratory (MSL) heatshield did not match the unmargined pre-flight predictions. This was at least partially attributed to the fact that radiative heating was not accounted for in the unmargined pre-flight predictions [2].Since MSL, significant work has been done to update radiative heating models and test how the models perform compared to ground-based test facilities such as shock tubes. The models and ground-based tests have shown that radiative heating can be significant for entry into the atmospheres of Venus, Earth, Mars, and Titan, among other planetary bodies. However, there are still discrepancies between the models and the test data, which is where the desire for flight data comes in to play. Missions that have had or are currently planned to have instrumentation to measure radiative heating during atmospheric entry are listed in Table 1.

R A Miller↗

Characterization of Radiative Heating Anomaly in High Enthalpy Shock Tunnels

Surface heating measurements in shock tunnels operating at high enthalpy have previously showed anomalously high heating, the mechanisms for which have been the subject of much speculation. However, recent tests in JAXA’s High Enthalpy Shock Tunnel (HIEST) have presented compelling evidence that the heating anomaly is due to radiation from the shock layer, produced by impurities within the shock. This paper describes a test series performed with an Apollo capsule model at angle of attack. The purpose of the test is nominally to study transition over the capsule model at high enthalpy, however data is confounded by the presence of this radiative heating. The model is thus instrumented with thermocouple heat flux gauges and spectrometer-coupled fiber optics to characterize the spectrum of radiative heating simultaneous to the heat flux measurements. Analyses of the spectra, estimates of radiative heating corrections, and comparison to computational fluid dynamic simulation of the shock tunnel are presented.

Brett A Cruden↗

Analysis of the Honeywell Uncertified Research Engine with Ice Crystal Cloud Ingestion at Simulated Altitudes

The Honeywell Uncertified Research Engine (HURE), a research version of a turbofan engine that never entered production, was tested in the NASA Propulsion System Laboratory (PSL), an altitude test facility at the NASA Glenn Research Center. The PSL is a facility that is equipped with water spray bars capable of producing an ice cloud consisting of ice particles, having a controlled particle diameter and concentration in the air flow. To develop the test matrix of the HURE, numerical analysis of flow and ice particle thermodynamics was performed on the compression system of the turbofan engine to predict operating conditions that could potentially result in a risk of ice accretion due to ice crystal ingestion. The goal of the test matrix was to provide operating conditions such that ice would accrete in either the fan-stator through the inlet guide vane region of the compression system or within the first stator of the high pressure compressor. The predictive analyses were performed with the mean line compressor flow modeling code (COMDESMELT) which includes an ice particle model. The HURE engine was tested in PSL with the ice cloud over the range of operating conditions of altitude, ambient temperature, simulated flight Mach number, and fan speed with guidance from the analytical predictions. The engine was fitted with video cameras at strategic locations within the engine compression system flow path where ice was predicted to accrete, in order to visually confirm ice accretion when it occurred. In addition, traditional compressor instrumentation such as total pressure and temperature probes, static pressure taps, and metal temperature thermocouples were installed in targeted areas where the risk of ice accretion was expected. The current research focuses on the analysis of the data that was obtained after testing the HURE engine in PSL with ice crystal ingestion. The computational method (COMDES-MELT) was enhanced by computing key parameters through the fan-stator at multiple span wise locations, in order to increase the fidelity with the current mean-line method. The Icing Wedge static wet-bulb temperature thresholds were applied for determining the risk of ice accretion in the fan-stator, which is thought to be an adiabatic region. At some operating conditions near the splitter-lip region, other sources of heat (non-adiabatic walls) were suspected to be the cause of accretion, and the Icing Wedge was not applied to predict accretion at that location. A simple order-of-magnitude heat transfer model was implemented into the COMDES-MELT code to estimate the wall temperature minimum and maximum thresholds that support ice accretion, as observed by video confirmation. The results from this model spanned the range of wall temperatures measured on a previous engine that experienced ice accretion at certain operating conditions. The goal of this study is to show that the computational process developed on earlier engine icing tests can be used to provide an icing risk assessment in adiabatic regions for other engines.

Turbofan engine↗

High-Fidelity Simulations of HyMETS Arc-Jet Flows for PICA-N Modeling

Arc-jet testing is a fundamental tool in the screening of thermal protection systems under atmospheric entry conditions. In this work, high-fidelity computational fluid dynamics simulations coupled with machine learning methods for the Hypersonic Materials Environmental Test System arc-jet facility have been carried out. This effort improves the MEDLI-2 data reconstruction fidelity by understanding the impact of the NuSil coating over the PICA thermocouple plugs. Thermochemical non-equilibrium models are employed to simulate the flows inside the arc-jet nozzle and chamber and machine learning techniques are used to calibrate the arc-jet inflow conditions. The material response is simulated with the recession and in-depth numerical results compared to experimental measurements.

STMD↗

Mars 2020 Mobility Actuator Thermal Testing and Model Correlation

This paper describes the thermal testing and model correlation of a mobility actuator planned for use on the Mars 2020 Rover. The mobility actuator is identical to those which have been successfully flown and operated on the Mars Science Laboratory (MSL) Curiosity rover since its successful landing on Mars in August of 2012. The actuator consists of a motor, brake, and encoder paired with a four stage planetary gear box. In this thermal test, the actuator was instrumented with a number of thermocouples on both the interior and exterior of the gearbox. Heaters and a cold plate were used to generate thermal gradients across the actuator in vacuum, low pressure GN2, and low pressure CO2 environments in an effort to correlate a thermal model and develop a better understanding of how heat flows through the mechanism. This testing resulted in the successful model correlation of a simplified thermal model, and yielded important insights regarding the conductance of ball bearings and gear-to-gear contact. Ball bearing thermal conductance in a low pressure environment can be estimated by using correlations for vacuum thermal conductance along with a multiplier to account for increased gas conduction, and gear-to-gear conductance can be estimated by accounting for gas and grease conduction between two gears.

Novak, Keith↗

3D Material Response of the MSL Heatshield Using NuSil-Coated PICA

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield that used NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performance for protecting probes during planetary entry. Data from the Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. A space-grade silicone-based coating commercially known as NuSil CV-1144-0 [3] was applied to the entire MSL heatshield, including the MEDLI plugs, to mitigate the spread of dust from PICA. Modeling the thermal response of PICA-NuSil (PICA-N) system is still an open challenge. Ground testing of PICA-N models exhibited surface temperature jumps of the order of 150 K due to oxide scale formation and sub-sequent NuSil burn-off. It is therefore critical to include a validated model for the material response of the coating in engineering codes. A test campaign has been conducted at the NASA’s Langley HyMETS [4] facility to screen the response of PICA-N and gather detailed data on its behavior [5]. A first model of PICA-N thermal response has been developed using the Hy-METS experiments [6]. The objective of this work is to analyze the material response of the latest PICA-N model compared to the engineering model used to simulate the entry of MSL. The environment and material response around the MSL aeroshell during Mars atmospheric entry is simulated using a collection of tools. The Direct Simulation Monte Carlo SPARTA code [7] is used in the rarefied regime, the Data Parallel Line Relaxation (DPLR) code [8] is used in the continuum regime and radiative heating conditions are provided by the Nonequilibrium air radiation (NEQAIR) code [9] to estimate the environmental conditions. The thermal response inside the material is computed using the Porous material Analysis Toolbox based on Open-FOAM (PATO) [10,11,12]. Thermodynamic and chemistry properties are estimated using the Mutation++ library [13]. The approach implemented in PATO as a first cut PICA-N thermal response model is outlined in Figure 1. While the recession is less than the coating thickness, the Surface mass and energy balance Boundary Condition (SBC) uses the NuSil B’ tables. Once the recession removes the coating, the usual PICA B’ tables are used for the SBC. The B’ tables are computed using an equilibrium solver implemented in Mutation++, given the temperature, pressure, blowing rate, composition of the pyrolysis and environment gases, and the condensed species at the surface. Preliminary results of the 3D material response of the MSL heat-shield at the peak heating (80 sec after Entry Interface) are shown in Figure 2. Current NASA’s mission to Mars, Mars 2020, used the spare heatshield of MSL for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the PATO high-fidelity material response capability was benchmarked against flight data from MEDLI. This effort represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes. This bench-marking is awaiting the final release of the MEDLI-2 data.

Aerospace↗

LOFTID Heat Flux Gauge Calibration: What is Truth?

The Low-Earth Orbit Flight Test of an Inflatable Decelerator (LOFTID) is a demonstration of Hypersonic Inflatable Aerodynamic Decelerator (HIAD) technology, which may enable the delivery of heavy payloads to Mars, Venus, and Titan, as well as return to Earth. Unlike rigid aeroshells that are constrained by the size of the rocket’s shroud, inflatable aeroshells can be deployed to a much larger scale, thus allowing a spacecraft to begin its deceleration earlier and experience less heating. On LOFTID, there will be 4 total heat flux gauges (HFG) with a range of 70 W/cm2 and 1 radiometer with a range of 3 W/cm2, arranged as shown in Fig. 1. Both the radiometer and total HFGs are Schmidt-Boelter gauges purchased from an external vendor. Radiative calibrations were performed in-house at NASA Ames’ Sensors and TPS Advanced Research Laboratories (STAR Labs) before and after environmental testing to investigate how the testing affected the sensors' response. Additional rounds of radiative calibration at STAR Labs were also performed in order to investigate the large uncertainties associated with these tests. For example, a survey of multiple calibration facilities concluded that the uncertainty within a given facility was +/-3% [1]. An additional NIST study that calibrated heat flux gauges at 7 different facilities also found the variation in calibration coefficients to be up to ~3% within a given facility, but up to 15% between facilities, suggesting systematic differences between test setups [2]. Finally, the response of heat flux gauges to radiative versus convective heat flux has shown to differ by up to 20% [3],[4]. Because the heat flux gauges on LOFTID will predominantly experience convective heat flux during flight, a convective calibration study was performed at Boeing's Large-Core Arc Tunnel (LCAT) facility. Radiative Calibration Procedure The calibrations performed at STAR Labs utilize a quartz lamp bank (QLB) that provides a maximum heat flux of 50 W/cm2, which bounds the expected LOFTID flight environment. The calibration involves exposing a water-cooled Gardon gauge (reference) and then the unit-under-test (UUT) to 5 different heat fluxes multiple times for 10 seconds each, and then calculating a linear fit. The test setup is shown in Fig. 2. The total HFGs were calibrated at STAR Labs 3 times, denoted as STAR 1 (before environmental testing), STAR 2 (after protoflight vibration and thermal-vacuum testing), and STAR 3 (no change from previous test). All 8 flight-lot total HFGs showed a decrease in full-scale output from STAR 1 to STAR 2 by between 0.5% and 10. The first portion of this investigation was to determine whether the change could be due to differences in temperature between the two calibration runs. A typical linear fit to the calibration data was performed using Eq. 1 where q’ is the heat flux in W/cm2, c is the calibration coefficient, and mV is the sensor output. To account for temperature, the data were fit to a nonlinear function that included both the sensor output (mV) and the temperature from the thermocouple embedded inside the HFG near the surface (T): q'=mV/(c1* T + c0}. The residuals between the fits and the actual data points were calculated for every point, and proven to be much smaller for the temperature-compensated fits than for the linear fits for all sensors. An example is shown in Fig. 3. When the temperature-compensated fits from STAR 1 were applied to the STAR 2 data, the residuals did not improve, suggesting that the change in sensitivity between these two calibration runs was not due to temperature. A third round of calibration (STAR 3) was conducted to further address the temperature dependence of the total HFGs, and the resulting sensitivities matched closely to STAR 2 (within 2%). Temperature-compensated calibration curves were once again fit to the data. In this case, when the temperature-compensated fits from STAR 3 were applied to STAR 2 data, the residuals between the fits and STAR 2 data were much lower than the residuals due to the linear fits. This suggests that the changes seen between STAR 1 and STAR 2 were likely due to actual changes in the sensors caused by the environmental testing between the two calibrations. A modification of the original calibration process, in which the UUT was exposed to each heat flux for just 3 seconds (instead of 10) to reduce the temperature increase during the test, was additionally performed on several of the HFGs. In general, the sensitivities were 1-1.5% lower than from the 10-second tests, but the temperatures were also significantly lower. When the temperature-compensated fits from the 10-second tests were applied to the 3-second test data, the residuals were greatly improved than when just using the linear fits, further suggesting that the temperature-compensated fits may lead to better accuracy than the linear fits in flight. Convective Calibration The second portion of this study was to create a mapping between the radiative and convective calibration coefficients. The majority of the heating during flight will be convective, so it is important to understand how the HFG response differs under these conditions. However, there are no standardized methods for convective calibration [5]. Because the TPS aerothermal response models were validated at LCAT, the same facility was chosen for convective calibration of two of the total HFGs (Fig. 4). Preliminary results showed that the full-scale output was 3% and 8% higher in convective heat flux as compared to radiative heat flux. However, tunnel variation may have contributed to noise and uncertainty in the measurements, and more testing and analysis remains to be done. Scope of Presentation The presentation will include an overview of the changes seen in HFG calibration before and after environmental testing, differences between radiative and convective calibrations, the modeling work done to aid in understanding the sensor response to varying environments, and recommended future work.

H S Alpert↗

The Mars Environmental Dynamics Analyzer, MEDA. A Suite of Environmental Sensors for the Mars 2020 Mission

NASA’s Mars 2020 (M2020) rover mission includes a suite of sensors to monitor current environmental conditions near the surface of Mars and to constrain bulk aerosol properties from changes in atmospheric radiation at the surface. The Mars Environmental Dynamics Analyzer (MEDA) consists of a set of meteorological sensors including wind sensor, a barometer, a relative humidity sensor, a set of 5 thermocouples to measure atmospheric temperature at ∼1.5 m and ∼0.5 m above the surface, a set of thermopiles to characterize the thermal IR brightness temperatures of the surface and the lower atmosphere. MEDA adds a radiation and dust sensor to monitor the optical atmospheric properties that can be used to infer bulk aerosol physical properties such as particle size distribution, non-sphericity, and concentration. The MEDA package and its scientific purpose are described in this document as well as how it responded to the calibration tests and how it helps prepare for the human exploration of Mars. A comparison is also presented to previous environmental monitoring payloads landed on Mars on the Viking, Pathfinder, Phoenix, MSL, and InSight spacecraft.

J. A. Rodriguez-Manfredi↗

ANALYSIS OF THE MSL/MEDLI ENTRY DATA WITH COUPLED CFD AND MATERIAL RESPONSE.

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heat-shield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material. PICA is a lightweight carbon fiber/polymeric resin material that offers out-standing performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP). The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on Open-FOAM (PATO) using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA, is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Mars Science Laboratory↗

Simulation-Aided Design and Interpretation of Results of Microgravity-Based Solidification Experiments

The preparation and interpretation of microgravity experiments conducted on the International Space Station (ISS) can be challenging because of the remote location of the equipment. Although a “ground unit” is typically available on Earth, it is not located in the laboratory of the principal investigator. Furthermore, test experiments in the ground unit cannot fully duplicate heat transfer conditions of the weightless environment, and thus be a reliable reference for experiment design. Under such conditions, numerical simulations are a valuable tool both for preparing the experiments and interpreting the results obtained under terrestrial and micro-gravity conditions. In this work, we developed a detailed 3D model of the “SUBSA” furnace located at the ISS, and demonstrate its use in our present investigation which includes melt growth and vapor growth of InI crystals on the ISS. In 2002, the SUBSA furnace was designed and built for the growth of InSb crystals in the Microgravity Science Glovebox (MSG) at the ISS. The SUBSA furnace features a transparent section without heating elements, where the axial temperature gradient is high. In our present investigation, we have used the same furnace to grow four InI crystals from the melt, and two InI crystals from the vapor phase (2018-2021). InI crystals have ~20 times lower thermal conductivity than InSb crystals. As a result, during melt growth, the InI crystals were exposed to extremely high temperature gradients. To reduce the axial temperature gradient, we added external jackets made from high thermal conductivity material to the growth ampoules. The SUBSA furnace could not be modeled as asymmetric because of its rectangular shape and right-angled transparent section, which contains a convoluted geometry. The rectangular shape of the transparent section further complicates modelling of radiative heat transfer, which dominates in the zone. At present, numerical simulations are being conducted to resolve an apparent discrepancy between the readings of the 5 thermocouples located in the SUBSA furnace, and the observed position of the solid and molten material. The 3D simulation will be presented, along with the calibration and growth experiment results conducted in microgravity and in the SUBSA ground unit. The developed model should be useful for upcoming microgravity investigations planned to be conducted in the SUBSA facility.

V Riabov↗

Plans for Ice Crystal Icing Tests Using a 3D Heated Test Article at the NASA Icing Research Tunnel

This presentation describes the plans for ice crystal icing and supercooled water icing tests to be conducted in Fall/Winter 2021 at the NASA Icing Research Tunnel. A test article, whose geometry is representative of an inter-compressor duct and strut region of a turbofan engine, has been designed and fabricated for the study of ice crystal icing physics tests. The Simulated Inter-compressor Duct Research Model (SIDRM) will have the ability to heat surfaces to simulate the warm surfaces of the inter-compressor duct within an engine. The test article is instrumented with heaters, heat flux gauges, thermocouples, and pressure taps to measure icing behavior. The aim of these tests is to generate ice shapes on the SIDRM test article under well-characterized conditions. The results of the testing with the SIDRM model will be used to provide icing physics and validation data for development of the engine icing simulation capabilities in GlennICE, the 3D ice prediction tool. This is intended to be a presentation only, and does not have an accompanying paper.

ice-crystal icing↗

Temperature and Frequency Dependent Electrical Properties of AVCOAT and Shuttle Tile Material

This technical memorandum presents the data and results from a series of tests performed on AVCOAT, charred AVCOAT, and different Shuttle Thermal Protection System (TPS) tile coatings to determine their electrical properties as a function of temperature and frequency. Initially, the samples were assumed to be insulators and the complex permittivities were measured from data collected by sandwiching each sample between two conductors to form a sandwich. However, the AVCOAT sample data showed that the material becomes conductive as it begins to char. To get an accurate conductivity reading on these charred samples, a four-point resistance probe was used to collect data. Overall, this testing showed that the virgin AVCOAT starts out as a material that is a good insulator but transitions to one with a conductivity on the order of 1860 S/m as it chars. The deeper layers of AVCOAT (un-charred) all exhibited a temperature and frequency dependence that is possibly indicative of a dielectric relaxation in the material. As the sample temperatures were increased, a knee appears in the real permittivity data sets below 1 kHz. Both the real permittivity and resistivity drop up to several orders of magnitude yet show that the material remains an insulator. The Shuttle High Temperature Reusable Surface Insulation (HRSI) tile coatings studied included Reac- tion Cured Glass (RCG), Aluminum Enhanced Thermal Barrier (AETB), and Toughened Unipiece Fibrous Insulation (TUFI). The purely glass fiber parts of the tile were removed leaving only the outer layers con- taining just the coating. The data collected shows that the RCG, AETB, and outermost layer of the TUFI have similar electrical properties. The real permittivity plots show that there appears to be a relaxation that shows up at frequencies below 1 kHz. The relaxation frequency increases with increasing temperature. Also, the real permittivity increases up to about a factor of four between room temperature and 650K. Likewise, the resistivity (related to the imaginary permittivity) decreases up to five orders of magnitude over the same temperature interval, but still remains an insulator. This data was collected to support a NASA Engineering and Safety Center (NESC) assessment team investigating the source of thermocouple anomalies in both Shuttle TPS material and AVCOAT used for on the Orion spacecraft for Exploration Flight Test 1 (EFT-1). The details of their findings will be documented in a separate report with this document serving as a reference.

Mark A Nurge↗

Bluntness and Supersaturation Effects on the Second Mode Instability in Mach 10 Flow

An experimental campaign was conducted on a 7-degree half-angle cone in the NASA Langley Research Center 31-Inch Mach 10 Tunnel to investigate the impact of nosetip radius and freestream supersaturation on the development of the second mode instability. The model was instrumented with surface-mounted Kulite® and PCB® pressure transducers and thermocouples. Power spectral density plots demonstrate the anticipated trends of the second mode instability weakening and shifting to lower frequencies with increased bluntness. Heat transfer measurements suggest laminar flow over the bulk of the model for most testing conditions, with evidence of transition by the cone base for the sharpest nosetip (R = 0.15 mm) at the higher unit Reynolds numbers. The dynamic surface pressure and heat transfer measurements show that reducing the temperature of the freestream to a supersaturated state has a significant stabilizing effect on the model boundary layer. The surface measurements are observed to be highly dependent on the level of clustering in the freestream. Significant changes in surface pressure spectra due to total temperature reduction are first noted below T0= 948 K, while more substantial fluctuation reductions are found below T0= 810 K.

Hypersonics↗

Analysis of MSL/MEDLI Entry Data with Coupled CFD and Material Response

The Mars Science Laboratory (MSL) was protected during its atmospheric entry by an instrumented heatshield using NASA's Phenolic Impregnated Carbon Ablator (PICA) material [1]. PICA is a lightweight carbon fiber/polymeric resin material that offers outstanding performances for protecting probes during planetary entry. The Mars Entry Descent and Landing Instrument (MEDLI) suite on MSL offers unique in-flight validation data for models of material response and atmospheric entry. MEDLI recorded, among other things, time-resolved in-depth temperature data of PICA using thermocouple sensors assembled in the MEDLI Integrated Sensor Plugs (MISP) [2]. The objective of this work is to showcase and analyze the coupling between the material response and the aerothermal environment. As shown in Figure 1, the workflow is divided into the following steps. First, the aerothermal properties are computed in the Data Parallel Line Relaxation (DPLR) code [3] and used with the Nonequilibrium air radiation (NEQAIR) program [8] to compute radiative heating. Second, the thermal response inside the material is computed in the Porous material Analysis Toolbox based on OpenFOAM (PATO) [4,5,6] using a fixed blowing correction parameter. Third, the pyrolysis gases computed in PATO are used as inputs to a blowing boundary condition within DPLR. Fourth, the new environment properties from DPLR are used in NEQAIR to provide an updated solution, then both the updated aerothermal environment and radiative heating are used in PATO without blowing correction. The third and fourth steps are then repeated until convergence in surface temperature is obtained. Convergence in the radiative heating is generally achieved before surface temperature, at which point the radiative heating is no longer updated. Char mass loss rates are forced to zero to produce a non-receding surface condition. For early time points in the trajectory, where flow around the MSL aeroshell is rarefied, the Direct Simulation Monte Carlo (DSMC) code, SPARTA [7], is used to compute the aerothermal environment. Iteration between PATO and SPARTA is not performed due to the computational cost of DSMC simulations. Preliminary results of the coupling between PATO and DPLR for the MSL heatshield atmospheric entry model are presented in Figures 2-4 at 65 seconds after entry interface. Figure 2 shows the surface temperature results from an uncoupled simulation in PATO with the blowing correction parameter applied (left) along with the coupled surface temperature after iteration (right). Figure 3 shows the surface temperature along the centerline from windward to leeward for easier comparison. Figure 4 shows the coupled and uncoupled pyrolysis gas blowing rate. Mars 2020 used a similar heatshield consisting of PICA for thermal protection during entry, descent, and landing. In preparation for Mars 2020 post-flight analysis, the predictive material response capability is benchmarked against flight data from MEDLI. This work represents an important milestone toward the development of validated predictive capabilities for designing thermal protection systems for planetary probes.

Thermal Protection Systems↗