Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “THERAPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Validation and Comparison of the Therapeutic Efficacy of Boron Neutron Capture Therapy Mediated By Boron-Rich Liposomes in Multiple Murine Tumor Models

Boron neutron capture therapy (BNCT) was performed at the University of Missouri Research Reactor in mice bearing CT26 colon carcinoma flank tumors and the results were compared with previously performed studies with mice bearing EMT6 breast cancer flank tumors. We implanted mice with CT26 tumors subcutaneously in the caudal flank and were given two separate tail vein injections of unilamellar liposomes composed of cholesterol, 1,2-distearoyl-sn-glycer-3-phosphocholine, and K[nido-7-CH 3 (CH 2 ) 15 –7,8-C 2 B 9 H 11 ] in the lipid bilayer and encapsulated Na 3 [1-(2`-B 10 H 9 )-2-NH 3 B 10 H 8 ] within the liposomal core. Mice were irradiated 30 hours after the second injection in a thermal neutron beam for various lengths of time. The tumor size was monitored daily for 72 days. In spite of relatively lower tumor boron concentrations, as compared to EMT6 tumors, a 45 minute neutron irradiation BNCT resulted in complete resolution of the tumors in 50% of treated mice, 50% of which never recurred. Median time to tumor volume tripling was 38 days in BNCT treated mice, 17 days in neutron-irradiated mice given no boron compounds, and 4 days in untreated controls. Tumor response in mice with CT26 colon carcinoma was markedly more pronounced than in previous reports of mice with EMT6 tumors, a difference which increased with dose. The slope of the dose response curve of CT26 colon carcinoma tumors is 1.05 times tumor growth delay per Gy compared to 0.09 times tumor growth delay per Gy for EMT6 tumors, indicating that inherent radiosensitivity of tumors plays a role in boron neutron capture therapy and should be considered in the development of clinical applications of BNCT in animals and man.

60 APPLIED LIFE SCIENCES↗

Solution Thermodynamics and Kinetics of Metal Complexation with a Hydroxypyridinone Chelator Designed for Thorium-227 Targeted Alpha Therapy

In this study, the solution chemistry of a chelator developed for 227 Th targeted alpha therapy was probed. The compound of interest is an octadentate ligand comprising four N-methyl-3-hydroxy-pyridine-2-one metal-binding units, two tertiary amine groups, and one carboxylate arm appended for bioconjugation. The seven pK a values of the ligand and the stability constants of complexes formed with Th(IV), Hf(IV), Zr(IV), Gd(III), Eu(III), Al(III), and Fe(III) were determined. The ligand exhibits extreme thermodynamic selectivity toward tetravalent metal ions with a ca. 20 orders of magnitude difference between the formation constant of the Th(IV) species formed at physiological pH, namely [ThL] - , and that of its Eu(III) analogue. Likewise, log β 110 values of 41.7 ± 0.3 and 26.9 ± 0.3 (T = 25 °C) were measured for [ThL] - and [Fe III L] 2- , respectively, highlighting the high affinity and selectivity of the ligand for Th ions over potentially competing endogenous metals. Single crystal X-ray analysis of the Fe(III) complex revealed a dinuclear 2:2 metal:chelator complex crystallizing in the space group P1 - . The formation of this dimeric species is likely favored by several intramolecular hydrogen bonds and the protonation state of the chelator in acidic media. L III edge EXAFS data on the Th(IV) complexes of both the ligand and a monoclonal antibody conjugate revealed the expected mononuclear 1:1 metal:chelator coordination environment. This was also confirmed by high resolution mass spectrometry. Lastly, kinetic experiments demonstrated that labeling the bioconjugated ligand with Th(IV) could be achieved and completed after 1 h at room temperature, reinforcing the high suitability of this chelator for 227 Th targeted alpha therapy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The paradox of highly effective sofosbuvir-based combination therapy despite slow viral decline: can we still rely on viral kinetics?

High sustained virologic response (SVR) rates have been observed after 6 weeks of anti-HCV treatment using sofosbuvir, ledipasvir and a non-nucleoside polymerase-inhibitor (GS-9669) or a proteaseinhibitor (GS-9451) and after 12 weeks with sofosbuvir+ledipasvir. Here we analyze the viral kinetics observed during these treatments to decipher the origin of the rapid cure and to evaluate the possibility of further reducing treatment duration. We found that viral kinetics were surprisingly slow in all treatment groups and could not reproduce the high SVR rates observed. Based on experimental results suggesting that NS5A- or protease-inhibitors can generate non-infectious virus, we incorporated this effect into a mathematical model. We found that to predict observed SVR rates it was necessary to assume that ledipasvir, GS-9669 and GS-9451 rapidly reduce virus infectivity. We predicted with this model that 4 weeks of triple therapy could be sufficient to achieve SVR in patients with undetectable viremia at week 1, but would be suboptimal in general. In conclusion, the rapid cure rate achieved with these combinations is largely disconnected from viral loads measured during treatment. A model assuming that rapid cure is due to a drug effect of generating non-infectious virus could be a basis for future response guided therapy.

60 APPLIED LIFE SCIENCES↗

Magnetic/NIR-responsive drug carrier, multicolor cell imaging, and enhanced photothermal therapy of gold capped magnetite-fluorescent carbon hybrid nanoparticles

In our paper reports a type of multifunctional hybrid nanoparticle (NP) composed of gold nanocrystals coated on and/or embedded in a magnetite-fluorescent porous carbon core-shell NP template (Fe 3 O 4 @PC-CDs-Au) for biomedical applications, including magnetic/NIR-responsive drug release, multicolor cell imaging, and enhanced photothermal therapy. The synthesis of the Fe 3 O 4 @PC-CDs-Au NPs firstly involves the preparation of core-shell template NPs with magnetite nanocrystals clustered in the cores and fluorescent carbon dots (CDs) embedded in a porous carbon shell, followed by an in situ reduction of silver ions (Ag + ) loaded in the porous carbon shell and a subsequent replacement of Ag NPs with Au NPs through a galvanic replacement reaction using HAuCl 4 as a precursor. Moreover, the Fe 3 O 4 @PC-CDsAu NPs can enter the intracellular region and light up mouse melanoma B16F10 cells in multicolor mode. The porous carbon shell, anchored with hydrophilic hydroxyl/carboxyl groups, endows the Fe 3 O 4 @PC-CDs-Au NPs with excellent stability in the aqueous phase and a high loading capacity (719 mg g -1 ) for the anti-cancer drug doxorubicin (DOX). The superparamagnetic Fe 3 O 4 @PC-CDs-Au NPs with a saturation magnetization of 23.26 emu g -1 produce localized heat under an alternating magnetic field, which triggers the release of the loaded drug. The combined photothermal effects of the Au nanocrystals and the CDs on/in the carbon shell can not only regulate the release rate of the loaded drug, but also efficiently kill tumor cells under NIR irradiation. Finally, in benefitting from their excellent optical properties, their magnetic field and NIR light-responsive drug release capabilities and their enhanced photothermal effect, such nanostructured Fe 3 O 4 @PC-CDs-Au hybrid NPs are very promising for simultaneous imaging diagnostics and high efficacy therapy.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Electron cyclotron resonance ion source experience at the Heidelberg Ion Beam Therapy Center

Radiotherapy with heavy ions is an upcoming cancer treatment method with to date unparalleled precision. It associates higher control rates particularly for radiation resistant tumor species with reduced adverse effects compared to conventional photon therapy. The accelerator beam lines and structures of the Heidelberg Ion Beam Therapy Center (HIT) have been designed under the leadership of GSI, Darmstadt with contributions of the IAP Frankfurt. Currently, the accelerator is under commissioning, while the injector linac has been completed. When the patient treatment begins in 2008, HIT will be the first medical heavy ion accelerator in Europe. This presentation will provide an overview about the project, with special attention given to the 14.5 GHz electron cyclotron resonance (ECR) ion sources in operation with carbon, hydrogen, helium, and oxygen, and the experience of one year of continuous operation. It also displays examples for beam emittances, measured in the low energy beam transport. In addition to the outlook of further developments at the ECR ion sources for a continuously stable operation, this paper focuses on some of the technical processings of the past year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Perspectives of hadron therapy in Mexico

The need for a hadron therapy center in Mexico is presented. The question if such a facility is affordable in Mexico is discussed, addressing the economical factor as well as the expertise and know how available in both the private and the public sector. To conclude, a possible path, and the first steps on it, to move forward towards a medical facility in Mexico devoted to proton therapy are sketched.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of Compact Electron Cyclotron Resonance Ion Source with Permanent Magnets for High-Energy Carbon-Ion Therapy

Heavy-ion cancer treatment is being carried out at the Heavy Ion Medical Accelerator in Chiba (HIMAC) with 140 to 400 MeV/n carbon ions at National Institute of Radiological Sciences (NIRS) since 1994. At NIRS, more than 4,000 patients have been treated, and the clinical efficiency of carbon ion radiotherapy has been demonstrated for many diseases. A more compact accelerator facility for cancer therapy is now being constricted at the Gunma University. In order to reduce the size of the injector (consists of ion source, low-energy beam transport and post-accelerator Linac include these power supply and cooling system), an ion source requires production of highly charged carbon ions, lower electric power for easy installation of the source on a high-voltage platform, long lifetime and easy operation. A compact Electron Cyclotron Resonance Ion Source (ECRIS) with all permanent magnets is one of the best types for this purpose. An ECRIS has advantage for production of highly charged ions. A permanent magnet is suitable for reduce the electric power and cooling system. For this, a 10 GHz compact ECRIS with all permanent magnets (Kei2-source) was developed. The maximum mirror magnetic fields on the beam axis are 0.59 T at the extraction side and 0.87 T at the gas-injection side, while the minimum B strength is 0.25 T. These parameters have been optimized for the production of C{sup 4+} based on experience at the 10 GHz NIRS-ECR ion source. The Kei2-source has a diameter of 320 mm and a length of 295 mm. The beam intensity of C{sup 4+} was obtained to be 618 e{mu}A under an extraction voltage of 30 kV. Outline of the heavy ion therapy and development of the compact ion source for new facility are described in this paper.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Heidelberg Ion Therapy (HIT) Accelerator Coming into Operation

The Heidelberg Ion Therapy Facility (HIT) is the first dedicated proton and carbon therapy facility in Europe. It uses full three dimensional intensity controlled raster scanning as basic treatment technique. Commissioning of the accelerator with beam was successfully finished for three fixed beam places in April 2008. A library of 60000 combinations of beam properties (ion type, treatment place, energy, intensity, beam size) is now offered to the treatment technique teams preparing the treatment systems for the clinical use. The HIT facility also comprises a gantry with full scanning properties constituting the first carbon ion gantry worldwide. The gantry can be rotated by 360 deg., so that the beam may be aimed at the patient from arbitrary directions.

43 PARTICLE ACCELERATORS↗

Ion Beam Therapy in Europe

At present, seven facilities in Europe treat deep-seated tumors with particle beams, six with proton beams and one with carbon ions. Three of these facilities are in Moscow, St. Petersburg and Dubna, Russia. Other facilities include the TSL Uppsala, Sweden, CPO Orsay, France, and PSI Villigen, Switzerland, all for proton therapy, and GSI, Darmstadt, Germany, which utilizes carbon ions only. But only two of these facilities irradiate with scanned ion beams: the Paul Scherer Institute (PSI), Villigen (protons) and the Gesellschaft fuer Schwerionenforschung (GSI), Darmstadt. These two facilities are experimental units within physics laboratories and have developed the technique of intensity-modulated beam scanning in order to produce irradiation conforming to a 3-D target. There are three proton centers presently under construction in Munich, Essen and Orsay, and the proton facility at PSI has added a superconducting accelerator connected to an isocentric gantry in order to become independent of the accelerator shared with the physics research program. The excellent clinical results using carbon ions at National Institute of Radiological Science (NIRS) in Chiba and GSI have triggered the construction of four new heavy-ion therapy projects (carbon ions and protons), located in Heidelberg, Pavia, Marburg and Kiel. The projects in Heidelberg and Pavia will begin patient treatment in 2009, and the Marburg and Kiel projects will begin in 2010 and 2011, respectively. These centers use different accelerator designs but have the same kind of treatment planning system and use the same approach for the calculation of the biological effectiveness of the carbon ions as developed at GSI [1]. There are many other planned projects in the works. Do not replace the word ''abstract,'' but do replace the rest of this text. If you must insert a hard line break, please use Shift+Enter rather than just tapping your ''Enter'' key. You may want to print this page and refer to it as a style sample before you begin working on your paper.

43 PARTICLE ACCELERATORS↗

Scanned Carbon Pencil Beams for Tumor Therapy

At GSI a fully active beam application has been developed for tumor therapy with carbon ions. In this so-called rasterscan system the tumor volume is typically split into {approx}60 slices of iso-energies taken from a list of 252 energies ranging from {approx}90-430 MeV/u(range: 1.8-30.7 cm). The energies can be combined with variable beam diameters and intensities. For each iso-energy slice beam is requested from the synchrotron and delivered as a narrow pencil beam (beam's full width at half maximum 3-10 mm). For lateral target coverage this pencil beam is deflected to several hundreds of grid positions per iso-energy slice by orthogonal dipole magnets. At each grid position an optimized number of particles is deposited intensity-controlled, i.e. ionization chambers monitor the dose deposition and trigger deflection to the next grid position once the required dose level is achieved. This method allows intensity-modulated treatment fields necessary to deposit a uniform biological effective dose. Additionally, it allows for simultaneous optimization of multiple fields that allow better sparing of organs at risk partially or fully surrounded by the tumor. Scanned beam delivery facilitates target conformal and homogeneous dose delivery for stationary targets. For tumors located in the head and neck as well as tumors in the pelvic region very promising results were achieved in the carbon therapy pilot project started at GSI in 1993. A comparable project is conducted at Paul-Scherrer-Institut (PSI) in Switzerland with a scanned proton beam. One of the current research topics is the treatment of moving targets such as lung tumors. Scanned beam delivery requires but also offers possibilities to conformably irradiate moving target sites.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A 1372-element Large Scale Hemispherical Ultrasound Phased Array Transducer for Noninvasive Transcranial Therapy

Noninvasive transcranial therapy using high intensity focused ultrasound transducers has attracted high interest as a promising new modality for the treatments of brain related diseases. We describe the development of a 1372 element large scale hemispherical ultrasound phased array transducer operating at a resonant frequency of 306 kHz. The hemispherical array has a diameter of 31 cm and a 15.5 cm radius of curvature. It is constructed with piezoelectric (PZT-4) tube elements of a 10 mm in diameter, 6 mm in length and 1.4 mm wall thickness. Each element is quasi-air backed by attaching a cork-rubber membrane on the back of the element. The acoustic efficiency of the element is determined to be approximately 50%. The large number of the elements delivers high power ultrasound and offers better beam steering and focusing capability. Comparisons of sound pressure-squared field measurements with theoretical calculations in water show that the array provides good beam steering and tight focusing capability over an efficient volume of approximately 100x100x80 mm{sup 3} with nominal focal spot size of approximately 2.3 mm in diameter at -6 dB. We also present its beam steering and focusing capability through an ex vivo human skull by measuring pressure-squared amplitude after phase corrections. These measurements show the same efficient volume range and focal spot sizes at -6 dB as the ones in water without the skull present. These results indicate that the array is sufficient for use in noninvasive transcranial ultrasound therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatially resolved measurement of high doses in microbeam radiation therapy using samarium doped fluorophosphate glasses

The measurement of spatially resolved high doses in microbeam radiation therapy has always been a challenging task, where a combination of high dose response and high spatial resolution (microns) is required for synchrotron radiation peaked around 50 keV. The x-ray induced Sm{sup 3+}{yields} Sm{sup 2+} valence conversion in Sm{sup 3+} doped fluorophosphates glasses has been tested for use in x-ray dosimetry for microbeam radiation therapy. The conversion efficiency depends almost linearly on the dose of irradiation up to {approx}5 Gy and saturates at doses exceeding {approx}80 Gy. The conversion shows strong correlation with x-ray induced absorbance of the glass which is related to the formation of phosphorus-oxygen hole centers. When irradiated through a microslit collimator, a good spatial resolution and high ''peak-to-valley'' contrast have been observed by means of confocal photoluminescence microscopy.

36 MATERIALS SCIENCE↗

Nuclear Physics and Hadron Therapy

Hadron therapy uses light charged particles beams (mainly proton and {sup 12}C ions) to irradiate tumors. These beams present a ballistic advantage with a maximum energy deposition at the end of the path. A large dose can be delivered inside a deep tumor while the surrounding healthy tissues are preserved. There is an obvious advantage in using these beams but the beam control has to be achieved and all the physical processes leading to the energy deposition have to be fully under control. This treatment protocol requires accurate control devices and a good knowledge of the physical processes occurring all along the path of the projectile in human tissues. In this report, we will present one example of a beam monitor for the proton therapy. We will also present the experimental program which has been initiated to obtain fundamental data on the nuclear fragmentation process.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Non-equilibrium atmospheric pressure microplasma jet: An approach to endoscopic therapies

Atmospheric pressure microplasma jet generated in a long hollow core optical fiber is studied to verify the potential feasibility of endoscopic therapies. Thermal damage and electric shock to the human body were suppressed by two technical methods, i.e., the high-voltage resistant flexible tube wrapped on the optical fiber and a power resistor of 100 kΩ connected between the power supply and the copper foil electrode. Optical emission spectra analysis indicated that many kinds of active radicals like excited atomic O and OH, were generated in the microplasma jet. In addition, the applications of the microplasma jet on sterilization and lung cancer cell apoptosis were presented. After 5 min of exposures to the microplasma jet, the cell viability and the bacillus subtilis replication decreased to about 3% and zero, respectively. More investigations are needed to improve the plasma-aided endoscopic therapies.

60 APPLIED LIFE SCIENCES↗

Improvements for extending the time between maintenance periods for the Heidelberg ion beam therapy center (HIT) ion sources

The clinical operation at the Heidelberg Ion Beam Therapy Center (HIT) started in November 2009; since then more than 1600 patients have been treated. In a 24/7 operation scheme two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce protons and carbon ions. The modification of the low energy beam transport line and the integration of a third ion source into the therapy facility will be shown. In the last year we implemented a new extraction system at all three sources to enhance the lifetime of extraction parts and reduce preventive and corrective maintenance. The new four-electrode-design provides electron suppression as well as lower beam emittance. Unwanted beam sputtering effects which typically lead to contamination of the insulator ceramics and subsequent high-voltage break-downs are minimized by the beam guidance of the new extraction system. By this measure the service interval can be increased significantly. As a side effect, the beam emittance can be reduced allowing a less challenging working point for the ion sources without reducing the effective beam performance. This paper gives also an outlook to further enhancements at the HIT ion source testbench.

43 PARTICLE ACCELERATORS↗

Reducing the uncertainties in particle therapy

The use of fundamental Nuclear Physics in Nuclear Medicine has a significant impact in the fight against cancer. Hadrontherapy is an innovative cancer radiotherapy method using nuclear particles (protons, neutrons and ions) for the treatment of early and advanced tumors. The main goal of proton therapy is to deliver high radiation doses to the tumor volume with minimal damage to healthy tissues and organs. The purpose of this work was to investigate the dosimetric errors in clinical proton therapy dose calculation due to the presence of metallic implants in the treatment plan, and to determine the impact of the errors. The results indicate that the errors introduced by the treatment planning systems are higher than 10% in the prediction of the dose at isocenter when the proton beam is passing directly through a metallic titanium alloy implant. In conclusion, we recommend that pencil-beam algorithms not be used when planning treatment for patients with titanium alloy implants, and to consider implementing methods to mitigate the effects of the implants.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging and characterization of primary and secondary radiation in ion beam therapy

Imaging in ion beam therapy is an essential and increasingly significant tool for treatment planning and radiation and dose deposition verification. Efforts aim at providing precise radiation field characterization and online monitoring of radiation dose distribution. A review is given of the research and methodology of quantum-imaging, composition, spectral and directional characterization of the mixed-radiation fields in proton and light ion beam therapy developed by the IEAP CTU Prague and HIT Heidelberg group. Results include non-invasive imaging of dose deposition and primary beam online monitoring.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cognitive behavioural therapy targeting cardiac anxiety post-myocardial infarction: results from two sequential pilot studies

Abstract Aims Cardiac anxiety, which is cardiac-related fear and avoidance behaviours, is common following myocardial infarction (MI) and has been associated with increased risk for cardiovascular events. However, there are currently no treatments specifically designed to target cardiac anxiety. The aim of the two pilot studies was to evaluate an exposure-based cognitive behavioural therapy protocol (MI-CBT) targeting cardiac anxiety following MI, assessing feasibility, acceptability, and the intervention's potential for reducing cardiac anxiety and improving health-related quality of life (QoL). Methods and results A series of two sequential, uncontrolled pilot studies were conducted. In Pilot Study 1 (n = 15), MI-CBT was delivered via face-to-face videoconference, while Pilot Study 2 (n = 23) was delivered online. Patients with a history of MI (≥6 months before assessment, type 1 ST- or non-ST-segment elevation MI, and elevated cardiac anxiety as per clinical interview) were included. The interventions lasted 8 weeks and were therapist-led, with key components including exposure to cardiac-related symptoms and reduction of avoidance behaviours. Participants completed self-rated assessments, including the Cardiac Anxiety Questionnaire (CAQ) and the 12-Item Short Form Health Survey (SF-12), at baseline, post-treatment, and 6-month follow-up. Treatment adherence and satisfaction were high. Cognitive behavioural therapy led to a large reduction in cardiac anxiety, as measured by the CAQ (P < 0.001), and significant improvements in health-related QoL, as measured by the SF-12 (P < 0.001), in both pilot studies. Conclusion These studies suggest that exposure-based CBT is a feasible, acceptable, and promising approach to reduce cardiac anxiety and improve QoL following MI. A randomized controlled trial should be conducted to evaluate the efficacy of the intervention.

Johnsson, Amanda (ORCID:0009000862983934)↗