Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Static analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Experimental Investigation of Plume-Induced Flow Separation on the National Launch System 1 1/2-Stage Launch Vehicle

An experimental investigation of plume-induced flow separation on the National Launch System (NLS) 1 1/2-stage launch vehicle was done. This investigation resulted from concerns raised about the flow separation that was encountered on the Saturn 5. A large similarity exists between configurations and nominal trajectories. The study involved the use of solid plume simulators to simulate the base pressure encountered by the vehicle due to engine exhaust plumes at predetermined critical Mach numbers based on Saturn 5 flight plume effects. The solid plume was varied in location, resulting in a parametric study of base pressure effects on flow separation. In addition to the parametric study of arbitrary plume locations, the base pressure resulting from the nominal trajectory was tested. This analysis was accomplished through two wind tunnel tests run at NASA Marshall Space Flight Center's 14 x 14-inch Trisonic Wind Tunnel during 1992. The two tests were a static stability and a pressure test each using a 0.004-scale NLS 1 1/2-stage model. This study verified that flow separation is present at Mach 2.74 and 3.48 for predicted flight base pressures at nominal or higher levels. The flow separation at the predicted base pressure is only minor and should not be of great concern. It is not of the magnitude of the flow separation that was experienced on the Saturn 5. If the base pressure exceeds these nominal conditions, the flow separation can drastically increase, and is of concern.

Springer, A.↗

Stress Measurements on Blair High School Gymnasium: A Demonstration of Space Technology Transfer

This Report describes an actual demonstration of transfer to non-space use of technologies developed for space programs applications. Techniques used in assessing static and dynamic characteristics of the Blair High School gymnasium involved data acquisition by continuous scanning of strain gauge data acquired over a time of wide-temperature range, and analysis by a computer routine developed by Jet Propulsion Laboratory five years ago. The advantage of this method over conventional structural testing of uniquely designed structures was proved. More importantly, the process of demonstration was shown to be of great assistance to, and extension of, normal methods of disseminating information of new technologies. It is felt that significant benefit will derive from this improved mode oi concept transfer.

Kastel, Dean↗

Terra MODIS Sees Solar Eclipses: Analysis of Reflective Solar Band Response at Multiple Radiance Levels

The MODIS imaging spectroradiometer instruments on-board NASA's Terra and Aqua satellites have 20 reflective solar bands (RSB) covering a wavelength range from 400 to 2200 nm. Radiance is calculated from processing raw signals with background, temperature, and electronic contamination corrected. Measured gain is calibrated with a fully Sunlit solar diffuser (SD) at a stable radiance level, considering a slowly changing SD reflectance degradation. These measurements provide time-dependent gain adjustment factors, and the calibration assumes a linear response for each band and detector. Hence, an analysis of the dependence on different radiance levels is warranted. The MODIS design has no mechanism for varying radiance levels, except for an attenuator screen. However, it has been in static configuration for Terra since mid-2003. An external source of radiance attenuation can be utilized during solar eclipse events, while maintaining high stability and accuracy of solar calibration standards. Due to its long mission lifetime, Terra has seen several Sun-Moon near-conjunction events when it coincides with the orbit path where the SD is directly illuminated. As of August 2020, we have identified 7 viable partial solar eclipses in the Terra mission data. We will discuss several results of our study, including comparison of measured SD signal to predicted radiance reduction based on a solar disk radiance model; nominal and outlier behavior as a function of bands, detectors, and mirror-sides; and comparison with other data sets. Our main conclusion from this study is that there is no notable correlation of detector-dependent trend with radiance level for most RSB bands.

Terra↗

Energy Arbitrage: Comparison of Options for use with LWR Nuclear Power Plants

Arbitrage is the opportunistic buying and selling of a commodity during local pricing valleys and peaks respectively to maximize economic value. This report evaluates options for energy arbitrage integrated with existing light water reactor (LWR) nuclear power plants (NPPs) where nuclear energy could be stored in a variety of forms and later recovered to generate electrical power during periods when grid electricity demand and pricing are high. The forms of energy storage examined in this report include the potential value of batteries, hydrogen, and thermal energy storage for coupling with nuclear power. Various large demand response options are also analyzed, including the production of liquid nitrogen via air separation and liquefaction, liquefaction of hydrogen, compressed hydrogen, and the cryogenic capture of CO2. Demand response refers to dispatchable loads that can cycle up or down depending on-grid electricity demand to aid in balancing the grid. Large demand response options could dispatch to aid nuclear power stations in avoiding power turndowns by providing an alternate disposition for electrical energy by producing marketable products (e.g., liquid nitrogen, hydrogen, or captured CO2). Static conditions were chosen and analyzed in this report for each option. Dynamic operation or optimization of energy arbitrage or demand response are out of scope for this report. The analysis is based on storage systems with discharge capacities of 500 MW for which various durations of storage and costs of charging (electricity cost) are examined. While the value of thermal energy to an industrial user for flexible plant operations has been previously proven as a business case, this report evaluates costs of hydrogen energy storage and leading thermal energy storage options, and large demand response loads that could be integrated with LWRs in comparison to utility-scale battery storage for use of off-peak nuclear energy. Compilation of this information will be used by the Idaho National Laboratory (INL) RAVEN/HERON systems integration and economics tool to evaluate thermal energy dispatch to industrial users. Relative ranking of energy storage options was done using a levelized cost of storage (LCOS) metric which calculates a rough breakeven cost for the system, taking into account the capital and operating costs as well as the revenue from arbitrage. Table ES1 below shows the LCOS for each of the energy storage options considered. First, in the table, lithium iron (Fe) phosphate batteries are listed as the base case for comparison against the other options. Next is hydrogen storage where most of the hydrogen analyses assumed the hydrogen to be produced using solid oxide electrolytic cell (SOEC) high temperature steam electrolysis (HTSE). The others used existing models of polymer electrolyte membrane (PEM) low temperature electrolysis to produce hydrogen. HTSE performance parameters and costs were taken from existing INL models. Various means were assumed to convert the hydrogen to electricity, including PEM fuel cells (FCs) and a gas turbine mixed in a 30 vol% mixture with natural gas. Physical storage (pressure vessels) and geological storage (natural underground features) were used to store the hydrogen as noted. Geological storage is more economical, but the locations are limited because of the requirement for pre-existing geological formations that will support storage. Thermal energy storage (TES) options were also analyzed including electro-thermal energy storage (ETES) and four different liquid sensible heat TES storage media as noted (Hitec, Hitec XL, Therminol-66, and Dowtherm A). The ETES process considered was modified using existing public documentation on an Echogen process and uses a separate supercritical CO2 charge and discharge cycle with sand as the heat storage media.

25 ENERGY STORAGE↗

Idaho Wildfires II: Assessing the Relationship Between Drought Indicators and Wildfire Risk to Enhance Hazard Modeling and Inform Mitigation Planning

The western United States has experienced twenty years of increased and prolonged drought which have exacerbated wildfire hazards. These jeopardize population centers through increased risks to ecosystem services, local economies, and livelihoods. The Idaho Office of Emergency Management, Water Resources, and Department of Lands are seeking methods to dynamically monitor these conditions and update models that inform hazard mitigation planning and resource allocation. Towards this, these agencies partnered with NASA DEVELOP to produce drought-enhanced wildfire hazard models. Part of a two-term project, the two teams revised the state’s static wildfire hazard model with refined data layers and remotely-sensed data to reflect dynamic ecosystem responses to drought conditions and wildfire potential. Our team distinguished between rangeland and forestland ecosystems, and investigated relationships between drought metrics and vegetation condition using TerrSet Earth Trends Modeler. This analysis determined that total precipitation at a 5-month lag interval (r 2 = 0.72) along with the Evaporative Stress Index (r 2 = 0.69); and precipitation at a 5-month interval (r 2 = 0.42) were important drivers in rangeland and forestland, respectively. These driver variables were incorporated into a temporally dynamic wildfire hazard map. Our team used linear regression to correlate hazard ratings with wildfire frequency. For the year 2020, neither the enhanced hazard model (p < 0.10, r 2 = 0.01) nor the state’s static model (p < 0.05, r 2 = 0.03) were strongly correlated with actual wildfire frequency as they expressed an inverse relationship between wildfire hazard and frequency. This suggests wildfire occurrence is complex and not necessarily driven by the variables used.

Wildfire↗

Flight motor set 360L001 (STS-26R). (Reconstructed dynamic loads analysis)

A transient analysis was performed to correlate the predicted versus measured behavior of the Redesigned Solid Rocket Booster (RSRB) during Flight 360L001 (STS-26R) liftoff. Approximately 9 accelerometers, 152 strain gages, and 104 girth gages were bonded to the motors during this event. Prior to Flight 360L001, a finite element model of the RSRB was analyzed to predict the accelerations, strains, and displacements measured by this developmental flight instrumentation (DFI) within an order of magnitude. Subsequently, an analysis has been performed which uses actual Flight 360L001 liftoff loading conditions, and makes more precise predictions for the RSRB structural behavior. Essential information describing the analytical model, analytical techniques used, correlation of the predicted versus measured RSRB behavior, and conclusions, are presented. A detailed model of the RSRB was developed and correlated for use in analyzing the motor behavior during liftoff loading conditions. This finite element model, referred to as the RSRB global model, uses super-element techniques to model all components of the RSRB. The objective of the RSRB global model is to accurately predict deflections and gap openings in the field joints to an accuracy of approximately 0.001 inch. The model of the field joint component was correlated to Referee and Joint Environment Simulation (JES) tests. The accuracy of the assembled RSRB global model was validated by correlation to static-fire tests such DM-8, DM-9, QM-7, and QM-8. This validated RSRB global model was used to predict RSRB structural behavior and joint gap opening during Flight 360L001 liftoff. The results of a transient analysis of the RSRB global model with imposed liftoff loading conditions are presented. Rockwell used many gage measurements to reconstruct the load parameters which were imposed on the RSRB during the Flight 360L001 liftoff. Each load parameter, and its application, is described. Also presented are conclusions and recommendations based on the analysis of this load case and the resulting correlation between predicted and measured RSRB structural behavior.

Call, V. B.↗

Crossing the Streams – Sampler and the TemplateEngine [Slides]

This presentation discusses Sampler, which is a versatile UQ and parametric study tool that can be applied to any SCALE Sequence. Sampler can perturb any quantity in any SCALE input. Recent work at ORNL has developed new types of covariance data that allow Sampler UQ to be applied to nearly all SCALE applications, including reactor depletion, UNF fuel characterization, source term analysis, and decay heat calculation. In SCALE 6.2 releases, CE data in transport cannot be perturbed. Sampler was originally designed for stochastic sampling with any sequence within SCALE and Parametric capability added in SCALE 6.2.2. Sampler can be used for uncertainty quantification, including sample data in static or depletion calculations and sample inputs for uncertainties in compositions and dimensions. The SCALE TemplateEngine allows for expanding templates to full inputs and the combination provides a powerful UQ tool.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling of a Turbofan Engine with Ice Crystal Ingestion in the NASA Propulsion System Laboratory

The main focus of this study is to apply a computational tool for the flow analysis of the turbine engine that has been tested with ice crystal ingestion in the Propulsion Systems Laboratory (PSL) at NASA Glenn Research Center. The PSL has been used to test a highly instrumented Honeywell ALF502R-5A (LF11) turbofan engine at simulated altitude operating conditions. Test data analysis with an engine cycle code and a compressor flow code was conducted to determine the values of key icing parameters, that can indicate the risk of ice accretion, which can lead to engine rollback (un-commanded loss of engine thrust). The full engine aerothermodynamic performance was modeled with the Honeywell Customer Deck specifically created for the ALF502R-5A engine. The mean-line compressor flow analysis code, which includes a code that models the state of the ice crystal, was used to model the air flow through the fan-core and low pressure compressor. The results of the compressor flow analyses included calculations of the ice-water flow rate to air flow rate ratio (IWAR), the local static wet bulb temperature, and the particle melt ratio throughout the flow field. It was found that the assumed particle size had a large effect on the particle melt ratio, and on the local wet bulb temperature. In this study the particle size was varied parametrically to produce a non-zero calculated melt ratio in the exit guide vane (EGV) region of the low pressure compressor (LPC) for the data points that experienced a growth of blockage there, and a subsequent engine called rollback (CRB). At data points where the engine experienced a CRB having the lowest wet bulb temperature of 492 degrees Rankine at the EGV trailing edge, the smallest particle size that produced a non-zero melt ratio (between 3 percent - 4 percent) was on the order of 1 micron. This value of melt ratio was utilized as the target for all other subsequent data points analyzed, while the particle size was varied from 1 micron - 9.5 microns to achieve the target melt ratio. For data points that did not experience a CRB which had static wet bulb temperatures in the EGV region below 492 degrees Rankine, a non-zero melt ratio could not be achieved even with a 1 micron ice particle size. The highest value of static wet bulb temperature for data points that experienced engine CRB was 498 degrees Rankine with a particle size of 9.5 microns. Based on this study of the LF11 engine test data, the range of static wet bulb temperature at the EGV exit for engine CRB was in the narrow range of 492 degrees Rankine - 498 degrees Rankine , while the minimum value of IWAR was 0.002. The rate of blockage growth due to ice accretion and boundary layer growth was estimated by scaling from a known blockage growth rate that was determined in a previous study. These results obtained from the LF11 engine analysis formed the basis of a unique “icing wedge.”

Turbo engine↗

Simplified Analysis Of Shock Waves

Semiempirical expressions and conventional analyses agree within about 3 percent. Set of semiempirical formulas enables direct calculation of supersonic and hypersonic shock-wave parameters without use of iterative procedures. Formulas provided for calculating shock deflection angle and downstream static pressure and enthalpy over mach number range of 2 to 25. Relationship describing thermodynamic behavior of partially dissociated air also developed.

Neuenschwander, Wilmer E.↗

Analysis of shell-type structures subjected to time-dependent mechanical and thermal loading

The objective is to develop a general mathematical model and solution methodologies for analyzing structural response of thin, metallic shell-type structures under large transient, cyclic, or static thermomechanical loads. Among the system responses, which are associated with these load conditions, are thermal buckling, creep buckling, and racheting. Thus, geometric as well as material-type nonlinearities (of high order) can be anticipated and must be considered in the development of the mathematical model. Furthermore, this must also be accommodated in the solution procedures.

Simitses, G. J.↗

Formulation of an improved smeared stiffener theory for buckling analysis of grid-stiffened composite panels

A smeared stiffener theory for stiffened panels is presented that includes skin-stiffener interaction effects. The neutral surface profile of the skin-stiffener combination is developed analytically using the minimum potential energy principle and statics conditions. The skin-stiffener interaction is accounted for by computing the stiffness due to the stiffener and the skin in the skin-stiffener region about the neutral axis at the stiffener. Buckling load results for axially stiffened, orthogrid, and general grid-stiffened panels are obtained using the smeared stiffness combined with a Rayleigh-Ritz method and are compared with results from detailed finite element analyses.

Jaunky, Navin↗

Analysis of magnetic fields using variational principles and CELAS2 elements

Prospective techniques for analyzing magnetic fields using NASTRAN are reviewed. A variational principle utilizing a vector potential function is presented which has as its Euler equations, the required field equations and boundary conditions for static magnetic fields including current sources. The need for an addition to this variational principle of a constraint condition is discussed. Some results using the Lagrange multiplier method to apply the constraint and CELAS2 elements to simulate the matrices are given. Practical considerations of using large numbers of CELAS2 elements are discussed.

Frye, J. W.↗

Analysis of stability contributions of high dihedral V-tails

An investigation was undertaken to determine the effectiveness of four analytical methods (empirical, modified empirical, vortex-lattice, and an inviscid, three dimensional, potential flow, wing body program) to estimate the lateral and longitudinal static stability characteristics of an isolated V-tail wind tunnel model. The experimental tests were conducted in the V/STOL tunnel at a Mach number of 0.18. Angle-of-attack data were obtained from -12 deg to 8 deg at 0 deg sideslip. Sideslip sweeps from -5 deg to 10 deg were made at angles of attack of 4 deg, 0 deg and -4 deg. The V-tail dihedral angles were 45 deg, 50 deg, 55 deg, and 60 deg.

Freeman, C. E.↗

Dynamic Creep Buckling: Analysis of Shell Structures Subjected to Time-dependent Mechanical and Thermal Loading

The objective of the present research is to develop a general mathematical model and solution methodologies for analyzing the structural response of thin, metallic shell structures under large transient, cyclic, or static thermomechanical loads. Among the system responses associated with these loads and conditions are thermal buckling, creep buckling, and ratcheting. Thus geometric and material nonlinearities (of high order) can be anticipated and must be considered in developing the mathematical model. A complete, true ab-initio rate theory of kinematics and kinetics for continuum and curved thin structures, without any restriction on the magnitude of the strains or the deformations, was formulated. The time dependence and large strain behavior are incorporated through the introduction of the time rates of metric and curvature in two coordinate systems: fixed (spatial) and convected (material). The relations between the time derivative and the covariant derivative (gradient) were developed for curved space and motion, so the velocity components supply the connection between the equations of motion and the time rates of change of the metric and curvature tensors.

Simitses, G. J.↗

Analysis of shell-type structures subjected to time-dependent mechanical and thermal loading

This research is performed to develop a general mathematical model and solution methodologies for analyzing structural response of thin, metallic shell-type structures under large transient, cyclic or static thermomechanical loads. Among the system responses, which are associated with these load conditions, are thermal buckling, creep buckling, and ratcheting. Thus, geometric as well as material-type nonlinearities (of high order) can be anticipated and must be considered in the development of the mathematical model. Furthermore, this must also be accommodated in the solution procedures.

Simitses, G. J.↗

Analysis of shell-type structures subjected to time-dependent mechanical and thermal loading

This report deals with the development of a general mathematical model and solution methodology for analyzing the structural response of thin, metallic shell-like structures under dynamic and/or static thermomechanical loads. In the mathematical model, geometric as well as the material-type of nonlinearities are considered. Traditional as well as novel approaches are reported and detailed applications are presented in the appendices. The emphasis for the mathematical model, the related solution schemes, and the applications, is on thermal viscoelastic and viscoplastic phenomena, which can predict creep and ratchetting.

Simitses, G. J.↗

Analysis of Atmosphere-Ocean Surface Flux Feedbacks in Recent Satellite and Model Reanalysis Products

Recent investigations have examined observations in an attempt to determine when and how the ocean forces the atmosphere, and vice versa. These studies focus primarily on relationships between sea surface temperature anomalies and the turbulent and radiative surface heat fluxes. It has been found that both positive and negative feedbacks, which enhance or reduce sea surface temperature anomaly amplitudes, can be generated through changes in the surface boundary layer. Consequent changes in sea surface temperature act to change boundary layer characteristics through changes in static stability or turbulent fluxes. Previous studies over the global oceans have used coarse-resolution observational and model products such as ICOADS and the NCEP Reanalysis. This study focuses on documenting the atmosphere ocean feedbacks that exist in recently produced higher resolution products, namely the SeaFlux v1.0 product and the NASA Modern Era Retrospective-Analysis for Research and Applications (MERRA). It has been noted in recent studies that evidence of oceanic forcing of the atmosphere exists on smaller scales than the usually more dominant atmospheric forcing of the ocean, particularly in higher latitudes. It is expected that use of these higher resolution products will allow for a more comprehensive description of these small-scale ocean-atmosphere feedbacks. The SeaFlux intercomparisons have revealed large scatter between various surface flux climatologies. This study also investigates the uncertainty in surface flux feedbacks based on several of these recent satellite based climatologies

Roberts, J. Brent↗

ELASTIC INSTABILITY OF CONICAL SHELLS UNDER COMBINED LOADING

1. Criteria are presented for the elastic instability of thin single and multilayer conical and cylindrical shells under combined axial load and external pressure. These criteria, used in design analysis, are based on theoretical results and the correlation of these results with readily available experimental data. 2. A summary is included of the studies at Avco RAD of shells under static or dynamic loads.

ELASTIC SHELL↗