Adsorptive Transport of Noble Gas Tracers in Porous Media
The transport of noble gas radionuclides in porous media is relevant to the detection of underground nuclear detonations as well as the sequestration of reprocessing off-gases. However, in field tests releasing radioxenon underground, the quantity of radioxenon observed at the surface has fallen well below expectations1. This study examined the diffusivity of noble gases (Kr and Xe) and the inert molecular gas sulfur hexafluoride (SF6) in porous media to observe any unexpected behavior. To replicate the transport of radiogenic noble gases in underground media, a two-bulb gaseous diffusion apparatus was constructed. The two bulbs are connected with a column of 10-30 Ottawa sand and ordinary atmosphere filled both the bulbs and pore spaces. The tracer gases were diluted in an isolated bulb to approximately 1000 ppm. Once released, the gases were allowed to diffuse through the column. Aliquots were withdrawn at regular time intervals from both bulbs and concentrations were quantified using a Shimadzu QP2010 SE gas chromatograph-mass spectrometer. The effective diffusivity was then calculated using a maximum likelihood estimate on the quasi-steady state model.