Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Intimal smooth muscle cells are a source but not a sensor of anti-inflammatory CYP450 derived oxylipins

Vascular pathologies are associated with changes in the presence and expression of morphologically distinct vascular smooth muscle cells. In particular, in complex human vascular lesions and models of disease in pigs and rodents, an intimal smooth muscle cell (iSMC) which exhibits a stable epithelioid or rhomboid phenotype in culture is often found to be present in high numbers, and may represent the reemergence of a distinct developmental vascular smooth muscle cell phenotype. The CYP450-oxylipin - soluble epoxide hydrolase (sEH) pathway is currently of great interest in targeting for cardiovascular disease. sEH inhibitors limit the development of hypertension, diabetes, atherosclerosis and aneurysm formation in animal models. We have investigated the expression of CYP450-oxylipin-sEH pathway enzymes and their metabolites in paired intimal (iSMC) and medial (mSMC) cells isolated from rat aorta. iSMC basally released significantly larger amounts of epoxy-oxylipin CYP450 products from eicosapentaenoic acid > docosahexaenoic acid > arachidonic acid > linoleic acid, and expressed higher levels of CYP2C12, CYP2B1, but not CYP2J mRNA compared to mSMC. When stimulated with the pro-inflammatory TLR4 ligand LPS, epoxy-oxylipin production did not change greatly in iSMC. In contrast, LPS induced epoxy-oxylipin products in mSMC and induced CYP2J4. iSMC and mSMC express sEH which metabolizes primary epoxy-oxylipins to their dihydroxy-counterparts. The sEH inhibitors TPPU or AUDA inhibited LPS-induced NFκB activation and iNOS induction in mSMC, but had no effect on NFκB nuclear localization or inducible nitric oxide synthase in iSMC; effects which were recapitulated in part by addition of authentic epoxy-oxylipins. iSMCs are a rich source but not a sensor of anti-inflammatory epoxy-oxylipins. Complex lesions that contain high levels of iSMCs may be more resistant to the protective effects of sEH inhibitors. - Highlights: • We examined oxylipin production in different SMC phenotypes. • Intimal SMC produced more oxylipins than medial SMC. • CYPs were differentially expressed and regulated by LPS in intimal and medial SMC. • sEH inhibitors reduce inflammation in medial but not intimal SMC. • Intimal SMC are a source but not sensor of epoxy-oxylipins.

60 APPLIED LIFE SCIENCES↗

High-resolution wall temperature measurements with distributed fiber optic sensors

Conventional approaches of surface temperature measurement are often unreliable, and other methods may not be practical in closed, high-temperature spaces. In this study, surface temperature measurements of the cooling panel of a natural circulation facility were performed with fiber optic distributed temperature sensors (DTS). High resolution surface temperature profiles of the cooling panel were acquired under two steady experimental conditions, and compared with measurements performed with nearby thermocouples. The total measurement error of the DTS results presented has been estimated to be ±4.4 °C. The findings reflected herein show that these DTS can reasonably measure surface temperature when installed with the methods developed in this study. Through the analysis of the DTS data collected, the interesting behavior of the cooling panel was revealed, providing new insights on the system's behavior that may be beneficial to the design and optimization of such heat transfer devices. These sensors can also provide the measurement density necessary for validation efforts with highly-resolved prediction methods such as finite element analysis (FEA) or computational fluid dynamics (CFD).

47 OTHER INSTRUMENTATION↗

Enhanced H{sub 2}S gas sensing properties of multiple-networked Pd-doped SnO{sub 2}-core/ZnO-shell nanorod sensors

Pd-doped SnO{sub 2}-core/ZnO-shell nanorods were synthesized by using a three-step process: thermal evaporation of Sn powders in an oxygen atmosphere, atomic layer deposition of ZnO, and Pd diffusion followed by annealing. The sensitivity of the multiple networked SnO{sub 2}-core/ZnO-shell nanorod sensor to H{sub 2}S gas was found to be improved further significantly by Pd doping. The Pd-doped SnO{sub 2}-core/ZnO-shell nanorod sensor showed sensitivities of 6.4, 15.4, and 36.2% at H{sub 2}S concentrations of 20, 50, and 100 ppm at room temperature. The sensitivity of the nanorods was improved by more than 10 times at a H{sub 2}S concentration of 100 ppm. The sensitivity enhancement of the SnO{sub 2}-core/ZnO-shell nanorods by Pd doping may be attributed to the spillover effect, active reaction site generation, and the enhancement of chemisorption and dissociation of gas.

36 MATERIALS SCIENCE↗

Color-tunable luminescent Ln{sup 3+} composite as self-referencing and ratiometric sensor for low-level water detection in ethanol

Graphical abstract: A new color-tunable luminescent Ln{sup 3+} (Ln = Eu, Tb or Eu and Tb in different molar ratio) composite was prepared through a simple method, which can be applied as self-referencing and ratiometric sensor for detecting low-level water content (0.01-0.5 vol%) in ethanol. - Highlights: • A novel Ln{sup 3+} (Ln = Eu, Tb or Eu and Tb in different molar ratio) complex with tunable luminescence from red to green was prepared through a simple procedure. • The luminescence color of the Eu/Tb co-doped complex can be tuned by water through the luminescence quenching mechanism as well as the variation of energy transfer efficiency from Tb{sup 3+} to Eu{sup 3+}. • The complex with Eu{sup 3+}:Tb{sup 3+} = 1:1 can be applied as self-referencing and ratiometric luminescent sensor for detecting low-content water (0.01–0.5 vol%) in ethanol. - Abstract: Developing simple, fast and sensitive detection of low-level water in organic solvents is in high demand for academic and industrial applications. In this paper, a novel color-tunable lanthanide composite has been prepared by simply mixing 2,2':6',2”-terpyridine-4'-carboxylic acid (Hctpy) and Ln{sup 3+} with a molar ratio of 3:1 in absolute ethanol at room temperature, in which the Ln{sup 3+} ions are mainly coordinated with carboxyl moieties rather than with terpyridine moieties of Hctpy. In addition, the emission colors of the composite can also be tuned by water, ascribed to the luminescence quenching mechanism and the variation of Tb-to-Eu energy transfer efficiency. Based on these properties, a self-referencing and ratiometric luminescent water detector with the Eu/Tb molar ratio of 1:1 has been developed, showing proportional relationship between the intensity ratio of {sup 5}D{sub 0} → {sup 7}F{sub 2} transition of Eu{sup 3+} to {sup 5}D{sub 4} → {sup 7}F{sub 5} transition of Tb{sup 3+} (I{sub Eu}/I{sub Tb}) and the water concentration (0.01–0.5 vol%) in ethanol.

36 MATERIALS SCIENCE↗

Structural characterization of chitosan-smectite nanocomposite and its application in the development of a novel potentiometric monohydrogen phosphate-selective sensor

Highlights: • Protonated chitosan molecules intercalated into the smectite layers as monolayered arrangement. • A novel HPO{sub 4}{sup 2−} selective potentiometric electrode based on the chitosan-smectite nanocomposite was constructed. • Easy to prepare, low-cost, and highly selective potentiometric sensor. - Abstract: Chitosan-smectite biocomposite was prepared by intercalation of protonated chitosan molecules into the interlayer space of smectite in monolayer arrangement through cation exchange mechanism and the obtained biocomposite was successfully used as an electroactive component in the structure of a PVC membrane potentiometric sensor for the direct and highly selective determination of monohydrogen phosphate ions. The comparative elemental, structural, thermal and morphological analysis of starting-smectite, neat chitosan and chitosan-smectite were investigated by utilizing EDX, XRD, ATR-FTIR, TG/DTG/DTA, SEM and surface area measurement techniques. The optimum membrane composition, detection limit, response time, pH working range and repeatability of the proposed electrode were determined.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Synthesis of dual-emitting (Gd,Eu)2O3-PEI@CD composite and its potential as ratiometric fluorescent sensor for curcumin

Highlights: • Dual-emitting (Gd,Eu){sub 2}O{sub 3}-PEI@CD composite were synthesized. • Under UV irradiation, the composite exhibits both blue CD emission and red Eu{sup 3+} emission. • a novel self-referencing fluorescent sensor for curcumin was designed. • The limit of detection is 0.0615 μg/ml at the signal to noise ratio of 3. - Abstract: Carbon dots (CD)-coated (Gd,Eu){sub 2}O{sub 3}-PEI nanospheres were successfully prepared via a facile electrostatic absorption method. Under UV irradiation, the composite simultaneously exhibits both blue CD emission band and red Eu{sup 3+} emission peaks. It is found that blue CD emission could be quenched by curcumin, while red Eu{sup 3+} emission is hardly influenced. Thus, a novel self-referencing fluorescent sensor for curcumin with high sensitivity and superior signal discriminability was designed. The ratio of two emissions (F{sub 445}/F{sub 611}) shows good linear relationship with curcumin concentration (R{sup 2} = 0.9973). The limit of detection is determined to be 0.0615 μg/ml at the signal to noise ratio of 3. These attractive merits enable this composite in ratiometric sensing for medicines in the future.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A progressive electrochemical sensor for food quality control: Reliable determination of theobromine in chocolate products using a miniaturized boron-doped diamond electrode

In the present paper, a miniaturized boron-doped diamond electrode (BDDE) is proposed as a progressive electrochemical sensor for simple, fast and reliable quantification of dimethylxanthine alkaloid, theobromine (TB). Using cyclic voltammetry, the studied xanthine provided one well-shaped, irreversible and diffusion-controlled oxidation peak at relatively high potentials (+1.2 V vs. Ag/AgCl/3 M KCl reference electrode) in the presence of 0.1 M H2SO4. After selection of suitable experimental conditions, the linear calibration curves for TB were obtained in the concentration range from 0.99 up to 54.5 μM with the sensitivity of 0.07 μA/μM providing both differential pulse (DPV) and square-wave voltammetric (SWV) techniques, respectively. The elaborated voltammetric protocol yielded low detection limits of 0.42 and 0.51 μM accompanied by adequate intra-day repeatability (relative standard deviation of 2.5 and 1.7%) using DPV and SWV procedure, respectively. The interference study revealed the reasonable selectivity when taking the target food samples into account. The practical applicability of the voltammetric protocol using a miniaturized BDDE was verified in the analysis of six commercially available brands of chocolate products with the determined mass percentages of TB ranging from 0.75 to 2.24% and from 0.69 to 2.15% using DPV and SWV procedure, respectively. The obtained results were also in a good agreement with those achieved by reference titration method with potentiometric indication. The progressive electrochemical sensor based on a miniaturized BDDE has appeared to be an attractive candidate for practical applications in food quality control. Besides, the proposed voltammetric protocol presents advantages when compared to others techniques (e.g. chromatography), concerning simplicity, cost, speed of analysis, waste generation (environmentally friendly) and samples pretreatment (only dilution in electrolyte solution prior to analysis). © 2018 Elsevier B.V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Neutron Sensors and Their Role in Nuclear Nonproliferation

Perhaps the most familiar application of neutron detection technology to nonproliferation resides in materials accounting, where the quantification of plutonium has a rich history. With a changing dynamic in nuclear security, the application of sensor technology to further other nonproliferation objectives has received considerable attention. This fact, amplified by a dwindling supply of 3He, has stimulated considerable interest in neutron detection technology development for applications ranging from interdicting smuggled nuclear material to the verification of stockpile reductions. This manuscript briefly overviews the application of neutron sensors to nonproliferation and examines three specific examples that highlight the constraints applied to field-deployed technology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

On the timing performance of thin planar silicon sensors

We report on the signal timing capabilities of thin silicon sensors when traversed by multiple simultaneous minimum ionizing particles (MIP). Three different planar sensors, with depletion thicknesses 133, 211, and 285 µm, have been exposed to high energy muons and electrons at CERN. We describe signal shape and timing resolution measurements as well as the response of these devices as a function of the multiplicity of MIPs. We compare these measurements to simulations where possible. We achieve better than 20 ps timing resolution for signals larger than a few tens of MIPs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the polysilicon resistor in silicon strip sensors for ATLAS inner tracker as a function of temperature, pre- and post-irradiation

The high luminosity upgrade of the Large Hadron Collider, foreseen for 2029, requires the replacement of the ATLAS Inner Detector with a new all-silicon Inner Tracker (ITk). The expected ultimate total integrated luminosity of 4000 fb –1 means that the strip part of the ITk detector will be exposed to the total particle fluences and ionizing doses reaching the values of 1.6 · 10 15 1 MeV n eq /cm 2 and 0.66 MGy, respectively, including a safety factor of 1.5. Radiation hard n + -in-p micro-strip sensors were developed by the ATLAS ITk strip collaboration and are produced by Hamamatsu Photonics K.K. The active area of each ITk strip sensor is delimited by the n-implant bias ring, which is connected to each individual n + implant strip by a polysilicon bias resistor. The total resistance of the polysilicon bias resistor should be within a specified range to keep all the strips at the same potential, prevent the signal discharge through the grounded bias ring and avoid the readout noise increase. While the polysilicon is a ubiquitous semiconductor material, the fluence and temperature dependence of its resistance is not easily predictable, especially for the tracking detector with the operational temperature significantly below the values typical for commercial microelectronics. Dependence of the resistance of polysilicon bias resistor on the temperature, as well as on the total delivered fluence and ionizing dose, was studied on the specially-designed test structures called ATLAS Testchips, both before and after their irradiation by protons, neutrons, and gammas to the maximal expected fluence and ionizing dose. The resistance has an atypical negative temperature dependence. It is different from silicon, which shows that the grain boundary has a significant contribution to the resistance. Finally, we discuss the contributions by parameterizing the activation energy of the polysilicon resistance as a function of the temperature for unirradiated and irradiated ATLAS Testchips.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Horn Location Sensors for LBNF

The Horn Location Sensor (HLS) system—named for the magnetic focusing horns it monitors, along with other critical beamline elements – is a high-precision alignment system developed for the Long-Baseline Neutrino Facility (LBNF) to support the Deep Underground Neutrino Experiment (DUNE). With minimal maintenance, the HLS can operate reliably in environments with high radiation, and it ensures that key components such as the protective baffle, focusing horns, and beam position monitors are aligned correctly – each essential for maintaining one of the world’s most intense muon-neutrino beams. A high-precision hydrostatic level sensor, a linear variable differential transformer, and INVAR rods are all used in the system to monitor vertical motion and tilt with sub-millimeter accuracy. A novel Sweep Tracker interferometer enhances calibration fidelity by correcting for non-linearities in laser wavelength and scan rate in real time. A critical part of DUNE’s precision alignment and flux prediction requirements, the HLS system initially supports beam power of up to 1.2 MW and can be upgraded to 2.4 MW.

Frequency scanning interferometry↗

Digital phase demodulation for low-coherence interferometry-based fiber-optic sensors

In this paper, we describe a digital phase demodulation scheme for low-coherence interferometry-based fiber-optic sensors by employing a simple generation of phase-shifted signals at the interrogation interferometer. The scheme allows a real-time calibration process and offers capability of measuring large variations (up to the coherence of the light source) at the bandwidth that is only limited by the data acquisition system. Finally, the proposed phase demodulation method is analytically derived and its validity and performance are experimentally verified using fiber-optic Fabry–Perot sensors for measurement of strains and vibrations.

47 OTHER INSTRUMENTATION↗

Integrating fiber optic sensors into metallic components for sensing in harsh environments

The integration of fiber optic sensors into high-temperature materials is critical for real-time monitoring and autonomous operation of engineering systems. This study demonstrated a spark plasma sintering (SPS)-assisted embedding process for integrating sapphire fiber optic sensors into stainless steel components during part fabrication. Optical fibers were encapsulated in stainless steel 316L powders which were sintered at different fabrication conditions using SPS to investigate the effects of sintering parameters on the embedment. Measurements of optical transmittance, combined with microstructural analysis (X-ray computed tomography and scanning electron microscopy) and mechanical testing (tensile and microhardness), were conducted to examine the fiber functionality, fiber–matrix bonding quality, and properties of the sintered materials. Here, the results show that under suitable fabrication conditions, intact optical fibers can be encapsulated in highly-densified (>98 % relative density) stainless steel components. These conditions also led to a good bond at the fiber–matrix interface with micron-sized material interdiffusion across the interface. The sintering parameters were observed to affect fiber optical attenuation, where high temperature, pressure, and hold time during SPS enhanced fiber–matrix bonding and adversely affected optical transmission. Tensile testing confirmed the superior tensile strength and ductility of the matrix fabricated by SPS. Furthermore, the materials exhibited limited strength reduction (~70 MPa) upon the integration of fibers. This study demonstrates the effectiveness of SPS for fiber-material integration for high-temperature applications.

36 MATERIALS SCIENCE↗

Photostable and efficient upconverting nanocrystal-based chemical sensors

Chemical sensing in living systems demands optical sensors that are bright, stable, and sensitive to the rapid dynamics of chemical signaling. Lanthanide-doped upconverting nanoparticles (UCNPs) efficiently convert near infrared (NIR) light to higher energy emission and allow biological systems to be imaged with no measurable background or photobleaching, and with reduced scatter for subsurface experiments. Despite their advantages as imaging probes, UCNPs have little innate chemical sensing ability and require pairing with organic fluorophores to act as biosensors, although the design of stable UCNP-fluorophore hybrids with efficient upconverted energy transfer (UET) has remained a challenge. Here, we report Yb 3+ - and Er 3+ -doped UCNP-fluorophore conjugates with UET efficiencies up to 88%, and photostabilities 100-fold greater by UET excitation than those of the free fluorophores under direct excitation. Despite adding distance between Er 3+ donors and organic acceptors, thin inert shells significantly enhance overall emission without compromising UET efficiency. This can be explained by the large increase in quantum yield of Er 3+ donors at the core/shell interface and the large number of fluorophore acceptors at the surface. Sensors excited by UET show increases in photostability well beyond those reported for other methods for increasing the longevity of organic fluorophores, and those covalently attached to UCNP surface polymers show greater chemical stability than those directly coordinated to the nanocrystal surface. Furthermore by conjugating other fluorescent chemosensors to UCNPs, these hybrids may be extended to a series of NIR-responsive biosensors for quantifying the dynamic chemical populations critical for cell signaling.

36 MATERIALS SCIENCE↗

An Invisible Bend Sensor Based on Porous Crosslinked Polyelectrolyte Film

This paper describes the fabrication of a porous cross-linked polyelectrolyte membrane and the characterization of its humidity sensitivity performance. Electrostatic self-assembly, combined with acid treatment, and post-deposition annealing produced the membrane. The fabrication process offers the ability to control the thickness of the membrane, as well as enabling the engineering of the humidity sensitivity properties. A transparent humidity sensor was fabricated by integrating the membrane into a capacitive structure. In order to improve the moisture absorption and diffusion, both the polyelectrolyte layer and the electrode were made porous. The membrane was cross-linked to enhance the durability in high humid environments. Such a polyelectrolyte membrane showed high sensitivity to relative humidity variation over a range of 25-99%. The see-through property of the structure adds extra features and benefits to the sensor.

47 OTHER INSTRUMENTATION↗

Potentiometric Sensors Based on Surface Molecular Imprinting: Detection of Cancer Biomarkers and Viruses

The continuing discovery of cancer biomarkers necessitates improved methods for their detection. Molecular imprinting using artificial materials provides an alternative to the detection of a wide range of substances. We applied surface molecular imprinting using self-assembled monolayers to design sensing elements for the detection of cancer biomarkers and other proteins. These elements consist of a gold-coated silicon chip onto which hydroxyl-terminated alkanethiol molecules and template biomolecule are co-adsorbed, where the thiol molecules are chemically bound to the metal substrate and self-assembled into highly ordered monolayers, the biomolecules can be removed, creating the foot-print cavities in the monolayer matrix for this kind of template molecules. Re-adsorption of the biomolecules to the sensing chip changes its potential, which can be measured potentiometrically. We applied this method to the detection of carcinoembryonic antigen (CEA) in both solutions of purified CEA and in the culture medium of a CEA-producing human colon cancer cell line. The CEA assay, validated also against a standard immunoassay, was both sensitive (detection range 2.5-250 ng/mL) and specific (no cross-reactivity with hemoglobin; no response by a non-imprinted sensor). Similar results were obtained for human amylase. In addition, we detected virions of poliovirus in a specific manner (no cross-reactivity to adenovirus, no response by a non-imprinted sensor). Our findings demonstrate the application of the principles of molecular imprinting to the development of a new method for the detection of protein cancer biomarkers and to protein-based macromolecular structures such as the capsid of a virion. This approach has the potential of generating a general assay methodology that could be highly sensitive, specific, simple and likely inexpensive.

59 BASIC BIOLOGICAL SCIENCES↗

A colorimetric sensor based on anodized aluminum oxide (AAO) substrate for the detection of nitroaromatics.

Simple and low cost colorimetric sensors for explosives detection were explored and developed. Anodized aluminum oxide (AAO) with large surface area through its porous structure and light background color was utilized as the substrate for colorimetric sensors. Fabricated thin AAO films with thickness less than {approx} 500 nm allowed us to observe interference colors which were used as the background color for colorimetric detection. AAO thin films with various thickness and pore-to-pore distance were prepared through anodizing aluminum foils at different voltages and times in dilute sulfuric acid. Various interference colors were observed on these samples due to their difference in structures. Accordingly, suitable anodization conditions that produce AAO samples with desired light background colors for optical applications were obtained. Thin film interference model was applied to analyze the UV-vis reflectance spectra and to estimate the thickness of the AAO membranes. We found that the thickness of produced AAO films increased linearly with anodization time in sulfuric acid. In addition, the growth rate was higher for AAO anodized using higher voltages. The thin film interference formulism was further validated with a well established layer by layer deposition technique. Coating poly(styrene sulfonate) sodium salt (PSS) and poly(allylamine hydrochloride) (PAH) layer by layer on AAO thin film consistently shifted its surface color toward red due to the increase in thickness. The red shift of UV-vis reflectance was correlated quantitatively to the number of layers been assembled. This sensitive red shift due to molecular attachment (increase in thickness) on AAO substrate was applied toward nitroaromatics detection. Aminopropyltrimethoxysilane (APTS) which can be attached onto AAO nanowells covalently through silanization and attract TNT molecules was coated and applied for TNT detection. UV-vis spectra of AAO with APTS shifted to the longer wavelength side due to TNT attachment. This red shift implied AAO thickness increased and positive detection of TNT molecules. It was also observed that both APTS and polyethyleneimine (PEI) were electron rich polymers which formed Meisenheimer complexes with TNT in solution and changed its color abruptly. This strong color change due to chemical reaction was applied as another approach for direct TNT detection. Commercial AAO films with long pores (60 {mu}m) and white background color were coated with APTS or PEI and then exposed to TNT in solution. These membranes turned to pink rapidly and eventually became visibly orange after a few hours with a strong absorption around 500 nm that was consistent with the formation of Meisenheimer complexes. The visible color change can be observed by unaided eyes and is suitable for nitroaromatics detection at higher concentration while interference color red shift in AAO thin film is designed for nitroaromatics detection at monolayer (nm) level.

36 MATERIALS SCIENCE↗

Improving the sensitivity of electrochemical sensors through a complementary luminescent mode: A new spectroelectrochemical approach

Rapid and sensitive detection and quantification of trace and ultra-trace analytes is critical to environmental remediation, analytical chemistry and defense from chemical and biological contaminants. While affinity based electrochemical sensors have gained immense popularity, they occasionally are not able to meet the requirements of desired sensitivity and detection limits. Here, we demonstrate a complementary luminescence mode that can significantly enhance sensitivity of impedance or voltammetric electrochemical sensors. Our methodology involves using a redox probe, whose luminescence properties change upon changing the oxidation state. By tailoring the system such that these luminescence changes can be correlated with the capture of target analytes, we are able to significantly lower the detection limit and improve efficiency of detection compared to the electrochemical modes alone. Our proof-of-concept demonstration using a model system designed for Ca2+ capture, illustrated that the luminescent mode allowed us to lower the limits of detection by 3-orders of magnitude compared to the impedance or voltammetric modes alone without requiring any modification of electrode design or cell configuration.

environmental sensor, electrochemistry, affinity, ↗