Tracking source movements using distributed detectors.
No abstract prepared.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract prepared.
This presentation is for the national Radionuclide NESHAP meeting, an embedded topic of the 2012 Health Physics Society Annual Meeting in Sacramento, CA. The Radionuclide NESHAP program is responsible for measuring and reporting the amount of airborne radioactive material released from DOE facilities. The issue at hand is recent guidance put forth by the Department of Energy regarding threshold limits for Category 3 and Category 2 nuclear facilities. Updates to calculation methods have resulted in increased amounts of radioactive material allowed in inventory for facilities before they reach levels which require them to be categorized as a Category 2 or 3 nuclear facility. With larger radioactive material inventories, there may be a corresponding increase in overall facility emissions. This can have permitting and monitoring impacts for DOE sites, as well as political ramifications with citizen organizations. This presentation is intended to raise awareness of the new guidance and associated issues, and to stimulate discussion among DOE Radionuclide NESHAP representatives.
We present a diagnostics suite and analyze techniques for setting up the longitudinal beam dynamics in ILC e⁻ injectors and e⁺ and e⁻ bunch compressors. Techniques to measure the first order moments and recover the first order longitudinal transfer map of the injector's intricate bunching scheme are presented. Coherent transition radiation diagnostics needed to measure and monitor the bunch length downstream of the ~5 GeV bunch compressor are investigated using a vector diffraction model.
This Final Report refers to the project “Development of Thermoacoustic Sensors for Sodium-cooled Fast Reactor Systems”, which was led by Westinghouse Electric Company (Westinghouse) and carried out in collaboration with Argonne National Laboratory (ANL) and University of Pittsburgh. Thermo-acoustic Power Sensors (TAPS) are self-powered, wireless sensors envisioned for measuring key parameters, such as local temperature and neutron flux, in a nuclear reactor core. This project was intended to specifically investigate their applicability to Sodium-cooled Fast Reactors (SFR). TAPS are non-invasive (wireless) and passive (self-powered) devices. The passivity derives from their ability to use conditions that “naturally” exist in a nuclear reactor, such as gamma and neutron flux, as power sources. They generate oscillating pressure waves (i.e., sound waves) which, with a frequency and amplitude dependent upon these conditions, can travel through the core and associated structures, and reach the outside of the reactor vessel where a properly designed network of receivers can detect and interpret them. These receivers require a very small amount of power which, during loss of power events, can be provided for example by harvesting gamma radiation energy, thus resulting in a monitoring system that can function both during normal operation and during loss of power events. The project aimed at TAPS development through a series of tasks which are listed and briefly discussed as follows. TASK 1 – Sensor hardware design Subtask 1a: Assessment of sensor applications to SFRs Subtask 1b: Development of sensor functional requirements Subtask 1c: Definition of sensor hardware design specifications Task description: TAPS design was informed by considerations on their application (Subtask 1a), both the ultimate one in an SFR and the actual one in the ANL testing facilities that was intended to be used in support of the project. Considerations were made to identify optimum sensor design features that optimize the sensor size, materials, and output signal, for installation inside an SFR core. These considerations led to the development of Functional Requirements (Subtask 1b) and Design Requirements (Subtask 1c). TASK 2 – Sensor Hardware Manufacture Subtask 2a: Sensor hardware construction drawing development Subtask 2b: Sensor manufacture and assembly Task description: TAPS technical drawings were developed (Subtask 2a) using the Design Requirements established under Task 1. Subsequently, in spite of some problems which ultimately caused the program to be delayed, TAPS manufacturing was completed based on drawings (Subtask 2b). TASK 3 – Development of TAPS Signal Measurement System and TAPS Testing in Water Subtask 3a: Design, assembly and testing of signal measurement system, and TAPS testing in water Subtask 3b: Signal prediction-correction methodology development Task description: An assessment was performed on the techniques that can potentially be used to detect the signals emitted by the TAPS, e.g. a fiber-optic based acoustic signal measurement system, a laser vibrometer system, or an accelerometer-based system. The most suited technology, i.e. the accelerometer-based system, was developed further, and tested in water (Subtask 3a). Moreover, efforts were made to develop the methodology required to determine the actual system temperature and neutron flux distribution using differences between the measured and predicted TAPS responses (Subtask 3b). TASK 4 – Sensor System Testing in Sodium Subtask 4a: Test plan development Subtask 4b: Design, assembly and testing in small-scale sodium facility Subtask 4c: Design, assembly and testing in large-scale sodium and structures facility Task description: Upon proper test plan development (Subtask 4a), the fabricated TAPS was planned to be tested in sodium, by using two sodium facilities at ANL having different size and different purpose. The Under Sodium Viewing (USV) small-scale facility was intended to be used to investigate the effect of sodium on the sensor and its performance (Subtask 4b). The Mechanism Engineering Test Loop (METL) large-scale facility was instead intended to be used to assess the additional effect of prototypical SFR structures, such as fuel assembly mockup or parts of the core restrain structure, on sensor performance (Subtask 4c). As discussed in Section 3.2.2.7, unexpected issues during the TAPS manufacturing process resulted in some activities being delayed, with the TAPS and USV facility developed to the point to be ready for testing in sodium, however without the possibility to actually perform such testing (including the testing in METL) due to the end of the program’s performance period. Overall, through the development and testing (in water only) of two TAPS devices (a First-Generation TAPS followed by an optimized Second-Generation TAPS), the project confirmed the capability of this technology to generate acoustic signals proportional to temperature, which can be detected through a network of accelerometers identified as the best-suited type of receivers for acoustic signal detection. Moreover, the project also developed a computational model to predict the characteristics of the acoustic signals being generated, which combines thermal analysis of the TAPS with Finite Element Modeling (FEM)-aided acoustic characterization of the system. This model was benchmarked against experimental data collected during the project and, although general agreement was obtained, some limitations of the modeling methods were identified, which require additional development. Additional testing is needed in order to assess the effect, on TAPS operation and performance, of environmental changes resulting from the transition from water to liquid sodium. Such testing, which is suggested to be performed in the future, should look specifically at 1) both the effect resulting from the different thermoacoustic behavior of sodium (relative to water) and the effects of higher temperature on TAPS performance, and 2) the performance of the sensor-receiver system when multiple TAPS are used simultaneously and prototypical reactor structures are positioned in the testing environment. The latter testing is needed to assess the effects that potential signal attenuation/ distortion phenomena, as well as potential interference between signals emitted simultaneously, have on the performance of the technology for ultimate application in a nuclear reactor.
Transition radiation from nanotubes, nanosheets, and nanoparticles and in particular, boron nitride nanomaterials, can be utilized for the generation of light. Wavelengths of light of interest for microchip lithography, including 13.5 nm (91.8 eV) and 6.7 nm (185 eV), can be generated at useful intensities, by transition radiation light sources. Light useful for monitoring relativistic charged particle beam characteristics such as spatial distribution and intensity can be generated.
On-line radioactivity monitoring in liquid effluents is an increasing need according to the international regulations at present. Classical activity determination procedures include the sequence of sampling, chemical treatment, measurement and data treatment. These steps are man-power consuming, generate a great amount of waste and introduce an important delay between the potential pollution event and its detection and quantification. To overcome these limitations, we have developed a radiochemical sensor for liquid effluents capable of sending information about the specific activity and volume of a contamination episode to a remote position, on line and continuously. The capabilities of the sensor developed here allow detecting and quantifying contamination pulses of alpha, beta and gamma emitters of different volumes and activity levels included in a continuous stream. Sensor receptor includes two detection systems, one addressed to determine alpha, beta and gamma events and the other to detect sample gamma emissions. Detailed sensor structure will be shown at the conference because patent is in process at this moment. Detection efficiencies (%) obtained in the alpha-beta-gamma system for the range of contamination volumes considered (2- 300 ml) are: 1.6 - 3.2%, for Pu-240; 22.2 - 58.4%, for Sr-90/Y-90 and 8.8 -17.7%, for Cs-134. In the gamma system, values for Cs-134 detection range from 0.6% to 1.3%. Prediction errors obtained show that sensor is capable to detect Sr-90/Y-90 contamination pulses of at least 2 ml and 3 Bq/ml with a relative error lower of 10% in activity and 60% in volume. When contamination pulse increases up to 7 ml, relative errors decrease to 5% for both magnitudes. For Pu-240 and Cs-134, when contamination pulses are of at least 7 ml and 300 Bq/ml, the relative errors obtained in determinations performed in the alpha-beta-gamma system are lower than 10% in activity and 20 % in volume. The same errors are obtained in the gamma system for Cs-134 when contamination pulses are higher than 7 ml and activities up to 1300 Bq/ml. (authors)
Plutonium contaminated (TRU) wastes arising during decommissioning and waste retrievals operations at a UK reprocessing facility include small process items, strippable coatings, size-reduced pieces of glove box and metal pipes, etc. These waste materials are generally assayed in a 'Piece Monitor' employing neutron coincidence counting and gamma assay technologies. The major function of the TRU D{sup R} Piece Monitor is to provide an accurate assay of the TRU content of waste pieces/packages, primarily for nuclear safety purposes. The Piece Monitor follows each waste measurement by calculating the cumulative plutonium content of a waste drum as it is filled with this waste, allowing maximum filling of the drum whilst ensuring it remains within fissile content limits. TRU Piece Monitors are deployed at the interface between clean-air (C2) and the active decommissioning (C5) areas by attaching them to the wall of removable modular containment structures (MCSs). In the C5 area, the plant operator uses a variety of cold-cutting processes to size-reduce plant equipment and then places waste items in the monitor chamber for assay, prior to placing the waste in a 200 litre drum. The 're-entrant bulge' design of the assay chamber provides access from the active operations side, whilst the detection equipment remains in the C2 area. This ensures that the Piece Monitor equipment does not become contaminated and remains readily accessible for maintenance or repair. Piece monitors measure and report the plutonium content of each waste item immediately prior to placing in the waste drum, and provides a continuous 'tally' of the drum content. Warnings are shown when a drum is close to exceeding its allowable plutonium content and the waste drum can therefore be changed when either physically full or nearing its nuclear safety limits. (authors)
Estimates as well as subsequent measurements of the radiation released following the events at the Fukushima Daiichi Nuclear Power Plant in March 2011 place the incident as the second greatest nuclear event to have ever occurred - duly rated at the maximum of Level 7 on the INES Event Scale. The releases of radioactivity from the plant were detected worldwide, however the multi-reactor nature of the events at the FDNPP has complicated the understanding of the radionuclide release inventory and the subsequent distribution of the material. As a result of this highly-complex release scenario, it is important to understand the current and evolving state of contamination within the rapidly evolving, topographically extreme and frequently typhoon impacted environment on Japan's eastern coast. Existing systems rely either on high-altitude manned aircraft to perform such contamination surveys, correcting results to ground-level, or, on humans manually measuring the dose-rate on foot. In order to overcome the shortcomings of both methods, a low-altitude unmanned aerial vehicle (UAV) has been developed at the University of Bristol and successfully deployed to the affected areas surrounding the FDNPP. In contrast to these other methods; the use of low-altitude UAVs provides a spatial resolution previously achievable only through the deployment of humans on the ground, with the potential for significant radiation exposure. This high-resolution monitoring allows for subsequent modelling to inform our understanding of the behaviour and long-term stability of the fallout material. (authors)
The Chalk River Laboratories (CRL) began nuclear operations in 1947. Beginning in 1952 after the NRX accident, the management of excess contaminated liquids from the accident, and later in 1953, other waste liquids, were intermittently dispersed to trenches and pits in the local sand. The local sands proved effective at immobilization of actinides, and most activation and fission products. However there was very limited retention of some more commonly mobile radionuclides. Sand filtration performance and radionuclide migration was studied beginning in 1952. Monitoring data indicated slow migration of most radioactive contaminants away from the trenches and pits due to the adsorbing capacity of the sand substrate. The radionuclide migration continues to be studied today in frequent plume monitoring studies. Because many hard-to measure (HTM) radionuclides may also present as long term dose contributors in post remediation scenarios, or in disposal site performance assessments, the quantification of these HTM radionuclides is important. The use of scaling factors between HTM radionuclides and easy-to-measure (ETM) radionuclides (gamma emitters) for packaged soil wastes would alleviate significant effort in sampling individual waste containers. As part of plume monitoring studies and the environmental remediation process, significant characterization of soils have been performed at the site. The soil sample data from multiple historic waste management areas across site is combined and relationships between HTM radionuclides and ETM or key radionuclides are examined. Additional (secondary) relationships between ETM key nuclides are also explored to evaluate secondary scaling relationships between ETM key radionuclides (e.g., Co- 60/Cs-137), because of the significant decay of the activation product key radionuclide Co-60, (predominantly 10-20 half-lives). The evaluation is yielding consistent scaling factors for legacy soil wastes in the historic waste management areas. Given the hydrogeology of the site, a sandy shallow unconfined aquifer, and the annual precipitation of about 0.85 m/a, this evaluation reveals some expected relationships between fission products and actinides and some unanticipated relationships between more mobile radionuclides and key gamma emitters. (authors)
An overview of the Fissile Material Monitor Waste Screener (FMM-WS) System is presented. This system is a multifunctional radioactive waste assay system suitable for the rapid assay of highly contaminated transuranic wastes immediately after retrieval, prior to packaging. The FMM-WS was developed for use at the Accelerated Cleanup Project (ARP) and began initial testing and operation in April 2008. The FMM-WS is currently in use and is providing needed data on transuranic (TRU) wastes with a range of material types, volumes, and densities from the Accelerated Retrieval Project (ARP).
The objective of this Plant Directed Research and Demonstration (PDRD) task was to develop a system to safetly analyze tritium in moisture collected from glovebox atmospheres in the Savannah River Site (SRS) Tritium Facility. In order to minimize potential radiation exposures that could occur in handling and diluting high-tritium-content water, SRS sought alternatives to liquid-scintillation counting. The proposed system determines tritium concentrations by measuring Bremsstrahlung radiation induced by low-energy beta interactions in liquid samples. Results show that, after a short counting period (30 seconds), detection limits are three orders of magnitude below the described concentration of tritiated water in the zeolite beds. Additionally, this report covers the analysis of process samples and the investigation of several cell window materials including beryllium, aluminum, and copper. Final tests reveal that alternate window materials and thicknesses can be used to obtain useful results. In particular, a window of stainless steel of moderate thickness (0.3 cm) can be used for counting relatively high levels of tritium.
The ALTEA project investigates the risks of functional brain damage induced by particle radiation in space. A modular facility (the ALTEA facility) is being implemented and will be operated in the International Space Station (ISS) to record electrophysiological and behavioral descriptors of brain function and to monitor their time dynamics and correlation with particles and space environment. The focus of the program will be on abnormal visual perceptions (often reported as "light flashes" by astronauts) and the impact on retinal and brain visual structures of particle in microgravity conditions. The facility will be made available to the international scientific community for human neurophysiological, electrophysiological and psychophysics experiments, studies on particle fluxes, and dosimetry. A precursor of ALTEA (the 'Alteino' project) helps set the experimental baseline for the ALTEA experiments, while providing novel information on the radiation environment onboard the ISS and on the brain electrophysiology of the astronauts during orbital flights. Alteino was flown to the ISS on the Soyuz TM34 as part of mission Marco Polo. Controlled ground experiments using mice and accelerator beams complete the experimental strategy of ALTEA. We present here the status of progress of the ALTEA project and preliminary results of the Alteino study on brain dynamics, particle fluxes and abnormal visual perceptions. c2004 COSPAR. Published by Elsevier Ltd. All rights reserved.
In 2009 the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Center started free electron laser (FEL) operation. In order to continue to produce the bright and short-pulsed x-ray laser demanded by FEL scientists, this pioneer hard x-ray FEL requires a perfectly tailored magnetic field at the undulators, so that the photons generated at the electron wiggling path interact at the right phase with the electron beam. In such a precise system, small (>0.01%) radiation-induced alterations of the magnetic field in the permanent magnets could affect FEL performance. This paper describes the simulation studies of radiation fields in permanent magnets and the expected signal in the detectors. The transport of particles from the radiation sources (i.e. diagnostic insert) to the undulator magnets and to the beam loss monitors (BLM) was simulated with the intra nuclear cascade codes FLUKA and MARS15. In order to accurately reproduce the optics of LCLS, lattice capabilities and magnetic fields were enabled in FLUKA and betatron oscillations were validated against reference data. All electron events entering the BLMs were printed in data files. The paper also introduces the Radioactive Ion Beam Optimizer (RIBO) Monte Carlo 3-D code, which was used to read from the event files, to compute Cerenkov production and then to simulate the optical coupling of the BLM detectors, accounting for the transmission of light through the quartz.
Purpose: To evaluate, using real-time monitoring of implanted radiofrequency transponders, the intrafraction prostate displacement of patients as a function of body mass index (BMI). Methods and Materials: The motions of Beacon radiofrequency transponders (Calypso Medical Technologies, Seattle, WA) implanted in the prostate glands of 66 men were monitored throughout the course of intensity modulated radiation therapy. Data were acquired at 10 Hz from setup to the end of treatment, but only the 1.7 million data points with a 'beam on' tag were used in the analysis. There were 21 obese patients, with BMI {>=}30 and 45 nonobese patients in the study. Results: Mean displacements were least in the left-right lateral direction (0.56 {+-} 0.24 mm) and approximately twice that magnitude in the superior-inferior and anterior-posterior directions. The net vector displacement was larger still, 1.95 {+-} 0.47 mm. Stratified by BMI cohort, the mean displacements per patient in the 3 Cartesian axes as well as the net vector for patients with BMI {>=}30 were slightly less (<0.2 mm) but not significantly different than the corresponding values for patients with lower BMIs. As a surrogate for the magnitude of oscillatory noise, the standard deviation for displacements in all measured planes showed no significant differences in the prostate positional variability between the lower and higher BMI groups. Histograms of prostate displacements showed a lower frequency of large displacements in obese patients, and there were no significant differences in short-term and long-term velocity distributions. Conclusions: After patients were positioned accurately using implanted radiofrequency transponders, the intrafractional displacements in the lateral, superior-inferior, and anterior-posterior directions as well as the net vector displacements were smaller, but not significantly so, for obese men than for those with lower BMI.
Optical thin films designed for multispectral band-pass filters and a primary Ag mirror were deposited on radiation-resistant glass by ion-beam-assisted deposition. The filters and mirror are for use in the optical payload of a remote sensing instrument. The optical parameters of the films and mirror were optimized by using admittance loci analysis. The simulation shows that the band-pass filters can achieve average transmittances of 95% in the blue (B1), green (B2), red (B3), near-infrared (B4), and panchromatic (400-900 nm) spectral ranges and an average reflectance of 99% for the primary Ag mirror in the visible spectrum. The corresponding properties of the films were investigated by in situ optical monitoring, spectrometry, and high-resolution transmission electron microscopy. It was found that the average transmittances are above 85% for all five band-pass filters, with a rejection transmittance below 1% in the spectral range of 350-1100 nm. The average reflectance of the primary Ag mirror (with a protective coating) is above 98%. Interference coatings were added to the basic protected silver design to enhance the reflectance in the visible spectral range. Furthermore, to investigate the optical stability of optical thin films for aerospace applications, a space environment was simulated by using a Co{sup 60} gamma ({gamma}) radiation source (total doses of 35 krad and 1 Mrad). The experimental results indicate that both the dielectric thin film stacks and radiation-protected glass are resistant to {gamma} radiation in the simulated space environment.
The Remote Sensing Laboratory’s (RSL) Aerial Measuring System (AMS) is one of the emergency response assets belonging to the U.S. Department of Energy (DOE) National Nuclear Security Administration (NNSA). The AMS is used to detect, measure, and track radioactive material before and during emergencies to locate sources or determine contamination levels. Since September 11, 2001, increasing numbers of local, state, and federal entities have developed aerial radiation detection capabilities. NNSA has recognized a need by these entities for an AMS Reachback Center that would provide training and assistance on all aspects of AMS. The Center will assist local, state, and federal agencies in establishing the skills, resources, and training needed for a successful AMS regional operation. Beginning in January 2008, and continuing through April 2008, a pilot program was created in collaboration between NNSA and the U.S. Department of Homeland Security’s Domestic Nuclear Detection Office (DNDO). The purpose of this collaboration was to provide aerial radiological surveillance and equipment technique training to local law enforcement offices in four major U.S. cities: Chicago, Washington DC, New York, and Los Angeles. The Mobile Aerial Radiological Surveillance (MARS) training curriculum was jointly developed by NNSA and DNDO headquarters and NNSA support teams. A total of 44 students participated in the training events held during this period. The positive reaction to this program has led to the establishment of the RSL as the headquarters for the National Aerial Measuring System Reachback (NAMSR) Center. The NAMSR Center will provide an AMS Home Team stand-by duty team for local, state, and federal agencies to discuss, plan, and analyze available data for aerial responses. An additional role of the Center will be to serve as the source of subject matter experts (SME) for the training of newly established aerial radiological monitoring assets. The purpose of this paper is to review the history, success, and future plans of the National AMS Reachback Center.
A succinct history of the Confined Atom problem is presented. The hydrogen atom confined to the centre of an impenetrable sphere counts amongst the exactly soluble problems of physics, alongside much more noted exact solutions such as Black Body Radiation and the free Hydrogen atom in absence of any radiation field. It shares with them the disadvantage of being an idealisation, while at the same time encapsulating in a simple way particular aspects of physical reality. The problem was first formulated by Sommerfeld and Welker - henceforth cited as SW - in connection with the behaviour of atoms at very high pressures, and the solution was published on the occasion of Pauli's 60th birthday celebration. At the time, it seemed that there was not much other connection with physical reality beyond a few simple aspects connected to the properties of atoms in solids, for which more appropriate models were soon developed. Thus, confined atoms attracted little attention until the advent of the metallofullerene, which provided the first example of a confined atom with properties quite closely related to those originally considered by SW. Since then, the problem has received much more attention, and many more new features of quantum confinement, quantum compression, the quantum Faraday cage, electronic reorganisation, cavity resonances, etc have been described, which are relevant to real systems. Also, a number of other situations have been uncovered experimentally to which quantum confinement is relevant. Thus, studies of the confined atom are now more numerous, and have been extended both in terms of the models used and the systems to which they can be applied. Connections to thermodynamics are explored through the properties of a confined two-level atom adapted from Einstein's celebrated model, and issues of dynamical screening of electromagnetic radiation by the confining shell are discussed in connection with the Faraday cage produced by a confining conducting shell. The conclusions are shown to be relevant to a proposed 'quantum computer'. The description of the actual geometry of C{sub 60}, as opposed to a purely spherical approximation, leads to some qualification of the computed results.
In this work we present the development of an acquisition system for characterizing transistors under X-ray radiation. The system is able to carry out the acquisition and to storage characteristic transistor curves. To test the acquisition system we have submitted polarized P channel MOS transistors under continuous 10-keV X-ray doses up to 1500 krad. The characterization system can operate in the saturation region or in the linear region in order to observe the behavior of the currents or voltages involved during the irradiation process. Initial tests consisted of placing the device under test (DUT) in front of the X-ray beam direction, while its drain current was constantly monitored through the prototype generated in this work, the data are stored continuously and system behavior was monitored during the test. In order to observe the behavior of the DUT during the radiation tests, we used an acquisition system that consists of an ultra-low consumption16-bit Texas Instruments MSP430 microprocessor. Preliminary results indicate linear behavior of the voltage as a function of the exposure time and fast recovery. These features may be favorable to use this device as a radiation dosimeter to monitor low rate X-ray.