Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Diboson Physics at CDF

At the Fermilab Tevatron, the CDF detector is used to study diboson production in pp-bar collisions at sq root(s) = 1.96 TeV. We report recent diboson production measurements, limits on anomalous triple gauge couplings and latest results from semi-leptonic diboson searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evidence for a Narrow Near-Threshold Structure in the J/psiphi Mass Spectrum in B{sup +}->J/psiphiK{sup +} Decays

Evidence is reported for a narrow structure near the J/psiphi threshold in exclusive B{sup +}->J/psiphiK{sup +} decays produced in pp collisions at sq root(s)=1.96 TeV. A signal of 14+-5 events, with statistical significance in excess of 3.8 standard deviations, is observed in a data sample corresponding to an integrated luminosity of 2.7 fb{sup -1}, collected by the CDF II detector. The mass and natural width of the structure are measured to be 4143.0+-2.9(stat)+-1.2(syst) MeV/c{sup 2} and 11.7{sub -5.0}{sup +8.3}(stat)+-3.7(syst) MeV/c{sup 2}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of b Hadron Lifetimes in Exclusive Decays Containing a J/{psi} in pp Collisions at {radical}(s)=1.96 TeV

We report on a measurement of b-hadron lifetimes in the fully reconstructed decay modes B{sup +}{yields}J/{psi}K{sup +}, B{sup 0}{yields}J/{psi}K{sup *}(892){sup 0}, B{sup 0}{yields}J/{psi}K{sub s}{sup 0}, and {Lambda}{sub b}{sup 0}{yields}J/{psi}{Lambda}{sup 0} using data corresponding to an integrated luminosity of 4.3 fb{sup -1}, collected by the CDF II detector at the Fermilab Tevatron. The measured lifetimes are {tau}(B{sup +})=[1.639{+-}0.009(stat){+-}0.009(syst)] ps, {tau}(B{sup 0})=[1.507{+-}0.010(stat){+-}0.008(syst)] ps, and {tau}({Lambda}{sub b}{sup 0})=[1.537{+-}0.045(stat){+-}0.014(syst)] ps. The lifetime ratios are {tau}(B{sup +})/{tau}(B{sup 0})=[1.088{+-}0.009(stat){+-}0.004(syst)] and {tau}({Lambda}{sub b}{sup 0})/{tau}(B{sup 0})=[1.020{+-}0.030(stat){+-}0.008(syst)]. These are the most precise determinations of these quantities from a single experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-E-I-49: Simulation Study for Removing Scatter Radiation in Cesium-Iodine Based Flat Panel Detector System

Purpose: This study aims to identify the feasibility of a novel cesium-iodine (CsI)-based flat-panel detector (FPD) for removing scatter radiation in diagnostic radiology. Methods: The indirect FPD comprises three layers: a substrate, scintillation, and thin-film-transistor (TFT) layer. The TFT layer has a matrix structure with pixels. There are ineffective dimensions on the TFT layer, such as the voltage and data lines; therefore, we devised a new FPD system having net-like lead in the substrate layer, matching the ineffective area, to block the scatter radiation so that only primary X-rays could reach the effective dimension.To evaluate the performance of this new FPD system, we conducted a Monte Carlo simulation using MCNPX 2.6.0 software. Scatter fractions (SFs) were acquired using no grid, a parallel grid (8:1 grid ratio), and the new system, and the performances were compared.Two systems having different thicknesses of lead in the substrate layer—10 and 20μm—were simulated. Additionally, we examined the effects of different pixel sizes (153×153 and 163×163μm) on the image quality, while keeping the effective area of pixels constant (143×143μm). Results: In case of 10μm lead, the SFs of the new system (∼11%) were lower than those of the other system (∼27% with no grid, ∼16% with parallel grid) at 40kV. However, as the tube voltage increased, the SF of new system (∼19%) was higher than that of parallel grid (∼18%) at 120kV. In the case of 20μm lead, the SFs of the new system were lower than those of the other systems at all ranges of the tube voltage (40–120kV). Conclusion: The novel CsI-based FPD system for removing scatter radiation is feasible for improving the image contrast but must be optimized with respect to the lead thickness, considering the system’s purposes and the ranges of the tube voltage in diagnostic radiology. This study was supported by a grant(K1422651) from Institute of Health Science, Korea University.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of a Mylar filter to eliminate vacuum ultraviolet pulse pileup in low-energy x-ray measurements

We describe a method to reduce vacuum ultraviolet (VUV) pulse pileup (PPU) in x-ray pulse-height Silicon Drift Detector (SDD) signals. An Amptek FAST SDD, with C1 (Si 3 N 4 ) window, measures bremsstrahlung emitted from PFRC-2 plasma to extract the electron temperature (T e ) and density (n e ). The C1 window has low transmissivity for photons with energy below 200 eV though will transmit some VUV and soft x-ray photons, which PFRC-2 plasmas abundantly emit. Multi-VUV-photon PPU contaminates the interpretation of x rays with energy > 100 eV, particularly in a low-energy exponential tail. The predicted low transmissivity of ~1 μm thick Mylar [polyethylene terephthalate (PET)] to photons of energy <100 eV led to the selection of Mylar as the candidate filter to reduce VUV PPU. Experiments were conducted on an x-ray tube with a graphite target and on a quasi-Maxwellian tenuous plasma (n e ~ 10 9 cm –3 ) with effective temperatures reaching 1500 eV. A Mylar filter thickness of 850 nm is consistent with the results. The Mylar-filter-equipped SDD was then used on the PFRC-2 plasma, showing a substantial reduction in the low-energy x-ray signal, supporting our hypothesis of the importance of VUV PPU. Here, we describe the modeling and experiments performed to characterize the effect of the Mylar filter on SDD measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Multidirectional Cosmic Ray Ion Detector for Deep Space CubeSats

NASA Glenn Research Center has proposed a CubeSat-based instrument to study solar and cosmic ray ions in lunar orbit or deep space. The objective of Solar Proton Anisotropy and Galactic cosmic ray High Energy Transport Instrument (SPAGHETI) is to provide multi-directional ion data to further understand anisotropies in SEP and GCR flux.

Extraterrestrial Radiation↗

Nanocomposite scintillator and detector

A nanocomposite scintillator is prepared using fast, bright, rare-earth doped nanopowder phosphor and a binder that is transparent to the emission of the phosphor.

36 MATERIALS SCIENCE↗

Searches for Heavy Vector Bosons at CDF

The existence of additional vector bosons are theoretically well motivated, arising naturally in many extensions of the Standard Model. Experimentally, such particles typically have clean signatures and therefore should be observed in hadron colliders if they are produced. We review recent searches for heavy vector bosons with CDF at the Tevatron and provide limits on their production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Neutrino induced coherent pion production

We discuss different parameterizations of the C{sub 5}{sup A}(q{sup 2}) NDELTA form factor, fitted to the old Argonne bubble chamber data for pion production by neutrinos, and we use coherent pion production to test their low q{sup 2} behavior. We find moderate effects that will be difficult to observe with the accuracy of present experiments. We also discuss the use of the Rein-Sehgal model for low energy coherent pion production. By comparison to a microscopic calculation, we show the weaknesses some of the approximations in that model that lead to very large cross sections as well as to the wrong shapes for differential ones. Finally we show that models based on the partial conservation of the axial current hypothesis are not fully reliable for differential cross sections that depend on the angle formed by the pion and the incident neutrino.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of branching fraction ratios and CP asymmetries in B{sup {+-}{yields}D}{sub CP}K{sup {+-}}decays in hadron collisions

We reconstruct B{sup {+-}{yields}D}K{sup {+-}}decays in a data sample collected by the CDF II detector at the Tevatron collider corresponding to 1 fb{sup -1} of integrated luminosity. We select decay modes where the D meson decays to either K{sup -{pi}+} (flavor eigenstate) or K{sup -}K{sup +}, {pi}{sup -{pi}+} (CP-even eigenstates), and measure the direct CP asymmetry A{sub CP+}=0.39{+-}0.17(stat){+-}0.04(syst), and the double ratio of CP-even to flavor eigenstate branching fractions R{sub CP+}=1.30{+-}0.24(stat){+-}0.12(syst). These measurements will improve the determination of the Cabibbo-Kobayashi-Maskawa angle {gamma}. They are performed here for the first time using data from hadron collisions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Forward-backward asymmetry of top quark pair production

We adopt a Markov chain Monte Carlo method to examine various new physics models which can generate the forward-backward asymmetry in top quark pair production observed at the Tevatron by the CDF Collaboration. We study the following new physics models: (1) exotic gluon G{sup '}, (2) extra Z{sup '} boson with flavor-conserving interaction, (3) extra Z{sup '} with flavor-violating u-t-Z{sup '} interaction, (4) extra W{sup '} with flavor-violating d-t-W{sup '} interaction, and (5) extra scalars S and S{sup {+-}}with flavor-violating u-t-S and d-t-S{sup {+-}}interactions. After combining the forward-backward asymmetry with the measurement of the top pair production cross section and the tt invariant mass distribution at the Tevatron, we find that an axial vector exotic gluon G{sup '} of mass about 1 TeV or 2 TeV or a W{sup '} of mass about 2TeV offer an improvement over the standard model. The other models considered do not fit the data significantly better than the standard model. We also emphasize a few points that have been long ignored in the literature for new physics searches: (1) heavy resonance width effects, (2) renormalization scale dependence, and (3) next-to-leading order corrections to the tt invariant mass spectrum. We argue that these three effects are crucial to test or exclude new physics effects in the top quark pair asymmetry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First Observation of B{sub s}{sup 0}->D{sub s}{sup +}-K{sup +}- and Measurement of the Ratio of Branching Fractions B(B{sub s}{sup 0}->D{sub s}{sup +}-K{sup +}-)/B(B{sub s}{sup 0}->D{sub s}{sup +}pi{sup -})

A combined mass and particle identification fit is used to make the first observation of the decay B{sub s}{sup 0}->D{sub s}{sup +}-K{sup +}- and measure the branching fraction of B{sub s}{sup 0}->D{sub s}{sup +}-K{sup +}- relative to B{sub s}{sup 0}->D{sub s}{sup +}pi{sup -}. This analysis uses 1.2 fb{sup -1} integrated luminosity of pp collisions at sq root(s)=1.96 TeV collected with the CDF II detector at the Fermilab Tevatron collider. We observe a B{sub s}{sup 0}->D{sub s}{sup +}-K{sup +}- signal with a statistical significance of 8.1sigma and measure B(B{sub s}{sup 0}->D{sub s}{sup +}-K{sup +}-)/B(B{sub s}{sup 0}->D{sub s}{sup +}pi{sup -})=0.097+-0.018(stat)+-0.009(syst).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low Temperature Magnetic Calorimeters For Neutrino Mass Direct Measurement

In the last years the mixing of the three neutrino flavor eigenstates through a unitary matrix has been experimentally proved. Presently one of the greatest challenges in neutrino physics is to establish the absolute value of the masses of the three neutrino mass eigenstates. The kinematic determination of electron neutrino and antineutrino mass by means of the analysis of calorimetric spectra of isotopes which undergo a beta or electron-capture decay, with especially low energy available for the decay itself, represents an interesting method. In fact this method is less affected by theoretical models defining branching ratio among different decay modes. For the beta decay the isotope with the lowest Q-value present in nature is the {sup 187}Re(Q about 2.5 keV) while for the electron capture decay the best candidate known is the {sup 163}Ho(Q about 2.5 keV). Since those experiments need to be extremely precise, they might suffer from unexpected systematic errors. It is therefore important to investigate in detail the performance of the detectors and the calorimetric spectrum. We present our results obtained with low temperature magnetic calorimeters designed for measuring low energy beta and electron capture spectra. We also discuss problematic and the possibly present systematic uncertainties using this kind of detectors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical Resonators in Current and Future Experiments of the ALPS Collaboration

The ALPS collaboration runs a 'light shining through a wall' (LSW) experiment to search for weakly interacting sub-eV particles (WISPs). Its sensitivity is significantly enhanced by the incorporation of a large-scale production resonator and a small-scale high-power resonant second harmonic generator. Here we report on important experimental details and limitations of these resonators and derive recommendations for further experiments. A very promising improvement for a future ALPS experiment is the incorporation of an additional large-scale regeneration resonator. We present a rough sketch of how to combine a regeneration resonator with a single-photon counter (SPC) as detector for regenerated photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A bolometer based on single-walled carbon nanotubes and hybrid materials

We have designed a bolometric IR detector based on freestanding aerosol synthesised carbon nanotubes and hybrid graphene materials deposited on a film suspended over a hole in the substrate. In this case, graphene serves as an absorber. The effect of the amount of the deposited absorber on the spectral characteristics, voltage sensitivity, response time and noise of the bolometer is investigated. The best response time is observed for the samples of pristine carbon nanotubes, whereas the hybrid sample with the largest amount of graphene demonstrates the highest sensitivity to radiation. Moreover, we have measured and analysed the bolometer parameters as functions of the ambient pressure and temperature, which has allowed us to determine the optimum operating conditions for the device. (paper)

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Study of a Narrow {pi}{sup +{pi}-} Peak at about 755 MeV/c{sup 2} in p-barn{yields}2{pi}{sup +}3{pi}{sup -} Annihilation at Rest

A narrow peak in the {pi}{sup +{pi}-} mass distribution was seen by the Rome-Syracuse Collaboration in p-barn{yields}2{pi}{sup +}3{pi}{sup -} annihilation at rest in 1970. It was ignored for 40 years. The reanalysis of this peak finds that it has the mass 757.4{+-}2.8{sub stat{+-}}1.2{sub sys} MeV/c{sup 2} and a width consistent with the experimental resolution. The evidence of the peak is 5.2 standard deviations. The peak is generated in (1.03{+-}0.21{sub stat{+-}}0.21{sub sys})% of the p-barn annihilations at rest. No spin analysis is possible with the statistics of the experiment but there are arguments suggesting that it has J{sup p} = 0{sup +}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects and Challenges for a Large Water Cherenkov Detector for LBNE

The Long Baseline Neutrino Experiment (LBNE) is a proposed experiment that would send a beam of muon neutrinos from Fermilab to the DUSEL (Deep Underground Science and Engineering Laboratory) facility in South Dakota, a 1300 km baseline. One possible configuration for the far detector is one or more large water Cherenkov modules with a fiducial mass of at least 100 kilotons each. The prospects and challenges of such a detector, including the current design, will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗