Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUALITY FACTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Manufacturing process modeling for composite materials and structures, Sandia blade reliability collaborative

The increased use and interest in wind energy over the last few years has necessitated an increase in the manufacturing of wind turbine blades. This increase in manufacturing has in many ways out stepped the current understanding of not only the materials used but also the manufacturing methods used to construct composite laminates. The goal of this study is to develop a list of process parameters which influence the quality of composite laminates manufactured using vacuum assisted resin transfer molding and to evaluate how they influence laminate quality. Known to be primary factors for the manufacturing process are resin flow rate and vacuum pressure. An incorrect balance of these parameters will often cause porosity or voids in laminates that ultimately degrade the strength of the composite. Fiber waviness has also been seen as a major contributor to failures in wind turbine blades and is often the effect of mishandling during the lay-up process. Based on laboratory tests conducted, a relationship between these parameters and laminate quality has been established which will be a valuable tool in developing best practices and standard procedures for the manufacture of wind turbine blade composites.

Guest, Daniel A.↗

Development of microchannel plate x-ray optics

The goal of this research program was to develop a novel technique for focusing x-rays based on the optical system of a lobster's eye. A lobster eye employs many closely packed reflecting surfaces arranged within a spherical or cylindrical shell. These optics have two unique properties: they have unlimited fields of view and can be manufactured via replication of identical structures. Because the angular resolution is given by the ratio of the size of the individual optical elements to the focal length, optical elements with sizes on the order of one hundred microns are required to achieve good angular resolution with a compact telescope. We employed anisotropic etching of single crystal silicon wafers for the fabrication of micron-scale optical elements. This technique, commonly referred to as silicon micromachining, is based on silicon fabrication techniques developed by the microelectronics industry. An anisotropic etchant is a chemical which etches certain silicon crystal planes much more rapidly than others. Using wafers in which the slowly etched crystal planes are aligned perpendicularly to the wafer surface, it is possible to etch a pattern completely through a wafer with very little distortion. Our optics consist of rectangular pores etched completely through group of zone axes (110) oriented silicon wafers. The larger surfaces of the pores (the mirror elements) were aligned with the group of zone axes (111) planes of the crystal perpendicular to the wafer surface. We have succeeded in producing silicon lenses with a geometry suitable for 1-d focusing x-ray optics. These lenses have an aspect ratio (40:1) suitable for x-ray reflection and have very good optical surface alignment. We have developed a number of process refinements which improved the quality of the lens geometry and the repeatability of the etch process. A significant progress was made in obtaining good optical surface quality. The RMS roughness was decreased from 110 A for our initial lenses to 30 A in the final lenses. A further factor of three improvement in surface quality is required for the production of efficient x-ray optics. In addition to the silicon fabrication, an x-ray beam line was constructed at Columbia for testing the optics.

Kaaret, Philip↗

Evaluation of GPS Coverage for the X-33 Michael-6 Trajectory

The onboard navigational system for the X-33 test flights will be based on the use of measurements collected from the Embedded Global Positioning System (GPS)/INS system. Some of the factors which will affect the quality of the GPS contribution to the navigational solution will be the number of pseudorange measurements collected at any instant in time, the distribution of the GPS satellites within the field of view, and the inherent noise level of the GPS receiver. The distribution of GPS satellites within the field of view of the receiver's antenna will depend on the receiver's position, the time of day, pointing direction of the antenna, and the effective cone angle of the antenna. The number of pseudorange measurements collected will depend upon these factors as well as the time required to lock onto a GPS satellite signal once the GPS satellite comes into the field of view of the antenna and the number of available receiver channels. The objective of this study is to evaluate the GPS coverage resulting from the proposed antenna pointing directions, the proposed antenna cone angles, and the effects due to the time of day for the X-33 Michael-6 trajectory from launch at Edwards AFB, California, to the start of the Terminal Area Energy Management (TAEM) phase on approach to Michael AAF, Utah.

Lundberg, John B.↗

The associations between environmental quality and preterm birth in the United States, 2000–2005: a cross-sectional analysis

Many environmental factors have been independently associated with preterm birth (PTB). However, exposure is not isolated to a single environmental factor, but rather to many positive and negative factors that co-occur. Furthermore, the environmental quality index (EQI), a measure of cumulative environmental exposure across all US counties from 2000—2005, was used to investigate associations between ambient environment and PTB.

54 ENVIRONMENTAL SCIENCES↗

Environmental health program in NASA

The NASA policy on environmental health uses medical and environmental concepts to: (1) Determine the health status of employees; (2) prevent illness and promote good health among employees; and (3) identify and control factors that affect the health of personnel and quality of environment. Evaluation and control of physical, chemical, radiological and biological factors surrounding personnel and which represent physiological and psychological stresses and impairment are considered.

Marrazzo, R. M.↗

Radiological data consolidation and 3D modeling of a building - 15473

A portion of a building at an industrial facility that conducted monazite sands-processing operations in the 1950's under contract to the Atomic Energy Commission (AEC) became contaminated. Subsequently the U.S. Department of Energy designated the facility for remedial action under the Formerly Used Sites Remedial Action Program (FUSRAP). Remedial investigation, remedial actions and post-remediation surveys have been conducted in portions of the building. Radiological data for the interior of the building were compiled, evaluated and presented in a three dimensional (3-D) model (the model) created by AMEC Foster Wheeler in order to identify areas that meet the Record of Decision (ROD) cleanup criteria, and identity areas that may require remedial action or may require additional investigation due to data gaps. The data from different phases of investigation and remediation cover different portions of the building and in some cases overlap. In addition, the data were collected over a period of more than ten years, for different objectives, and thus the instruments and methods for establishing efficiency were not necessarily consistent. The data consolidation process included determining the relative quality of data points to include in the model and the development of rationale associated with assigning a quality level (i.e. ranking) to each data point. The rationale for ranking data quality included, as the primary determining factors, chronological order of the data (most recent was ranked as more reliable), certainty of the sample locations within the building, and analytical data quality. A 3-D model of the building was created using a laser point cloud scan which was then converted into a 3-D design model. Sample locations were then entered into the model and linked with the analytical database to allow display of the radiological results in the model. The visual model allows both strategic and tactical decisions to be made, depending on the level of detail examined. The evaluation process allowed maximum use of the historical data set, rather than requiring older data to be disregarded, and provided at a minimum a qualitative sense of data quality/confidence in the data. The (authors)process also highlights the importance of collecting high quality data from the very beginning with a consistent locational coordinate system, and the need for a good visualization model in order to assess contaminant locations during remedial action or post-remediation surveys.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Strain-Driven Evolution of Structural and Carrier Recombination Dynamics in Germanium

Strain engineering in group-IV semiconductors, in particular germanium (Ge), offers a promising route for advancing next-generation optoelectronic device performance. High minority carrier lifetime serves as a direct indicator of superior material quality and device efficiency. Several factors govern the minority carrier lifetime in both strained Ge and strained GeSn, such as strain level, epilayer thickness, defects, surface roughness, and Sn alloying. In this study, the impact of biaxial strain on effective minority carrier lifetimes of tensile-strained Ge (0% ..epsilon..-Ge/Al?As, 0.78% ..epsilon..-Ge/In0.115?Ga0.885?As, and 0.93% ..epsilon..-Ge/In0.16?Ga0.84?As) and compressively strained GeSn (-0.53% c-Ge0.97?Sn0.03/Al?As) epilayers, grown by molecular beam epitaxy, was experimentally investigated via the microwave-reflection photoconductive decay (..mu..-PCD) technique as a simultaneous function of thickness and strain. The structural and strain-relaxation properties were analyzed by high-resolution x-ray diffraction and Raman spectroscopy, while surface morphology analysis using atomic force microscopy provided insights into the surface roughness of strained Ge-based epilayers. Defect characterization by cross-section transmission electron microscopy revealed superior crystalline quality of ..epsilon..-Ge in one epilayer, while twin boundary formation was observed in the other. We investigated the carrier recombination dynamics in epitaxially strained Ge by extracting the bulk recombination lifetime and surface recombination velocity using the thickness-dependent minority carrier lifetime. High effective minority carrier lifetimes of approximately 60-340 ns were achieved at high strain levels with minimal dependence on the thickness of the strained Ge-based epilayers by means of the ..mu..-PCD technique. Minority carrier lifetimes in Ge-based epilayers exhibit a quadratic dependence on the biaxial strain, ranging from -0.88% (compressive) to +1.6% (tensile). The analysis of the carrier recombination dynamics in strained Ge-based heterostructures offers a pathway to designing group-IV based optoelectronic devices.

36 MATERIALS SCIENCE↗

Characterization of the LTC catalyst: Performance against common air pollutants

One of the important qualities of the Low-Temperature Catalyst (LTC) is the rapid oxidation of carbon monoxide to carbon dioxide under a wide variety of conditions. The catalytic material is a palladium-copper activated complex which reacts with various contaminant molecules through a continuous oxidation/reduction cycle. The alumina substrate enhances LTC activity with its favorable surface chemistry and very high surface area. About 10 percent surface water is necessary to facilitate the oxidation of CO. This reaction shows a log-log dependence on contact time, suggesting a Langmuir-Hinshelwood mechanism. In the tube tests, LTC removed 90 to 100 percent of contaminating carbon monoxide in the temperature region of 20 to 4000 C, and at ambient over a range of 25 to 65 percent relative humidity. In contrast, NO2 is chemisorbed by the LTC/alumina material--the amount strongly dependent on temperature increases but independent of humidity. The LTC catalyst has demonstrated excellent capability to remove an important variety of hazardous pollutant gases which are common factors to poor indoor air quality. The Instapure Air Filtration System incorporates the LTC catalyst in a 50:50 mixture with activated carbon to effectively remove particulate, odors, and hazardous gases at room temperature and humidities. The ability to remove hazardous gases is unique for the category of portable air filtration equipment. The wide variety of pollutant gases that LTC removes suggests that catalytic technology is adaptable to a considerable range of commercial and industrial applications.

Collins, Marcia F.↗

Using naturally occurring radionuclides to determine drinking water age in a community water system

Drinking water quality in a community water system is closely linked to the age of water from initial treatment to time of delivery. However, water age is difficult to measure with conventional chemical tracers; particularly in stagnant water, where the relationship between disinfectant decay, microbial growth, and water age is poorly understood. Using radionuclides that were naturally present in source water, we found that measured activity ratios of 90 Y/ 90 Sr and 234 Th/ 238 U in discrete drinking water samples of known age accurately estimated water age up to 9 days old (σ est : ± 3.8 h, P < 0.0001, r 2 = 0.998, n = 11) and 25 days old (σ est : ± 13.3 h, P < 0.0001, r 2 = 0.996, n = 12), respectively. Moreover, 90 Y-derived water ages in a community water system (6.8 × 10 4 m 3 d –1 capacity) were generally consistent with water ages derived from an extended period simulation model. Radionuclides differ from conventional chemical tracers in that they are ubiquitous in distribution mains and connected premise plumbing. The ability to measure both water age and an analyte (e.g., chemical or microbe) in any water sample at any time allows for new insight into factors that control drinking water quality.

54 ENVIRONMENTAL SCIENCES↗

Systematic sequencing of chloroplast transcript termini from Arabidopsis thaliana reveals >200 transcription initiation sites and the extensive imprints of RNA-binding proteins and secondary structures

Abstract Chloroplast transcription requires numerous quality control steps to generate the complex but selective mixture of accumulating RNAs. To gain insight into how this RNA diversity is achieved and regulated, we systematically mapped transcript ends by developing a protocol called Terminome-seq. Using Arabidopsis thaliana as a model, we catalogued >215 primary 5′ ends corresponding to transcription start sites (TSS), as well as 1628 processed 5′ ends and 1299 3′ ends. While most termini were found in intergenic regions, numerous abundant termini were also found within coding regions and introns, including several major TSS at unexpected locations. A consistent feature was the clustering of both 5′ and 3′ ends, contrasting with the prevailing description of discrete 5′ termini, suggesting an imprecision of the transcription and/or RNA processing machinery. Numerous termini correlated with the extremities of small RNA footprints or predicted stem-loop structures, in agreement with the model of passive RNA protection. Terminome-seq was also implemented for pnp1–1, a mutant lacking the processing enzyme polynucleotide phosphorylase. Nearly 2000 termini were altered in pnp1–1, revealing a dominant role in shaping the transcriptome. In summary, Terminome-seq permits precise delineation of the roles and regulation of the many factors involved in organellar transcriptome quality control.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Can acceptable quality angel food cakes be made using pasteurized shell eggs? The effects of mixing factors on functional properties of angel food cakes

Due to recent Salmonella outbreaks, the pasteurized shell egg market is rapidly growing. One objection to using pasteurized eggs is the belief that they will produce unacceptable angel food cakes. Eggs were pasteurized using a hot water immersion process (56.7°C for 60 min) similar to that used by industry. Angel food cakes were made from the pasteurized egg white (PEW) as well as from raw egg white (REW) for comparison. Meringues were made using three mixer speed settings (low, medium, and high) and three durations for each speed. Functional qualities such as egg foaming were evaluated. Angel food cakes were compared in terms of cake volume, texture profile, and color values. When the optimal processing factors used for REW were applied to PEW, an inferior meringue was formed. However, by increasing the mixing time for PEW by 200% at the highest speed, an acceptable meringue was formed. The best angel food cake prepared from PEW had a volume only 6.8% less than that of the best cake prepared from REW. Texture profile analyses showed that the best angel food cake made from PEW was 13% firmer, 7.4% less springy, and 62% chewier than that from REW. Color analyses showed that PEW made a slightly darker colored cake crust than REW, although there were no significant differences in the crumb color. Modifying the mixing conditions for PEW resulted in angel food cakes with quality similar to that of cakes made with REW, thus overcoming an objection to using safer pasteurized shell eggs.

Food Science & Technology↗

Automatic selection of tube potential for radiation dose reduction in CT: A general strategy

Purpose: To optimize radiation dose efficiency in CT while maintaining image quality, it is important to select the optimal tube potential. The selection of optimal tube potential, however, is highly dependent on patient size and diagnostic task. The purpose of this work was to develop a general strategy that allows for automatic tube potential selection for each individual patient and each diagnostic task. Methods: The authors propose a general strategy that allows automatic adaptation of the tube potential as a function of patient size and diagnostic task, using a novel index of image quality, ''iodine contrast to noise ratio with a noise constraint (iCNR{sub N}C),'' to characterize the different image quality requirements by various clinical applications. The relative dose factor (RDF) at each tube potential to achieve a target image quality was then determined as a function of patient size and the noise constraint parameter. A workflow was developed to automatically identify the optimal tube potential that is both dose efficient and practically feasible, incorporating patient size and diagnostic task. An experimental study using a series of semianthropomorphic thoracic phantoms was used to demonstrate how the proposed general strategy can be implemented and how the radiation dose reduction achievable by the tube potential selection depends on phantom sizes and noise constraint parameters. Results: The proposed strategy provides a flexible and quantitative way to select the optimal tube potential based on the patient size and diagnostic task. The noise constraint parameter {alpha} can be adapted for different clinical applications. For example, {alpha}=1 for noncontrast routine exams; {alpha}=1.1-1.25 for contrast-enhanced routine exams; and {alpha}=1.5-2.0 for CT angiography. For the five thoracic phantoms in the experiment, when {alpha}=1, the optimal tube potentials were 80, 100, 100, 120, 120, respectively. The corresponding RDFs (relative to 120 kV) were 78.0%, 90.9%, 95.2%, 100%, and 100%. When {alpha}=1.5, the optimal tube potentials were 80, 80, 80, 100, 100, respectively, with corresponding RDFs of 34.7%, 44.7%, 54.7%, 60.8%, and 89.5%. Conclusions: A general strategy to automatically select the most dose efficient tube potential for CT exams was developed that takes into account patient size and diagnostic task. Dependent on the patient size and the selection of noise constraint parameter for different diagnostic tasks, the dose reduction at each tube potential, quantified explicitly with the RDF, varies significantly.

61 RADIATION PROTECTION AND DOSIMETRY↗

Obtaining high resolution XUV coronal images

Photographs obtained during three flights of an 11 inch diameter normal incident soft X-ray (wavelength 63.5 A) telescope are analyzed and the data are compared to the results expected from tests of the mirror surfaces. Multilayer coated X ray telescopes have the potential for 0.01 arcsec resolution, and there is optimism that such high quality mirrors can be built. Some of the factors which enter into the performance actually achieved in practice are as follows: quality of the mirror substrate, quality of the multilayer coating, and number of photons collected. Measurements of multilayer mirrors show that the actual performance achieved in the solar X-ray images demonstrates a reduction in the scattering compared to that calculated from the topography of the top surface of the multilayer. In the brief duration of a rocket flight, the resolution is also limited by counting statistics from the number of photons collected. At X-ray Ultraviolet (XUV) wavelengths from 171 to 335 A the photon flux should be greater than 10(exp 10) ph/sec, so that a resolution better than 0.1 arcsec might be achieved, if mirror quality does not provide a limit first. In a satellite, a large collecting area will be needed for the highest resolution.

Golub, L.↗

High spatiotemporal variability of bacterial diversity over short time scales with unique hydrochemical associations within a shallow aquifer

Understanding microbial community structure and function within the subsurface is critical to assessing overall quality and maintenance of groundwater; however, the factors that determine microbial community assembly, structure, and function in groundwater systems and their impact on water quality remains poorly understood. In this study, three shallow wells (FW301, FW303, FW305) in a non-contaminated shallow aquifer in the ENIGMA-Oak Ridge Field Research Center (Oak Ridge, TN) were sampled approximately 3 times a week over a period of three months to measure changes in groundwater geochemistry and microbial diversity. It was expected that the sampled microbial diversity from two historic field wells (FW301, FW303) would be relatively stable, while diversity from a newer well (FW305) would be less stable over time. The wells displayed some degree of hydrochemical variability over time unique to each well, with FW303 being overall the most stable well and FW301 being the most dynamic based upon dissolved oxygen, conductivity, and nitrate. Community analysis via ss-rRNA paired-end sequencing and distribution-based clustering revealed higher OTU richness, diversity, and variability in groundwater communities of FW301 than the other two wells for diversity binned over all time points. Microbial community composition of a given well was on average > 50% dissimilar to any other well at a given time (days), yet, functional gene diversity as measured with GeoChip remained relatively constant. Similarities in community structure across wells were observed with respect to the presence of 20 shared bacterial groups in all samples in all wells, although at varying levels over the tested time period. Similarity percentage (SIMPER) analysis revealed that variability in FW301 was largely attributed to low abundance, highly-transient populations, while variability in the most hydrochemically stable well (FW303) was due to fluctuations in more highly abundant and frequently present taxa. Additionally, the youngest well FW305 showed a dramatic shift in community composition towards the end of the sampling period that was not observed in the other wells, suggesting possible succession events over time. Time-series analysis using vector auto-regressive models and Granger causality showed unique relationships between richness and geochemistry over time in each well. Finally, these results indicate temporally dynamic microbial communities over short time scales, with day-to-day population shifts in local community structure influenced by available source community diversity and local groundwater hydrochemistry.

59 BASIC BIOLOGICAL SCIENCES↗

Remote auditing of radiotherapy facilities using optically stimulated luminescence dosimeters

Purpose: On 1 July 2012, the Australian Clinical Dosimetry Service (ACDS) released its Optically Stimulated Luminescent Dosimeter (OSLD) Level I audit, replacing the previous TLD based audit. The aim of this work is to present the results from this new service and the complete uncertainty analysis on which the audit tolerances are based. Methods: The audit release was preceded by a rigorous evaluation of the InLight® nanoDot OSLD system from Landauer (Landauer, Inc., Glenwood, IL). Energy dependence, signal fading from multiple irradiations, batch variation, reader variation, and dose response factors were identified and quantified for each individual OSLD. The detectors are mailed to the facility in small PMMA blocks, based on the design of the existing Radiological Physics Centre audit. Modeling and measurement were used to determine a factor that could convert the dose measured in the PMMA block, to dose in water for the facility's reference conditions. This factor is dependent on the beam spectrum. The TPR{sub 20,10} was used as the beam quality index to determine the specific block factor for a beam being audited. The audit tolerance was defined using a rigorous uncertainty calculation. The audit outcome is then determined using a scientifically based two tiered action level approach. Audit outcomes within two standard deviations were defined as Pass (Optimal Level), within three standard deviations as Pass (Action Level), and outside of three standard deviations the outcome is Fail (Out of Tolerance). Results: To-date the ACDS has audited 108 photon beams with TLD and 162 photon beams with OSLD. The TLD audit results had an average deviation from ACDS of 0.0% and a standard deviation of 1.8%. The OSLD audit results had an average deviation of −0.2% and a standard deviation of 1.4%. The relative combined standard uncertainty was calculated to be 1.3% (1σ). Pass (Optimal Level) was reduced to ≤2.6% (2σ), and Fail (Out of Tolerance) was reduced to >3.9% (3σ) for the new OSLD audit. Previously with the TLD audit the Pass (Optimal Level) and Fail (Out of Tolerance) were set at ≤4.0% (2σ) and >6.0% (3σ). Conclusions: The calculated standard uncertainty of 1.3% at one standard deviation is consistent with the measured standard deviation of 1.4% from the audits and confirming the suitability of the uncertainty budget derived audit tolerances. The OSLD audit shows greater accuracy than the previous TLD audit, justifying the reduction in audit tolerances. In the TLD audit, all outcomes were Pass (Optimal Level) suggesting that the tolerances were too conservative. In the OSLD audit 94% of the audits have resulted in Pass (Optimal level) and 6% of the audits have resulted in Pass (Action Level). All Pass (Action level) results have been resolved with a repeat OSLD audit, or an on-site ion chamber measurement.

61 RADIATION PROTECTION AND DOSIMETRY↗

A piloted simulation of helicopter air combat to investigate effects of variations in selected performance and control response characteristics

A piloted simulation study investigating handling qualities and flight characteristics required for helicopter air to air combat is presented. The Helicopter Air Combat system was used to investigate this role for Army rotorcraft. Experimental variables were the maneuver envelope size (load factor and sideslip), directional axis handling qualities, and pitch and roll control-response type. Over 450 simulated, low altitude, one-on-one engagements were conducted. Results from the experiment indicate that a well damped directional response, low sideforce caused by sideslip, and some effective dihedral are all desirable for weapon system performance, good handling qualities, and low pilot workload. An angular rate command system was favored over the attitude type pitch and roll response for most applications, and an enhanced maneuver envelope size over that of current generation aircraft was found to be advantageous. Pilot technique, background, and experience are additional factors which had a significant effect on performance in the air combat tasks investigated. The implication of these results on design requirements for future helicopters is presented.

Lewis, Michael S.↗

Uncertainty in inventories for life cycle assessment: State‐of‐the‐art, challenges, and new technologies

Uncertainty is a critical factor that can hinder the quality and potential applications of life cycle assessment (LCA) results. A prominent source of uncertainty stems from the life cycle inventory (LCI) data. Various methodologies exist to estimate the uncertainty associated with LCI data, primarily based on the widely used structured pedigree matrix approach or the computationally intensive Monte Carlo simulation. This perspective review explores how new technologies (e.g., computational algorithms and data collection methods) from data science and related fields can contribute to identifying, quantifying, and reducing uncertainty in LCI modeling. A brief overview of the sources of uncertainty in LCI modeling and how they are addressed in current LCA practice is provided. Additionally, several new technologies are identified, and the potential benefits of their implementation in reducing uncertainties in LCI modeling are discussed. This perspective review concludes by identifying potential areas that require further development for these technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗