Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Securing the Modern Grid: Federal Investments, Digitization, and Supply Chain Strategy

Across the United States (U.S.) grid expansion and modernization is underway, paving the way for accelerated load growth and intelligent resource management. Digitization of the grid is supported by several state and federal programs, providing support for utilities installing advanced metering infrastructure (AMI), AI-powered analytics systems, battery energy storage systems (BESS), and distributed energy resource management systems (DERMS) to transform the grid from a one-way power delivery system into an intelligent, responsive network that will enable faster load growth and power expansion of data centers for advanced artificial intelligence (AI) applications. The digital transformation of America's grid presents opportunity for increased efficiency and resiliency but also introduces new digital risks that require careful management. Digital equipment often contains several vulnerabilities such as unencrypted communication protocols, and persistent remote access capabilities that could be exploited to manipulate device settings, coordinate service disruptions, or inject false data into grid operations. These digital risks become particularly important as the grid must rapidly scale to support AI-driven data centers, which the administration has identified as essential for maintaining U.S. technological leadership and economic competitiveness. These vulnerabilities are compounded by supply chain realities: Chinese manufacturers currently produce 70-90% of essential grid components including inverters, batteries, and control systems, with the U.S. lacking domestic manufacturing capacity for critical assets like extra-high voltage transformers. Recent federal legislation has established Foreign Entity of Concern (FEOC) restrictions to address these risks, requiring projects to achieve escalating thresholds of non-FEOC content to receive tax credits while utilities work to expand sourcing channels for their supply chains and strengthen security measures. These restrictions arrive precisely when utilities face unprecedented electricity demand growth driven by the rapid growth in data centers, creating a considerable challenge: rapidly expanding infrastructure while navigating complex compliance requirements while lacking viable alternatives for many critical components. Idaho National Laboratory (INL) and its partners have developed practical approaches to help utilities navigate these intersecting challenges as they leverage federal investment to strengthen and grow the grid. These solutions include Cyber-Informed Engineering (CIE) principles that build resilience directly into systems, the Cirrus tool for secure cloud migration, and enhanced procurement guidance that embeds security requirements throughout equipment lifecycles. Federal initiatives, such as the Technical Assistance for Digital Assurance (TADA) project, provide direct support to utilities implementing these approaches while facilitating knowledge sharing across the industry. While these tools and frameworks cannot eliminate all risks inherent in foreign supply chain dependencies, they offer pragmatic pathways for strengthening security posture without sacrificing the deployment momentum essential to meeting surging electricity demand. Ultimately, securing America's digital energy infrastructure demands dedicated coordination across multiple fronts: building domestic supply chains, implementing robust digital assurance practices, and maintaining the aggressive modernization timeline necessary for reliability, resilience, and energy independence.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Interconnection Requirements for Renewable Generation and Energy Storage in Island Systems: Puerto Rico Example: Preprint

On September 20, 2017, Hurricane Maria made landfall in Puerto Rico, incapacitating the central power system and leaving the entire island without power. To ensure the long-term recovery of Puerto Rico's electric power grid in the most secure and resilient way, the U.S. Department of Energy funded research to develop recommendations for a cohesive new framework of interconnection standards for utility-scale renewable electrical generation and energy storage that ensure cross-technology compatibility and enable high deployment levels without compromising grid reliably, safety, or security. This paper provides a summary of work conducted by the National Renewable Energy Laboratory to analyze and address many shortcomings and areas of improvement to help the Puerto Rico Electric Power Authority (PREPA) establish minimum technical requirements for interconnecting single-technology and hybrid renewable generation because of their importance for PREPA system security and impacts on future integrated resource planning scenarios. Results and findings presented in this paper are important for any island power system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A statistical study of Pc 3-5 pulsations observed by the AMPTE/CCE magnetic fields experiment. I - Occurrence distributions

A classification system based on dynamic power spectra of AMPTE/CCE magnetic field data has been developed which allows semiquantitative specification of pulsation activity at all times. Fifteen months of 6.24-s AMPTE/CCE magnetic field data have been analyzed using this scheme to generate a comprehensive data base of all pulsation activity observed from L = 5 to L = 9 at all local times in the frequency range 0-80 mHz. The pulsation divide naturally into five basic categories: toroidal fundamental mode resonances, toroidal harmonic resonances, compressional low-frequency waves, radially polarized waves, and disturbed intervals. Additional distinctions among members of these classes are made to arrive at 14 categories which describe 95 percent of the pulsations observed. Normal spatial distributions in local time and L shell are determined for each category. Magnetic latitude distributions are determined for four coherent categories of activity.

Anderson, B. J.↗

Universality behind Basquin's Law of Fatigue

Basquin's law of fatigue states that the lifetime of the system has a power-law dependence on the external load amplitude, t{sub f}{approx}{sigma}{sub 0}{sup -{alpha}}, where the exponent {alpha} has a strong material dependence. We show that in spite of the broad scatter of the exponent {alpha}, the fatigue fracture of heterogeneous materials exhibits universal features. We propose a generic scaling form for the macroscopic deformation and show that at the fatigue limit the system undergoes a continuous phase transition. On the microlevel, the fatigue fracture proceeds in bursts characterized by universal power-law distributions. We demonstrate that the system dependent details are contained in Basquin's exponent for time to failure, and once this is taken into account, remaining features of failure are universal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

On Information Transfer-Based Characterization of Power System Stability

In this study, we present a novel approach to identify the generators and states responsible for the small-signal stability of power networks. To this end, the newly developed notion of information transfer between the states of a dynamical system is used. In particular, using the concept of information transfer, which characterizes influence between the various states of a dynamical system, we identify the generators and states which are responsible for causing instability of the power network. While characterizing influence from state to state, information transfer can also describe influence from state to modes thereby generalizing the well-known notion of participation factor while at the same time overcoming some of the limitations of the participation factor. The developed framework is applied to reproduce known results for the three bus system, identifying the various causes of instabilities, and is extended to IEEE 39 bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Future of Transportation Electrification: Utility, Industry and Consumer Perspectives

Electric vehicles (EVs) today are a small part of the U.S. transportation fleet. Technological advancements, automotive industry investments and state policies are driving increased transportation electrification. Bloomberg New Energy Finance projects that by 2040, 55 percent of new sales of automobiles worldwide will be EVs. Increased transportation demand for electricity will require additional investments in the distribution system and will impact the bulk power system as load profiles change. At the same time, managed EV charging and discharging can make more efficient use of distribution system assets and increase grid flexibility. EVs also hold promise for lowering transportation costs and reducing air emissions. Infrastructure needs to electrify transportation across the United States far exceed current investment plans by EV charging companies, the public sector and others. Utilities are building “make-ready” infrastructure to ease development of public charging stations and offering rates tailored for EVs, and some utilities are directly investing in charging stations. The growth of EVs raises a number of questions for policymakers and others: How much public charging infrastructure will be needed, where should it be built and when will it be used? What role should utilities play in developing the infrastructure, compared to EV charging companies?How should charging infrastructure costs be allocated among utility customers? How should electricity rates be set to encourage efficient grid use and minimize negative grid impacts? How are states preparing for increasing electrification of the transportation sector? This report in the Future Electric Utility Regulation series from Berkeley Lab, tackles these questions and more. The report approaches the issues from three perspectives: utilities, the EV charging industry and consumers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

General Requirements for Designing and Implementing a Cryptography Module for Distributed Energy Resource (DER) Systems

Penetration of distributed energy resources (DERs) is rapidly increasing in the bulk power system (BPS); they are growing to be a significant portion of generation. As such, grid-support capabilities are being developed and implemented. However, as their presence increases, the impact of DERs on the BPS also increases. Therefore, if a disturbance occurs in the DER system, its effects could propagate throughout the BPS. These disturbances could range from equipment malfunctions to resource variability to cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linear Approximation Line Pack Model for Integrated Electricity and Natural Gas Systems OPF

With the increasing installation of renewable energy electricity generation capacity, the penetration of natural gas fired generation is also substantailly increasing in power systems due to their fast response capability to mitigate system variability and uncertainty. The dependencies between the electricity system and the natural gas system are becoming more important to maintain the reliability of both systems. In integrated electricity and natural gas systems (IEGSs) operations, the nonlinearity of the natural gas system brings challenges to the system operators. In this paper, the IEGSs optimal power flow (OPF) model is proposed that includes the line pack of the gas system via linear approximation. The simulation results demonstrate that the proposed model can obtain optimal solutions efficiently that are comparable in accuracy as the nonlinear line pack model.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Dynamic Power System Stability Analysis and Control

The objective of this research is to conduct dynamic analysis, control design, and control performance test of solar power system. Solar power system consists of generation system and distribution network system. A bench mark system is used in this research, which includes a generator with excitation system and governor, an ac/dc converter, six DDCU's and forty-eight loads. A detailed model is used for modeling generator. Excitation system is represented by a third order model. DDCU is represented by a seventh order system. The load is modeled by the combination of constant power and constant impedance. Eigen-analysis and eigen-sensitivity analysis are used for system dynamic analysis. The effects of excitation system, governor, ac/dc converter control, and the type of load on system stability are discussed. In order to improve system transient stability, nonlinear ac/dc converter control is introduced. The direct linearization method is used for control design. The dynamic analysis results show that these controls affect system stability in different ways. The parameter coordination of controllers are recommended based on the dynamic analysis. It is concluded from the present studies that system stability is improved by the coordination of control parameters and the nonlinear ac/dc converter control stabilize system oscillation caused by the load change and system fault efficiently.

Momoh, James A.↗

A Coordinated Compensation Strategy for Module-Mismatch of CHB-PV Systems Based on Improved LS-PWM and Reactive Power Injection

Here, the cascaded H-bridge (CHB) converter has become a promising candidate topology for utility-scale photovoltaic systems thanks to merits like modular structure, distributed maximum power point tracking (MPPT), and direct distribution grid access without medium-voltage transformers, etc. However, module-mismatches arising from non-ideal elements like partial shading and parameter variations pose a technical challenge for such systems. If not dealt with properly, module-mismatches can lead to adverse effects like unbalanced dc-link voltages of the modules, distortion of grid current, reduced power generation, etc. Conventional methods, such as reactive power compensation and level-shifted pulse-width modulation (LS-PWM) based compensation, can alleviate this issue, but their performances are still limited by the allowable modulation range of power converters. In this paper, a compensation strategy combining reactive power compensation with a novel modulation method is proposed to extend the operating range in terms of module mismatch. Experimental results on a 2.4kW/208V single-phase setup are presented and have demonstrated that the proposed method can not only ride through a larger range of module-mismatches but also improve solar power utilization and system efficiency owing to reduced switching events, non-compromised MPPT, and less required reactive power.

42 ENGINEERING↗

PhotoVoltaic distributed generation for Lanai power grid real-time simulation and control integration scenario.

This paper discusses the modeling, analysis, and testing in a real-time simulation environment of the Lanai power grid system for the integration and control of PhotoVoltaic (PV) distributed generation. The Lanai Island in Hawaii is part of the Hawaii Clean Energy Initiative (HCEI) to transition to 30% renewable green energy penetration by 2030. In Lanai the primary loads come from two Castle and Cook Resorts, in addition to residential needs. The total peak load profile is 12470 V, 5.5 MW. Currently there are several diesel generators that meet these loading requirements. As part of the HCEI, Lanai has initially installed 1.2 MW of PV generation. The goal of this study has been to evaluate the impact of the PV with respect to the conventional carbon-based diesel generation in real time simulation. For intermittent PV distributed generation, the overall stability and transient responses are investigated. A simple Lanai 'like' model has been developed in the Matlab/Simulink environment (see Fig. 1) and to accommodate real-time simulation of the hybrid power grid system the Opal-RT Technologies RT-Lab environment is used. The diesel generators have been modelled using the SimPowerSystems toolbox swing equations and a custom Simulink module has been developed for the High level PV generation. All of the loads have been characterized primarily as distribution lines with series resistive load banks with one VAR load bank. Three-phase faults are implemented for each bus. Both conventional and advanced control architectures will be used to evaluate the integration of the PV onto the current power grid system. The baseline numerical results include the stable performance of the power grid during varying cloud cover (PV generation ramping up/down) scenarios. The importance of assessing the real-time scenario is included.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A novel large-scale EV charging scheduling algorithm considering V2G and reactive power management based on ADMM

Electric vehicle aggregators (EVAs) that utilize vehicle-to-grid (V2G) technologies can function as both controllable loads and virtual power plants, providing key energy management services to the distribution system operator (DSO). EVAs can also balance the grid’s reactive power as a virtual static VAR compensator (SVC) and provide voltage stability by utilizing advanced electric vehicle (EV) chargers that are capable of four-quadrant operations to provide reactive power management. Finally, managed charging can benefit EVAs themselves by minimizing power factor penalties in their electricity bills. In this paper, we propose a novel EV charging scheduling algorithm based on a hierarchical distributed optimization framework that minimizes peak load and provides reactive power compensation for the DSO by collaboration with EVAs that manage both the active and the reactive charging and discharging power of participating EVs. Utilizing the alternative direction method of multipliers (ADMM), the proposed distributed optimization approach scales well with increased EV charging infrastructure by balancing active and reactive power while decreasing computational burden. In our proposed hierarchical approach, each EVA schedules the active and reactive EV charging and discharging power for 1) reactive power compensation in order to minimize power factor penalty and electricity cost accrued by the EVA, 2) satisfaction of each EV’s energy demand at minimal charging cost, and 3) peak shaving and load management for the DSO. When compared with an uncoordinated charging model, the efficacy of this proposed model is successfully demonstrated through a 300% decreased peak EV load for the DSO, 28% lower electricity costs for EV users, and 98.55% smaller power factor penalty, along with 17.58% lower overall electricity costs, for EVAs. The performance of our approach is validated in a case study with 50 EVs at multiple EVAs in an IEEE 13-bus test case and compared the results with uncoordinated EV charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Novel Equivalent Model of Active Distribution Networks Based on LSTM

Dynamic behaviors of distribution networks are of great importance for the power system analysis. Nowadays, due to the integration of the renewable energy generation, energy storage, plug-in electric vehicles, and distribution networks turn from passive systems to active ones. Hence, the dynamic behaviors of active distribution networks (ADNs) are much more complex than the traditional ones. The research interests how to establish an accurate model of ADNs in modern power systems are drawing a great deal of attention. In this paper, motivated by the similarities between power system differential algebraic equations and the forward calculation flows of recurrent neural networks (RNNs), a long short-term memory (LSTM) RNN-based equivalent model is proposed to accurately represent the ADNs. First, the adoption reasons of the proposed LSTM RNN-based equivalent model are explained, and its advantages are analyzed from the mathematical point of view. Then, the accuracy and generalization performance of the proposed model is evaluated using the IEEE 39-Bus New England system integrated with ADNs in the study cases. Here, it reveals that the proposed LSTM RNN-based equivalent model has a generalization capability to capture the dynamic behaviors of ADNs with high accuracy.

42 ENGINEERING↗

Independent Orbiter Assessment (IOA): Assessment of the orbital maneuvering subsystem, volume 2

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the Orbital Maneuvering System (OMS) hardware and electrical power distribution and control (EPD and C), generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter OMS hardware and EPD and C systems. Volume 2 continues the presentation of IOA worksheets and contains the critical items list and the NASA FMEA to IOA worksheet cross reference and recommendations.

Haufler, W. A.↗

Independent Orbiter Assessment (IOA): Assessment of the reaction control system, volume 1

The results of the Independent Orbiter Assessment (IOA) of the Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL) are presented. The IOA effort first completed an analysis of the aft and forward Reaction Control System (RCS) hardware, and Electrical Power Distribution and Control (EPD and C), generating draft failure modes and potential critical items. To preserve independence, this analysis was accomplished without reliance upon the results contained within the NASA FMEA/CIL documentation. The IOA results were then compared to the proposed Post 51-L NASA FMEA/CIL baseline. This report documents the results of that comparison for the Orbiter RCS hardware and EPD and C systems. The IOA product for the RCS analysis consisted of 208 hardware and 2064 EPD and C failure mode worksheets that resulted in 141 hardware and 449 EPD and C potential critical items (PCIs) being identified. A comparison was made of the IOA product to the NASA FMEA/CIL baseline. After comparison and discussions with the NASA subsystem manager, 96 hardware issues, 83 of which concern CIL items or PCIs, and 280 EPD and C issues, 158 of which concern CIL items or PCIs, and 280 EPD and C issues, 158 of which concern CIL items or PCIs, remain unresolved. Volume 1 contains the subsystem description, assessment results, and some of the IOA worksheets.

Prust, Chet D.↗

Complementarities of supply and demand sides in integrated energy systems

New small-scale demand-side technologies, such as micro combined heat and power technologies (uCHPs) and heat pumps (HPs), offer opportunities to increase system-wide efficiency. Furthermore, the technical and economic characteristics of demand-side technologies could also complement the supply side by providing system services, such as adequacy and flexibility, which are increasingly required due to high variable renewable energy penetration. A capacity expansion methodology that captures the interactions between the supply and demand sides is developed to find cost-optimal and adequate investment portfolios. For the case study presented, the integrated energy system leverages the technical and economic complementarities of different supply and demand-side technologies. As a result, system integration using demand-side technologies improves the value proposition for decentralization given that the technologies can provide heat demand, while also meeting electricity demand and providing adequacy and flexibility.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling Framework for Data Center

This chapter highlights the critical need for advanced modeling of data centers due to their rapidly increasing energy consumption and impact on grid reliability. Driven by the demand for AI applications, data centers are projected to consume a significant portion of US energy by 2028, putting stress on an already challenged power grid. The chapter emphasizes the importance of "fast" time-scale models to understand the dynamic interactions between data centers and the grid, especially given the rapid power fluctuations of AI workloads. It outlines a modeling framework that includes both offline and real-time EMT domain simulations, detailing the necessary representations for various components like utility interfaces, transformers, IT loads, UPS, cooling loads, Battery Energy Storage Systems (BESS), generators, protection systems, and higher-level control systems. While standard simulation tools like PSCAD offer basic models, custom development is often required to accurately capture the unique and fast-changing behaviors of modern data centers. The chapter also discusses key metrics and test cases for validating these models, focusing on transient load responses, protection relay coordination, and demand flexibility. Finally, it addresses the challenges of modeling large-scale data centers, such as computational complexity and the trade-off between model fidelity and practicality, suggesting hybrid modeling approaches as a solution. The overarching goal is to create a robust framework that helps assess data center impacts on grid stability, identify vulnerabilities, and inform the development of standards for reliable integration of these large loads into the bulk power system.

25 ENERGY STORAGE↗