Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Pink-beam focusing with a one-dimensional compound refractive lens

The performance of a cooled Be compound refractive lens (CRL) has been tested at the Advanced Photon Source (APS) to enable vertical focusing of the pink beam and permit the X-ray beam to spatially overlap with an 80 µm-high low-density plasma that simulates astrophysical environments. Focusing the fundamental harmonics of an insertion device white beam increases the APS power density; here, a power density as high as 500 W mm –2 was calculated. A CRL is chromatic so it does not efficiently focus X-rays whose energies are above the fundamental. Only the fundamental of the undulator focuses at the experiment. A two-chopper system reduces the power density on the imaging system and lens by four orders of magnitude, enabling imaging of the focal plane without any X-ray filter. As a result, a method to measure such high power density as well as the performance of the lens in focusing the pink beam is reported.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Composition of Comet C/2009 P1 (Garradd) from Infrared Spectroscopy: Evidence for an Oxygen-Rich Heritage?

Comets retain relatively primitive icy material remaining from the epoch of Solar System formation, however the extent to which their ices are modified remains a key question in cometary science. One way to address this is to measure the relative abundances of primary (parent) volatiles in comets (i.e., those ices native to the nucleus). High-resolution (lambda/delta lambda greater than 10(exp 4)) infrared spectroscopy is a powerful tool for measuring parent volatiles in comets through their vibrational emissions in the approximately 3-5 micrometer region. With modern instrumentation on world-class telescopes, we can quantify a multitude of species (e.g., H2O, C2H2, CH4, C2H6, CO, H2CO, CH3OH, HCN, NH3), even in comets with modest gas production. In space environments, compounds of keen interest to astrobiology could originate from HCN and NH3 (leading to amino acids), H2CO (leading to sugars), or C2H6, and CH4 (suggested precursors of ethyl- and methylamine). Measuring the abundances of these precursor molecules and their variability among comets contributes to understanding the synthesis of the more complex prebiotic compounds.

DiSanti, M. A.↗

The Composition of Comet C/2009 PI (Garradd) from Infrared Spectroscopy: Evidence for an Oxygen-Rich Heritage?

Comets retain relatively primitive icy material remaining from the epoch of Solar System for111ation, however the extent to which their ices are modified remains a key question in cometary science. One way to address this is to measure the relative abundances of primary (parent) volatiles in comets (i.e., those ices native to the nucleus). High-resolution (lambda/delta lambda greater than 10(exp 4)) infrared spectroscopy is a powerful tool for measuring parent volatiles in comets through their vibrational emissions in the ~ 3-5 micrometer region. With modern instrumentation on worldclass telescopes, we can quantify a multitude of species (e.g., H2O, C2H2, CH4, C2H6 CO, H2CO, CH3OH, HCN, NH3), even in comets with modest gas production. In space environments, compounds of keen interest to astrobiology could originate from HCN and NH3 (leading to amino acids), H2CO (leading to sugars), or C2H6 and CH4 (suggested precursors of ethyl- and methylamine). Measuring the abundances of these precursor molecules and their variability among comets contributes to understanding the synthesis of the more complex prebiotic compounds.

DiSanti, M. A.↗

Power cepstrum technique with application to model helicopter acoustic data

The application of the power cepstrum to measured helicopter-rotor acoustic data is investigated. A previously applied correction to the reconstructed spectrum is shown to be incorrect. For an exact echoed signal, the amplitude of the cepstrum echo spike at the delay time is linearly related to the echo relative amplitude in the time domain. If the measured spectrum is not entirely from the source signal, the cepstrum will not yield the desired echo characteristics and a cepstral aliasing may occur because of the effective sample rate in the frequency domain. The spectral analysis bandwidth must be less than one-half the echo ripple frequency or cepstral aliasing can occur. The power cepstrum editing technique is a useful tool for removing some of the contamination because of acoustic reflections from measured rotor acoustic spectra. The cepstrum editing yields an improved estimate of the free field spectrum, but the correction process is limited by the lack of accurate knowledge of the echo transfer function. An alternate procedure, which does not require cepstral editing, is proposed which allows the complete correction of a contaminated spectrum through use of both the transfer function and delay time of the echo process.

Martin, R. M.↗

Non-destructive quantification of water gradient in sludge composting with Magnetic Resonance Imaging

Sludge from a slaughter-house wastewater plant, and mixtures of bulking agent (crushed wood pallet) and sludge were studied by Nuclear Magnetic Resonance (NMR). The NMR spin-spin relaxation (T{sub 2}) and spin-lattice relaxation (T{sub 1}) signals for sludge, wet crushed wood pallet and mixtures of sludge and bulking agent were decomposed into three relaxation time components. Each relaxation time component was explained by a non-homogeneous water distribution on a microscopic length scale and by the porosity of the material. For all samples, the T{sub 2} relaxation time value of each component was directly related to the dry matter content. The addition of wet crushed wood to sludge induced a decrease in the relaxation time, explained by water transfer between the sludge and the wood. Magnetic Resonance Imaging (MRI) and respirometric measurements were performed on sludge and wood mixtures. MR images of the mixtures were successfully obtained at different biodegradation states. Based on specific NMR measurements in an identified area located in the MRI cells, the results showed that grey levels of MR images reflected dry matter content. This preliminary study showed that MRI would be a powerful tool to measure water distribution in sludge and bulking agent mixtures and highlights the potential of this technique to increase the understanding of sludge composting.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Near-Unity Photoluminescence Quantum Yield in Blue-Emitting Cs 3 Cu 2 Br 5– x I x (0 ≤ x ≤ 5)

Recently, interest in developing efficient, low-cost, nontoxic, and stable metal halide emitters that can be incorporated into solid-state lighting technologies has taken hold. Here we report nontoxic, stable, and highly efficient blue-light-emitting Cs 3 Cu 2 Br 5–x I x (0 ≤ x ≤ 5). Room-temperature photoluminescence measurements show bright blue emission in the 456 to 443 nm range with near-unity quantum yield for Cs 3 Cu 2 I 5 . Here, density functional theory calculations and power-dependent PL measurements suggest that the emission results from self-trapped excitons induced by strong charge localization within the zero-dimensional cluster structure of Cs 3 Cu 2 Br 5–x I x .

0D all-inorganic metal halides↗

Investigation of a pulsed electrothermal thruster

Exhaust velocity and thrust measurements are performed on a pulsed electrothermal thruster using polyethylene and Teflon propellants. The results verify theoretical predictions of equilibrium flow in the nozzle, resulting in substantial recovery of the energy of dissociation and ionization. The thruster is tested in an unsteady mode (15 micro sec current pulse and 15 cm discharge length) and in a quasi-steady mode (48 micro sec current pulse and 5 cm discharge length). All tests are run at 2 kJ. The exhaust velocity of the propellant mass exiting during the current pulse is measured with two types of time of flight probes, and the impulse bit is measured on a thrust stand. It is inferred from both theory and experiment that an additional amount of mass is exhausted after the pulse. The measured thrust to power ratio for polyethylene is T/P = 0.10 NkW at 21 km/sec in the unsteady mode, and T/P = .053 N/kW at 27 km/sec in the quasi-steady mode, where the velocities are measured by the time-of-flight probes. For Teflon propellant, T/P = .20 N/kW at 15 km/sec (unsteady mode) and 0.090 N/kW at 20 km/sec (quasi-steady mode). The discharge pressure and temperature predicted by a computational model for polyethylene are consistent with the measured thrust and discharge resistance.

Burton, R. L.↗

Evaluation of a potassium filled UO{sub 2} core in a beryllium-reflected space reactor - 14371

The critical configuration of the small, compact critical assembly (SCCA) experiments performed at the Oak Ridge Critical Experiments Facility (ORCEF) in 1962-1965[1,2] have been evaluated for the International Criticality Safety Benchmark Evaluation Project (ICSBEP) and were determined to be acceptable benchmark experiments and are included in the International Handbook of Evaluated Criticality Safety Benchmark Experiments (ICSBEP Handbook)[3]. The initial intent of these experiments was to support the design of the Medium Power Reactor Experiment (MPRE) program, whose purpose was to study 'power plants for the production of electrical power in space vehicles'.[4] The third configuration in this series of experiments was a beryllium-reflected mockup of a stainless-steel-clad, highly enriched uranium (HEU)-O{sub 2} fuel, potassium-cooled, space power reactor. Reactivity measurements, cadmium ratio spectral measurements, and fission rate measurements were measured through the core and top reflector. Fuel effect worth measurements and neutron moderating and absorbing material worths were also measured in the assembly fuel region. The cadmium ratios, fission rate, and worth measurements were evaluated for the International Reactor Physics Experiment Evaluation Project (IRPhEP) and are published in the International Handbook of Evaluated Reactor Physics Benchmark Experiments (IRPhEP Handbook)[5]. More recently, two additional critical configurations have been evaluated and added to the existing evaluation report in the ICSBEP Handbook. The new critical configurations measure the effect of filling the core with potassium. The critical configuration consisted of 30.48 cm tall fuel tubes of 93.15 wt.% enriched uranium dioxide (UO{sub 2}) pellets. Each fuel tube had 26 pellets with a total mass of 295.8 g UO{sub 2} per tube. There were 253 tubes were arranged with 1.506-cm center-to-center, triangular spacing and surrounded on all side by a beryllium reflected. The reactivity of the system was measured with the core tank empty and filled with potassium. The system reactivity was increased from 13.4 c to 32 c. This change in system reactivity represents the worth of the potassium. Simple benchmark models for the empty and potassium filled cores have been derived and evaluated and found to be acceptable as benchmark experiments. The benchmark experiment eigenvalues are 1.0001 ± 0.0008 and 1.0011 ± 0.0009 for the empty and filled cores, respectively. When calculated with MCNP5 and ENDF/B-VII.0 the calculated eigenvalues are 0.98906 ± 0.00002 and 0.98883 ± 0.00002, respectively. These results are concerning due to the drop of the calculated system reactivity when potassium is added to the system rather than the expected increase in system reactivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

High-sensitivity receiver for infrared laser communications.

Description of a high-sensitivity wide-bandwidth 10.6-micron heterodyne receiver for space and ground operational use. The receiver includes a cooled HgCdTe infrared mixer diode, a conical scanner for spatial tracking, an acquisition channel for spatial search and station alignment, and an automatic frequency-control channel to maintain a fixed laser frequency offset. The infrared mixer is designed to provide nearly quantum-noise-limited operation over an extended range of mixer temperature, bias voltage, and intermediate frequency. The resultant experimental receiver has a measured noise equivalent power of less than 10 to the minus 19th W/Hz over the 15- to 40-MHz i.f. band for mixer temperatures from 85 to 115 K, and less than 2 x 10 to the minus 19th W/Hz up to 140 K. Mixer 3-dB cutoff frequencies as high as 420 MHz were measured at a mixer temperature of 125 K. An analysis and engineering equations are given for receiver noise components, noise equivalent power, available mixer conversion gain, mixer transducer gain, and quantum-noise factor in terms of such factors as mixer parameters, quantum efficiency, mixer temperature, dynamic conductance, bias voltage, local oscillator power, and i.f. amplifier characteristics.

Peyton, B. J.↗

The Potential of Water Vapor & Precipitation Estimation with a Differential-frequency Radar

In the presence of rain, the radar return powers from a three-frequency radar, with center frequency at 22.235 GHz and upper and lower frequencies chosen with equal water vapor absorption coefficients, can be used to estimate water vapor density and parameters of the precipitation. A linear combination of differential measurements between the center and lower frequencies on one hand and the upper and lower frequencies on the other provide an estimate of differential water vapor absorption. Conversely, the difference in radar reflectivity factors (in dB) between the upper and lower frequencies is independent of water vapor absorption and can be used to estimate the median mass diameter of the hydrometeors. For a down-looking radar, path-integrated estimates of water vapor absorption may be possible under rain-free as well as raining conditions by using the surface returns at the three frequencies. Cross-talk or interference between the precipitation and water vapor estimates depends on the frequency separation of the channels as well as on the phase state and the median mass diameter of the hydrometeors. Simulations of the retrieval of water vapor absorption show that the largest source of variability arises from the variance in the measured radar return powers while the largest biases occur in the mixed-phase region. Use of high pulse repetition frequencies and signal whitening methods may be needed to obtain the large number of independent samples required. Measurements over a fractional bandwidth, defined as the ratio of the difference between the upper and lower frequencies to the center frequency, up to about 0.2 should be passible in a differential frequency mode, where a single transceiver and antenna are used. Difficulties in frequency allocation may require alternative choices of frequency where the water vapor absorptions at the low and high frequencies are unequal. We consider the degradation in the retrieval accuracy when the frequencies are not optimum.

Meneghini, Robert↗

OPTIMAL BINNING OF THE PRIMORDIAL POWER SPECTRUM

The primordial power spectrum describes the initial perturbations in the universe, which eventually grew into the large-scale structure we observe today, and thereby provides an indirect probe of inflation or other structure-formation mechanisms. In this paper, we will investigate the best scales the primordial power spectrum can be probed with in accordance with the knowledge about other cosmological parameters such as OMEGA{sub b}, OMEGA{sub c}, OMEGA{sub L}AMBDA, h, and tau. The aim is to find the most informative way of measuring the primordial power spectrum at different length scales, using different types of surveys and the information they provide for the desired cosmological parameters. We will find the optimal binning of the primordial power spectrum for this purpose by making use of the Fisher matrix formalism. To investigate the correlations between the cosmological parameters, mentioned above, and a set of primordial power spectrum bins, we make use of principal component analysis and the Hermitian square root of the Fisher matrix. The surveys used in this project are Planck and the Sloan Digital Sky Survey (Bright Red Galaxy), but the formalism can easily be extended to any windowed measurements of the perturbation spectrum.

79 ASTRONOMY AND ASTROPHYSICS↗

Bright Luminescence from Nontoxic CsCu 2 X 3 (X = Cl, Br I)

Inexpensive and highly efficient luminescent materials based on multinary halides have received increased attention in recent years. Among those considered most promising are the perovskites such as CsPbX 3 because of their highly efficient and tunable emission through precise control of chemical composition and nanostructuring. However, the presence of the toxic heavy metal Pb and relatively poor stability are among the major challenges for the introduction of lead-halide-based materials into the marketplace. In this paper, we report the optical properties of nontoxic and highly emissive one-dimensional (1D) all-inorganic halides CsCu 2 X 3 (X = Cl, Br, I) and their mixed halide derivatives, which also show improved thermal and air stability. Photoluminescence (PL) measurements show tunable bright room temperature emission from green to yellow with photoluminescence quantum yields ranging from 0.37 (CsCu 2 Cl 1.5 Br 1.5 ) to 48.0% (CsCu 2 Cl 3 ). Temperature- and power-dependent PL measurements suggest that the emission results from self-trapped excitons induced by strong charge localization and structural distortions within the lD ribbon structure.

36 MATERIALS SCIENCE↗

HEMT Amplifiers and Equipment for their On-Wafer Testing

Power amplifiers comprising InP-based high-electron-mobility transistors (HEMTs) in coplanar-waveguide (CPW) circuits designed for operation at frequencies of hundreds of gigahertz, and a test set for onwafer measurement of their power levels have been developed. These amplifiers utilize an advanced 35-nm HEMT monolithic microwave integrated-circuit (MMIC) technology and have potential utility as local-oscillator drivers and power sources in future submillimeter-wavelength heterodyne receivers and imaging systems. The test set can reduce development time by enabling rapid output power characterization, not only of these and similar amplifiers, but also of other coplanar-waveguide power circuits, without the necessity of packaging the circuits.

Fung, King man↗

Anodic vacuum arc developed nanocrystalline Cu-Ni and Fe-Ni thin film thermocouples

This paper deals with the development of nanocrystalline Cu-Ni and Fe-Ni thin film thermocouples (TFTCs) by using ion-assisted anodic vacuum arc deposition technique. The crystallographic structure and surface morphology of individual layer films have been studied by x-ray diffraction and scanning electron microscopy, respectively. The resistivity, temperature coefficient of resistance, and thermoelectric power of as deposited and annealed films have been measured. The observed departure of these transport parameters from their respective bulk values can be understood in terms of intrinsic scattering due to enhanced crystallite boundaries. From the measured values of thermoelectric power and the corresponding temperature coefficient of resistance of annealed Cu, Ni, and Fe films, the calculated values of log derivative of the mean free path of conduction electrons at the Fermi surface with respect to energy (U) are found to be -0.51, 3.22, and -8.39, respectively. The thermoelectric response of annealed Cu-Ni and Fe-Ni TFTCs has been studied up to a maximum temperature difference of 300 deg. C. Reproducibility of TFTCs has been examined in terms of the standard deviation in thermoelectric response of 16 test samples for each pair. Cu-Ni and Fe-Ni TFTCs agree well with their wire thermocouple equivalents. The thermoelectric power values of Cu-Ni and Fe-Ni TFTCs at 300 deg. C are found to be 0.0178 and 0.0279 mV/ deg. C, respectively.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Analysis of gamma-ray dosimetry experiments in the zero power MINERVE facility

The objective of this study is to develop nuclear heating measurement methods in zero power experimental reactors. These developments contribute to the qualification of photonics calculation schemes for the assessment of gamma heating in the future Jules Horowitz Material Testing Reactor. This paper presents the analysis of thermoluminescent detector (TLD) experiments in the UO{sub 2} core of the MINERVE Research Reactor at the French Alternative Energies and Atomic Energy Commission center in Cadarache. The experimental sources of uncertainty in the gamma dose have been reduced by improving the measurement conditions and the repeatability of the calibration step for each individual TLD. The interpretation of these measurements needs to take into account the calculation of cavity correction factors related to calibration and irradiation configurations, as well as neutron correction calculations. These calculations are based on Monte Carlo simulations of neutron-gamma and gamma-electron transport coupled particles. The comparison between calculated and measured integral gamma-ray absorbed doses in the aluminum material surrounding the TLD shows that calculations slightly overestimate the measurement, with a calculated versus experimental ratio equal to 1.04 {+-} 5.7 % (k=2). (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Measurement of plasma density in the discharge maintained in a nonuniform gas flow by a high-power terahertz-wave gyrotron

We performed measurements of plasma density in a “point-like” discharge, which is generated in a nonuniform flow of a gas (argon) under the action of high-power terahertz gyrotron radiation with a frequency of 0.67 THz, a power of 40 kW, and a pulse duration of 20 μs. The nonuniform flow was produced by injecting the gas to the vacuum chamber through a small hole (0.14 mm in diameter) under a background pressure at a level of 0.01 Torr. The discharge developed and was localized only in a small region of space (about 1 mm) near the gas injection hole, where the pressure was high (close to the atmospheric one) and the breakdown conditions (the “point-like” discharge) were fulfilled. The density of electrons in the discharge was measured by observing the Stark broadening of the atomic radiation line H{sub α} of hydrogen (656.3 nm) which was present in the discharge as a minor admixture. The plasma density in the discharge was equal to about 2 × 10{sup 16} cm{sup −3}, which exceeds the cut-off density for a frequency of 0.67 THz used to maintain the discharge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Control of the UV flux of a XeCl dielectric barrier discharge excilamp through its current variation

The efficiency of the electrical power transfer to the gas mixture of a XeCl dielectric barrier discharge (DBD) exciplex lamp is analysed. An equivalent circuit model of the DBD is considered. It is shown that the excilamp power can be controlled by applying current to the lamp. This highly desired property is ensured by means of a specific power supply topology, whose concepts and design are discussed. The experimental prototype of a current-mode converter operating in the pulsed regime at pulse repetition rate of 50 kHz is presented and its capability to control the amount of energy transferred during each current pulse is demonstrated. The capability of this power supply to maintain specific operating conditions for the DBD lamp, with a very stable behaviour (even at a very low current, in the regime of a single discharge channel), is illustrated. The experimental results of a combined use of this converter and a XeCl excilamp are presented. The influence of the supply parameters on the 308-nm XeCl excilamp is analysed. The shape of the UV pulse of the lamp is experimentally shown to be similar to that of the current, which actually flows into the gas mixture. The UV radiation power is demonstrated to be tightly correlated to the current injected into the gas and controlled by the available degrees of freedom offered by the power supply. The measured UV output characteristics and performance of the system are discussed. Time resolved UV imaging of a XeCl DBD excilamp is used to analyse the mechanisms involved in the production of exciplexes at various power supply regimes. It is shown that a pulsed voltage source leads to formation of short high intensity UV peaks, while current pulses lead to formation of sustained discharge filaments. Based on the results of modelling of the above-mentioned operation conditions, the two power supply regimes are compared and analysed from the point of view of the UV power and radiative control.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗