Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Polyethylene”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Sensitivity of the active neutron coincidence collar response during simulated and experimental fresh fuel assay

Verification of the fissile (and fertile) content in fresh nuclear fuel assemblies is conducted by the IAEA to enforce the Nuclear Non-Proliferation Treaty using the UNCL (Uranium Neutron Collar — Light Water Reactor Fuel). The UNCL uses an uncorrelated AmLi neutron source to interrogate the fuel, producing a signal of coincident fission neutrons (Doubles rate) used to assay 235 U content of the fuel. The cost of producing calibration assemblies and limited availability of diverse commercial assemblies at any one time historically restricted the ability to explore the full parameter space experimentally. Monte Carlo simulations can overcome this, but introduce additional sources of uncertainty. In this work, the sensitivity of simulations and measurements to various parameters is assessed for a reference 1616 PWR assembly of uniform 3.2% enrichment. Uncertainty contributions in this evaluation include: simulated AmLi neutron source spectrum, AmLi neutron emission rate, AmLi anisotropicity, high density polyethylene (HDPE) density, the precise position of the fuel assembly within the detector, and experimentally the statistical uncertainty. The overall total systematic uncertainty estimate for the simulation of the absolute/relative Doubles rates responses are estimated to be approximately 2.0%/1.5%, and for experimental measurements systematic uncertainty reduces to 1.1%. This analysis supports further work using the relative Doubles rates in place of measurements for updating and extending the UNCL analysis methodology as systematic uncertainty is reasonably small.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The effects of low- Z shielding on uranium isotope discrimination using the time-emission profiles of long-lived delayed neutrons

Characteristic radiation signals can often be obscured or distorted by relatively small amounts of shielding, as is the case for highly-enriched uranium (HEU). Methods that can detect and identify special nuclear material (SNM) even in the presence of shielding are therefore of high value in many nuclear security and nonproliferation applications. It has been previously shown that the buildup and decay time profiles of long-lived delayed neutron emission from induced fission are unique and can be used to successfully discriminate between uranium isotopes and infer enrichment without the need for a calibration standard. Because the long-lived delayed neutron precursors exhibit decay times on the order of tens of seconds, their time profiles are not sensitive to the delays associated with scattering or diffusion in shielding materials, which occur on much shorter time scales. The use of capture-based neutron detectors can also mitigate the effects of shielding, because unlike recoil-based detectors, they do not have a low-energy detection threshold, so that neutrons that lose their energy in the shielding are still detectable. In this work, the effects of low-Z shielding on the discrimination of uranium isotopes using delayed neutron time profile measurements are investigated for the first time. Furthermore, the delayed neutron buildup and decay time profiles of polyethylene-shielded HEU and depleted uranium objects are measured using two different capture-gated detector designs. The recorded profiles show good agreement with the shapes predicted from six-group delayed neutron models even with the shielding in place, and the enrichment of the HEU and DU objects was estimated accurately to within 5%. While this method shows potential for discriminating and characterizing extreme cases of enrichment when a moderate amount of shielding is present, simulation results suggest that significant limitations exist for intermediate enrichment levels due to distortions to the delayed neutron time profile caused by neutron reflection in the shielding.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of a collimated neutron imager for low-rate fast neutron imaging

Spatial localization of special nuclear materials (SNM) via their neutron signatures amidst background requires knowledge of the background neutron environment or a means of separating a source from background based on low amounts of information. This requirement has created the need for characterizing the spatial distribution of the cosmogenic neutron background. Neutron scatter cameras have been developed and optimized for rapid detection of high activity sources, but have low imaging efficiency, making it difficult to use them to characterize low rate diffuse sources, such as the neutron background. The Low Intensity Neutron Imaging System (LINIS) is a collimated neutron imager that has been designed and optimized for imaging diffuse cosmogenic neutron background in the energy range of 0.5–15 MeV. LINIS operates using 16 liquid scintillation detectors shielded by ultra-high molecular weight polyethylene cylindrical collimators in a staggered orientation and rotates to 7 discrete positions, giving it roughly 2π sensitivity. Finally, LINIS has been characterized using (α, n) and fission neutron sources using two imaging techniques for neutron source localization, simple backprojection and Maximum Likelihood Expectation Maximization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of MCNP thermal scattering laws to inelastic neutron scattering data

Neutron transport computations employ thermal scattering laws (TSLs) to account for the influence of material structure and collective excitations at low energy (≲ 10 eV). Recent work has been undertaken to improve TSL accuracy and expand the number of available materials in the Evaluated Nuclear Data File (ENDF). However, comparison of TSL to measured data is often sparse. In this work, we present a method to evaluate TSL accuracy in the Monte Carlo N-Particle (MCNP) code by simulating inelastic neutron scattering (INS) measurement and comparing to data. The method is briefly described with example application to the recently released ENDF-VIII TSL library for polyethylene as well as a cryogenic PE TSL we are separately developing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental demonstration and modeling of a robotic neutron detector with spectral and directional sensitivity for treaty verification

International safeguards and arms control agreements often require labor-intensive, intrusive onsite inspections to perform verification tasks. The ability to localize a neutron source and/or characterize a neutron field may be imperative for identifying anomalies. We are interested in the role of autonomous mobile robots, which, if designed properly, may be more effective and efficient and less intrusive than their human counterparts. Toward developing such a capability, we, for this study, have constructed the N-SpecDir Bot, comprised of three boron-coated straw detectors azimuthally-distributed within a cylinder of high-density polyethylene, which is mounted on an omni-directional robotic platform. Our N-SpecDir Bot is specifically designed to provide spectral and directional sensitivity, in addition to gross counts, by utilizing the signals from the three detectors. The detection system has been extensively characterized by MCNP modeling, which has been benchmarked to experiments conducted at the Princeton Plasma Physics Laboratory. We demonstrate the spectral and directional sensitivity experimentally and in simulation, and provide a simple yet robust method for directional measurements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Status of the SABRE South experiment at the Stawell underground physics laboratory

The SABRE (Sodium iodide with Active Background REjection) experiments aim to detect an annual rate modulation from dark matter interactions in ultra-high purity NaI(Tl) crystals. The SABRE South experiment is located at the Stawell Underground Physics Laboratory (SUPL), Australia, and is the first deep underground laboratory in the Southern Hemisphere. SABRE South is designed to disentangle seasonal or site-related effects from the dark matter-like modulated signal first observed by DAMA/LIBRA in the Northern Hemisphere using an active veto and muon detection system. It is a partner to the SABRE North effort at the Laboratori Nazionali del Gran Sasso (LNGS). SABRE South is instrumented with ultra-high purity NaI(Tl) crystals immersed in a linear alkyl benzene (LAB) based liquid scintillator veto, further surrounded by passive steel and polyethylene shielding and a plastic scintillator muon veto. Significant work has been undertaken to understand the experimental backgrounds and performance of the crystals. The SABRE South experiment is under construction, and will be commissioned from late 2022 to early 2023. We will present the final design of SABRE South, the status of its construction, its expected background, and its sensitivity to a DAMA/LIBRA like modulation. We will also present recent quenching factor measurements of sodium nuclear recoils in NaI(Tl) crystals measured at the Heavy Ion Accelerator Facility, and a report on the status of SUPL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a compact fast-neutron spectrometer for nuclear emergency response applications

We have developed a Compact Fast Neutron Spectrometer (CFNS) for passive assay of special nuclear material (SNM) through the observation of fast neutrons. The CFNS consists of eight organic glass scintillators (OGS) coupled to silicon photomultipliers and a waveform digitizer, which are integrated within a human-portable box. The CFNS determines the neutron energy profile by spectrum unfolding using the Maximum-Likelihood Expectation Maximization method. The detector acquisition system was optimized to have a dynamic range of up to 10 MeV neutron energy. Bulk special nuclear material (SNM) measurements from the National Criticality Experiments Research Center were analyzed for SNM validation/examination. Additionally, the results show that the CFNS can be used to distinguish between fission and (α, n) neutron emitters, regardless of intervening material type (Cu and polyethylene) and thickness, by taking the ratio of neutron counts at different regions in the unfolded energy spectrum. Additionally, by fitting an exponential curve to the unfolded energy spectrum of PuO 2 and Pu neutron emitters, the CFNS showed the ability of distinguishing between pure Pu oxide, pure Pu metal and mixed oxide-metal configurations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 6 Li-loaded pulse-shape-discriminating plastic scintillators

Lithium-loaded organic plastic scintillators combine sensitivity to γ rays with the ability to detect both fast and slow neutrons, making them valuable for applications in nuclear security and in basic nuclear and particle physics. The goal of this work is to characterize the neutron response of two custom lithium-loaded organic plastic scintillators developed at Lawrence Livermore National Laboratory. Both are ternary polystyrene-based formulations containing 1.5 wt.% 6 Li salts of isobutyric acid, but they differ in their primary and secondary dye compositions: one uses m-terphenyl as the primary fluor and with Exalite 404 as the wavelength shifter, whereas the other uses 2,5-diphenyloxazole (PPO) and 9,10-diphenyl-anthracene, respectively. The temporal response of the scintillators was measured via time-correlated single photon counting for γ-ray and neutron events. The proton light yield was measured using the double time-of-flight technique from 1.3 to 15 MeV at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. For the slow neutron response, an AmBe source moderated with polyethylene was used, and the light output from the 6 Li(n,α)t reaction was characterized. Differences in ionization quenching and temporal response were observed between the two materials with the PPO-containing scintillator exhibiting higher ionization quenching. These results provide performance benchmarks that can guide the design and optimization of future lithium-loaded plastic scintillators for use in basic science and applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance evaluation of neutron noise analysis in detecting special nuclear materials

Reliable and rapid inspection techniques play a vital role in preventing illicit trafficking of special nuclear materials. Active interrogation systems using neutrons produced by portable, high-flux deuterium-deuterium or deuterium-tritium neutron generators are being actively developed as a secondary scanning tool for this purpose. In this study, a neutron noise analysis-based approach for detecting unshielded and shielded special nuclear materials by using a pulsed deuterium-tritium neutron generator was evaluated. Here, this approach analyzes the fluctuation of neutron counts. Its performance was quantified with regard to time-to-detection to achieve a minimum probability of detection of 99% and a probability of false alarm of less than 1% considering various amounts of special nuclear materials and different shielding configurations. It was demonstrated that this approach could detect 17 uranium slugs in 5 s given a neutron generator yield of 8.1 × 10 7 n/s. These slugs could be detected within a reasonable time frame (200 s) when they were shielded by 10.16 cm of high-density polyethylene. The results obtained using the neutron noise analysis approach were compared with those obtained using the commonly used differential die-away analysis technique, a sensitive technique for detecting the presence of fissile materials by utilizing the prompt fission neutrons produced when the source neutrons from a neutron generator are completely diminished. For example, the time to detect 2 unshielded uranium slugs was 2.1 s when using the differential die-away analysis technique; it increased to 93 s for the neutron noise analysis approach. Although the noise analysis-based approach exhibits an overall performance which is not as good as that of differential die-away, neutron noise provides an alternative method for effective detection of special nuclear materials.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First demonstration of a triton beam using target normal sheath acceleration

Tritiated titanium targets were irradiated by the short-pulse OMEGA EP laser (1.25 kJ, 10 ps) to generate a laser accelerated pulsed beam of tritons by target normal sheath acceleration. Using a Thomson parabola, the beam was found to contain 10 12 tritons per pulse, with a mean energy of 2.2 MeV and an exponential tail reaching up to 10 MeV. In a separate experiment, the triton beam was directed onto a secondary deuterated polyethylene (CD) target to induce deuterium–tritium (D–T) nuclear reactions. Using neutron time-of-flight spectrometers, approximately 10 8 D–T fusion neutrons were observed per laser pulse. Furthermore, this triton beam presents new research opportunities for the study of the 3 H(t, 2n) 4 He reaction and di-neutron transfers to lithium and beryllium that may produce exotic neutron-rich nuclei of interest to basic nuclear science, astrophysics, and inertial confinement fusion technology.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Creation of a High-Yield AAV Vector Production Platform in Suspension Cells Using a Design-of-Experiment Approach

Recombinant adeno-associated virus (rAAV) vectors are a leading gene delivery platform, but vector manufacturing remains a challenge. New methods are needed to increase rAAV yields and reduce costs. Past efforts to improve rAAV production have focused on optimizing a single variable at a time, but this approach does not account for the interactions of multiple factors that contribute to vector generation. Here, we utilized a design-of-experiment (DOE) methodology to optimize rAAV production in a HEK293T suspension cell system. We simultaneously varied the transgene, packaging, and helper plasmid ratios, the total DNA concentration, and the cell density to systematically evaluate the impact of each variable across 52 conditions. The results revealed a unique set of parameters with a lower concentration of transgene plasmid, a higher concentration of packaging plasmid, and a higher cell density than previously described protocols. Using this DOE-optimized protocol, we achieved unpurified yields approaching 3 × 10 14 viral genomes (VGs)/L of cell culture. Additionally, we incorporated polyethylene glycol (PEG)-based virus precipitation, pH-mediated protein removal, and affinity chromatography to our downstream processing, enabling average purified yields of >1 × 10 14 VGs/L for rAAV-EGFPs across 13 serotypes and capsid variants.

59 BASIC BIOLOGICAL SCIENCES↗

Mixed polyester recycling can enable a circular plastic economy with environmental benefits

The mixed and varied nature of fossil-based and bio-based plastic waste requires complex and costly separations to enable compatibility with recycling technologies. A circular plastic economy based on mixed polyesters through cleaving ester bonds to produce monomers, while re-utilizing bio-based monomers to produce high-quality sustainable plastics, charts an exciting solution. However, the feasibility of such a circular economy solution remains underexplored. Here, in this study, we conducted a techno-economic analysis and life-cycle assessment of three polyester depolymerization recycling processes-methanolysis, glycolysis, and acid hydrolysis-for a mixed feedstock (polyethylene terephthalate [PET], polylactic acid [PLA], and polybutylene adipate terephthalate [PBAT]). Methanolysis outperforms glycolysis and hydrolysis economically and environmentally due to more efficient downstream separations, generating products with a 31% decrease in selling price and 21%-46% reduction in acidification, carcinogenic toxicity, fossil-fuel depletion, global warming potential, particulate formation, and smog formation compared to conventional polyester manufacturing. This study highlights the viability of a circular plastic economy for mixed polyesters via a single chemical recycling process.

09 BIOMASS FUELS↗

Minimum spouting velocity of flat-base spouted fluid bed

Experiments were performed on spout characteristics of a cylindrical spout-fluidized bed (I.D. = 10 cm) with different static heights and two materials (Al 2 O 3 and high density polyethylene). Results of minimum spouting velocity obtained in this study were compared with reported correlations for both spouted and spout-fluidized beds. Considerable discrepancies were found between the values obtained using different model equations as well as with respect to experimental results. Based on the Mathur–Gishler correlation, a new correlation is proposed for calculating the minimum spouting velocity that introduces the ratio U/U mf . It was found that the minimum spouting velocity decreases with increasing fluidizing gas velocity (U/U mf ). The pressure drop at the point of minimum spouting velocity is also correlated using this dimensionless group and is presented in this work. Finally, this investigation demonstrates that the use of correlations reported in the literature that focus primarily on conical bottom spouted beds are not applicable to flat-bottom spouted and spout-fluidized beds.

42 ENGINEERING↗

Connecting radiation-driven changes in structural, thermal, and mechanical properties in several medical device polymers

Stemming from security threats and shortages in supply, a recent push has emerged to develop alternatives to radioisotope Cobalt-60 gamma radiation for sterilization of polymeric medical products, including electron beam (e-beam) and X-ray machine-based sources. However, before large-scale implementation, the effects of these non-isotope-based methods must be thoroughly investigated from several perspectives, involving their potential detrimental effects on the structural, thermal, and mechanical properties of polymers in medical devices. This paper investigates such effects in commonly used medical device polymers, including polypropylene homopolymer (PPH), polyolefin elastomer (POE), low-density polyethylene (LDPE), acrylonitrile butadiene styrene (ABS), and chlorobutyl rubber (CIIR). To connect radiation-driven changes in polymer structural and thermal properties and corresponding changes in mechanical properties, several characterization techniques were utilized, including gel permeation chromatography (GPC), Fourier transform infrared spectroscopy (FTIR), dynamic mechanical analysis (DMA) and differential scanning calorimetry (DSC). We found that the tensile strength of X-ray irradiated PPH, as well as X-ray, e-beam, and gamma irradiated CIIR decreases due to chain scission, which is corroborated by GPC and DMA. The GPC results of LDPE suggest chain scission, but interestingly without a corresponding decline in tensile strength. By comparison, POE and ABS appear to undergo further crosslinking with increasing irradiation dose, which generally strengthens them. Importantly, in the vast majority of the cases, there were small to no changes in properties upon changing radiation technologies (at a given dose), i.e., no radiation source dependence. However, in a few specific cases, radiation method dependencies did arise, for instance, in terms of the molecular weight of PPH being significantly increased upon X-ray irradiation, while the melting temperature, glass transition temperature, and elongation at break reduced compared to gamma. Overall, this study provides valuable insight into radiation-driven chemical and structural changes in polymers that produce changes in physical and functional properties.

36 MATERIALS SCIENCE↗

N 2 O deconstruction of polycyclooctene to generate carbonyl-functionalized macromonomers

Deconstruction of polyolefins into functionalized macromonomers presents a compelling strategy for polyolefin upcycling by creating macromonomers through dehydrogenation/depolymerization. We show that nitrous oxide (N 2 O), a greenhouse gas waste product from the production of nylon, mediates the deconstruction of polycyclooctene (PCOE) and generates carbonyl-functionalized macromonomers. Carbonyl incorporation and macromonomer molar mass were well controlled by reaction time, and subsequent hydrogenation readily removed residual carbon-carbon double bonds. Here, we also demonstrated that the reaction could progress efficiently with substrates of moderate levels of unsaturation, closely mimicking partially dehydrogenated polyethylene. Such carbonyl-functionalized macromonomers could serve as feedstock for preparing vitrimers and other functional polymers.

36 MATERIALS SCIENCE↗

Chain flexibility and glass transition temperatures of poly(n-alkyl (meth)acrylate)s: Implications of tacticity and chain dynamics

The relationship between chain microstructure and glass transition temperature (T g ) is complicated for poly(alkyl methacrylate)s and poly(alkyl acrylate)s. Despite intensive studies, relationships between the structures of these polymers and their properties, including solution characteristics and T g , are still controversial. Solution properties, chain conformations, including Flory's characteristic ratio (C ∞ ), persistence length (l p ), and chain diameters, and T g are reported for series of poly(n-alkyl acrylate)s and poly(n-alkyl methacrylate)s having alkyl side chain lengths (n) ranging from 1 to 10 carbons in length, with uniform and well-characterized tacticities. Chain flexibilities of both series of polymers decrease as n increases, reflecting increased hindrances to rotation about backbone bonds as side chains become longer. Conversely, the T g s for both series of polymers decrease substantially as n increases, reflecting the greater side chain mobilities of long alkyl substituents. For shorter alkyl chain lengths, T g s for the poly(n-alkyl acrylate)s are much lower than for the corresponding poly(n-alkyl methacrylate)s, a difference which has been attributed in the past to the presumed reduced chain flexibility of polymethacrylates due to the presence of the α-methyl substituent. However, contrary to such expectations, C ∞ and l p values for these two series of polymers are nearly identical at a given n value, except for the longest n-alkyl substituents. Instead, the differences in T g may be attributed to the differences in tacticity of the two series – almost ideally atactic for the poly(n-alkyl acrylate)s but high in syndiotacticity for the poly(n-alkyl methacrylate)s. The T g s for the two series of polymers approach that of polyethylene at longer alkyl chain lengths. In addition, the effects of tacticity and chain dynamics on C ∞ , l p , and T g of poly(methyl methacrylate) is discussed.

36 MATERIALS SCIENCE↗

Thermally stable and self-healable lignin-based polyester

The increased use of plastics and the associated environmental impact has catalyzed research on the development of bio-derived polymers. Bio-based polyesters have gained increased attention due to the abundance of their starting materials and ease of processing. Lignin is naturally occurring in biomass with rich carbon content, whose functionality and rigidity make it an ideal bio-derived candidate for bio-based polyesters. Herein, a lignin-based polyester with good thermal stability and self-repairability was synthesized from carboxylated lignin and epoxidized soybean oil. The synthesized lignin/epoxidized soybean oil (ESO) vitrimer was brittle such that its mechanical performance could not be recorded. However, when polyethylene glycol (PEG) was incorporated as a plasticizer, polymer samples exhibited acceptable ductility. From thermomechanical analysis of the synthesized polyesters, the plasticizer did not impair thermal stability of polymers, but greatly enhanced mechanical properties. Notably, all samples exhibited stability at high temperatures, and good glass transition temperatures (51.0 ± 0.9–78.0 ± 1.2 °C). The highest tensile strength (3.983 ± 0.1 MPa) and storage modulus (1463.67 ± 12.6 MPa) were recorded for the polyester containing 6 % w/w PEG. Moreover, the polymer samples exhibited self-healing capability at 180 °C. This work expands on valorization of lignin through the synthesis of bio-derived materials.

36 MATERIALS SCIENCE↗

3D printed polymer gaskets for custom-form batteries

Additive manufacturing (AM) processes, like 3D printing, help to facilitate complex and customizable battery geometries which can provide design freedom and enhance volumetric energy density within electronic devices. AM materials must have the thermal and mechanical properties that enable printability, and when used in batteries, AM materials must also be chemically and electrochemically compatible with the battery chemistry. The compatibility between AM materials and the battery is of particular importance for the cell packaging materials which must be inert and are often overlooked. This study systematically studies AM-compatible polymeric materials for use as gaskets in lithium-ion cells. The materials investigated include three thermoplastics suitable for material extrusion printing: polylactic acid (PLA), polycarbonate, and polypropylene/polyethylene copolymer (PPPEC); and two photoresins suitable for vat photopolymerization (VPP) printing: an acrylate-based photoresin and a polyethylene glycol diacrylate photoresin. The AM gasket materials were tested in comparison to a conventional commercial polypropylene gasket. Mechanical testing (swell measurements and material stiffness) and electrochemical testing (linear sweep voltammetry and galvanostatic cycling of full cells) demonstrated that PLA and the VPP polymers were the least compatible with the lithium-ion battery chemistry, despite their prevalent use in studies of AM batteries, and that PPPEC was the most compatible.

3D printing↗