Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Emrgy 2022 Hydrokinetic Turbine Data - TEAMER Post Access Submission

The data herein contains all data collected and used for the Performance Characterization Testing and Model Calibration of a Vertical Axis Hydrokinetic Turbine. The data includes performance data and durability data for the Hydrokinetic Turbine. The device performance data contains shaft RPM, turbine RPM, power output, flow velocity, pressure, and pressure drop across the turbine. The mechanical durability data includes stress and strain at varied depths and velocities. There is also an FEA analysis included. This TEAMER project was awarded to Emrgy, Inc.in collaboration with Alden Research Laboratory LLC.

16 TIDAL AND WAVE POWER↗

LONG-TERM PERFORMANCE OF SOLID OXIDE STACKS WITH ELECTRODE-SUPPORTED CELLS OPERATING IN THE STEAM ELECTROLYSIS MODE

Performance characterization and durability testing have been completed on two five-cell high-temperature electrolysis stacks constructed with advanced cell and stack technologies. The solid oxide cells incorporate a negative-electrode-supported multi-layer design with nickel-zirconia cermet negative electrodes, thin-film yttria-stabilized zirconia electrolytes, and multi-layer lanthanum ferrite-based positive electrodes. The per-cell active area is 100 cm2. The stack is internally manifolded with compliant mica-glass seals. Treated metallic interconnects with integral flow channels separate the cells. Stack compression is accomplished by means of a custom spring-loaded test fixture. Initial stack performance characterization was determined through a series of DC potential sweeps in both fuel cell and electrolysis modes of operation. Results of these sweeps indicated very good initial performance, with area-specific resistance values less than 0.5 ?.cm2. Long-term durability testing was performed with A test duration of 1000 hours. Overall performance degradation was less than 10% over the 1000-hour period. Final stack performance characterization was again determined by a series of DC potential sweeps at the same flow conditions as the initial sweeps in both electrolysis and fuel cell modes of operation. A final sweep in the fuel cell mode indicated a power density of 0.356 W/cm2, with average per-cell voltage of 0.71 V at a current of 50 A.

08 HYDROGEN↗

Cladding embrittlement during postulated loss-of-coolant accidents.

The effect of fuel burnup on the embrittlement of various cladding alloys was examined with laboratory tests conducted under conditions relevant to loss-of-coolant accidents (LOCAs). The cladding materials tested were Zircaloy-4, Zircaloy-2, ZIRLO, M5, and E110. Tests were performed with specimens sectioned from as-fabricated cladding, from prehydrided (surrogate for high-burnup) cladding, and from high-burnup fuel rods which had been irradiated in commercial reactors. The tests were designed to determine for each cladding material the ductile-to-brittle transition as a function of steam oxidation temperature, weight gain due to oxidation, hydrogen content, pre-transient cladding thickness, and pre-transient corrosion-layer thickness. For short, defueled cladding specimens oxidized at 1000-1200 C, ring compression tests were performed to determine post-quench ductility at {le} 135 C. The effect of breakaway oxidation on embrittlement was also examined for short specimens oxidized at 800-1000 C. Among other findings, embrittlement was found to be sensitive to fabrication processes--especially surface finish--but insensitive to alloy constituents for these dilute zirconium alloys used as cladding materials. It was also demonstrated that burnup effects on embrittlement are largely due to hydrogen that is absorbed in the cladding during normal operation. Some tests were also performed with longer, fueled-and-pressurized cladding segments subjected to LOCA-relevant heating and cooling rates. Recommendations are given for types of tests that would identify LOCA conditions under which embrittlement would occur.

08 HYDROGEN↗

Composite coatings from polycarbosilane derived SiC and Al/SiC cermet active fillers as protective barriers against steel corrosion

Stainless steel is used throughout the world as a structural material. However, it undergoes corrosion damage when exposed to extremely corrosive media, such as the marine environment. An alternative to solve this problem lies in the development of coatings that can withstand extreme conditions but also be easily deposited with inherently corrosion-resistant materials such as silicon carbide (SiC). The present study shows a simple method to produce Al/SiC cermet powders by attrition milling. The resulting cermet powders with a metallic matrix and hemispherical morphology, were employed as fillers in polycarbosilane (PCS) solutions that were sprayed on A304 stainless steel substrates. Al/SiC composite coatings were produced after heating the sprayed suspensions at 700 °C for 1 h in Ar atmosphere. The resulting composite coatings exhibited low surface energies (< 35 mN/m), water contact angles of 53°, and adhesion strength of up to 30 MPa. Finally, corrosion tests were performed in a cyclic corrosion test chamber, showing that these coatings effectively reduced the corrosion rate of stainless steel by 87%, reaching corrosion rate values of 0.007 g/cm 2 year.

36 MATERIALS SCIENCE↗

Film condensation with high heat fluxes and scaled experiments using pure steam for reactor containment cooling

Condensation tests were performed using a newly developed test facility for scaling the passive containment cooling system (PCCS) to a small modular reactor (SMR). The PCCS of the SMR plays a pivotal role in ensuring greater safety, reliability, and compactness than what is afforded by traditional reactors. Therefore, a well-designed PCCS is essential to SMRs. However, previous studies and test data were unsuitable for scaling, due to high variation in the test geometry and operating conditions. This study intends to close this research gap by using a novel designed scaled test facility consisting of vertical condensing test sections featuring 1-, 2-, and 4-inch-diameter condensing tubes with annular water cooling, and by applying superheated and saturated steam with different steam mass flow ranges of 5–25 g/s. Further, the primary test data, including axial temperatures, mass flow rates, and pressures, were used in conjunction with a standard data reduction method to estimate critical parameters such as heat fluxes, heat transfer coefficients, and condensation rates. These scaled test data would support improving empirical correlations and validating condensation models to identify scaling distortion for SMR PCCSs.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Mechanical property degradation and microstructural evolution of cast austenitic stainless steels under short-term thermal aging

Mechanical testing and microstructural characterization were performed on short-term thermally aged cast austenitic stainless steels (CASS) to understand the severity and mechanisms of thermal-aging degradation experienced during extended operation of light water reactor (LWR) coolant systems. Four CASS materials – CF3, CF3M, CF8, and CF8M – were thermally aged for 1500 hours at 290 °C, 330 °C, 360 °C, and 400 °C. All four alloys experienced insignificant change in strength and ductility properties but a significant reduction in absorbed impact energy. The primary microstructural and compositional changes during thermal aging were spinodal decomposition of the δ-ferrite into α/ α`, precipitation of G-phase in the δ-ferrite, segregation of solute to the austenite/ ferrite interphase boundary, and growth of M23C6 carbides on the austenite/ferrite interphase boundary. These changes were shown to be highly dependent on chemical composition, particularly the concentration of C and Mo, and aging temperature. A comprehensive model is being developed to correlate the microstructural evolution with mechanical behavior and simulation for predictive evaluations of LWR coolant system components.

36 MATERIALS SCIENCE↗

A new fuel modeling capability, CTFFuel, with a case study on the fuel thermal conductivity degradation

Here, a new fuel modeling capability, CTFFuel, is developed from the subchannel code, CTF. This code is a standalone interface to the CTF fuel rod models, allowing for fuel rod simulations to be run independently from the fluid. This paper provides an overview of the code with a case study on the thermal conductivity degradation of LWR fuels to demonstrate its capabilities. The modeling of fuel thermal conductivity degradation in the code is improved through the addition of new modeling options to account for the irradiation effects via globally defined parameters. After the initial implementation, a variety of order-of-accuracy tests and code comparisons are performed to test software quality. A controlled analysis is allowed by CTFFuel to verify the numerical scheme of CTF’s conduction solution and to benchmark its fuel temperature predictions against FRAPCON-4.0’s. Overall, the software quality and verification procedure ensures that the new model is coded correctly, that it properly interacts with the rest of the code.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigation of a metallic photonic crystal high power microwave mode converter

It is demonstrated that an L band metallic photonic crystal TEM-TE{sub 11} mode converter is suitable for narrow band high power microwave application. The proposed mode converter is realized by partially filling metallic photonic crystals along azimuthal direction in a coaxial transmission line for phase-shifting. A three rows structure is designed and simulated by commercial software CST Microwave Studio. Simulation results show that its conversion efficiency is 99% at the center frequency 1.58 GHz. Over the frequency range of 1.56-1.625 GHz, the conversion efficiency exceeds 90 %, with a corresponding bandwidth of 4.1 %. This mode converter has a gigawatt level power handling capability which is suitable for narrow band high power microwave application. Using magnetically insulated transmission line oscillator(MILO) as a high power microwave source, particle-in-cell simulation is carried out to test the performance of the mode converter. The expected TE{sub 11} mode microwave output is obtained and the MILO works well. Mode conversion performance of the converter is tested by far-field measurement method. And the experimental result confirms the validity of our design. Then, high power microwave experiment is carried out on a Marx-driven Blumlein water line pulsed power accelerator. Microwave frequency, radiated pattern and power are measured in the far-field region and the results agree well with simulation results. The experiment also reveals that no microwave breakdown or pulse shortening took place in the experimental setup.

36 MATERIALS SCIENCE↗

Effects of temperature and particle size on deposition in land based turbines - article no. 051503

Four series of tests were performed in an accelerated deposition test facility to study the independent effects of particle size, gas temperature, and metal temperature on ash deposits from two candidate power turbine synfuels (coal and petcoke). The facility matches the gas temperature and velocity of modern first stage high pressure turbine vanes while accelerating the deposition process. Particle size was found to have a significant effect on capture efficiency with larger particles causing significant thermal barrier coating (TBC) spallation during a 4 h accelerated test. In the second series of tests, particle deposition rate was found to decrease with decreasing gas temperature. The threshold gas temperature for deposition was approximately 960{sup o}C. In the third and fourth test series, impingement cooling was applied to the back side of the target coupon to simulate internal vane cooling. Capture efficiency was reduced with increasing mass flow of coolant air; however, at low levels of cooling, the deposits attached more tenaciously to the TBC layer. Postexposure analyses of the third test series (scanning electron microscopy and X-ray spectroscopy) show decreasing TBC damage with increased cooling levels.

20 FOSSIL-FUELED POWER PLANTS↗

Benchmark Analysis

Tremendous progress has been achieved in the development of land models and their inclusion in Earth system models (ESMs). However, we still have very limited knowledge on the performance skills of these land models. This chapter introduces benchmark analysis, which is a procedure to measure performance of models against a set of defined standards. The benchmark analysis includes: (1) defining targeted aspects of model performance to be evaluated; (2) testing model performance in comparison with a set of benchmarks; (3) measuring model performance skill through quantitative metrics; and (4) evaluating model performance and offering suggestions for future model improvement.

Luo, Yiqi↗

Results of The Excreta Bioassay Quality Control Program For April 1, 2008 through March 31, 2009

A total of 62 urine samples and 6 spiked fecal samples were submitted during the report period (April 1, 2008 through March 31, 2009) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.3% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 34% of the analyses processed by GEL during the third year of this contract were quality control samples. GEL tested the performance of 21 radioisotopes, all of which met or exceeded the specifications in the Statement of Work within statistical uncertainty. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved (see section on Follow-up on Concerns During the Fourth Contract Year).

61 RADIATION PROTECTION AND DOSIMETRY↗

Syracuse University Test Report On Uptake Factor Resulting From A Dropped Storage Container

Under certain circumstances, powder from an accidently dropped container can become airborne and inhaled by people nearby such as those who are moving the containers. The inhaled fine particles can deposit on respiratory tracts and lungs, causing asthma, lung cancer, and other acute respiratory illnesses and chronic symptoms. The objective of this study was to develop a standard procedure to measure the airborne concentrations of different size particles within the vicinity of a dropped container where a significant portion of the contained powder is ejected. Tungsten oxide (WO{sub 3}) was selected in this study to represent relatively heavy powders (7.16 g/cm3 specific gravity for WO{sub 3}). A typical can with the outer dimensions of 4.25” diameter and 4.875” tall was used as the container. The powder was dropped in two different configurations: 1) contained within a can covered by a lid that has a 0.25” diameter hole, and 2) contained within a can without a lid. The packing volume of the powder was 51.4 in{sup 3} (842.7 cm{sup 3}) and the target mass was 1936 g. The tests were carried out in a full-scale stainless steel environmental chamber with an interior volume of 852 ft{sup 3} (24.1 m{sup 3}). The chamber system includes an internal recirculation loop with a rectangular air diffuser and 10 variable frequency drive fans to provide a typical room air recirculation flow pattern. Two air filters were installed in the chamber air supply duct and return duct to achieve the required low background particle concentration. The initial chamber air conditions were set at 70°F (± 5°F) and 50% (± 10%) RH. A supporting frame and releasing device were designed and built to trigger consistently the dropping of the can at a height of 8 feet from the bottom of the can to the impacting surface. The particle sampling inlet was placed 5 ft above the floor and 6 inches laterally away from the can’s falling path. Concentrations of particles between 0.5 μm and 20 μm were recorded in units of mass and number of particles per unit volume. The data acquisition rate was once every 2 seconds during the first 2 hours and every 20 seconds thereafter. A test procedure was developed and a total of nine drop tests were performed. In most cases (seven tests), the can tipped over after dropping. The can in Test 1 stayed upright. The can in Test 7 showed a special behavior: after the rebound, it turned upside down and stayed upright. Major findings are summarized below: The amount of spilled powder varied from 0.12 g to 252.35 g and the non-recovered powder varied from 0.11 g to 1.18 g. The corresponding percentage of the spilled powder ranged from 0.01% to 13%;The peak value of particle number concentration after the dropping of the can occurred at approximately 0.9 μm particle size per measured data of individual channels. The peak value of particle mass concentration occurred in the range of 4.3 - 10 μm particle size per grouped data calculated from the measured data with the exception of Test 4 where a different batch powder with unexpectedly different bulk density and particle size distribution; After the dropping of the can, the total airborne mass concentrations ranged from 0.03 to 0.35 mg/m{sup 3}, while the total airborne number concentrations ranged from 2 to 125 #/cm{sup 3} except for Test 4. The number concentration in Test 4 was 1 or 2 orders of magnitude less than those of other tests because the powder was from a different batch. However, its mass concentration was comparable to that in Test 7 because relatively more big airborne particles were detected in Test 4. In general, tests with lid (Test 5, 6, 7 and 8) had smaller concentrations than tests without lid (Test 0, 1, 2, and 3). The influence of lid was not as prominent as the powder (Test 4). However, this needs more tests for verification; The ratio of airborne mass to non-recovered mass ranged from 0.1% to 2%. This means that it is challenging to use this method to check the mass balance, while the uptake factor and associated inhalation exposure can be readily assesse; The calculated cumulative uptake mass within first 10 minutes after the dropping of the can for each test was within the range of 0.002 mg to 0.035 mg. Assuming a breathing rate of 1.2 m{sup 3}/h, the uptake factor during the first 10 minutes was calculated to be between 10{sup -9} and 2×10{sup -8} in reference to the amount loaded; or between 10{sup -8} and 6×10{sup -5} in reference to the amount spilled. The experimental results of this study will be useful for standardizing the test method and provide data for estimating the exposure and associated risk to building occupants in the case of an accidental dropping of heavy powder containers.

42 ENGINEERING↗

In-cell Re-fabrication and Loss-of-coolant Accident (LOCA) Testing of High Burnup Commercial Spent Fuel

A high burnup commercial spent fuel segment was re-fabricated into a pressurized test train for fuel safety testing in the Irradiated Fuels and Examination Laboratory (IFEL) hot cell facility at Oak Ridge National Laboratory. Descriptions of the in-cell re-fabrication capabilities and assembly of the loss-of-coolant-accident (LOCA) test train are provided. An in-cell integral LOCA test was performed in the Severe Accident Test Station (SATS) by subjecting the fuel segment to a steam environment, internal pressure, temperatures up to 1200 ºC, and water quench.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Human-in-the-loop Sensing and Control for Commercial Building Energy Efficiency and Occupant Comfort

Most of the existing heating, ventilation and air conditioning (HVAC) systems in commercial buildings operate in a conservative manner by assuming maximum occupancy in each room during pre-specified periods of the week, leading to significant energy being wasted as rooms are over-conditioned compared to the actual requirements of the occupants. Though critical, our understanding of occupancy patterns and thermal comfort needs of the occupants in commercial buildings is lacking and it is well known that both of these quantities are stochastic and time-varying, thus requiring sensing solutions to estimate them. This project had the goal of designing, implementing and evaluating a hardware and software solution to ameliorate this challenge. In particular, a depth camera (one whose pixels reveal distance from the camera as opposed to color values) placed on doorways is used to detect entrance and exit events from thermal zones in the building, and thereby estimate their occupancy levels. This information is then fed to a novel control algorithm that can, through interactions with the HVAC system, learn how to provide control inputs that maximize comfort and minimize energy waste. The resulting system represents a significant improvement over existing controllers for commercial HVAC systems and allowed us to improve our understanding of the design of future human-in-the-loop control solutions. For this solution to be feasible, the project had target metrics for its performance and cost. In particular, entrance and exit events for occupants moving about the building would need to be detected with an accuracy higher than 97%; and the resulting control inputs derived from this information would need to lead to approximately 10% energy savings compared to a schedule-based controller. Furthermore, regarding the final hardware design, the project had a target bill of materials (BOM) cost for the sensing solution of less than US$200 per unit while using less than 25W of power on average. All of these target metrics were met or exceeded by our final proposed solution. We performed evaluations by deploying the system in over 20 rooms of different types across 6 commercial buildings in Pittsburgh, PA over the course of three years, and performing targeted controlled experiments to test its performance along the different metrics. The human-in-the-loop control solutions (both hardware and software) developed through this project are expected to lead to significant improvements in the comfort and energy efficiency of HVAC systems used in commercial buildings. The insights we developed through the project pave the way to HVAC systems that can condition interior spaces according to their real-time utilization and the thermal comfort needs of the occupants, thereby reducing energy use. They also open up a new learning-based way of configuring HVAC controllers without having to manually fine-tune them for each building. These innovations can significantly increase the adoption of novel control solutions by the industry and thereby save resources and reduce costs of operation.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Structural Evaluation Test Unit (SETU) Benchmark Test Results

A series of extensively instrumented tests was performed on the Structural Evaluation Test Unit in the early 1990s. The purpose of these tests was to determine the response of a minimally designed cask to impacts that were more severe than the design basis impact. This test series provides an excellent opportunity for benchmarking explicit dynamic finite element analysis programs for behaviors that may be experienced by casks during regulatory and extra-regulatory impact events. This report provides the results of the four tests that were conducted. It is meant to go along with a companion report that defines the benchmark problem and gives the locations for the instrumentation and inspection points.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Structural Evaluation Test Unit (SETU) Benchmark Problem Statement

A series of extensively instrumented tests was performed on the Structural Evaluation Test Unit in the early 1990s. The purpose of these tests was to determine the response of a minimally designed cask to impacts that were more severe than the design basis impact. This test series provides an excellent opportunity for benchmarking explicit dynamic finite element analysis programs for behaviors that may be experienced by casks during regulatory and extra-regulatory impact events. This report provides the parameters of the test unit, the locations of instrumentation, the locations of inspection points, and the parameters of the four tests that were conducted. A companion report provides the results of the tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of the Excreta Bioassay Quality Control Program For April 1, 2006 Through March 31, 2007

A total of 66 urine samples, 6 blank fecal and 6 spiked artificial fecal samples were submitted during the report period (April 1, 2006 through March 31, 2007) to General Engineering Laboratories, South Carolina by the Hanford Internal Dosimetry Program (IDP) to check the accuracy, precision, and detection levels of their analyses. Urine analyses for tritium, Sr, 238Pu, 239Pu, 241Am, 243Am 235U, 238U, elemental uranium and fecal analyses for 241Am, 238Pu and 239Pu were tested this year. The number of QC urine samples submitted during the report period represented 1.7% of the total samples submitted. In addition to the samples provided by IDP, GEL was also required to conduct their own QC program, and submit the results of analyses to IDP. About 36% of the analyses processed by GEL during the second year of this contract were quality control samples. GEL tested the performance of 16 radioisotopes, all of which met or exceeded the specifications in the Statement of Work. IDP concluded that GEL was performing well for all analyses tested, and concerns identified earlier were satisfactorily resolved.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Membranes for corrosive oxidations. Final CRADA report.

The objective of this project is to develop porous hydrophilic membranes that are highly resistant to oxidative and corrosive conditions and to deploy them for recovery and purification of high tonnage chemicals such as hydrogen peroxide and other oxychemicals. The research team patented a process for membrane-based separation of hydrogen peroxide (US Patent No. 5,662,878). The process is based on using a hydrophilic membrane to separate hydrogen peroxide from the organic working solution. To enable this process, a new method for producing hydrophilic membrane materials (Patent No.6,464,880) was reported. We investigated methods of producing these hydrophilic materials and evaluated separations performance in comparison to membrane stability. It was determined that at the required membrane flux, membrane stability was not sufficient to design a commercial process. This work was published (Hestekin et al., J. Membrane Science 2006). To meet the performance needs of the process, we developed a membrane contactor method to extract the hydrogen peroxide, then we surveyed several commercial and pre-commercial membrane materials. We identified pre-commercial hydrophilic membranes with the required selectivity, flux, and stability to meet the needs of the process. In addition, we invented a novel reaction/separations format that greatly increases the performance of the process. To test the performance of the membranes and the new formats we procured and integrated reactor/membrane separations unit that enables controlled mixing, flow, temperature control, pressure control, and sampling. The results were used to file a US non-provisional patent application (ANL-INV 03-12). Hydrogen peroxide is widely used in pulp and paper applications, environmental treatment, and other industries. Virtually all hydrogen peroxide production is now based on a process featuring catalytic hydrogenation followed by auto-oxidation of suitable organic carrier molecules. This process has several drawbacks, particularly in the extraction phase. One general disadvantage of this technology is that hydrogen peroxide must be produced at large centralized plants where it is concentrated to 70% by distillation and transported to the users plant sites where it is diluted before use. Advanced membranes have the potential to enable more efficient, economic, and safe manufacture of hydrogen peroxide. Advanced membrane technology would allow filtration-based separation to replace the difficult liquid-liquid extraction based separation step of the hydrogen peroxide process. This would make it possible for hydrogen peroxide to be produced on-site in mini-plants at 30% concentration and used at the same plant location without distillation and transportation. As a result, production could become more cost-effective, safe and energy efficient.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗