Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Particle accelerator sciences”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

A parallel variable population multi-objective optimizer for accelerator beam dynamics optimization

The simultaneous optimization of multiple objective functions is needed in many particle accelerator applications. In this paper, we present a parallel evolution based multi-objective optimizer that uses a variable population from generation to generation and an external storage to save good solutions. Two heuristic optimization methods, one uses the unified differential evolution and the other uses the real-coded genetic algorithm, are included in the optimizer to generate next generation candidate solutions, and are compared in the test examples. Finally, as an application, we applied this optimizer to the beam dynamics design optimization of a photoinjector and attained the optimal front solutions after 200 generations with the unified differential evolution offspring production scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Silicon control of strontium and cesium partitioning in hydroxide-weathered sediments

Sorption of cesium and strontium during weathering of uncontaminated sediments from the Hanford Site was studied under geochemical conditions chosen to model that of high level radioactive waste leachate at Hanford. Based on prior studies of a range of model clay mineral systems, we postulated that Cs and Sr uptake in the sediments would reflect concurrent and competitive adsorption and co-precipitation effects. Batch experiments were conducted from 0 to 374 d at 298 K to measure long-term kinetics of Cs and Sr uptake to and release from three representative Hanford Site sediments; Ringold silt (RS), Hanford fine sand (HF), and Hanford coarse sand (HC). Sorbent affinity for Cs decreased in the order RS >HF > HC. Similar trends were observed for Sr at early times, but all sediments showed similar Sr sorption capacities after several months reaction time. Strontium uptake by all sediments exceeded that of Cs at nearly all reaction times. After 374 d, the total amount of Cs and Sr sorbed in all systems ranged from 15-37% and 80-93% of the initial concentrations, respectively. Although time-dependent trends for Cs uptake were not clearly evident, the fraction of nonexchangeable Cs increased slightly over time despite fluctuations. Strontium became progressively recalcitrant to desorption after 92 d, suggesting that coprecipitation in neoformed phases may be a significant sequestration mechanism for Sr in sediments of the Hanford vadose zone. SEM-EDS showed formation of Cs and Sr containing secondary solid phases after 183 d. Synchrotron μ-XRF, μ-XRD identified these phases as cancrinite and sodalite. Results indicate that while both Sr and Cs are incorporated into neo-formed precipitates, Sr uptake and lability is more sensitively dependent on mineral transformation reactions in the sediments, whereas Cs uptake is strongly influenced by adsorption, probably associated with high-affiinity and edge sites of native micaceous minerals.

neoformed precipitates↗

Mapping of RBE-Weighted Doses Between HIMAC- and LEM-Based Treatment Planning Systems for Carbon Ion Therapy

Purpose: A method was developed to convert clinically prescribed RBE (Relative Biological Effectiveness)-weighted doses from the approach used at the Heavy-Ion Medical Accelerator (HIMAC) at the National Institute of Radiological Science, Chiba, Japan, to the LEM (Local Effect Model)-based TReatment planning for Particles (TRiP98) approach used in the pilot project at the GSI Helmholtzzentrum, Darmstadt, and the Heidelberg Ion-Beam Therapy Center (HIT). Methods and Materials: The proposed conversion method is based on a simulation of the fixed spread-out Bragg peak (SOBP) depth dose profiles as used for the irradiation at HIMAC by LEM/TRiP98 and a recalculation of the resulting RBE-weighted dose distribution. We present data according to the clinical studies conducted at GSI in the past decade (LEM I), as well as data used in current studies (refined LEM version: LEM IV). Results: We found conversion factors (RBE-weighted dose LEM/RBE-weighted dose HIMAC) reaching from 0.4 to 2.0 for prescribed carbon ion doses from 1 to 60 Gy (RBE) for SOBP extensions ranging from 20 to 120 mm according to the HIMAC approach. A conversion factor of 1.0 was found for approximately 5 Gy (RBE). The conversion factor decreases with increasing prescribed dose. Slightly smaller values for the LEM IV-based data set compared with LEM I were found. A significant dependence of the conversion factor from the SOBP width could be observed in particular for LEM IV, whereas the depth dependence was found to be small. Conclusions: For the interpretation and comparison of clinical trials performed at HIMAC and GSI/HIT, it is of extreme importance to consider these conversion factors because according to the various methods to determine the RBE-weighted dose, similar dose values might not necessarily be related to similar clinical outcomes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Collimated protons accelerated from an overdense gas jet irradiated by a 1 µm wavelength high-intensity short-pulse laser

We have investigated proton acceleration in the forward direction from a near-critical density hydrogen gas jet target irradiated by a high intensity (10 18 W/cm 2 ), short-pulse (5 ps) laser with wavelength of 1.054 μm. We observed the signature of the Collisionless Shock Acceleration mechanism, namely quasi-monoenergetic proton beams with small divergence in addition to the more commonly observed electron-sheath driven proton acceleration. The proton energies we obtained were modest (~MeV), but prospects for improvement are offered through further tailoring the gas jet density profile. Also, we observed that this mechanism is very robust in producing those beams and thus can be considered as a future candidate in laser-driven ion sources driven by the upcoming next generation of multi-PW near-infrared lasers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Swift heavy ion induced structural changes in CdS thin films possessing different microstructures: A comparative study

This study is carried out to verify the role of thin film microstructure in determining the energy relaxation processes of swift heavy ions in CdS polycrystalline thin films. Two sets of CdS thin film samples, differing in their microstructures, prepared using thermal evaporation and spray pyrolysis, are irradiated with 100 MeV Ag ions using Pelletron accelerator. It is observed that the effects produced differ significantly in the two films. For the evaporated films, defect annealing dominates for lower irradiation fluences but at higher fluences the effects due to defect creation and their migration are dominant. A transformation from the metastable cubic to hexagonal phase together with the creation of a significant amount of compressive strain is seen in these films for irradiation at the highest fluence. The optical absorption of the samples shows an increase in band gap from 2.34 eV for the as grown film to 2.43 eV for the sample irradiated at the highest fluence that is further confirmed by photoluminescence (PL) studies. In contrast, the spray deposited samples undergo a significant improvement of crystalline quality for all fluences as shown by an increase in x-ray diffraction peak intensity, sharper optical absorption edge, reduction in defect PL intensity, and removal of asymmetry in the line shape of the longitudinal optical phonon on its lower wavenumber side in Raman spectra.

36 MATERIALS SCIENCE↗

Computation of Ion Charge State Distributions After Inner-Shell Ionization In Ne, Ar And Kr Atoms Using Monte Carlo Simulation

Atomic reorganization starts by filling the initially inner-shell vacancy by a radiative transition (x-ray) or by a non-radiative transition (Auger and Coster-Kronig processes). New vacancies created during this atomic reorganization may in turn be filled by further radiative and non-radiative transitions until all vacancies reach the outermost occupied shells. The production of inner-shell vacancy in an atom and the de-excitation decays through radiative and non-radiative transitions may result in a change of the atomic potential; this change leads to the emission of an additional electron in the continuum (electron shake-off processes). In the present work, the ion charge state distributions (CSD) and mean atomic charge ions produced from inner-shell vacancy de-excitation decay are calculated for neutral Ne, Ar and Kr atoms. The calculations are carried out using Monte Carlo (MC) technique to simulate the cascade development after primary vacancy production. The radiative and non-radiative transitions for each vacancy are calculated in the simulation. In addition, the change of transition energies and transition rates due to multi vacancies produced in the atomic configurations through the cascade development are considered in the present work. It is found that considering the electron shake--off process and closing of non-allowed non-radiative channels improves the results of both charge state distributions (CSD) and average charge state. To check the validity of the present calculations, the results obtained are compared with available theoretical and experimental data. The present results are found to agree well with the available theoretical and experimental values.

36 MATERIALS SCIENCE↗

Band offsets of La{sub 2}O{sub 3} on (0001) GaN grown by reactive molecular-beam epitaxy

La{sub 2}O{sub 3} films were prepared on (0001)-oriented GaN substrates via reactive molecular-beam epitaxy. Film orientation and phase were assessed using reflection high-energy electron and X-ray diffraction. Films were observed to grow as predominantly hexagonal La{sub 2}O{sub 3} for thicknesses less than 10 nm while film thickness greater than 10 nm favored mixed cubic and hexagonal symmetries. Band offsets were characterized by X-ray photoelectron spectroscopy on hexagonally symmetric films and valence band offsets of 0.63 {+-} 0.04 eV at the La{sub 2}O{sub 3}/GaN interface were measured. A conduction band offset of approximately 1.5 eV could be inferred from the measured valence band offset.

36 MATERIALS SCIENCE↗

Management, Analysis, and Visualization of Experimental and Observational Data – The Convergence of Data and Computing

Scientific user facilities—particle accelerators, telescopes, colliders, supercomputers, light sources, sequencing facilities, and more—operated by the U.S. Department of Energy (DOE) Office of Science (SC) generate ever increasing volumes of data at unprecedented rates from experiments, observations, and simulations. At the same time there is a growing community of experimentalists that require real-time data analysis feedback, to enable them to steer their complex experimental instruments to optimized scientific outcomes and new discoveries. Recent efforts in DOE-SC have focused on articulating the data-centric challenges and opportunities facing these science communities. Key challenges include difficulties coping with data size, rate, and complexity in the context of both real-time and post-experiment data analysis and interpretation. Solutions will require algorithmic and mathematical advances, as well as hardware and software infrastructures that adequately support data-intensive scientific workloads. This paper presents the summary findings of a workshop held by DOE-SC in September 2015, convened to identify the major challenges and the research that is needed to meet those challenges.

Bethel, E. Wes↗

SU-E-J-48: Imaging Origin-Radiation Isocenter Coincidence for Linac-Based SRS with Novalis Tx

Purpose To implement and evaluate an image-based Winston-Lutz (WL) test to measure the displacement between ExacTrac imaging origin and radiation isocenter on a Novalis Tx system using RIT V6.2 software analysis tools. Displacement between imaging and radiation isocenters was tracked over time. The method was applied for cone-based and MLC-based WL tests. Methods The Brainlab Winston-Lutz phantom was aligned to room lasers. The ExacTrac imaging system was then used to detect the Winston- Lutz phantom and obtain the displacement between the center of the phantom and the imaging origin. EPID images of the phantom were obtained at various gantry and couch angles and analyzed with RIT calculating the phantom center to radiation isocenter displacement. The RIT and Exactrac displacements were combined to calculate the displacement between imaging origin and radiation isocenter. Results were tracked over time. Results Mean displacements between ExacTrac origin and radiation isocenter were: VRT: −0.1mm ± 0.3mm, LNG: 0.5mm ± 0.2mm, LAT: 0.2mm ± 0.2mm (vector magnitude of 0.7 ± 0.2mm). Radiation isocenter was characterized by the mean of the standard deviations of the WL phantom displacements: σVRT: 0.2mm, σLNG: 0.4mm, σLAT: 0.6mm. The linac couch base was serviced to reduce couch walkout. This reduced σLAT to 0.2mm. These measurements established a new baseline of radiation isocenter-imaging origin coincidence. Conclusion The image-based WL test has ensured submillimeter localization accuracy using the ExacTrac imaging system. Standard deviations of ExacTrac-radiation isocenter displacements indicate that average agreement within 0.3mm is possible in each axis. This WL test is a departure from the tradiational WL in that imaging origin/radiation isocenter agreement is the end goal not lasers/radiation isocenter.

60 APPLIED LIFE SCIENCES↗

SU-F-T-464: Development of a Secondary Check Procedure to Evaluated Flatness and Symmetry Discrepancies Detected During Daily Morning QA

Purpose: A daily QA device is used to monitor output, flatness and symmetry constancy for all linac photon and electron energies. If large deviations from baseline in flatness or symmetry are reported it becomes necessary to crosscheck the measurements with a second device. Setting up another device such as Matrixx (IBA Dosimetry) can be time consuming, due to its warm-up time, and trained personnel may not be readily available to analyze the results. Furthermore, this discrepancy is frequently isolated to a single energy. Unaffected energies could still be used, avoiding further patient delays, if a method to gather data for offline analysis could be developed. We find that optically stimulated luminescent dosimeters (OSLDs) provide a quick, simple, and inexpensive solution to this important clinical problem. Methods: The exact geometry of the detectors on the daily tracker (Keithley Therapy Beam Evaluator) was reproduced by placing nanoDot OSLDs (Landauer) on a solid water phantom. A combination of bolus and solid water was placed on top to provide buildup and prevent air gaps. Standard daily measurements of output, flatness and symmetry were taken for 2 photon energies (6x,10x) and 5 electron energies (6e,9e,12e,15e,18e) using the tracker. These measurements were then repeated with the OSLD phantom. Results: The time it took to set up the OSLD phantom was comparable to that of the tracker. The inline and crossline OSLD phantom measurements of flatness and symmetry agreed with the tracker results to within 2%. Conclusion: OSLDs provide a good solution for a quick second check when questionable flatness and symmetry results are detected with the tracker during daily QA.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-05: Clinical Impact of MLC Tracking for Lung SABR

Purpose: The objective of this study was to investigate the dosimetric benefits of multi-leaf collimator (MLC) tracking for lung SABR treatments in end-to-end clinically realistic planning and delivery scenarios. Methods: The clinical benefits of MLC tracking were assessed using previously delivered treatment plans and physical experiments. The 10 most recent single lesion lung SABR patients were re-planned following a 4D-GTV-based real-time adaptive protocol (PTV defined as the end-of-exhalation GTV plus 5.0 mm margins). The plans were delivered on a Trilogy Varian linac. Electromagnetic transponders (Calypso, Varian Medical Systems, USA) were embedded into a programmable moving phantom (HexaMotion platform) tracked with the Varian Calypso system. For each physical experiment, the MLC positions were collected and used as input for dose reconstruction. For both planned and physical experiments, the OAR dose metrics from the conventional and real-time adaptive SABR plans (Mean Lung Dose (MLD), V20 for lung, and near-maximum dose (D2%) for spine and heart) were statistically compared. The Wilcoxon test was used to compare plan and physical experiment dose metrics. Results: While maintaining target coverage, percentage reductions in dose metrics to the OARs were observed for both planned and physical experiments. Comparing the two plans showed MLD percentage reduction (MLDr) of 25.4% (absolute differences of 1.41 Gy) and 28.9% (1.29%) for the V20r. D2% percentage reduction for spine and heart were respectively 27.9% (0.3 Gy) and 20.2% (0.3 Gy). For the physical experiments, MLDr was 23.9% (1.3 Gy), and V20r 37.4% (1.6%). D2% reduction for spine and heart were respectively 27.3% (0.3 Gy) and 19.6% (0.3 Gy). For both plans and physical experiments, significant OAR dose differences (p<0.05) were found between the conventional SABR and real-time adaptive plans. Conclusion: Application of MLC tracking for lung SABR patients has the potential to reduce the dose to OARs during radiation therapy.

60 APPLIED LIFE SCIENCES↗

Precise polarization measurements via detection of compton scattered electrons

The Qweak experiment at Jefferson Lab aims to make a 4% measurement of the parity-violating asymmetry in elastic scattering at very low Q{sup 2} of a longitudinally polarized electron beam off a proton target. One of the dominant experimental systematic uncertainties in Qweak will result from determining the beam polarization. A new Compton polarimeter was installed in the fall of 2010 to provide a non-invasive and continuous monitoring of the electron beam polarization in Hall C at Jefferson Lab. The Compton-scattered electrons are detected in four planes of diamond micro-strip detectors. We have achieved the design goals of <1% statistical uncertainty per hour and expect to achieve <1% systematic uncertainty.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Community Project for Accelerator Science and Simulation-3

The UCLA Plasma Simulation Group is a major partner of the “Community Petascale Project for Accelerator Science and Simulation”. This is the technical progress report for the UCLA effort. The UCLA effort is organized into HEP and ASCR activities.

43 PARTICLE ACCELERATORS↗

Status of FNAL and the PIP-II Project

Outline: Fermilab at a Glance; LBNF/DUNE/PIP PIP-II: Context and Science Objectives; PIP -II Project Overview; International Partnerships; Summary

43 PARTICLE ACCELERATORS↗

Management, Analysis, and Visualization of Experimental and Observational Data -- The Convergence of Data and Computing

Scientific user facilities---particle accelerators, telescopes, colliders, supercomputers, light sources, sequencing facilities, and more---operated by the U.S. Department of Energy (DOE) Office of Science (SC) generate ever increasing volumes of data at unprecedented rates from experiments, observations, and simulations. At the same time there is a growing community of experimentalists that require real-time data analysis feedback, to enable them to steer their complex experimental instruments to optimized scientific outcomes and new discoveries. Recent efforts in DOE-SC have focused on articulating the data-centric challenges and opportunities facing these science communities. Key challenges include difficulties coping with data size, rate, and complexity in the context of both real-time and post-experiment data analysis and interpretation. Solutions will require algorithmic and mathematical advances, as well as hardware and software infrastructures that adequately support data-intensive scientific workloads. This paper presents the summary findings of a workshop held by DOE-SC in September 2015, convened to identify the major challenges and the research that is needed to meet those challenges.

Bethel, E. Wes↗

Development of interatomic potential and effect of ordering on defect properties in CrMnV

Developing materials that can withstand extreme environments, such as high radiation doses and elevated temperatures, is crucial for next-generation particle accelerators, including the 2.4 MW Long-Baseline Neutrino Facility. High-Entropy Alloys have emerged as promising candidates for beam window materials due to their superior mechanical strength, corrosion resistance, and radiation tolerance. In this study, we focus on the Cr–Mn–V alloy system, developing and employing machine-learning interatomic potentials (MLIPs) to investigate the formation of an ordered phase and its influence on defect properties. Using hybrid Monte Carlo-Molecular Dynamics simulations, we observe the formation of a B2-ordered phase at lower temperatures, consistent with Density Functional Theory (DFT) predictions. Ordered structures display a bimodal distribution of migration energies and reduced mean square displacement values, indicating suppressed vacancy diffusion. Our results also show that the migration energy barrier varies based on the atomic species, with Mn and V exhibiting the highest and lowest average barriers, respectively. These findings suggest that atomic ordering inhibits defect mobility, potentially enhancing the radiation resistance of CrMnV alloys. The validated MLIP provides a reliable framework for simulations that are faster than traditional DFT while maintaining the accuracy required to study defect and ordering properties.

36 MATERIALS SCIENCE↗