Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRECESSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Design and performance of an in-vacuum, magnetic field mapping system for the Muon g-2 experiment

The E989 Muon g-2 experiment at Fermilab aims to measure the anomalous magnetic moment, a$_\mu$, of the muon with a precision of 140 parts-per-billion. This requires a precise measurement of both the anomalous spin precession frequency, $\omega_a$, and the average magnetic field in terms of the equivalent, free proton Larmor frequency, $\omega_p$. The measurement of $\omega_p$ with a total systematic uncertainty of 70 parts-per-billion involves a combination of various NMR probes. There are 378 probes in fixed locations constantly monitoring field drifts. A water-based probe provides the calibration in terms of $\omega_p$. A crucial element for the multi-step measurement of $\omega_p$ is the regular mapping of the magnetic field over the muon storage region. The former E821 experiment at Brookhaven employed an in-vacuum field mapping system equipped with 17 NMR probes, which was developed by the University of Heidelberg. We have refurbished and upgraded this system with new probes and electronics. The upgrades include a new communication scheme incorporating time-division multiplexing to separate the important NMR reference clock from the data communication. The addition digitization of the NMR signals replaced the hardware-implemented zero-crossing counting of the E821 system. The digitized signals offer new capabilities in the NMR frequency analysis and its related systematic uncertainties. While the mechanical systems that move the field mapper around the ring have been mostly refurbished, the motion control system was completely replaced with a custom-built electronics centered around a commercial Galil motion controller. Both the field mapping NMR system and its motion control were successfully commissioned at Fermilab and have been in reliable operation during the first data taking periods. This article provides details of the upgrades of the field mapper and its performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On Xenon Fission Product Poisoning

We all appreciate the special role Xenon-135 plays in reactor transients. Unless there is sufficient reactivity override, on shutdown a conventional reactor cannot immediately restart because of the buildup of strongly absorbing Xenon from Iodine decay and the absence of neutron flux to continue its elimination. We are also aware of how the flux imbalance in a large reactor core gives rise to Xenon induced power precession around the core in unpredictable ways. In addition, with regard to computational methods, we lack readily accessible numerical algorithms enabling reliable characterization of Xenon oscillations with simple models to explain this fundamentally important phenomenon. Nowhere is this more apparent than in the classroom. In this presentation, we first consider a new 12-element comprehensive decay to model Xenon and its corresponding numerical implementation and verification to establish a predictive model of Xenon buildup in a constant flux. We then follow with a reduced self-consistent flux model in an infinite reactor- a model not found in textbooks. This presentation should appeal to those interested in developing high order numerical methods for reactor transients.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Why is the Muon g-2 Experiment Shifting Time?

Scientists on Fermilab's Muon g-2 experiment are using a finely tuned clock to precisely measure how fast the muon — a heavy cousin of the electron — precesses, or wobbles, in the presence of a magnetic field. To remove subconscious bias from the experiment's measurements, in March 2018, two Fermilab scientists outside the Muon g-2 collaboration set the clock to a certain frequency. For the period that Muon g-2 is taking data, only they will know that setting. This bias-removal technique is called clock blinding.

47 OTHER INSTRUMENTATION↗

Electron Microscopic Examination of an Irradiated TRISO Coated Particle of AGR-2 Experiment: AGR2-222-RS019

The transmission electron microscopic (TEM) examination of an irradiated tristructural isotropic (TRISO) coated particle from advanced gas reactor (AGR) 2 fuel Compact 2-2-2 is presented in this report. Compact 2-2-2 refers to the compact in Capsule 2 at Level 2 of Stack 2. The examination on AGR2 222 RS019 is focused on the interface between the silicon carbide (SiC) to inner pyrolytic carbon (IPyC) layer, central part of SiC, and the interface between SiC and outer pyrolytic carbon layer. The SiC grain boundary distribution and associated fission product precipitates were characterized by scanning transmission electron microscopy (STEM) energy dispersive spectroscopy (EDS), and precession electron diffraction (PED) in the transmission electron microscope. Two separate locations on SiC layer were selected for on the basis of the intact of the buffer layer in the irradiated TRISO particle. The key observation in this particle is that the compositional nature of grain boundary precipitates is more complex near IPyC/SiC layer where Pd, Pd-Ag, Pd-U containing precipitates can be observed. However, the compositions of precipitate towards outer most region of SiC mainly contain Pd. Ag has been observed in the IPyC/SiC layer in one of the two locations. Comparison of the results to previously irradiated and analyzed, Variant 3, safety tested AGR-1 TRISO particles (AGR1-433-001 and AGR1 222-RS004) showed the grain boundary distributions have some noticeable differences. The differences in coincident site lattice grain boundary and misorientation angles are possibly inherent to the fabrication process. Neutron irradiation induced void distribution has been found to be nonuniform. A high concentration of smaller voids is found at stacking faults compared to those in the SiC matrix. Larger void sizes are observed in the SiC location that is near to the broken buffer layer. This void size variation with integrity of buffer layer can potentially affect the fission product retention. However, the average void size continuously decreases along the radius of SiC in both locations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An Overview of Neutron Irradiated SiC Layer Behavior using Micro-and Nano-Characterization Techniques

The complexity of fission product distribution and composition within the SiC layer of tristructural isotropic (TRISO) coated particles, irradiation effects on the SiC structure as well as the variable nature of metallic fission product release, has led to the exploration of multiple micro- and nano-characterization techniques. The fine scale of the fission product precipitates necessitates unique learnings and application of electron microscopic techniques with irradiated fuel during the Advanced Gas Reactor (AGR)-1 experiment analysis. A summarized discussion on the specific advanced techniques with associated method development for TRISO coated particles is provided followed by the down selected techniques currently considered to provide the highest impact. Techniques considered are electron probe micro-analyzer (EPMA), scanning transmission electron microscopy (STEM), and Precession electron diffraction (PED). SiC grain boundary characteristics are evaluated due to the mobility of specific fission products through grain boundaries. PED was performed for understanding the role of grain boundary character on fission product transport. One set of comparative analyses between AGR-1 and AGR-2 particles leads to a finding that the AGR-1, high-Ag-retention particle, had statistically more coincidence site lattice (CSL)-related grain boundaries (but fewer low-angle grain boundaries), compared to the AGR-2 particle. This implies that CSL-related grain boundaries may have a direct influence on Ag retention. However, precipitates were found on a relatively small fraction of CSL-related grain boundaries in both particles. In another set of comparison between AGR-1 and AGR-2 particles that were subjected to safety testing, there is significant differences in average SiC grain boundary distributions, but the fission product distributions on these grain boundaries are very similar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Micro- and Nano-techniques for the Study of Fission Product Precipitation in SiC Layer

The complexity of fission product distribution and composition within the SiC layer of tristructural isotropic (TRISO) coated particles, irradiation effects on the SiC structure as well as the variable nature of metallic fission product release, has led to the exploration of multiple micro- and nano-characterization techniques. The fine scale of the fission product precipitates necessitates unique learnings and application of electron microscopic techniques with irradiated fuel during the Advanced Gas Reactor (AGR)-1 experiment analysis. A summarized discussion on the specific advanced techniques with associated method development for TRISO coated particles is provided followed by the down selected techniques currently considered to provide the highest impact. Techniques considered are electron probe micro-analyzer (EPMA), scanning transmission electron microscopy (STEM), and Precession electron diffraction (PED). SiC grain boundary characteristics are evaluated due to the mobility of specific fission products through grain boundaries. PED was performed for understanding the role of grain boundary character on fission product transport. One set of comparative analyses between AGR-1 and AGR-2 particles leads to a finding that the AGR-1, high-Ag-retention particle, had statistically more coincidence site lattice (CSL)-related grain boundaries (but fewer low-angle grain boundaries), compared to the AGR-2 particle. This implies that CSL-related grain boundaries may have a direct influence on Ag retention. However, precipitates were found on a relatively small fraction of CSL-related grain boundaries in both particles. In another set of comparison between AGR-1 and AGR-2 particles that were subjected to safety testing, there is significant differences in average SiC grain boundary distributions, but the fission product distributions on these grain boundaries are very similar.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Search for CPT and Lorentz invariance violation in the muon $g -2$ experiment at Fermilab

The Muon g-2 experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon, $a_{\mu}= (g-2)/2$, to a groundbreaking precision of $140$ ppb, obtaining a near four-fold increase in precision over the previous experiment, E821, at the Brookhaven National Laboratory (BNL). The value of $a_{\mu}$ from BNL currently differs from the Standard Model prediction by $\sim 3.7$ standard deviations, suggesting the potential for new physics and therefore, motivating a new experiment.Because the theory predicts this number with high precision, testing the g-factor through experiment provides a stringent test of the SM and can suggest physics beyond the Standard Model. The goal of the Fermilab Muon $g-2$ experiment is to increase the statistical precision by more than a factor of 20 and reduce systematic errors by a factor of 3. By measuring muon precession rate ($\omega_a$) in an external magnetic field, the anomalous magnetic moment will be calculated. This is an incredibly challenging experiment with a unique opportunity to provide new insight into nature. \\ The $g-2$ data also provides a great opportunity for setting the most stringent limits on some of the Standard Model Extension CPT Lorentz violating (LV) parameters in the muon sector. One of the CPT and Lorentz violating signatures that we can look for using $g-2$ data is a sidereal variation of $\omega_a(t)$. Extensive simulation studies confirm that the sensitivity regarding the sidereal varation roughly scales with $\omega_a$ uncertainty. Hence, the $g-2$ experiment at FNAL should be able to reach limits of $\sim 5\times10^{-25}$ GeV. Because the CPT and LV analyses are essentially studies of variations in $\omega_a$ as a function of time and charge, performing an $\omega_a$ analysis sets the stage for the CPT and LV measurement. This dissertation focuses on the methodology of a fully functioning framework and analyzing the Fermilab Muon $g - 2$ Run 2 data containing $\sim 11$ billion events above an energy threshold of $1.7$~GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vector measurements using a pulsed, optically pumped atomic magnetometer

An atomic magnetometer, and a method for using same is disclosed. The method for measuring an ambient magnetic field uses an atomic magnetometer that has a probe light beam with a probe axis that probes a polarization vector of an atomic population confined within a vapor cell. The method employs one or more measurement cycles. In each measurement cycle, the polarization vector is prepared in an initial state via an optical pumping pulse. The vapor cell is then subjected to the ambient magnetic field, which results in rotation of the polarization vector by Larmor precession. Within the measurement cycle, at a point in time after the polarization vector has been prepared in the initial state, the ambient magnetic field rotates the direction of the polarization vector, and at least one measurement is made of a projection of the Larmor-rotated polarization vector onto the probe axis during or after application of a magnetic waveform.

Schwindt, Peter↗

Investigation of Xenon Oscillations via Point Kinetics

We all appreciate the special role Xenon-135 plays in reactor transients. Unless there is sufficient reactivity override, on shutdown a conventional reactor cannot immediately restart because of the buildup of strongly absorbing Xenon from Iodine decay and the absence of neutron flux to continue its elimination. We are also aware of how the flux imbalance in a large reactor core gives rise to Xenon induced power precession around the core in unpredictable ways. In addition, with regard to computational methods, we lack readily accessible numerical algorithms enabling reliable characterization of Xenon oscillations with simple models to explain this fundamentally important phenomenon. Nowhere is this more apparent than in the classroom. In this presentation, we first consider a new 12-element comprehensive decay model to Xenon and its corresponding numerical implementation and verification to establish a predictive model of Xenon buildup in a constant flux. We then follow with a reduced self-consistent flux model in an infinite reactor- a model not found in textbooks. This presentation should appeal to those interested in developing high order numerical methods for reactor transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Liquid Interfacial Electron Microscopy Identifies Nanogalvanic Corrosion in Pearlitic Steel

The nanoscale mechanisms of localized corrosion in low carbon steels have remained elusive due to the complexity of studying the degradative material behavior at nanoscale solid-liquid interfaces. We identified various steps in the nanogalvanic corrosion processes using in-situ liquid-cell scanning transmission electron microscopy (STEM) using a microfluidic holder by Hummingbird Scientific. Initial work, performed at low magnification, identified the initiation point on a 1018 low-carbon steel surface. This initiation point was determined to be a triple junction of two ferrite grains bridging a cementite grain in contact with a baseline electrolyte of 6 uM CO2 dissolved in a buffered (2.78 uM Na2SO4) aqueous solution, pH 6.1. The pre-etched low-carbon steel surface was prepared using focused ion beam lift-out procedures to extract a cross-section of the low-carbon steel surface, which then was thinned to about 150 nm and transferred to a SiN membrane microfluidic window. The transfer was made using a lift-out needle to attach the low-carbon steel lamella to the corner of the SiN window, and then Pt/C deposition held the lamella in contact with the window while it was released from the lift out needle. To identify the triple point on the low carbon steel lamella, prior to attachment on the SiN window, the sample was characterized for compositional variations with energy dispersive x-ray spectroscopy mapping, grain orientation and phase mapping with precession electron diffraction, and thickness mapping with energy filtered transmission electron microscopy. This pre-characterization prior to the in-situ experiment provided a map of the multiphase and multigrain structure, where the in-situ liquid cell imaging provided a clear understanding of the initiation point on the sample. These data were cross-correlated to paint a holistic picture of the triple junction site, enabling low electron-fluence in-situ snapshot imaging to avoid dominating the native corrosion reactions with effects from the incident electron beam. This initial result identified that localized, nanogalvanic corrosion at the phase interface was the dominant corrosion process in the low-carbon steel, so we next targeted the observation of an array of these nanogalvanic features phase boundaries in a pearlite grain. Near-surface ferrite/cementite phase interfaces that typify pearlitic low-carbon steel were extracted, pre-characterized, and imaged for the in-situ corrosion processes. The sample was a cross-section from a pearlite grain, with alternating ferrite and cementite grains that extended microns down from the pre-etched low-carbon steel pipe surface. After contact with a buffered aqueous solution, the phase boundaries between the ferrite and cementite began to dissolve, with observable material loss and thickness changes in the dark-field and bright-field STEM images. Within minutes, the corrosion front proceeded deeper into the material, claiming a thin layer of ferrite around all exposed phase boundaries before progressing laterally into the ferrite matrix, converting the ferrite to corrosion product normal to each buried cementite grain. Formation of the corrosion product causes a volumetric expansion, creating a lateral wedging force that mechanically ejects the cementite grains from their grooves and leaves behind percolation channels into the steel substructure. Rapid and deleterious, this nanogalvanic corrosion pathway represents an important target for understanding and preventing run-away degradation in this common building material. Observation of this corrosion mechanism was enabled by the combination of pre-characterization using standard structural, grain, and compositional analysis in the TEM, which provides maps for understanding the reaction propagation captured in low-dose, in-situ, liquid-cell STEM.

corrosion↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection and imaging of electric fields, using polarized neutrons

A method and corresponding apparatus are provided for measuring neutron spin precession in an electric field with high sensitivity suitable for practical applications in non-destructive testing, imaging, and the like. Production of a neutron beam with a polarization vector P is followed by transmitting the spin-polarized neutron beam through a sample region in which there is a target generating an electric field, polarization-analyzing the transmitted neutron beam with an analyzing direction orthogonal to P, detecting an intensity of the polarization-analyzed neutron beam; and mapping the detected neutron-beam intensity to a field-strength value for the target electric field.

Jau, Yuan-Yu↗

Muon g-2 Experiment

The Muon g-2 experiment probes the magnetic properties of the muon—a heavy sibling of the electron—in the search for new physics. Muon g-2 (pronounced gee-minus-two) is an international collaboration between Fermilab and dozens of labs and universities in seven countries. The Muon g-2 experiment studies the precession or “wobble” of muons when placed in a magnetic field. Based on what we already know about muons and other particles, scientists can predict with great precision the value of the muons’ wobble. If the experiment comes up with something different, it means that our current understanding of physics is incomplete, and it may indicate the presence of additional particles or hidden subatomic forces. It would open the door to exciting new realms of science.

Fermilab, Fermilab↗

Outgassing of implanted He via short circuit transport along phase and grain boundaries in vapor co-deposited Cu-W nanocomposites

We investigate the response of physical vapor co-deposited copper (Cu)-tungsten (W) nanocomposites to helium (He) implantation. Nuclear reaction analysis (NRA) reveals that a substantial fraction of He implanted into these materials escapes during implantation. Analysis of nanocomposite microstructure shows that the He loss is likely due to its transport out of the material by diffusion along phase and grain boundaries. Lastly, our findings suggest that solid-state interfaces such as phase and grain boundaries are short circuit diffusion pathways for transport of He.

36 MATERIALS SCIENCE↗

Magnetoabsorption and radiation-induced resistance oscillations in two-dimensional electron systems

Magnetoabsorption and resistance oscillations in two-dimensional systems are calculated in the framework of the same theory: the microwave driven Larmor orbit model. On the one hand, this theory allows to obtain resistance oscillations with multiple peaks, depending on the microwave frequency. On the other hand, it permits also to calculate the microwave magnetoabsorption..

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-probability state transfer in spin-1/2 chains: Analytical and numerical approaches

This article is devoted to the development of analytical and numerical approaches to the problem of the end-to-end quantum state transfer along the spin-1/2 chain using two methods: (a) a homogeneous spin chain with week end bonds and equal Larmor frequencies and (b) a homogeneous spin chain with end Larmor frequencies different from inner ones. A tridiagonal matrix representation of the XY Hamiltonian with nearest neighbor interactions relevant to the quantum state transfer is exactly diagonalized for a combination of the preceding two methods. In order to take into account interactions of the remote spins, we used numerical simulations of the quantum state transfer in 10-node chains. We compare the state transfer times obtained using the two preceding methods for chains governed by the both XY and XXZ Hamiltonians and using both nearest neighbor and all-node interactions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of neutron and ion irradiation on the metal matrix and oxide corrosion layer on Zr-1.0Nb cladding alloys

A detailed study has been carried out on recrystallised Zr-1.0Nb alloys corroded and irradiated under different conditions, including ex-autoclave and ex-reactor samples. After 540 days in reactor and damage around 5 dpa, the neutron irradiated sample shows no serious evidence for radiation enhanced corrosion and is still in pre-transition stage. The good corrosion resistance of the neutron irradiated Zr-1.0Nb can be related to the higher volume fraction of tetragonal phase and fewer interconnected nano porosity/cracks in the oxide. This indicates less tetragonal to monoclinic transition, leads to more protective oxide in the neutron irradiated sample, containing little evidence for short circuit paths for the penetration of oxygen or water towards the metal-oxide interface. These observations on a sample with a slow overall oxidation rate are consistent with the hypothesis that interconnected porosity can lead to early transitions and rapid oxidation. Tetragonal oxide can be either stabilised by irradiation, or stabilised by local release of impurity species from SPPs such as dissolution of Fe from Zr-Nb-Fe precipitates or radiation introduced precipitates (RIPs) which is likely to be small β-Nb clusters. The oxide consists of well-aligned columnar-equiaxed microstructure in the autoclave sample while a more complex oxide grain structure was observed in the neutron-irradiated sample. As oxide continues to grow, there are more < a > and < c > loops, dissolved Fe and RIPs in the metal matrix, however, the corrosion rate is low enough for the tetragonal oxide to stabilise and suboxide + Zr(Osat) phases exist for protectiveness, so there is no enhanced corrosion after radiation. In situ ion irradiation in the TEM revealed no visible defect clusters or voids in the oxide, suggesting that radiation damage to the metal matrix rather than oxide may have a stronger effect on corrosion mechanisms after neutron irradiation, however, cascade damages are not visible in this case. Neutron irradiation also seems to have little effect on promoting fast oxidation or dissolution of β-Nb precipitates into the surrounding oxide or metal during irradiation. Furthermore, these results are discussed in the light of the current mechanisms for corrosion of nuclear fuel cladding alloys.

(S)TEM↗

Visualisation of isothermal large coherent structures in a swirl burner

Lean premixed combustion using swirl flame stabilisation is widespread amongst gas turbine manufacturers. The use of swirl mixing and flame stabilisation is also prevalent in many other non-premixed systems. Problems that emerge include loss of stabilisation as a function of combustor geometry and thermo-acoustic instabilities. Coherent structures and their relationship with combustion processes have been a concern for decades due to their complex nature. This paper thus adopts an experimental approach to characterise large coherent structures in swirl burners under isothermal conditions so as to reveal the effects of swirl in a number of geometries and cold flow patterns that are relevant in combustion. Aided by techniques such as Hot Wire Anemometry, High Speed Photography and Particle Image Velocimetry, the recognition of several structures was achieved in a 100 kW swirl burner model. Several varied, interacting, structures developed in the field as a consequence of the configurations used. New structures never observed before were identified, the results not only showing the existence of very well defined large structures, but also their dependency on geometrical and flow parameters. The PVC is confirmed to be a semi-helical structure, contrary to previous simulations performed on the system. The appearance of secondary recirculation zones and suppression of the vortical core as a consequence of geometrical constrictions are presented as a mechanism of flow control. The asymmetry of the Central Recirculation Zone in cold flows is observed in all the experiments, with its elongation dependent on Re and swirl number used. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗