Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITRON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Precision measurement of the decay rate of the negative positronium ion Ps{sup -}

The negative positronium ion Ps{sup -} is a bound system consisting of two electrons and a positron. Its three constituents are pointlike leptonic particles of equal mass, which are subject only to the electroweak and gravitational force. Hence, Ps{sup -} is an ideal object in which to study the quantum mechanics of a three-body system. The ground state of Ps{sup -} is stable against dissociation but unstable against annihilation into photons. We report here on a precise measurement of the Ps{sup -} ground-state decay rate {Gamma}, which was carried out at the high-intensity NEutron induced POsitron source MUniCh (NEPOMUC) at the research reactor FRM II in Garching. A value of {Gamma}=2.0875(50) ns{sup -1} was obtained, which is three times more precise than previous experiments and in agreement with most recent theoretical predictions. The achieved experimental precision is at the level of the leading corrections in the theoretical predictions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transverse polarization of {Lambda} and {bar {Lambda}} hyperons in quasireal photoproduction.

The HERMES experiment has measured the transverse polarization of Lambda and {ovr Lambda} hyperons produced inclusively in quasireal photoproduction at a positron beam energy of 27.6 GeV. The transverse polarization P{sub n}{sup Lambda} of the Lambda hyperon is found to be positive while the observed {ovr Lambda} polarization is compatible with zero. The values averaged over the kinematic acceptance of HERMES are P{sub n}{sup Lambda} =0.078 {+-} 0.006(stat) {+-} 0.012(syst) and P{sub n}{sup {ovr Lambda}} = -0.025 {+-} 0.015(stat) {+-} 0.018(syst) for Lambda and {ovr Lambda}, respectively. The dependences of P{sub n}{sup Lambda} and P{sub n}{sup {ovr Lambda}} on the fraction zeta of the beam's light-cone momentum carried by the hyperon and on the hyperon's transverse momentum p{sub T} were investigated. The measured Lambda polarization rises linearly with p{sub T} and exhibits a different behavior for low and high values of zeta, which approximately correspond to the backward and forward regions in the center-of-mass frame of the gamma*N reaction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Prospects for detecting dark matter with GLAST in light of the WMAP haze

Observations by the Wilkinson Microwave Anisotropy Probe (WMAP) experiment have identified an excess of microwave emission from the center of the Milky Way. It has previously been shown that this 'WMAP haze' could be synchrotron emission from relativistic electrons and positrons produced in the annihilations of dark matter particles. In particular, the intensity, spectrum, and angular distribution of the WMAP haze is consistent with an electroweak scale dark matter particle (such as a supersymmetric neutralino or Kaluza-Klein dark matter in models with universal extra dimensions) annihilating with a cross section on the order of {sigma}v{approx}3x10{sup -26} cm{sup 3}/s and distributed with a cusped halo profile. No further exotic astrophysical or annihilation boost factors are required. If dark matter annihilations are in fact responsible for the observed haze, then other annihilation products will also be produced, including gamma rays. In this article, we study the prospects for the GLAST satellite to detect gamma rays from dark matter annihilations in the Galactic Center region in this scenario. We find that by studying only the inner 0.1 deg. around the Galactic Center, GLAST will be able to detect dark matter annihilating to heavy quarks, gauge bosons, or tau leptons over astrophysical backgrounds with 5{sigma} (3{sigma}) significance if they are lighter than approximately 320-500 GeV (500-750 GeV). If the angular window is broadened to study the dark matter halo profile's angular extension (while simultaneously reducing the astrophysical backgrounds), weakly interacting, massive particles (WIMPs) as heavy as several TeV can be identified by GLAST with high significance. Only if the dark matter particles annihilate mostly to electrons or muons will GLAST be unable to identify the gamma ray spectrum associated with the WMAP haze.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

PAMELA and ATIC signals from Kaluza-Klein dark matter

We study the possibility that Kaluza-Klein dark matter in a model with one universal extra dimension is responsible for the recent observations of the PAMELA and ATIC experiments. In this model, the dark matter particles annihilate largely to charged leptons, which enables them to produce a spectrum of cosmic ray electrons and positrons consistent with the PAMELA and ATIC measurements. To normalize to the observed signal, however, large boost factors ({approx}10{sup 3}) are required. Despite these large boost factors and significant annihilation to hadronic modes (35%), we find that the constraints from cosmic ray antiproton measurements can be satisfied. Relic abundance considerations in this model force us to consider a rather specific range of masses (approximately 600-900 GeV) which is very similar to the range required to generate the ATIC spectral feature. The results presented here can also be used as a benchmark for model-independent constraints on dark matter annihilation to hadronic modes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Protohalo constraints to the resonant annihilation of dark matter

It has recently been argued that the PAMELA, ATIC, and PPB-BETS data showing an anomalous excess of high-energy cosmic ray positrons and electrons might be explained by dark matter annihilating in the Galactic halo with a cross section resonantly enhanced compared to its value in the primeval plasma. We find that with a very large annihilation cross section the flash of energetic photons and electron-positron pairs expected from dark-matter annihilation in the first protohalos that form at redshift z{approx}40 is likely substantial and observable. As a consequence, bounds on the allowed energy injection into the primordial gas and the energy density of the diffuse gamma-ray background give rise to limits on the low-velocity dark-matter cross section that can be difficult to reconcile with this interpretation of the PAMELA, ATIC, and PPB-BETS results.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-energy neutrino signatures of dark matter

It has been suggested that the excesses of high-energy cosmic ray electrons and positrons seen by PAMELA and the Fermi Gamma Ray Space Telescope are evidence of dark matter annihilation or decay in the Galactic halo. To accommodate these signals however, the final states must be predominantly muons or taus. These leptonic final states will produce neutrinos, which are potentially detectable with the IceCube neutrino observatory. We find that with five years of data, IceCube (supplemented by DeepCore) can significantly constrain the relevant parameter space for both annihilating or decaying dark matter, and may be capable of discovering leptophilic dark matter in the halo of the Milky Way.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Observation of the chi_c2(2P) meson in the reaction gamma gamma -> D Dbar at BaBar

A search for the Z(3930) resonance in {gamma}{gamma} production of the D{bar D} system has been performed using a data sample corresponding to an integrated luminosity of 384 fb{sup -1} recorded by the BABAR experiment at the PEP-II asymmetric-energy electron-positron collider. The D{bar D} invariant mass distribution shows clear evidence of the Z(3930) state with a significance of 5.8{sigma}. We determine mass and width values of (3926.7 {+-} 2.7 {+-} 1.1)MeV/c{sup 2} and (21.3 {+-} 6.8 {+-} 3.6)MeV, respectively. A decay angular analysis provides evidence that the Z(3930) is a tensor state with positive parity and C-parity (J{sup PC} = 2{sup ++}); therefore we identify the Z(3930) state as the {chi}{sub c2}(2P) meson. The value of the partial width {Lambda}{sub {gamma}{gamma}} x {Beta}(Z(3930) {yields} D{bar D}) is found to be (0.24 {+-} 0.05 {+-} 0.04) keV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dark matter in natural supersymmetric extensions of the standard model

We explore the dark matter sector in extensions of the minimal supersymmetric standard model that can provide a good fit to the PAMELA cosmic-ray positron excess, while at the same time addressing the little-hierarchy problem of the minimal supersymmetric standard model. Adding a singlet Higgs superfield S can account for the observed positron excess, as recently discussed in the literature, but we point out that it requires a fine-tuned choice for the parameters of the model. We find that including an additional singlet {Psi} in a model with gauge-mediated supersymmetry breaking is a minimal extension which allows both a reduction of the weak-scale fine-tuning and an interpretation of the cosmic-ray observations in terms of dark matter annihilations in the galactic halo. Our setup contains a light axion but does not require light CP-even scalars in the spectrum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Morphology of the Galactic dark matter synchrotron emission with self-consistent cosmic-ray diffusion models

A generic prediction in the paradigm of weakly interacting dark matter is the production of relativistic particles from dark matter pair annihilation in regions of high dark matter density. Ultrarelativistic electrons and positrons produced in the center of the Galaxy by dark matter annihilation should produce a diffuse synchrotron emission. While the spectral shape of the synchrotron dark matter haze depends on the particle model (and secondarily on the Galactic magnetic fields), the morphology of the haze depends primarily on (1) the dark matter density distribution, (2) the Galactic magnetic field morphology, and (3) the diffusion model for high-energy cosmic-ray leptons. Interestingly, an unidentified excess of microwave radiation with characteristics similar to those predicted by dark matter models has been claimed to exist near the Galactic center region in the data reported by the Wilkinson Microwave Anisotropy Probe (WMAP) satellite, and is dubbed the 'WMAP haze'. In this study, we carry out a self-consistent treatment of the variables enumerated above, enforcing constraints from the available data on cosmic rays, radio surveys, and diffuse gamma rays. We outline and make predictions for the general morphology and spectral features of a 'dark matter haze' and we compare them to the WMAP haze data. We also characterize and study the spectrum and spatial distribution of the inverse-Compton emission resulting from the same population of energetic electrons and positrons. We point out that the spectrum and morphology of the radio emission at different frequencies are powerful diagnostics to test whether a Galactic synchrotron haze indeed originates from dark matter annihilation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radioactivity and electron acceleration in supernova remnants

We argue that the decays of radioactive nuclei related to {sup 44}Ti and {sup 56}Ni ejected during supernova explosions can provide a vast pool of mildly relativistic positrons and electrons which are further accelerated to ultrarelativistic energies by reverse and forward shocks. This interesting link between two independent processes - the radioactivity and the particle acceleration - can be a clue for solution of the well known theoretical problem of electron injection in supernova remnants. In the case of the brightest radio source Cas A, we demonstrate that the radioactivity can supply adequate number of energetic electrons and positrons for interpretation of observational data provided that they are stochastically preaccelerated in the upstream regions of the forward and reverse shocks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Momentum Signatures for Schwinger Pair Production in Short Laser Pulses with a Subcycle Structure

We investigate electron-positron pair production from vacuum for short laser pulses with a subcycle structure, in the nonperturbative regime (Schwinger pair production). We use the nonequilibrium quantum kinetic approach and show that the momentum spectrum of the created electron-positron pairs is extremely sensitive to the subcycle dynamics--depending on the laser frequency {omega}, the pulse length {tau}, and the carrier phase {phi}--and shows several distinctive new signatures. This observation could not only help in the design of laser pulses to optimize the experimental signature of Schwinger pair production but also ultimately lead to new probes of light pulses at extremely short time scales.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Parity-Violating Longitudinal Single-Spin Asymmetry for W{sup {+-}} Boson Production in Polarized Proton-Proton Collisions at {radical}(s)=500 GeV

We report the first measurement of the parity-violating single-spin asymmetries for midrapidity decay positrons and electrons from W{sup +} and W{sup -} boson production in longitudinally polarized proton-proton collisions at {radical}(s)=500 GeV by the STAR experiment at RHIC. The measured asymmetries, A{sub L}{sup W+}=-0.27{+-}0.10(stat.){+-}0.02(syst.){+-}0.03(norm.) and A{sub L}{sup W-}=0.14{+-}0.19(stat.){+-}0.02(syst.){+-}0.01(norm.), are consistent with theory predictions, which are large and of opposite sign. These predictions are based on polarized quark and antiquark distribution functions constrained by polarized deep-inelastic scattering measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial correlation of proton irradiation-induced activity and dose in polymer gel phantoms for PET/CT delivery verification studies

Purpose: This work demonstrates a novel application of BANG3-Pro2 polymer gel dosimeter as a dosimetric phantom able to accurately capture both dose and induced activity. Methods: BANG3-Pro2 dosimeters were irradiated with a clinical proton beam using an unmodulated beam and a spread-out Bragg peak (SOBP) modulation, the latter with a Lucite compensator to introduce a range offset in one quadrant of the circular field. The dosimeters were imaged in a nearby positron emission tomography/computed tomography (PET/CT) unit starting within 5 min of beam-off. Induced positron emission (PE) activity along the central axis of the beam was compared to analytical calculations. Dose distributions were read out using an optical CT scanner and were validated against ion chamber measurements and the treatment plan. The offset between the distal fall-off of dose and activity (50% level) was determined over the entire irradiated field. Lateral profiles of PE were correlated to measured dose for the unmodulated beam delivery. Results: Measured profiles of PE activity along the central beam axis were found to be within 10% of the predictions of analytical calculations. The depth-dose profiles agreed with the reference values (ion chamber or treatment plan) within 3%. The offset between the depth profiles of dose and activity for the unmodulated beam was 8.4 {+-} 1.4 mm. For the compensator-based SOBP delivery, the distribution of offsets throughout the field was found to be bimodal, with the mean of 8.9 {+-} 2.8 mm for the thinner region of the compensator and 4.3 {+-} 2.5 mm for the thicker region. For the pristine beam delivery, lateral profiles of dose and activity were found to exhibit fair spatial correlation throughout the beam range, with the mean 2D gamma index of 0.42 and 91% of the evaluated pixels passing the test. Conclusions: This work presents the first demonstration of simultaneous and accurate experimental measurement of three-dimensional distributions of dose and induced activity and lays the groundwork for further investigations using BANG3-Pro2 as a dosimetric phantom in PET/CT delivery verification studies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Novel multimodality segmentation using level sets and Jensen-Rényi divergence

Purpose: Positron emission tomography (PET) is playing an increasing role in radiotherapy treatment planning. However, despite progress, robust algorithms for PET and multimodal image segmentation are still lacking, especially if the algorithm were extended to image-guided and adaptive radiotherapy (IGART). This work presents a novel multimodality segmentation algorithm using the Jensen-Rényi divergence (JRD) to evolve the geometric level set contour. The algorithm offers improved noise tolerance which is particularly applicable to segmentation of regions found in PET and cone-beam computed tomography. Methods: A steepest gradient ascent optimization method is used in conjunction with the JRD and a level set active contour to iteratively evolve a contour to partition an image based on statistical divergence of the intensity histograms. The algorithm is evaluated using PET scans of pharyngolaryngeal squamous cell carcinoma with the corresponding histological reference. The multimodality extension of the algorithm is evaluated using 22 PET/CT scans of patients with lung carcinoma and a physical phantom scanned under varying image quality conditions. Results: The average concordance index (CI) of the JRD segmentation of the PET images was 0.56 with an average classification error of 65%. The segmentation of the lung carcinoma images had a maximum diameter relative error of 63%, 19.5%, and 14.8% when using CT, PET, and combined PET/CT images, respectively. The estimated maximal diameters of the gross tumor volume (GTV) showed a high correlation with the macroscopically determined maximal diameters, with aR{sup 2} value of 0.85 and 0.88 using the PET and PET/CT images, respectively. Results from the physical phantom show that the JRD is more robust to image noise compared to mutual information and region growing. Conclusions: The JRD has shown improved noise tolerance compared to mutual information for the purpose of PET image segmentation. Presented is a flexible framework for multimodal image segmentation that can incorporate a large number of inputs efficiently for IGART.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dual energy CT for attenuation correction with PET/CT

Purpose: The authors evaluate the energy dependent noise and bias properties of monoenergetic images synthesized from dual-energy CT (DECT) acquisitions. These monoenergetic images can be used to estimate attenuation coefficients at energies suitable for positron emission tomography (PET) and single-photon emission computed tomography (SPECT) imaging. This is becoming more relevant with the increased use of quantitative imaging by PET/CT and SPECT/CT scanners. There are, however, potential variations in the noise and bias of synthesized monoenergetic images as a function of energy. Methods: The authors used analytic approximations and simulations to estimate the noise and bias of synthesized monoenergetic images of water-filled cylinders with different shapes and the NURBS-based cardiac-torso (NCAT) phantom from 40 to 520 keV, the range of SPECT and PET energies. The dual-kVp spectra were based on the GE Lightspeed VCT scanner at 80 and 140 kVp with added filtration of 0.5 mm Cu. The authors evaluated strategies of noise suppression with sinogram smoothing and dose minimization with reduction of tube currents at the two kVp settings. The authors compared the impact of DECT-based attenuation correction with single-kVp CT-based attenuation correction on PET quantitation for the NCAT phantom for soft tissue and high-Z materials of bone and iodine contrast enhancement. Results: Both analytic calculations and simulations displayed the expected minimum noise value for a synthesized monoenergetic image at an energy between the mean energies of the two spectra. In addition the authors found that the normalized coefficient of variation in the synthesized attenuation map increased with energy but reached a plateau near 160 keV, and then remained constant with increasing energy up to 511 keV and beyond. The bias was minimal, as the linear attenuation coefficients of the synthesized monoenergetic images were within 2.4% of the known true values across the entire energy range. Compared with no sinogram smoothing, sinogram smoothing can dramatically reduce noise in the DECT-derived attenuation map. Through appropriate selection of tube currents for high and low kVp scans, DECT can deliver roughly the same amount of radiation dose as that of a single kVp CT scan, but could be used for PET attenuation correction with reduced bias in contrast agent regions by a factor of ∼2.6 and slightly reduced RMSE for the total image. Conclusions: When DECT is used for attenuation correction at higher energies, there is a noise amplification that is dependent on the energy of the synthesized monoenergetic image of linear attenuation coefficients. Sinogram smoothing reduces the noise amplification in DECT-derived attenuation maps without increasing bias. With an appropriate selection of CT techniques, a DECT scan with the same radiation dose as a single CT scan can result in a PET image with improved quantitative accuracy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated evaluation of setup errors in carbon ion therapy using PET: Feasibility study

Purpose: To investigate the possibility of detecting patient mispositioning in carbon-ion therapy with particle therapy positron emission tomography (PET) in an automated image registration based manner. Methods: Tumors in the head and neck (H and N), pelvic, lung, and brain region were investigated. Biologically optimized carbon ion treatment plans were created with TRiP98. From these treatment plans, the reference β{sup +}-activity distributions were calculated using a Monte Carlo simulation. Setup errors were simulated by shifting or rotating the computed tomography (CT). The expected β{sup +} activity was calculated for each plan with shifts. Finally, the reference particle therapy PET images were compared to the “shifted” β{sup +}-activity distribution simulations using the Pearson's correlation coefficient (PCC). To account for different PET monitoring options the inbeam PET was compared to three different inroom scenarios. Additionally, the dosimetric effects of the CT misalignments were investigated. Results: The automated PCC detection of patient mispositioning was possible in the investigated indications for cranio-caudal shifts of 4 mm and more, except for prostate tumors. In the rather homogeneous pelvic region, the generated β{sup +}-activity distribution of the reference and compared PET image were too much alike. Thus, setup errors in this region could not be detected. Regarding lung lesions the detection strongly depended on the exact tumor location: in the center of the lung tumor misalignments could be detected down to 2 mm shifts while resolving shifts of tumors close to the thoracic wall was more challenging. Rotational shifts in the H and N and lung region of +6° and more could be detected using inroom PET and partly using inbeam PET. Comparing inroom PET to inbeam PET no obvious trend was found. However, among the inroom scenarios a longer measurement time was found to be advantageous. Conclusions: This study scopes the use of various particle therapy PET verification techniques in four indications. The automated detection of patients' setup errors was investigated in a broad accumulation of data sets. The evaluation of introduced setup errors is performed automatically, which is of utmost importance to introduce highly required particle therapy monitoring devices into the clinical routine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validating and improving CT ventilation imaging by correlating with ventilation 4D-PET/CT using {sup 68}Ga-labeled nanoparticles

Purpose: CT ventilation imaging is a novel functional lung imaging modality based on deformable image registration. The authors present the first validation study of CT ventilation using positron emission tomography with{sup 68}Ga-labeled nanoparticles (PET-Galligas). The authors quantify this agreement for different CT ventilation metrics and PET reconstruction parameters. Methods: PET-Galligas ventilation scans were acquired for 12 lung cancer patients using a four-dimensional (4D) PET/CT scanner. CT ventilation images were then produced by applying B-spline deformable image registration between the respiratory correlated phases of the 4D-CT. The authors test four ventilation metrics, two existing and two modified. The two existing metrics model mechanical ventilation (alveolar air-flow) based on Hounsfield unit (HU) change (V{sub HU}) or Jacobian determinant of deformation (V{sub Jac}). The two modified metrics incorporate a voxel-wise tissue-density scaling (ρV{sub HU} and ρV{sub Jac}) and were hypothesized to better model the physiological ventilation. In order to assess the impact of PET image quality, comparisons were performed using both standard and respiratory-gated PET images with the former exhibiting better signal. Different median filtering kernels (σ{sub m} = 0 or 3 mm) were also applied to all images. As in previous studies, similarity metrics included the Spearman correlation coefficient r within the segmented lung volumes, and Dice coefficient d{sub 20} for the (0 − 20)th functional percentile volumes. Results: The best agreement between CT and PET ventilation was obtained comparing standard PET images to the density-scaled HU metric (ρV{sub HU}) with σ{sub m} = 3 mm. This leads to correlation values in the ranges 0.22 ⩽ r ⩽ 0.76 and 0.38 ⩽ d{sub 20} ⩽ 0.68, with r{sup ¯}=0.42±0.16 and d{sup ¯}{sub 20}=0.52±0.09 averaged over the 12 patients. Compared to Jacobian-based metrics, HU-based metrics lead to statistically significant improvements in r{sup ¯} and d{sup ¯}{sub 20} (p < 0.05), with density scaled metrics also showing higher r{sup ¯} than for unscaled versions (p < 0.02). r{sup ¯} and d{sup ¯}{sub 20} were also sensitive to image quality, with statistically significant improvements using standard (as opposed to gated) PET images and with application of median filtering. Conclusions: The use of modified CT ventilation metrics, in conjunction with PET-Galligas and careful application of image filtering has resulted in improved correlation compared to earlier studies using nuclear medicine ventilation. However, CT ventilation and PET-Galligas do not always provide the same functional information. The authors have demonstrated that the agreement can improve for CT ventilation metrics incorporating a tissue density scaling, and also with increasing PET image quality. CT ventilation imaging has clear potential for imaging regional air volume change in the lung, and further development is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of advanced automatic PET segmentation methods using nonspherical thin-wall inserts

Purpose: The use of positron emission tomography (PET) within radiotherapy treatment planning requires the availability of reliable and accurate segmentation tools. PET automatic segmentation (PET-AS) methods have been recommended for the delineation of tumors, but there is still a lack of thorough validation and cross-comparison of such methods using clinically relevant data. In particular, studies validating PET segmentation tools mainly use phantoms with thick plastic walls inserts of simple spherical geometry and have not specifically investigated the effect of the target object geometry on the delineation accuracy. Our work therefore aimed at generating clinically realistic data using nonspherical thin-wall plastic inserts, for the evaluation and comparison of a set of eight promising PET-AS approaches. Methods: Sixteen nonspherical inserts were manufactured with a plastic wall of 0.18 mm and scanned within a custom plastic phantom. These included ellipsoids and toroids derived with different volumes, as well as tubes, pear- and drop-shaped inserts with different aspect ratios. A set of six spheres of volumes ranging from 0.5 to 102 ml was used for a baseline study. A selection of eight PET-AS methods, written in house, was applied to the images obtained. The methods represented promising segmentation approaches such as adaptive iterative thresholding, region-growing, clustering and gradient-based schemes. The delineation accuracy was measured in terms of overlap with the computed tomography reference contour, using the dice similarity coefficient (DSC), and error in dimensions. Results: The delineation accuracy was lower for nonspherical inserts than for spheres of the same volume in 88% cases. Slice-by-slice gradient-based methods, showed particularly lower DSC for tori (DSC < 0.5), caused by a failure to recover the object geometry. The region-growing method reached high levels of accuracy for most inserts (DSC > 0.76 except for tori) but showed the largest errors in the recovery of pears and drops dimensions (higher than 10% and 30% of the true length, respectively). Large errors were visible for one of the gradient-based contouring methods when delineating drop-shaped inserts. Low DSC due to systematic underestimation of the volumes was observed for our fuzzy clustering method when using nonspherical inserts. The adaptive iterative thresholding method produced the highest DSC score on our nonspherical dataset (DSC > 0.83, except for tori) and showed robustness to the insert geometry. Conclusions: This study investigated the accuracy of eight PET-AS methods for the delineation of objects with a range of nonspherical geometries. The authors’ results confirmed the robustness of some segmentation approaches, but also showed the weaknesses of some of the other methods implemented, which were not observed with spherical inserts. This work therefore highlights the importance of using a variety of thin-wall inserts with complex geometries for the validation of PET-AS methods and provided useful information for further development of the methods tested.

62 RADIOLOGY AND NUCLEAR MEDICINE↗