Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PHASE DETECTOR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Design of a Cryogenic Assembly for Comparing Qubit Infrared Packaging Inefficiencies

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Mailliard, Robert J. [Fermilab] (ORCID:00090000277↗

CMS Outer Tracker Module QA

It is well known that everything emits infrared (IR) light in the form of thermal radiation. IR radiation on superconducting qubits carries enough energy to cause decoherence and so-called “quasiparticle poisoning.” Therefore, proper IR shielding is needed to keep the qubit in a high-coherence state. However, trying to extract IR-specific information from a qubit is difficult, so a microwave kinetic inductance detector (MKID) can be used instead. We show that the IR shielding inefficiencies of MKID packages can only be compared with other packaging inefficiencies. We create a cryogenic assembly CAD design, consisting of magnetic shield cans, a copper mounting plate and mounts, and an MKID enclosure, which thermalizes the assembly to dilution refrigerator temperatures. Phase 1 of this design involves using a narrowband IR laser source to test the IR shielding of packaging at the laser’s wavelength. When the best IR shielding packaging is determined, the superconducting qubit can replace the MKID, allowing the qubit to avoid decoherence due to IR radiation and boost its performance and coherence lifetime.

Hobbeheydar, Samuel [Carnegie Mellon U. (main); Fe↗

CP Violation Measurements at the Tevatron

The two colliding beam experiments at the Tevatron proton-antiproton collider, CDF and D0, continue to publish world-leading measurements of CP Violation parameters in the B meson sector. I will present several recent results from both experiments, including measurements of direct CP violating parameters in decays of B{sup +}{sub u}, B{sup 0}{sub d} and B{sup 0}{sub s} mesons; a new D0 measurement of a{sup s}{sub sl} using time-dependent analysis of B{sub s} {yields} {mu}{sup +}{nu}D{sup -}{sub s}X decays; and the latest Tevatron combination of the CP violating phase {beta}{sub s}, measured in the 'golden mode' B{sub s} {yields} J/{psi}{phi}.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Formation of Double Neutron Star Systems

Double neutron star (DNS) systems represent extreme physical objects and the endpoint of an exotic journey of stellar evolution and binary interactions. Large numbers of DNS systems and their mergers are anticipated to be discovered using the Square Kilometre Array searching for radio pulsars, and the high-frequency gravitational wave detectors (LIGO/VIRGO), respectively. Here we discuss all key properties of DNS systems, as well as selection effects, and combine the latest observational data with new theoretical progress on various physical processes with the aim of advancing our knowledge on their formation. We examine key interactions of their progenitor systems and evaluate their accretion history during the high-mass X-ray binary stage, the common envelope phase, and the subsequent Case BB mass transfer, and argue that the first-formed NSs have accreted at most ∼0.02 M{sub ⊙}. We investigate DNS masses, spins, and velocities, and in particular correlations between spin period, orbital period, and eccentricity. Numerous Monte Carlo simulations of the second supernova (SN) events are performed to extrapolate pre-SN stellar properties and probe the explosions. All known close-orbit DNS systems are consistent with ultra-stripped exploding stars. Although their resulting NS kicks are often small, we demonstrate a large spread in kick magnitudes that may, in general, depend on the past interaction history of the exploding star and thus correlate with the NS mass. We analyze and discuss NS kick directions based on our SN simulations. Finally, we discuss the terminal evolution of close-orbit DNS systems until they merge and possibly produce a short γ-ray burst.

79 ASTRONOMY AND ASTROPHYSICS↗

Measurement of the ZZ production cross section in proton-proton collisions at $ \sqrt{s}=8 $ TeV using the ZZ → ℓ – ℓ + ℓ'ℓ' + and $ZZ\to {\ell}^{-}{\ell}^{+}\nu \overline{\nu} $ decay channels with the ATLAS detector

A measurement of the ZZ production cross section in the ℓ – ℓ + ℓ' – ℓ' + and ℓ – ℓ + νν¯channels (ℓ = e, μ) in proton-proton collisions at √s = 8TeV at the Large Hadron Collider at CERN, using data corresponding to an integrated luminosity of 20.3 fb –1 collected by the ATLAS experiment in 2012 is presented. The fiducial cross sections for ZZ → ℓ – ℓ + ℓ' – ℓ' + and ZZ → ℓ – ℓ + νν¯ are measured in selected phase-space regions. The total cross section for ZZ events produced with both Z bosons in the mass range 66 to 116 GeV is measured from the combination of the two channels to be 7.3±0.4(stat)±0.3(syst) –0.1 –0.2 (lumi)pb, which is consistent with the Standard Model prediction of 6.6 –0.6 +0.7 pb. The differential cross sections in bins of various kinematic variables are presented. The differential event yield as a function of the transverse momentum of the leading Z boson is used to set limits on anomalous neutral triple gauge boson couplings in ZZ production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Research and Development Toward Massive Liquid Argon Time Projection Chambers for Neutrino Detection

Liquid argon (LAr) time projection chambers (TPC) have rapidly increased in importance as particle detectors throughout the past four decades. While much research has been completed, there are still many areas which require further development to build and operate the next generation LAr TPC experiment, such as the Deep Underground Neutrino Experiment (DUNE). These include high voltage breakdown, argon purification and purity monitoring, and vacuum ultraviolet (VUV) scintillation light measurement. Visual monitoring of high voltage breakdown is helpful in allowing assessment of the performance of high voltage component design. Thus, a system of cryogenic cameras, the first of its kind, was developed for use in a large LAr cryostat, without the need for additional electronics heating. The system functioned without problem for 50 days at cryogenic temperature, with some degradation of image quality, and provided a useful monitor for the DUNE 35-ton cryogenics systems. The system did not observe any high voltage breakdowns during the run. Further development of the concept is ongoing for future installation in other experiments. The monitoring of LAr purity using TPC data is a fundamental study for LAr TPC experiments. However, the study has not been performed for a large LAr TPC in the presence of high electronic noise. Custom software was developed and validated for the accurate reconstruction of signals in noisy TPC data. The results of the reconstruction were used to successfully measure the LAr electron lifetime with an uncertainty comparable to alternate methods of measurement. The electron lifetime of the 35-ton Phase II run is determined to be 4.12 ± 0.17 (stat.) ±0.40 (syst.) ms. For general purpose research and development of high purity LAr as a particle detection medium, a dedicated test stand was designed, constructed, and commissioned. The system is used to test the gaseous photomultiplier (GPM) performance at cryogenic temperatures. The GPM functions with photoelectron multiplication at 77 K, at a reduced gain. Further study is required to show the detector’s direct sensitivity to LAr VUV scintillation light.

Thiesse, Matthew↗

Measurement of the semileptonic $ \mathrm{t}\overline{\mathrm{t}} $ + γ production cross section in pp collisions at $ \sqrt{s}=8 $ TeV

A measurement of the cross section for top quark-antiquark ( $ \mathrm{t}\overline{\mathrm{t}} $ ) pairs produced in association with a photon in proton-proton collisions at $ \sqrt{s}=8 $ TeV is presented. The analysis uses data collected with the CMS detector at the LHC, corresponding to an integrated luminosity of 19.7 fb$^{1}$. The signal is defined as the production of a $ \mathrm{t}\overline{\mathrm{t}} $ pair in association with a photon having a transverse energy larger than 25 GeV and an absolute pseudorapidity smaller than 1.44. The measurement is performed in the fiducial phase space corresponding to the semileptonic decay chain of the $ \mathrm{t}\overline{\mathrm{t}} $ pair, and the cross section is measured relative to the inclusive $ \mathrm{t}\overline{\mathrm{t}} $ pair production cross section. The fiducial cross section for associated $ \mathrm{t}\overline{\mathrm{t}} $ pair and photon production is found to be 127 ±27 (stat+syst) fb per semileptonic final state. The measured value is in agreement with the theoretical prediction.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Combined computed tomography and position-resolved X-ray diffraction of an intact Roman-era Egyptian portrait mummy

Hawara Portrait Mummy 4, a Roman-era Egyptian portrait mummy, was studied with computed tomography (CT) and with CT-guided synchrotron X-ray diffraction mapping. These are the first X-ray diffraction results obtained non-invasively from objects within a mummy. The CT data showed human remains of a 5-year-old child, consistent with the female (but not the age) depicted on the portrait. Physical trauma was not evident in the skeleton. Diffraction at two different mummy-to-detector separations allowed volumetric mapping of features including wires and inclusions within the wrappings and the skull and femora. Additionally, the largest uncertainty in origin determination was approximately 1.5 mm along the X-ray beam direction, and diffraction- and CT-determined positions matched. Diffraction showed that the wires were a modern dual-phase steel and showed that the 7 × 5 × 3 mm inclusion ventral of the abdomen was calcite. Tracing the 00.2 and 00.4 carbonated apatite (bone's crystalline phase) reflections back to their origins produced cross-sectional maps of the skull and of femora; these maps agreed with transverse CT slices within approximately 1 mm. Coupling CT and position-resolved X-ray diffraction, therefore, offers considerable promise for non-invasive studies of mummies.

60 APPLIED LIFE SCIENCES↗

Pion, kaon, and (anti)proton production in $\cup + \cup$ collisions at $\sqrt{s_{NN}} = 193$ GeV measured with the STAR detector

We present the first measurements of transverse momentum spectra of $π^±, K^±, p(\overline{p})$ at midrapidity ($|y|$ < 0.1) in $\cup + \cup$ collisions at $\sqrt{s_{NN}} = 193$ GeV with the STAR detector at the Relativistic Heavy Ion Collider (RHIC). The centrality dependence of particle yields, average transverse momenta, particle ratios and kinetic freezeout parameters are discussed. The results are compared with the published results from Au+Au collisions at $\sqrt{s_{NN}} = 200$ GeV in STAR. The results are also compared to those from A Multi Phase Transport (AMPT) model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NOvA Recent Results of Three-Flavor Oscillation Analysis

The NOvA experiment is a long-baseline neutrino experiment designed to study the oscillation behavior of neutrinos and antineutrinos, utilizing Fermilab’s Megawatt-capable NuMI neutrino beam. Over the past 10 years, NOvA has collected data from two functionally identical tracking calorimeter detectors, which are situated off the NuMI beam axis and separated by 810 km. The construction of the experiment enables observation of muon (anti)neutrino disappearance and electron (anti)neutrino appearance. Consequently, precision measurements of oscillation parameters, including the mass splitting $\Delta m_{32}^{2}$ and its sign, the mixing angle $\theta_{23}$, and the phase of $CP$-symmetry violation, can be obtained. This paper presents an overview of the NOvA experiment and its latest results.

Kalitkina, Anastasiia [Dubna, JINR]↗

Measuring the Multi-Neutron Antineutrino Cross Section at Low Charged Hadron Energy in MINERvA

Current and future accelerator neutrino oscillation experiments need neutrino interaction models with smaller systematic uncertainties to resolve much of delta CP phase space. Final state interactions (FSI) and scattering off of correlated nuclei (2p2h) are poorly understood processes that currently contribute large uncertainties to leading models. These processes have proven difficult to study because they often produce relatively low energy nucleons. Protons up to about 100 MeV are below the detection threshold of some accelerator neutrino detectors, and neutrons are usually discounted as undetectable. This poster presents a measurement of the multi-neutron antineutrino cross section at low available energy using the MINERvA detector at Fermilab. This interaction channel is particularly sensitive to FSI and 2p2h interactions. A sideband-driven background constraint that greatly reduces uncertainties on the result will be presented. The measured cross section is compared to GENIE v3 models with different FSI treatments and the SuSA model's 2p2h predictions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Radiation-Hard Smart-Pixel Detector ASIC ReadOut with Digital AI in 28nm

Detectors at future high energy colliders will face enormous technical challenges. Disentangling the unprecedented numbers of particles expected in each event will require highly granular silicon pixel detectors with billions of readout channels. With event rates as high as 40 MHz, these detectors will generate petabytes of data per second. To enable discovery within strict bandwidth and latency constraints, future trackers must be capable of fast, power efficient, and radiation hard data-reduction at the source. This effort is pursuing the co-design development of high-performance readout smart pixel ASICs for a future Phase III High Luminosity upgrade of the Large Hadron Collider. A 1.6mm2 ASIC prototype was designed by Fermilab in CMOS 28 nm bulk process and submitted for manufacturing in February 2024. It leverages the analog front-end pixel design of a previous prototype fabricated and tested in 2023, which achieved a simulated detection level of ~400e- with 30fF input capacitance. The ROIC consists of two matrices of 16×16 smart pixels, each 25×25 μm2 in size. Each smart pixel contains a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. There is digital space for the integration of our fully combinatorial AI that performs momentum classification at the bunch crossing rate. The total power consumption is ∼6μW per pixel, which corresponds to ~1mW/cm2. The ASIC incorporates programmable front-end charge injection circuitry to generate pixel cluster charges during characterization. The cluster profile will be generated to duplicate hit characteristics of various momentum (pT). We will present early results from chip testing.

Parpillon, Benjamin↗

Measurement of the CP-violating phase phi sJ/psi phi using the flavor-tagged decay Bs(0) -> J/psi phi in 8 fb(-1) of p(p)over-bar collisions

We report an updated measurement of the CP-violating phase, {phi}{sub s}{sup J/{psi}{phi}} and the decay-width difference for the two mass eigenstates, {Delta}{Gamma}{sub s}, from the flavor-tagged decay B{sub s}{sup 0} {yields} J/{psi}{phi}. The data sample corresponds to an integrated luminosity of 8.0 fb{sup -1} accumulated with the D0 detector using p{bar p} collisions at {radical}s = 1.96 TeV produced at the Fermilab Tevatron collider. The 68% Bayesian credibility intervals, including systematic uncertainties, are {Delta}{Gamma}{sub s} = 0.163{sub -0.064}{sup +0.065} ps{sup -1} and {phi}{sub s}{sup J}/{psi}{phi} = -0.55{sub -0.36}{sup +0.38}. The p-value for the Standard Model point is 29.8%.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Study of Bbar to Xu l nubar Decays in BBbar Events Tagged by a Fully Reconstructed B-meson Decay and Determination of |V_{ub}|

We report measurements of partial branching fractions for inclusive charmless semileptonic B decays {bar B} {yields} X{sub u}{ell}{bar {nu}}, and the determination of the CKM matrix element |V{sub ub}|. The analysis is based on a sample of 467 million {Upsilon}(4S) {yields} B{bar B} decays recorded with the BABAR detector at the PEP-II e{sup +}e{sup -} storage rings. We select events in which the decay of one of the B mesons is fully reconstructed and an electron or a muon signals the semileptonic decay of the other B meson. We measure partial branching fractions {Delta}{Beta} in several restricted regions of phase space and determine the CKM element |V{sub ub}| based on four different QCD predictions. For decays with a charged lepton momentum p*{sub {ell}} > 1.0 GeV in the B meson rest frame, we obtain {Delta}{Beta} = (1.80 {+-} 0.13{sub stat.} {+-} 0.15{sub sys.} {+-} 0.02{sub theo.}) x 10{sup -3} from a maximum likelihood fit to the two-dimensional M{sub X} - q{sup 2} distribution. Here, M{sub X} refers to the invariant mass of the final state hadron X and q{sup 2} is the invariant mass squared of the charged lepton and neutrino. From this measurement we extract |V{sub ub}| = (4.31 {+-} 0.25{sub exp.} {+-} 0.16{sub theo.}) x 10{sup -3} as the arithmetic average of four results obtained from four different QCD predictions of the partial rate. We separately determine partial branching fractions for {bar B}{sup 0} and B{sup -} decays and derive a limit on the isospin breaking in {bar B} {yields} X{sub u}{ell}{bar {nu}} decays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Monte Carlo simulation framework for electron beam dose calculations using Varian phase space files for TrueBeam Linacs

Purpose: To develop a framework for accurate electron Monte Carlo dose calculation. In this study, comprehensive validations of vendor provided electron beam phase space files for Varian TrueBeam Linacs against measurement data are presented. Methods: In this framework, the Monte Carlo generated phase space files were provided by the vendor and used as input to the downstream plan-specific simulations including jaws, electron applicators, and water phantom computed in the EGSnrc environment. The phase space files were generated based on open field commissioning data. A subset of electron energies of 6, 9, 12, 16, and 20 MeV and open and collimated field sizes 3 × 3, 4 × 4, 5 × 5, 6 × 6, 10 × 10, 15 × 15, 20 × 20, and 25 × 25 cm{sup 2} were evaluated. Measurements acquired with a CC13 cylindrical ionization chamber and electron diode detector and simulations from this framework were compared for a water phantom geometry. The evaluation metrics include percent depth dose, orthogonal and diagonal profiles at depths R{sub 100}, R{sub 50}, R{sub p}, and R{sub p+} for standard and extended source-to-surface distances (SSD), as well as cone and cut-out output factors. Results: Agreement for the percent depth dose and orthogonal profiles between measurement and Monte Carlo was generally within 2% or 1 mm. The largest discrepancies were observed within depths of 5 mm from phantom surface. Differences in field size, penumbra, and flatness for the orthogonal profiles at depths R{sub 100}, R{sub 50}, and R{sub p} were within 1 mm, 1 mm, and 2%, respectively. Orthogonal profiles at SSDs of 100 and 120 cm showed the same level of agreement. Cone and cut-out output factors agreed well with maximum differences within 2.5% for 6 MeV and 1% for all other energies. Cone output factors at extended SSDs of 105, 110, 115, and 120 cm exhibited similar levels of agreement. Conclusions: We have presented a Monte Carlo simulation framework for electron beam dose calculations for Varian TrueBeam Linacs. Electron beam energies of 6 to 20 MeV for open and collimated field sizes from 3 × 3 to 25 × 25 cm{sup 2} were studied and results were compared to the measurement data with excellent agreement. Application of this framework can thus be used as the platform for treatment planning of dynamic electron arc radiotherapy and other advanced dynamic techniques with electron beams.

60 APPLIED LIFE SCIENCES↗

The Phase-1 Upgrade of the ATLAS Level-1 Endcap Muon Trigger. In: Proceedings of International Conference on Technology and Instrumentation in Particle Physics 2017

The Level-1 muon trigger for the ATLAS experiment identifies muons with high transverse momentum. Under the high luminosity condition in LHC Run 3, more powerful trigger system is needed to reject the backgrounds. New trigger processor board for Run 3 has been produced to achieve the required performance, by combining information from five different detectors. The performance of the new board and the readout system has been confirmed by a beam test. The new algorithms to make use of the new detectors have been developed, and are tested by MC simulation. With the new algorithms, the trigger rate is estimated to become lower than the required rate in Run 3.

Akatsuka, Shunichi↗

Low Cost Open-Path Instrument for Monitoring Atmospheric Carbon Dioxide at Sequestration Sites

In the past 48 months of the project, we have accomplished all objectives outlined in the proposal. In the first year, we demonstrated the technology for remote sensing on a bench top scale. The core electronics are designed and fabricated. We achieved results that will safely deliver the specifications outlined in the proposal. In the 2nd year, 2 major technical tasks outlined in the Statement of Objectives, i.e. Build a field test ready prototype of a long-range CO2 monitor, and characterize its performance in the short term and demonstrate that the monitor characteristics meet the goals set in the initial proposal, have been accomplished. We also conducted simulation work that defines the different deployment strategies for our sensors at sequestration sites. In the 3rd year, Specifications and Testing protocols have been developed for the CO2 monitor. 1% accuracy had been demonstrated in short period tests ({approx}1 hour). Unattended system operation and stability over a period of a week has been demonstrated with and without EDFA (laser power amplifier). The sensitivity of the instrument to CO2 leaks has been demonstrated. In the 4th no-cost extension year, we further field tested the system and the experience we accumulated give us a clear picture of what else are needed for final field deployment. These results have shown all the objectives of the project have been fulfilled. In July 2008, along with our commercial partner we won the DOE STTR phase I award to commercialize the instrument developed in this project - a testimony to the achievement of this research.

47 OTHER INSTRUMENTATION↗

Inclusive and differential cross section measurements of $ \textrm{t}\overline{\textrm{t}}\textrm{b}\overline{\textrm{b}} $ production in the lepton+jets channel at $ \sqrt{s} $ = 13 TeV

Measurements of inclusive and normalized differential cross sections of the associated production of top quark-antiquark and bottom quark-antiquark pairs, $ \textrm{t}\overline{\textrm{t}}\textrm{b}\overline{\textrm{b}} $, are presented. The results are based on data from proton-proton collisions collected by the CMS detector at a centre-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 138 fb$^{−1}$. The cross sections are measured in the lepton+jets decay channel of the top quark pair, using events containing exactly one isolated electron or muon and at least five jets. Measurements are made in four fiducial phase space regions, targeting different aspects of the $ \textrm{t}\overline{\textrm{t}}\textrm{b}\overline{\textrm{b}} $ process. Distributions are unfolded to the particle level through maximum likelihood fits, and compared with predictions from several event generators. The inclusive cross section measurements of this process in the fiducial phase space regions are the most precise to date. In most cases, the measured inclusive cross sections exceed the predictions with the chosen generator settings. The only exception is when using a particular choice of dynamic renormalization scale, $ {\mu}_{\textrm{R}}=\frac{1}{2}{\prod}_{i=\textrm{t},\overline{\textrm{t}},\textrm{b},\overline{\textrm{b}}}{m}_{\textrm{T},i}^{1/4} $, where $ {m}_{\textrm{T},i}^2={m}_i^2+{p}_{\textrm{T},i}^2 $ are the transverse masses of top and bottom quarks. The differential cross sections show varying degrees of compatibility with the theoretical predictions, and none of the tested generators with the chosen settings simultaneously describe all the measured distributions.[graphic not available: see fulltext]

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗