Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The Development of a DC Breakdown Voltage Test for Photovoltaic Insulating Materials

The ability of electrical insulating materials within a module to act as insulators is a key safety requirement for PV technology. Direct current breakdown voltage is therefore now specified for relied-upon insulator materials in the IEC 61730-1 safety standard. To fulfill that requirement, a new test method has been developed within the IEC TS 62788-2 backsheet standard for the measurement of breakdown voltage. The development of the test will be described, including the verification of the most critical parameters relative to factors such as defect population(s), dielectric medium, electrode size, electrode surface roughness, maximum current limit, moisture conditioning, number of replicate specimens, rate of voltage rise, specimen thickness, test polarity, and test temperature. Many of these parameters were specifically explored in discovery experiments as the test method was developed. An interlaboratory round-robin (R-R) experiment was conducted to further validate the test method by quantifying its repeatability and reproducibility. The materials examined in the R-R include the backsheet materials: polyethylene terephthalate (PET, two thicknesses), polyvinyl fluoride (PVF), and laminated PVF/PET/PVF ('TPT') as well as the encapsulants poly(ethylene-co-vinyl acetate) (EVA), and polyvinyl butyral (PVB). The precision of the test method as well as key factors contributing to the measurement will be described.

14 SOLAR ENERGY↗

Characterization of Real-World and Accelerated Exposed PV Module Backsheet Degradation

Backsheet degradation is key to maintaining the lifetime of photovoltaic (PV) modules. Cracking, delamination, bubbling, and discoloration are main types of degradation. PV modules were collected from PV installations in multiple climatic zones. Multiple types of backsheets were obtained with poly(ethylene teraphlate) (PET) and polyamide air side layers being the largest number of backsheets retrieved. Multiple commercial PV backsheets were exposed to multiple accelerated exposures and key degradation mechanisms were identified. Polyamide backsheets showed cracking in retrieved modules and under accelerated exposures. Poly(vinylidene fluoride) (PVDF) and poly(vinyl fluoride) (PVF) showed the highest stability in retrieved and accelerated exposures. While polyamide had the largest amount of large scale degradation.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Performance Evaluation of a Bedside Cardiac SPECT System

This paper reports on the initial performance evaluation of a bedside cardiac PET/SPECT system. The system was designed to move within a hospital to image critically-ill patients, for example, those in intensive care unit (ICU) or emergency room settings, who cannot easily be transported to a conventional SPECT or PET facility. The system uses two compact (25 cm times 25 cm) detectors with pixilated NaI crystals and position sensitive PMTs. The performance is evaluated for both 140 keV (Tc-99m) and 511 keV (F-18) emitters with the system operating in single photon counting (SPECT) mode. The imaging performance metrics for both 140 keV and 511 keV included intrinsic energy resolution, spatial resolution (intrinsic, system, and reconstructed SPECT), detection sensitivity, count rate capability, and uniformity. Results demonstrated an intrinsic energy resolution of 31% at 140 keV and 23% at 511 keV, a planar intrinsic spatial resolution of 5.6 mm full width half-maximum (FWHM) at 140 keV and 6.3 mm FWHM at 511 keV, and a sensitivity of 4.15 countsmiddotmuCi-1 ldr s-1 at 140 keV and 0.67 counts ldr muCi-1 ldr s-1 at 511 keV. To further the study, a SPECT acquisition using a dynamic cardiac phantom was performed, and the resulting reconstructed images are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microdosing and Other Phase 0 Clinical Trials: Facilitating Translation in Drug Development

A number of drivers and developments suggest that microdosing and other phase 0 applications will experience increased utilization in the near-to-medium future. Increasing costs of drug development and ethical concerns about the risks of exposing humans and animals to novel chemical entities are important drivers in favor of these approaches, and can be expected only to increase in their relevance. An increasing body of research supports the validity of extrapolation from the limited drug exposure of phase 0 approaches to the full, therapeutic exposure, with modeling and simulations capable of extrapolating even non-linear scenarios. An increasing number of applications and design options demonstrate the versatility and flexibility these approaches offer to drug developers including the study of PK, bioavailability, DDI, and mechanistic PD effects. PET microdosing allows study of target localization, PK and receptor binding and occupancy, while Intra-Target Microdosing (ITM) allows study of local therapeutic-level acute PD coupled with systemic microdose-level exposure. Applications in vulnerable populations and extreme environments are attractive due to the unique risks of pharmacotherapy and increasing unmet healthcare needs. Lastly, all phase 0 approaches depend on the validity of extrapolation from the limited-exposure scenario to the full exposure of therapeutic intent, but in the final analysis the potential for controlled human data to reduce uncertainty about drug properties is bound to be a valuable addition to the drug development process.

60 APPLIED LIFE SCIENCES↗

A Monte-Carlo Method for Evaluating the Economic Performance of Plastics Recycling Systems Using Historical Pricing

The management of plastic waste is a considerable emerging global concern. Conventional plastics recycling rates range from 5–10% in the US, which results in considerable material being sent to landfill. New sorting technologies using artificial intelligence have the potential to dramatically increase the ability of waste management companies to sort out valuable fractions of plastic waste and create high-purity streams for secondary markets. However, several fractions of the plastics recycling stream, i.e., low-density polyethylene, polypropylene, and polystyrene, do not have well-developed markets. These materials may be sent to pyrolysis facilities for thermal recycling, but the economics of the pyrolysis industry are currently uncertain. This work aims to identify the breakeven price of the plastic fractions that would be sent to pyrolysis in order to determine the economic viability of the sorting facility. The work will use Monte Carlo analysis to evaluate several scenarios and understand how compositional variation, price variability, and facility attributes affect the breakeven price. Here, the presorting conditions in Materials Recovery Facilities strongly affects the profitability of the sorting facility. High residual high density polyethylene (HDPE) and polyethylene terephthalate (PET) content in presorted bales are important revenue drivers for the facility, even in presorted 3-7 bales. Key variables that lead to profitability include a high sale price of polyethylene terephthalate, a high sale price of high-density polyethylene, and if polypropylene can be sold to recycling markets (as opposed to pyrolysis facilities).

Plastics↗

Ag films grown by remote plasma enhanced atomic layer deposition on different substrates

Silver (Ag) layers were deposited by remote plasma enhanced atomic layer deposition (PALD) using Ag(fod)(PEt{sub 3}) (fod = 2,2-dimethyl-6,6,7,7,8,8,8-heptafluorooctane-3,5-dionato) as precursor and hydrogen plasma on silicon substrate covered with thin films of SiO{sub 2}, TiN, Ti/TiN, Co, Ni, and W at different deposition temperatures from 70 to 200 °C. The deposited silver films were analyzed by x-ray photoelectron spectroscopy (XPS), atomic force microscopy (AFM), scanning electron microscopy (SEM), transmission electron microscopy (TEM) with energy dispersive x-ray spectroscopy, four point probe measurement, ellipsometric measurement, x-ray fluorescence (XRF), and x-ray diffraction (XRD). XPS revealed pure Ag with carbon and oxygen contamination close to the detection limit after 30 s argon sputtering for depositions made at 120 and 200 °C substrate temperatures. However, an oxygen contamination was detected in the Ag film deposited at 70 °C after 12 s argon sputtering. A resistivity of 5.7 × 10{sup −6} Ω cm was obtained for approximately 97 nm Ag film on SiO{sub 2}/Si substrate. The thickness was determined from the SEM cross section on the SiO{sub 2}/Si substrate and also compared with XRF measurements. Polycrystalline cubic Ag reflections were identified from XRD for PALD Ag films deposited at 120 and 200 °C. Compared to W surface, where poor adhesion of the films was found, Co, Ni, TiN, Ti/TiN and SiO{sub 2} surfaces had better adhesion for silver films as revealed by SEM, TEM, and AFM images.

36 MATERIALS SCIENCE↗

Examination of a Junction-Box Adhesion Test for Use in Photovoltaic Module Qualification: Preprint

Engineering robust adhesion of the junction-box (j-box) is a hurdle typically encountered by photovoltaic (PV) module manufacturers during product development. There are historical incidences of adverse effects (e.g., fires) caused when the j-box/adhesive/module system has failed in the field. The addition of a weight to the j-box during the 'damp heat' IEC qualification test is proposed toverify the basic robustness of its adhesion system. The details of the proposed test will be described, in addition to the preliminary results obtained using representative materials and components. The described discovery experiments examine moisture-cured silicone, foam tape, and hot-melt adhesives used in conjunction with PET or glass module 'substrates.' To be able to interpret the results,a set of material-level characterizations was performed, including thermogravimetric analysis, differential scanning calorimetry, and dynamic mechanical analysis. PV j-boxes were adhered to a substrate, loaded with a prescribed weight, and then placed inside an environmental chamber (at 85C, 85% relative humidity). Some systems did not remain attached through the discovery experiments. Observedfailure modes include delamination (at the j-box/adhesive or adhesive/substrate interface) and phase change/creep. The results are discussed in the context of the application requirements, in addition to the plan for the formal experiment supporting the proposed modification to the qualification test.

14 SOLAR ENERGY↗

Improved MAGIC gel for higher sensitivity and elemental tissue equivalent 3D dosimetry

Purpose: Polymer-based gel dosimeter (MAGIC type) is a preferable phantom material for PET range verification of proton beam therapy. However, improvement in elemental tissue equivalency (specifically O/C ratio) is very desirable to ensure realistic time-activity measurements. Methods: Glucose and urea was added to the original MAGIC formulation to adjust the O/C ratio. The dose responses of the new formulations were tested with MRI transverse relaxation rate (R2) measurements. Results: The new ingredients improved not only the elemental composition but also the sensitivity of the MAGIC gel. The O/C ratios of our new gels agree with that of soft tissue within 1%. The slopes of dose response curves were 1.6-2.7 times larger with glucose. The melting point also increased by 5 deg. C. Further addition of urea resulted in a similar slope but with an increased intercept and a decreased melting point. Conclusions: Our improved MAGIC gel formulations have higher sensitivity and better elemental tissue equivalency for 3D dosimetry applications involving nuclear reactions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Bayesian network and support vector machine models for two-year survival prediction in lung cancer patients treated with radiotherapy

Purpose: Classic statistical and machine learning models such as support vector machines (SVMs) can be used to predict cancer outcome, but often only perform well if all the input variables are known, which is unlikely in the medical domain. Bayesian network (BN) models have a natural ability to reason under uncertainty and might handle missing data better. In this study, the authors hypothesize that a BN model can predict two-year survival in non-small cell lung cancer (NSCLC) patients as accurately as SVM, but will predict survival more accurately when data are missing. Methods: A BN and SVM model were trained on 322 inoperable NSCLC patients treated with radiotherapy from Maastricht and validated in three independent data sets of 35, 47, and 33 patients from Ghent, Leuven, and Toronto. Missing variables occurred in the data set with only 37, 28, and 24 patients having a complete data set. Results: The BN model structure and parameter learning identified gross tumor volume size, performance status, and number of positive lymph nodes on a PET as prognostic factors for two-year survival. When validated in the full validation set of Ghent, Leuven, and Toronto, the BN model had an AUC of 0.77, 0.72, and 0.70, respectively. A SVM model based on the same variables had an overall worse performance (AUC 0.71, 0.68, and 0.69) especially in the Ghent set, which had the highest percentage of missing the important GTV size data. When only patients with complete data sets were considered, the BN and SVM model performed more alike. Conclusions: Within the limitations of this study, the hypothesis is supported that BN models are better at handling missing data than SVM models and are therefore more suitable for the medical domain. Future works have to focus on improving the BN performance by including more patients, more variables, and more diversity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and performance of a respiratory amplitude gating device for PET/CT imaging

Purpose: Recently, the authors proposed a free-breathing amplitude gating (FBAG) technique for PET/CT scanners. The implementation of this technique required specialized hardware and software components that were specifically designed to interface with commercial respiratory gating devices to generate the necessary triggers required for the FBAG technique. The objective of this technical note is to introduce an in-house device that integrates all the necessary hardware and software components as well as tracks the patient's respiratory motion to realize amplitude gating on PET/CT scanners. Methods: The in-house device is composed of a piezoelectric transducer coupled to a data-acquisition system in order to monitor the respiratory waveform. A LABVIEW program was designed to control the data-acquisition device and inject triggers into the PET list stream whenever the detected respiratory amplitude crossed a predetermined amplitude range. A timer was also programmed to stop the scan when the accumulated time within the selected amplitude range reached a user-set interval. This device was tested using a volunteer and a phantom study. Results: The results from the volunteer and phantom studies showed that the in-house device can detect similar respiratory signals as commercially available respiratory gating systems and is able to generate the necessary triggers to suppress respiratory motion artifacts. Conclusions: The proposed in-house device can be used to implement the FBAG technique in current PET/CT scanners.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measurement and verification of positron emitter nuclei generated at each treatment site by target nuclear fragment reactions in proton therapy

Purpose: The purpose of this study is to verify the characteristics of the positron emitter nuclei generated at each treatment site by proton irradiation. Methods: Proton therapy using a beam on-line PET system mounted on a rotating gantry port (BOLPs-RGp), which the authors developed, is provided at the National Cancer Center Kashiwa, Japan. BOLPs-RGp is a monitoring system that can confirm the activity distribution of the proton irradiated volume by detection of a pair of annihilation gamma rays coincidentally from positron emitter nuclei generated by the target nuclear fragment reactions between irradiated proton nuclei and nuclei in the human body. Activity is measured from a start of proton irradiation to a period of 200 s after the end of the irradiation. The characteristics of the positron emitter nuclei generated in a patient's body were verified by the measurement of the activity distribution at each treatment site using BOLPs-RGp. Results: The decay curves for measured activity were able to be approximated using two or three half-life values regardless of the treatment site. The activity of half-life value of about 2 min was important for a confirmation of the proton irradiated volume. Conclusions: In each proton treatment site, verification of the characteristics of the generated positron emitter nuclei was performed by using BOLPs-RGp. For the monitoring of the proton irradiated volume, the detection of {sup 15}O generated in a human body was important.

61 RADIATION PROTECTION AND DOSIMETRY↗

4D XCAT phantom for multimodality imaging research

Purpose: The authors develop the 4D extended cardiac-torso (XCAT) phantom for multimodality imaging research. Methods: Highly detailed whole-body anatomies for the adult male and female were defined in the XCAT using nonuniform rational B-spline (NURBS) and subdivision surfaces based on segmentation of the Visible Male and Female anatomical datasets from the National Library of Medicine as well as patient datasets. Using the flexibility of these surfaces, the Visible Human anatomies were transformed to match body measurements and organ volumes for a 50th percentile (height and weight) male and female. The desired body measurements for the models were obtained using the PEOPLESIZE program that contains anthropometric dimensions categorized from 1st to the 99th percentile for US adults. The desired organ volumes were determined from ICRP Publication 89 [ICRP, ''Basic anatomical and physiological data for use in radiological protection: reference values,'' ICRP Publication 89 (International Commission on Radiological Protection, New York, NY, 2002)]. The male and female anatomies serve as standard templates upon which anatomical variations may be modeled in the XCAT through user-defined parameters. Parametrized models for the cardiac and respiratory motions were also incorporated into the XCAT based on high-resolution cardiac- and respiratory-gated multislice CT data. To demonstrate the usefulness of the phantom, the authors show example simulation studies in PET, SPECT, and CT using publicly available simulation packages. Results: As demonstrated in the pilot studies, the 4D XCAT (which includes thousands of anatomical structures) can produce realistic imaging data when combined with accurate models of the imaging process. With the flexibility of the NURBS surface primitives, any number of different anatomies, cardiac or respiratory motions or patterns, and spatial resolutions can be simulated to perform imaging research. Conclusions: With the ability to produce realistic, predictive 3D and 4D imaging data from populations of normal and abnormal patients under various imaging parameters, the authors conclude that the XCAT provides an important tool in imaging research to evaluate and improve imaging devices and techniques. In the field of x-ray CT, the phantom may also provide the necessary foundation with which to optimize clinical CT applications in terms of image quality versus radiation dose, an area of research that is becoming more significant with the growing use of CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endocervical ultrasound applicator for integrated hyperthermia and HDR brachytherapy in the treatment of locally advanced cervical carcinoma

Purpose: The clinical success of hyperthermia adjunct to radiotherapy depends on adequate temperature elevation in the tumor with minimal temperature rise in organs at risk. Existing technologies for thermal treatment of the cervix have limited spatial control or rapid energy falloff. The objective of this work is to develop an endocervical applicator using a linear array of multisectored tubular ultrasound transducers to provide 3-D conformal, locally targeted hyperthermia concomitant to radiotherapy in the uterine cervix. The catheter-based device is integrated within a HDR brachytherapy applicator to facilitate sequential and potentially simultaneous heat and radiation delivery. Methods: Treatment planning images from 35 patients who underwent HDR brachytherapy for locally advanced cervical cancer were inspected to assess the dimensions of radiation clinical target volumes (CTVs) and gross tumor volumes (GTVs) surrounding the cervix and the proximity of organs at risk. Biothermal simulation was used to identify applicator and catheter material parameters to adequately heat the cervix with minimal thermal dose accumulation in nontargeted structures. A family of ultrasound applicators was fabricated with two to three tubular transducers operating at 6.6-7.4 MHz that are unsectored (360 deg.), bisectored (2x180 deg.), or trisectored (3x120 deg.) for control of energy deposition in angle and along the device length in order to satisfy anatomical constraints. The device is housed in a 6 mm diameter PET catheter with cooling water flow for endocervical implantation. Devices were characterized by measuring acoustic efficiencies, rotational acoustic intensity distributions, and rotational temperature distributions in phantom. Results: The CTV in HDR brachytherapy plans extends 20.5{+-}5.0 mm from the endocervical tandem with the rectum and bladder typically <8 mm from the target boundary. The GTV extends 19.4{+-}7.3 mm from the tandem. Simulations indicate that for 60 min treatments the applicator can heat to 41 deg. C and deliver >5EM{sub 43 Degree-Sign C} over 4-5 cm diameter with T{sub max}<45 deg. C and 1 kg m{sup -3} s{sup -1} blood perfusion. The 41 deg. C contour diameter is reduced to 3-4 cm at 3 kg m{sup -3} s{sup -1} perfusion. Differential power control to transducer elements and sectors demonstrates tailoring of heating along the device length and in angle. Sector cuts are associated with a 14-47 deg. acoustic dead zone, depending on cut width, resulting in a {approx}2-4 deg. C temperature reduction within the dead zone below T{sub max}. Dead zones can be oriented for thermal protection of the rectum and bladder. Fabricated devices have acoustic efficiencies of 33.4%-51.8% with acoustic output that is well collimated in length, reflects the sectoring strategy, and is strongly correlated with temperature distributions. Conclusions: A catheter-based ultrasound applicator was developed for endocervical implantation with locally targeted, 3-D conformal thermal delivery to the uterine cervix. Feasibility of heating clinically relevant target volumes was demonstrated with power control along the device length and in angle to treat the cervix with minimal thermal dose delivery to the rectum and bladder.

60 APPLIED LIFE SCIENCES↗

Development of a dynamic flow imaging phantom for dynamic contrast-enhanced CT

Purpose: Dynamic contrast enhanced CT (DCE-CT) studies with modeling of blood flow and tissue perfusion are becoming more prevalent in the clinic, with advances in wide volume CT scanners allowing the imaging of an entire organ with sub-second image frequency and sub-millimeter accuracy. Wide-spread implementation of perfusion DCE-CT, however, is pending fundamental validation of the quantitative parameters that result from dynamic contrast imaging and perfusion modeling. Therefore, the goal of this work was to design and construct a novel dynamic flow imaging phantom capable of producing typical clinical time-attenuation curves (TACs) with the purpose of developing a framework for the quantification and validation of DCE-CT measurements and kinetic modeling under realistic flow conditions. Methods: The phantom is based on a simple two-compartment model and was printed using a 3D printer. Initial analysis of the phantom involved simple flow measurements and progressed to DCE-CT experiments in order to test the phantoms range and reproducibility. The phantom was then utilized to generate realistic input TACs. A phantom prediction model was developed to compute the input and output TACs based on a given set of five experimental (control) parameters: pump flow rate, injection pump flow rate, injection contrast concentration, and both control valve positions. The prediction model is then inversely applied to determine the control parameters necessary to generate a set of desired input and output TACs. A protocol was developed and performed using the phantom to investigate image noise, partial volume effects and CT number accuracy under realistic flow conditionsResults: This phantom and its surrounding flow system are capable of creating a wide range of physiologically relevant TACs, which are reproducible with minimal error between experiments ({sigma}/{mu} < 5% for all metrics investigated). The dynamic flow phantom was capable of producing input and output TACs using either step function based or typical clinical arterial input function (AIF) inputs. The measured TACs were in excellent agreement with predictions across all comparison metrics with goodness of fit (R{sup 2}) for the input function between 0.95 and 0.98, while the maximum enhancement differed by no more than 3.3%. The predicted output functions were similarly accurate producing R{sup 2} values between 0.92 and 0.99 and maximum enhancement to within 9.0%. The effect of ROI size on the arterial input function (AIF) was investigated in order to determine an operating range of ROI sizes which were minimally affected by noise for small dimensions and partial volume effects for large dimensions. It was possible to establish the measurement sensitivity of both the Toshiba (ROI radius range from 1.5 to 3.2 mm ''low dose'', 1.4 to 3.0 mm ''high dose'') and GE scanner (1.5 to 2.6 mm ''low dose'', 1.1 to 3.4 mm ''high dose''). This application of the phantom also provides the ability to evaluate the effect of the AIF error on kinetic model parameter predictions. Conclusions: The dynamic flow imaging phantom is capable of producing accurate and reproducible results which can be predicted and quantified. This results in a unique tool for perfusion DCE-CT validation under realistic flow conditions which can be applied not only to compare different CT scanners and imaging protocols but also to provide a ground truth across multimodality dynamic imaging given its MRI and PET compatibility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fast IMRT with narrow high energy scanned photon beams

Purpose: Since the first publications on intensity modulated radiation therapy (IMRT) in the early 1980s almost all efforts have been focused on fairly time consuming dynamic or segmental multileaf collimation. With narrow fast scanned photon beams, the flexibility and accuracy in beam shaping increases, not least in combination with fast penumbra trimming multileaf collimators. Previously, experiments have been performed with full range targets, generating a broad bremsstrahlung beam, in combination with multileaf collimators or material compensators. In the present publication, the first measurements with fast narrow high energy (50 MV) scanned photon beams are presented indicating an interesting performance increase even though some of the hardware used were suboptimal. Methods: Inverse therapy planning was used to calculate optimal scanning patterns to generate dose distributions with interesting properties for fast IMRT. To fully utilize the dose distributional advantages with scanned beams, it is necessary to use narrow high energy beams from a thin bremsstrahlung target and a powerful purging magnet capable of deflecting the transmitted electron beam away from the generated photons onto a dedicated electron collector. During the present measurements the scanning system, purging magnet, and electron collimator in the treatment head of the MM50 racetrack accelerator was used with 3-6 mm thick bremsstrahlung targets of beryllium. The dose distributions were measured with diodes in water and with EDR2 film in PMMA. Monte Carlo simulations with geant4 were used to study the influence of the electrons transmitted through the target on the photon pencil beam kernel. Results: The full width at half-maximum (FWHM) of the scanned photon beam was 34 mm measured at isocenter, below 9.5 cm of water, 1 m from the 3 mm Be bremsstrahlung target. To generate a homogeneous dose distribution in a 10 x 10 cm{sup 2} field, the authors used a spot matrix of 100 equal intensity beam spots resulting in a uniformity of collimated 80%-20% penumbra of 9 mm at a primary electron energy of 50 MeV. For the more complex cardioid shaped dose distribution, they used 270 spots, which at a pulse repetition frequency of 200 Hz is completed every 1.36 s. Conclusions: The present measurements indicate that the use of narrow scanned photon beams is a flexible and fast method to deliver advanced intensity modulated beams. Fast scanned photon IMRT should, therefore, be a very interesting modality in the delivery of biologically optimized radiation therapy with the possibility for in vivo treatment verification with PET-CT imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of activity pencil beam algorithm using measured distribution data of positron emitter nuclei generated by proton irradiation of targets containing {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei in preparation of clinical application

Purpose: The purpose of this study is to develop a new calculation algorithm that is satisfactory in terms of the requirements for both accuracy and calculation time for a simulation of imaging of the proton-irradiated volume in a patient body in clinical proton therapy. Methods: The activity pencil beam algorithm (APB algorithm), which is a new technique to apply the pencil beam algorithm generally used for proton dose calculations in proton therapy to the calculation of activity distributions, was developed as a calculation algorithm of the activity distributions formed by positron emitter nuclei generated from target nuclear fragment reactions. In the APB algorithm, activity distributions are calculated using an activity pencil beam kernel. In addition, the activity pencil beam kernel is constructed using measured activity distributions in the depth direction and calculations in the lateral direction. {sup 12}C, {sup 16}O, and {sup 40}Ca nuclei were determined as the major target nuclei that constitute a human body that are of relevance for calculation of activity distributions. In this study, ''virtual positron emitter nuclei'' was defined as the integral yield of various positron emitter nuclei generated from each target nucleus by target nuclear fragment reactions with irradiated proton beam. Compounds, namely, polyethylene, water (including some gelatin) and calcium oxide, which contain plenty of the target nuclei, were irradiated using a proton beam. In addition, depth activity distributions of virtual positron emitter nuclei generated in each compound from target nuclear fragment reactions were measured using a beam ON-LINE PET system mounted a rotating gantry port (BOLPs-RGp). The measured activity distributions depend on depth or, in other words, energy. The irradiated proton beam energies were 138, 179, and 223 MeV, and measurement time was about 5 h until the measured activity reached the background level. Furthermore, the activity pencil beam data were made using the activity pencil beam kernel, which was composed of the measured depth data and the lateral data including multiple Coulomb scattering approximated by the Gaussian function, and were used for calculating activity distributions. Results: The data of measured depth activity distributions for every target nucleus by proton beam energy were obtained using BOLPs-RGp. The form of the depth activity distribution was verified, and the data were made in consideration of the time-dependent change of the form. Time dependence of an activity distribution form could be represented by two half-lives. Gaussian form of the lateral distribution of the activity pencil beam kernel was decided by the effect of multiple Coulomb scattering. Thus, the data of activity pencil beam involving time dependence could be obtained in this study. Conclusions: The simulation of imaging of the proton-irradiated volume in a patient body using target nuclear fragment reactions was feasible with the developed APB algorithm taking time dependence into account. With the use of the APB algorithm, it was suggested that a system of simulation of activity distributions that has levels of both accuracy and calculation time appropriate for clinical use can be constructed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗