Efficient Prompt Scintillation and Fast Neutron-Gamma Ray Discrimination Using Amorphous Blends of Difluorenylsilane Organic Glass and in-situ Polymerized Vinyltoluene

High performance radiation detection materials are an integral part of national security, medical imaging, and nuclear physics applications. Those that offer compositional and manufacturing versatility are of particular interest. In this work, we report a new family of radiological particle-discriminating scintillators containing bis(9,9-dimethyl-9H-fluoren-2- yl)diphenylsilane (compound “P2”) and in-situ polymerized vinyltoluene (PVT) that is phase stable and mechanically robust at any blend ratio. The gamma-ray light yield increases nearly linearly across the composition range, to ~16,400 photons/MeV at 75 % wt. P2. These materials are also capable of γ/n pulse shape discrimination (PSD) and between 20-50 % P2 loading are competitive with the PSD quality of commercially-available plastic scintillators. The 137 Cs scintillation rise and decay times are sensitive to P2 loading and approach the values for “pure” P2. Additionally, the radiation detection performance of P2-PVT blends can be made stable in 60°C air for at least 1.5 months with the application of a thin film of poly(vinylalcohol) to the scintillator surfaces.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Benchmark study of TRIPOLI-4 through experiment and MCNP codes

Reliability on simulation results is essential in nuclear physics. Although MCNP5 and MCNPX are the world widely used 3D Monte Carlo radiation transport codes, alternative Monte Carlo simulation tools exist to simulate neutral and charged particles' interactions with matter. Therefore, benchmark are required in order to validate these simulation codes. For instance, TRIPOLI-4.7, developed at the French Alternative Energies and Atomic Energy Commission for neutron and photon transport, now also provides the user with a full feature electron-photon electromagnetic shower. Whereas the reliability of TRIPOLI-4.7 for neutron and photon transport has been validated yet, the new development regarding electron-photon matter interaction needs additional validation benchmarks. We will thus demonstrate how accurately TRIPOLI-4's 'deposited spectrum' tally can simulate gamma spectrometry problems, compared to MCNP's 'F8' tally. The experimental setup is based on an HPGe detector measuring the decay spectrum of an {sup 152}Eu source. These results are then compared with those given by MCNPX 2.6d and TRIPOLI-4 codes. This paper deals with both the experimental aspect and simulation. We will demonstrate that TRIPOLI-4 is a potential alternative to both MCNPX and MCNP5 for gamma-electron interaction simulation. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

γ-Ray spectroscopy using a binned likelihood approach

The measurement of a reaction cross section from a pulse height spectrum is a ubiquitous problem in experimental nuclear physics. In γ-ray spectroscopy, this is accomplished frequently by measuring the intensity of full-energy primary transition peaks and correcting the intensities for experimental artifacts, such as detection efficiencies and angular correlations. Implicit in this procedure is the assumption that full-energy peaks do not overlap with any secondary peaks, escape peaks, or environmental back- grounds. However, for complex γ-ray cascades, this is often not the case. Furthermore, this technique is difficult to adapt for coincidence spectroscopy, where intensities depend not only on the detection efficiency, but also the detailed decay scheme. We present a method that incorporates the intensities of the entire spectrum (e.g., primary and secondary transition peaks, escape peaks, Compton continua, etc.) into a statistical model, where the transition intensities and branching ratios can be determined using Bayesian statistical inference. This new method provides an elegant solution to the difficulties associated with analyzing coincidence spectra. Finally, we describe it in detail and examine its efficacy in the analysis of 18 O(p,γ) 19 F and 25 Mg(p,γ) 26 Al resonance data. For the 18 O(p,γ) 19 F reaction, the measured branching ratios improve upon the literature values, with a factor of 3 reduction in the uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new, analytic, non-perturbative, gauge-invariant formulation of realistic QCD

This Formulation [1], [2], [3] is New, in the sense that it is less than 3 years old. But it could have been done decades ago, since the input information existed, but was overlooked. It is Analytic in the sense that physically-reasonable approximations can be estimated with paper and pencil; and exact amplitudes can be calculated as Meijer G-functions of various orders. It is Non-Perturbative in the sense that sums over all possible gluon exchanges between any pair of quarks and/or antiquarks, including cubic and quartic gluon interactions, are exactly performed. These multiple gluon exchanges combine into 'Gluon Bundles' (GBs), as sums over Feynman graphs with finite numbers of exchanged gluons are replaced by {sup B}undle Graphs{sup .} In effect, gluons disappear from the formalism, and GBs remain as the effective carrier of all interactions between quark lines. A simple re-arrangement of the Schwinger/Symanzik functional solution for the Generating Functional of QCD - a rearrangement possible in QCD but not in QED - produces a formal statement of Gauge-Invariance, even though the formulation contains gauge-dependent gluon propagators. After the non-perturbative sums produce GBs, one sees explicit cancelation of all gauge-dependent gluon propagators; gauge-invariance is achieved as gauge-independence. A new insight into Realistic QCD appears in the non-perturbative domain, because quarks do not have individual asymptotic states; they are always asymptotically bound, and their transverse coordinates cannot, in principle, be measured exactly. 'Transverse Imprecision' is introduced into the basic Lagrangian, and quark-binding potentials for the construction of mesons and nucleons can then be defined and evaluated. And the greatest surprise of all: A new, non-perturbative property appears, called Effective Locality, with the result that all functional integrals reduce to (a few) sets of ordinary integrals, easy to estimate approximately, or calculate on a desk-top computer. A fantastic simplification{exclamation_point} With the aid of the above techniques, this presentation will describe each of the above paragraphs, with explicit descriptions of gauge-invariance, of the summation of all relevant Feynman graphs, of quark-binding into hadrons, and of nucleon-nucleon binding to form a deuteron. To our knowledge, the latter calculation is the first analytic example of Nuclear Physics obtained directly from basic QCD.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulating gas-filled neutron detector responses with DRiFT

– Gas-filled neutron detectors have numerous applications across the nuclear engineering and nuclear physics fields. The ability to accurately model and simulate these detectors is important for those applications but is currently limited by the lack of readily-useable detector response software. Recently, the capabilities of DRiFT, a Detector Response Function Toolkit, were expanded to model gas-filled, He-3 and BF3, neutron detectors so that, combined with the radiation transport capabilities of the MCNP code, a high-fidelity treatment of gas-filled neutron detectors can be obtained. Further, this model has been validated by an experiment carried out with the Epithermal Neutron Multiplicity Counter and its capabilities have been demonstrated in two additional experiments. This work shows that utilizing DRiFT to post-process MCNP outputs produces more accurate results than using the MCNP code alone, reducing the difference between experimental and simulated results for measurements taken near the end of a He-3 tube, where the MCNP code struggles to model inactive regions of the detector, from a maximum of 35% with the MCNP code alone to 15% with the MCNP code plus DRiFT. DRiFT's diagnostic capabilities are also demonstrated with measurements for scenarios when pulse pileup or room return effects are significant and must be considered. Altogether, these measurements underpin the ability of DRiFT to accurately model and predict the behavior of gas-filled neutron detectors, making it a valuable tool for the design and testing of systems and experiments that utilize these detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High Resolution, Non-Dispersive X-Ray Calorimeter Spectrometers on EBITs and Orbiting Observatories

X-ray spectroscopy is the primary tool for performing atomic physics with Electron beam ion trap (EBITs). X-ray instruments have generally fallen into two general categories, 1) dispersive instruments with very high spectral resolving powers but limited spectral range, limited count rates, and require an entrance slit, generally, for EBITs, defined by the electron beam itself, and 2) non-dispersive solid-state detectors with much lower spectral resolving powers but that have a broad dynamic range, high count rate ability and do not require a slit. Both of these approaches have compromises that limit the type and efficiency of measurements that can be performed. In 1984 NASA initiated a program to produce a non-dispersive instrument with high spectral resolving power for x-ray astrophysics based on the cryogenic x-ray calorimeter. This program produced the XRS non-dispersive spectrometers on the Astro-E, Astro-E2 (Suzaku) orbiting observatories, the SXS instrument on the Astro-H observatory, and the planned XMS instrument on the International X-ray Observatory. Complimenting these spaceflight programs, a permanent high-resolution x-ray calorimeter spectrometer, the XRS/EBIT, was installed on the LLNL EBIT in 2000. This unique instrument was upgraded to a spectral resolving power of 1000 at 6 keV in 2003 and replaced by a nearly autonomous production-class spectrometer, the EBIT Calorimeter Spectrometer (ECS), in 2007. The ECS spectrometer has a simultaneous bandpass from 0.07 to over 100 keV with a spectral resolving power of 1300 at 6 keV with unit quantum efficiency, and 1900 at 60 keV with a quantum efficiency of 30%. X-ray calorimeters are event based, single photon spectrometers with event time tagging to better than 10 us. We are currently developing a follow-on instrument based on a newer generation of x-ray calorimeters with a spectral resolving power of 3000 at 6 keV, and improved timing and measurement cadence. The unique capabilities of the x-ray calorimeter spectrometer, coupled with higher spectral resolution dispersive spectrometers to resolve line blends, has enabled many science investigations, to date mostly in our x-ray laboratory astrophysics program. These include measurements of absolute cross sections for Land K shell emission from Fe and Ni, charge exchange measurements in many astrophysically abundant elements, lifetime measurements, line ratios, and wavelength measurements. In addition, we have performed many additional measurements in nuclear physics, and in support of diagnostics for laser fusion, for example. In this presentation we will give a detailed overview of x-ray calorimeter instruments in general and in our EBIT laboratory astrophysics program in particular. We will also discuss the science yield of our measurements at EBIT over the last decade) prospects for future science enabled by the current generation of spectrometers and that will be expanded in the near future by the next generation of spectrometers starting in 2611.

Porter, Frederick S.↗

Time Resolution Measurements of EJ-232Q With Single- and Dual-Sided Readouts

In view of its importance to applications in high energy physics, nuclear security, and time-of-flight PET, the time resolution of 0.5% benzophenone-quenched EJ-232Q plastic scintillators of various lengths was studied using a fast waveform digitizer and fast PMTs. The scintillator sizes were 5 mm × 5 mm × 10, 25, 50, 75, or 100 mm. First, the timing measurements were performed by using a single PMT reading out one end. The degradation in time resolution with increasing scintillator length was studied. The irradiation geometry was also observed to have a non-negligible impact on the time resolution due to the variation of depth-of-interaction positions, especially for the scintillators with a high aspect ratio. Second, two PMTs were employed for a dual-sided readout. This readout together with the mean time method was demonstrated to be an effective approach to improve the timing performance since the depth-of-interaction-related effect was considerably mitigated. A time resolution of 79 ± 1 ps (full-width at half-maximum) has been achieved for the 5 × 5 × 10 mm 3 scintillator. The 5 × 5 × 100 mm 3 scintillator can still provide a time resolution as good as 172 ± 1 ps. Here, the energy range used for each was between 340 keVee and 450 keVee. In addition, the time information from individual PMTs in a dual-sided readout was able to show a time resolution almost identical to that determined with the mean-time-based technique after correcting for the depth-of-interaction variation for the 100 mm long scintillator.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A composite position independent monitor of reactor fuel irradiation using Pu, Cs, and Ba isotope ratios

When post-irradiation materials from the nuclear fuel cycle are released to the environment, certain isotopes of actinides and fission products carry signatures of irradiation history that can potentially aid a nuclear forensic investigation into the material's provenance. In this study, combinations of Pu, Cs, and Ba isotope ratios that produce position (in the reactor core) independent monitors of irradiation history in spent light water reactor fuel are identified and explored. These position independent monitors (PIMs) are modeled for various irradiation scenarios using automated depletion codes as well as ordinary differential equation solutions to approximate nuclear physics models. Experimental validation was performed using irradiated low enriched uranium oxide fuel from a light water reactor, which was sampled at 8 axial positions from a single rod. Plutonium, barium and cesium were chemically separated and isotope ratio measurements of the separated solutions were made by quadrupole and multi-collector inductively coupled mass spectrometry (Cs and Pu, respectively) and thermal ionization mass spectrometry (Ba). The effect of axial variations in neutron fluence and energy spectrum are evident in the measured isotope ratios. Furthermore, two versions of a combined Pu and Cs based PIM are developed. A linear PIM model, which can be used to solve for irradiation time is found to work well for natural U fuel with <10% 240 Pu and known or short cooling times. A non-linear PIM model, which cannot be solved explicitly for irradiation time without additional information, can nonetheless still group samples by irradiation history, including high burnup LEU fuel with unknown cooling time. 137 Ba/ 138 Ba is also observed to act as a position independent monitor; it is nearly single valued across the sampled fuel rod, indicating that samples sharing an irradiation history (same irradiation time and cooling time) in a reactor despite experiencing different neutron fluxes will have a common 137 Ba/ 138 Ba ratio. Modeling of this Ba PIM shows it increases monotonically with irradiation and cooling time, and a confirmatory first order analytical solution is also presented.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constraining the Synthesis of the Lightest 𝑝 Nucleus 74 Se

We provide the first experimental cross section of the 73 As(p, γ) 74 Se reaction to constrain one of the main destruction mechanisms of the p nucleus 74 Se in explosive stellar environments. The measurement was done using a radioactive 73 As beam at incident energies of 3.1 and 3.7 MeV/nucleon. Along with the total cross section measurement, statistical properties of the 74 Se compound nucleus were extracted, constraining the reaction cross section across the entire Gamow window of the γ process. The impact of the experimentally constrained reaction rate on 74 Se production in Type II supernovae is investigated through Monte Carlo one-zone network simulations. The results indicate that the overproduction of 74 Se by Type II supernova models cannot be resolved by nuclear physics and point towards the description of the astrophysical conditions of the γ process.

59 ≤ A ≤ 89↗

A new class of accelerated kinetic Monte Carlo algorithms

Kinetic ( aka dynamic) Monte Carlo (KMC) is a powerful method for numerical simulations of time dependent evolution applied in a wide range of contexts including biology, chemistry, physics, nuclear sciences, financial engineering, etc. Generally, in a KMC the time evolution takes place one event at a time, where the sequence of events and the time intervals between them are selected (or sampled) using random numbers. While details of the method implementation vary depending on the model and context, there exist certain common issues that limit KMC applicability in almost all applications. Among such is the notorious 'flicker problem' where the same states of the systems are repeatedly visited but otherwise no essential evolution is observed. In its simplest form the flicker problem arises when two states are connected to each other by transitions whose rates far exceed the rates of all other transitions out of the same two states. In such cases, the model will endlessly hop between the two states otherwise producing no meaningful evolution. In most situation of practical interest, the trapping cluster includes more than two states making the flicker somewhat more difficult to detect and to deal with. Several methods have been proposed to overcome or mitigate the flicker problem, exactly or approximately. Of the exact methods, the one proposed by Novotny is perhaps most relevant to our research. Novotny formulates the problem of escaping from a trapping cluster as a Markov system with absorbing states. Given an initial state inside the cluster, it is in principle possible to solve the Master Equation for the time dependent probabilities to find the walker in a given state (transient or absorbing) of the cluster at any time in the future. Novotny then proceeds to demonstrate implementation of his general method to trapping clusters containing the initial state plus one or two transient states and all of their absorbing states. Similar methods have been subsequently proposed in [refs] but applied in a different context. The most serious deficiency of the earlier methods is that size of the trapping cluster size is fixed and often too small to bring substantial simulation speedup. Furthermore, the overhead associated with solving for the probability distribution on the trapping cluster sometimes makes such simulations less efficient than the standard KMC. Here we report on a general and exact accelerated kinetic Monte Carlo algorithm generally applicable to arbitrary Markov models1. Two different implementations are attempted both based on incremental expansion of trapping sub-set of Markov states: (1) numerical solution of the Master Equation with absorbing states and (2) incremental graph reduction followed by randomization. Of the two implementations, the 2nd one performs better allowing, for the first time, to overcome trapping basins spanning several million Markov states. The new method is used for simulations of anomalous diffusion on a 2D substrate and of the kinetics of diffusive 1st order phase transformations in binary alloys. Depending on temperature and (alloy) super-saturation conditions, speedups of 3 to 7 orders of magnitude are demonstrated, with no compromise of simulation accuracy.

97 MATHEMATICS AND COMPUTING↗

DUNE atmospheric neutrinos: Earth tomography

In this paper we show that the DUNE experiment can measure the Earth’s density profile by analyzing atmospheric neutrino oscillations. The crucial feature that enables such measurement is the detailed event reconstruction capability of liquid argon time projection chambers. This allows for studying the sub-GeV atmospheric neutrino component, which bears a rich oscillation phenomenology, strongly dependent on the matter potential sourced by the Earth. We provide a pedagogical discussion of the MSW and parametric resonances and their role in measuring the core and mantle densities. By performing a detailed simulation, accounting for particle reconstruction at DUNE, nuclear physics effects relevant to neutrino-argon interactions and several uncertainties on the atmospheric neutrino flux, we manage to obtain a robust estimate of DUNE’s sensitivity to the Earth matter profile. We find that DUNE can measure the total mass of the Earth at 9.3% precision with an exposure of 400 kton-year. By accounting for previous measurements of the total mass and moment of inertia of the Earth, the core, lower mantle and upper mantle densities can be determined with 9%, 14% and 22% precision, respectively, for the same exposure. Finally, for a low exposure run of 60 kton-year, which would correspond to two far detectors running for three years, we have found that the core density could be measured by DUNE at ∼ 30% precision.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Is infrared-collinear safe information all you need for jet classification?

Machine learning-based jet classifiers are able to achieve impressive tagging performance in a variety of applications in high-energy and nuclear physics. However, it remains unclear in many cases which aspects of jets give rise to this discriminating power, and whether jet observables that are tractable in perturbative QCD such as those obeying infrared-collinear (IRC) safety serve as sufficient inputs. In this article, we introduce a new classifier, Jet Flow Networks (JFNs), in an effort to address the question of whether IRC unsafe information provides additional discriminating power in jet classification. JFNs are permutation-invariant neural networks (deep sets) that take as input the kinematic information of reconstructed subjets. The subjet radius and a cut on the subjet’s transverse momenta serve as tunable hyperparameters enabling a controllable sensitivity to soft emissions and nonperturbative effects. We demonstrate the performance of JFNs for quark vs. gluon and Z vs. QCD jet tagging. For small subjet radii and transverse momentum cuts, the performance of JFNs is equivalent to the IRC-unsafe Particle Flow Networks (PFNs), demonstrating that infrared-collinear unsafe information is not necessary to achieve strong discrimination for both cases. As the subjet radius is increased, the performance of the JFNs remains essentially unchanged until physical thresholds that we identify are crossed. For relatively large subjet radii, we show that the JFNs may offer an increased model independence with a modest tradeoff in performance compared to classifiers that use the full particle information of the jet. These results shed new light on how machines learn patterns in high-energy physics data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Supernova 1987A constraints on sub-GeV dark sectors, millicharged particles, the QCD axion, and an axion-like particle

Here, we consider the constraints from Supernova 1987A on particles with small couplings to the Standard Model. We discuss a model with a fermion coupled to a dark photon, with various mass relations in the dark sector; millicharged particles; dark-sector fermions with inelastic transitions; the hadronic QCD axion; and an axion-like particle that couples to Standard Model fermions with couplings proportional to their mass. In the fermion cases, we develop a new diagnostic for assessing when such a particle is trapped at large mixing angles. Our bounds for a fermion coupled to a dark photon constrain small couplings and masses ≲ 200 MeV, and do not decouple for low fermion masses. They exclude parameter space that is otherwise unconstrained by existing accelerator-based and direct-detection searches. In addition, our bounds are complementary to proposed laboratory searches for sub-GeV dark matter, and do not constrain several benchmark-model targets in parameter space for which the dark matter obtains the correct relic abundance from interactions with the Standard Model. For a millicharged particle, we exclude charges between 10 –9 –few×10 –6 in units of the electron charge, also for masses ≲ 200 MeV; this excludes parameter space to higher millicharges and masses than previous bounds. For the QCD axion and an axion-like particle, we apply several updated nuclear physics calculations and include the energy dependence of the optical depth to accurately account for energy loss at large couplings. These corrections allow us to rule out a hadronic axion of mass between 0.1 and a few hundred eV, or equivalently to put a bound on the scale of Peccei-Quinn symmetry breaking between a few×10 4 and 10 8 GeV, closing the hadronic axion window. For an axion-like particle, our bounds disfavor decay constants between a few×10 5 GeV up to a few×10 8 GeV, for a mass ≲ 200 MeV. In all cases, our bounds differ from previous work by more than an order of magnitude across the entire parameter space. We also provide estimated systematic errors due to the uncertainties of the progenitor.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Fitting a deep generative hadronization model

Hadronization is a critical step in the simulation of high-energy particle and nuclear physics experiments. As there is no first principles understanding of this process, physically-inspired hadronization models have a large number of parameters that are fit to data. Deep generative models are a natural replacement for classical techniques, since they are more flexible and may be able to improve the overall precision. Proof of principle studies have shown how to use neural networks to emulate specific hadronization when trained using the inputs and outputs of classical methods. However, these approaches will not work with data, where we do not have a matching between observed hadrons and partons. In this paper, we develop a protocol for fitting a deep generative hadronization model in a realistic setting, where we only have access to a set of hadrons in data. Our approach uses a variation of a Generative Adversarial Network with a permutation invariant discriminator. We find that this setup is able to match the hadronization model in Herwig with multiple sets of parameters. This work represents a significant step forward in a longer term program to develop, train, and integrate machine learning-based hadronization models into parton shower Monte Carlo programs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nucleon resonances: From photoproduction to high photon virtualities

Here, the topical workshop “Nucleon Resonances: From Photoproduction to High Photon Virtualities” took place at the European Center for Theoretical Studies in Nuclear Physics and Related Areas in Trento, Italy from October 12–16, 2015. The organizing committee consisted of R.W. Gothe (Chair, USC), V.I. Mokeev (Jefferson Lab), and E. Santopinto (INFN).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The GlueX Experiment: First Results

GlueX is a nuclear physics experiment located at the Thomas Jefferson National Accelerator Facility designed to study and understand the nature of confinement in QCD by mapping the spectrum of exotic mesons. The experiment will be able to probe new areas by using photoproduction, i.e. the scattering on nucleon of ~9 GeV linearly polarized photons derived from the recently upgraded CEBAF with a 12 GeV electron beam. Spring 2016 has been characterized by a continued detector commissioning and initial running at the full design energy. The current status of the GlueX detector performance and data collection will be discussed, with a brief overview of first physics results, future run plans, and long term upgrades.