Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The effect of local dipole moments on the structure and lattice dynamics of K0.98Li0.02TaO3

We present high energy x-ray (67 keV) and neutron scattering measurements on a single crystal of K1−xLixTaO3 for which the Li content (x = 0.02) is less than xc = 0.022, the critical value below which no structural phase transitions have been reported in zero field. While the crystal lattice does remain cubic down to T = 10K under both zero-field and field-cooled (E 4 kV/cm) conditions, indications of crystal symmetry lowering are seen at TC = 63K where the Bragg peak intensity changes significantly. A strong and frequencydependent dielectric permittivity is observed at ambient pressure, a defining characteristic of relaxors. However an extensive search for static polar nanoregions, which is also widely associated with relaxor materials, detected no evidence of elastic neutron diffuse scattering between 300 K and 10 K. Neutron inelastic scattering methods were used to characterize the transverse acoustic and optic phonons (TA1 and TO1 modes) near the (200) and (002) Bragg peaks. The zone center TO1 mode softens monotonically with cooling but never reaches zero energy in either zero field or in external electric fields of up to 4 kV/cm. These results are consistent with the behavior expected for a dipolar glass in which the local polar moments are frozen and exhibit no long-range order at low temperatures.

36 MATERIALS SCIENCE↗

X- and γ-ray pulsations of the nearby radio-faint PSR J1741–2054

We report the results of a deep XMM-Newton observation of the radio-faint γ-ray pulsar J1741–2054 and its nebula together with the analysis of five years of Fermi Large Area Telescope (LAT) data. The X-ray spectrum of the pulsar is consistent with an absorbed power law plus a blackbody, originating at least partly from the neutron star cooling. The nebular emission is consistent with that of a synchrotron pulsar wind nebula, with hints of spatial spectral variation. We extended the available Fermi LAT ephemeris and folded the γ-ray and X-ray data. We detected X-ray pulsations from the neutron star: both the thermal and non-thermal components are ∼35%-40% pulsed, with phase-aligned maxima. A sinusoid fits the thermal-folded profile well. A 10 bin phase-resolved analysis of the X-ray emission shows softening of the non-thermal spectrum during the on-pulse phases. The radio, X-ray, and γ-ray light curves are single-peaked, not phase-aligned, with the X-ray peak trailing the γ-ray peak by more than half a rotation. Spectral considerations suggest that the most probable pulsar distance is in the 0.3-1.0 kpc range, in agreement with the radio dispersion measure.

79 ASTRONOMY AND ASTROPHYSICS↗

NICER X-ray Observations of Seven Nearby Rotation-powered Millisecond Pulsars

The Neutron star Interior Composition Explorer observed several rotation-powered millisecond pulsars (MSPs) to search for or confirm the presence of X-ray pulsations. When broad and sine-like, these pulsations may indicate thermal emission from hot polar caps at the magnetic poles on the neutron star surface. We report confident detections (≥4.7σ after background filtering) of X-ray pulsations for five of the seven pulsars in our target sample: PSR J0614−3329, PSR J0636+5129, PSR J0751+1807, PSR J1012+5307, and PSR J2241−5236, while PSR J1552+5437 and PSR J1744−1134 remain undetected. Of those, only PSR J0751+1807 and PSR J1012+5307 had pulsations previously detected at the 1.7σ and almost 3σ confidence levels, respectively, in XMM-Newton data. All detected sources exhibit broad sine-like pulses, which are indicative of surface thermal radiation. As such, these MSPs are promising targets for future X-ray observations aimed at constraining the neutron star mass–radius relation and the dense matter equation of state using detailed pulse profile modeling. Furthermore, we find that three of the detected MSPs exhibit a significant phase offset between their X-ray and radio pulses.

Sebastien Guillot↗

Doping the 1 kton Large Volume Detector with Gd

The Large Volume Detector (LVD) in the INFN Gran Sasso National Laboratory (LNGS), Italy, is a ν observatory which has been monitoring the Galaxy since June 1992 to study neutrinos from core collapse supernovae. The experiment in the present configuration is made by 840 scintillator detectors, for a total active mass of 1000 tons. The detector sensitivity to neutrino bursts due to a core collapse supernova has been already discussed in term of maximum detectable distance. In this paper we evaluate the improvements that LVD could obtain if all its active scintillator mass was doped with a small amount (0.14% in weight) of Gadolinium. We simulated neutron captures following ν-bar {sub e} inverse beta decay reactions in one LVD counter (1.2 ton) with Gd doped liquid scintillator obtaining an efficiency for the detection of this process of η{sub n}|{sub Gd} = 80% and a mean capture time τ = 25μs, in good agreement with the results obtained by the measures. This implies a gain of a factor ∼ 20 in the signal to noise ratio for neutron capture detection with respect to the undoped liquid scintillator. We discuss how the captures of neutrons from rock radioactivity on Gd modify the background conditions of the detector and we calculate the curves expressing the sensitivity to a ν-bar {sub e} burst from core collapse supernovae depending on the distance of the collapsing star. It results that doping the 1 kton Large Volume Detector with Gd would assure a 90% detection efficiency at the distance of the Large Magellanic Cloud (50 kpc), an achievement which is equivalent to that obtained by doubling the number of counters in LVD.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Semiconductor neutron detectors using depleted uranium oxide

This paper reports on recent attempts to develop and test a new type of solid-state neutron detector fabricated from uranium compounds. It has been known for many years that uranium oxide (UO2), triuranium octoxide (U3O8) and other uranium compounds exhibit semiconducting characteristics with a broad range of electrical properties. We seek to exploit these characteristics to make a direct-conversion semiconductor neutron detector. In such a device a neutron interacts with a uranium nucleus, inducing ssion. The ssion products deposit energy-producing, detectable electron-hole pairs. The high energy released in the ssion reaction indicates that noise discrimination in such a device has the potential to be excellent. Schottky devices were fabricated using a chemical deposition coating technique to deposit UO2 layers a few microns thick on a sapphire substrate. Schottky devices have also been made using a single crystal from UO2 samples approximately 500 microns thick. Neutron sensitivity simulations have been performed using GEANT4. Neutron sensitivity for the Schottky devices was tested experimentally using a 252Cf source.

neutron detection, uranium oxide, semiconductor↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗

INTEGRAL Detection of the First Prompt Gamma-Ray Signal Coincident with the Gravitational-wave Event GW170817

We report the INTernational Gamma-ray Astrophysics Laboratory ( INTEGRAL ) detection of the short gamma-ray burst GRB 170817A (discovered by Fermi -GBM) with a signal-to-noise ratio of 4.6, and, for the first time, its association with the gravitational waves (GWs) from binary neutron star (BNS) merging event GW170817 detected by the LIGO and Virgo observatories. The significance of association between the gamma-ray burst observed by INTEGRAL and GW170817 is 3.2σ, while the association between the Fermi -GBM and INTEGRAL detections is 4.2σ. GRB 170817A was detected by the SPI-ACS instrument about 2 s after the end of the GW event. We measure a fluence of (1.4 ± 0.4 ± 0.6) × 10{sup −7} erg cm{sup −2} (75–2000 keV), where, respectively, the statistical error is given at the 1σ confidence level, and the systematic error corresponds to the uncertainty in the spectral model and instrument response. We also report on the pointed follow-up observations carried out by INTEGRAL , starting 19.5 hr after the event, and lasting for 5.4 days. We provide a stringent upper limit on any electromagnetic signal in a very broad energy range, from 3 keV to 8 MeV, constraining the soft gamma-ray afterglow flux to <7.1 × 10{sup −11} erg cm{sup −2} s{sup −1} (80–300 keV). Exploiting the unique capabilities of INTEGRAL , we constrained the gamma-ray line emission from radioactive decays that are expected to be the principal source of the energy behind a kilonova event following a BNS coalescence. Finally, we put a stringent upper limit on any delayed bursting activity, for example, from a newly formed magnetar.

79 ASTRONOMY AND ASTROPHYSICS↗

Single-Volume Neutron Scatter Camera for High-Efficiency Neutron Imaging and Source Characterization. Year 2 of 3 Summary

The neutron scatter camera (NSC), an imaging spectrometer for fission energy neutrons, is an established and proven detector for nuclear security applications such as weak source detection of special nuclear material (SNM), arms control treaty verification, and emergency response. Relative to competing technologies such as coded aperture imaging, time-encoded imaging, neutron time projection chamber, and various thermal neutron imagers, the NSC provides excellent event-by-event directional information for signal/background discrimination, reasonable imaging resolution, and good energy resolution. Its primary drawback is very low detection efficiency due to the requirement for neutron elastic scatters in two detector cells. We will develop a singlevolume double-scatter neutron imager, in which both neutron scatters can occur in the same large active volume. If successful, the efficiency will be dramatically increased over the current NSC cell-based geometry. If the detection efficiency approaches that of e.g. coded aperture imaging, the other inherent advantages of double-scatter imaging would make it the most attractive fast neutron detector for a wide range of security applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Star Astronomy in the era of the European Extremely Large Telescope

About 25 isolated neutron stars (INSs) are now detected in the optical domain, mainly thanks to the HST and to VLT-class telescopes. The European Extremely Large Telescope(E-ELT) will yield {approx}100 new identifications, many of which from the follow-up of SKA, IXO, and Fermi observations. Moreover, the E-ELT will allow to carry out, on a much larger sample, INS observations which still challenge VLT-class telescopes, enabling studies on the structure and composition of the NS interior, of its atmosphere and magnetosphere, as well as to search for debris discs. In this contribution, I outline future perspectives for NS optical astronomy with the E-ELT.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental study of the {beta}-delayed neutron decay of {sup 21}N

The first spectroscopic study for the {beta} decay of {sup 21}N is carried out based on {beta}-n, {beta}-{gamma}, and {beta}-n-{gamma} coincidence measurements. The neutron-rich {sup 21}N nuclei are produced by the fragmentation of the E/A=68.8 MeV {sup 26}Mg primary beam on a thick {sup 9}Be target and are implanted into a thin plastic scintillator that also plays the role of {beta} detector. The time of flight of the emitted neutrons following the {beta} decay are measured by the surrounding neutron sphere and neutron wall arrays. In addition, four clover germanium detectors are used to detect the {beta}-delayed {gamma} rays. Thirteen new {beta}-delayed neutron groups are observed with a total branching ratio of 90.5{+-}4.2%. The half-life for the {beta} decay of {sup 21}N is determined to be 82.9{+-}7.5 ms. The level scheme of {sup 21}O is deduced up to about 9 MeV excitation energy. The experimental results for the {beta} decay of {sup 21}N are compared to the shell-model calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

THE ORIGIN AND EVOLUTION OF THE HALO PN BoBn 1: FROM A VIEWPOINT OF CHEMICAL ABUNDANCES BASED ON MULTIWAVELENGTH SPECTRA

We have performed a comprehensive chemical abundance analysis of the extremely metal-poor ([Ar/H] < -2) halo planetary nebula (PN) BoBn 1 based on International Ultraviolet Explorer archive data, Subaru/High-Dispersion Spectrograph spectra, VLT/UVES archive data, and Spitzer/IRS spectra. We have detected over 600 lines in total and calculated ionic and elemental abundances of 13 elements using detected optical recombination lines (ORLs) and collisionally excited lines (CELs). The estimations of C, N, O, and Ne abundances from the ORLs and Kr, Xe, and Ba from the CELs are done the first for this nebula, empirically and theoretically. The C, N, O, and Ne abundances from ORLs are systematically larger than those from CELs. The abundance discrepancies apart from O could be explained by a temperature fluctuation model, and that of O might be by a hydrogen-deficient cold component model. We have detected five fluorine and several slow neutron capture elements (the s-process). The amounts of [F/H], [Kr/H], and [Xe/H] suggest that BoBn 1 is the most F-rich among F-detected PNe and is a heavy s-process element rich PN. We have confirmed dust in the nebula that is composed of amorphous carbon and polycyclic aromatic hydrocarbons with a total mass of 5.8 x 10{sup -6} M{sub sun}. The photoionization models built with non-LTE theoretical stellar atmospheres indicate that the progenitor was a 1-1.5 M{sub sun} star that would evolve into a white dwarf with an {approx}0.62 M{sub sun} core mass and {approx}0.09 M{sub sun} ionized nebula. We have measured a heliocentric radial velocity of +191.6 {+-}1.3 km s{sup -1} and expansion velocity 2V{sub exp} of 40.5 {+-} 3.3 km s{sup -1} from an average over 300 lines. The derived elemental abundances have been reviewed from the standpoint of theoretical nucleosynthesis models. It is likely that the elemental abundances except N could be explained either by a 1.5 M{sub sun} single star model or by a binary model composed of 0.75 M{sub sun} + 1.5 M{sub sun} stars. Careful examination implies that BoBn 1 has evolved from a 0.75 M{sub sun} + 1.5 M{sub sun} binary and experienced coalescence during the evolution to become a visible PN, similar to the other extremely metal-poor halo PN, K 648 in M 15.

79 ASTRONOMY AND ASTROPHYSICS↗

Monte Carlo Uncertainty Quantification in UF 6 Cylinder Neutron Emissions

In order to provide timely detection of the diversion of nuclear material, the international community needs to develop technology for safeguarding the entire fuel cycle. As such, there is significant interest in securing the front end of the fuel cycle through precise and accurate material accountancy prior to fuel irradiation. One particularly attractive solution for such problems is the development of unattended enrichment verification monitors for uranium hexafluoride (UF 6 ) transit cylinders. Systems such as the Unattended Cylinder Verification Station (UCVS) promise to provide independent nuclear material accountancy (i.e. measurements of relative enrichment, 235 U mass and total uranium mass) for all UF 6 cylinders entering and/or leaving any enrichment or fuel fabrication facilities.

07 ISOTOPE AND RADIATION SOURCES↗

BROADBAND X-RAY SPECTRAL INVESTIGATIONS OF MAGNETARS, 4U 0142+61, 1E 1841–045, 1E 2259+586, AND 1E 1048.1–5937

We have generated an extended version of a rather simplified but physically oriented three-dimensional magnetar emission model, STEMS3D, to allow spectral investigations up to 100 keV. We then applied our model to the broadband spectra of four magnetars: 4U 0142+61, 1E 1841–045, 1E 2259+586, and 1E 1048.1–5937, using data collected with Swift/XRT or XMM-Newton in soft X-rays, and the Nuclear Spectroscopic Telescope Array in the hard X-ray band. We found that the hard X-ray emission of 4U 0142+61 was spectrally hard compared to earlier detections, indicating that the source was likely in a transition to or from a harder state. We find that the surface properties of the four magnetars are consistent with what we have obtained using only the soft X-ray data with STEMS3D, implying that our physically motivated magnetar emission model is a robust tool. Based on our broadband spectral investigations, we conclude that resonant scattering of the surface photons in the magnetosphere alone cannot account for the hard X-ray emission in magnetars; therefore, an additional non-thermal process, or a population of relativistic electrons is required. We also discuss the implication of the non-detection of persistent hard X-ray emission in 1E 1048.1–5937.

79 ASTRONOMY AND ASTROPHYSICS↗

{sup 241}Am(n,{gamma}) cross section in the neutron energy region between 0.02 eV and 300 keV

The Detector for Advanced Neutron Capture Experiments (DANCE) at Los Alamos National Laboratory (LANL) was used for a neutron capture cross section measurement on {sup 241}Am. The high granularity of the DANCE array (160 BaF2 detectors in a 4{pi} geometry) enables an efficient detection of prompt gamma rays following neutron capture. The preliminary results on the {sup 241}Am(n,{gamma}) cross section are presented from 0.02 eV to 300 keV. The cross section at thermal energy E{sub n} = 0.0253 eV was determined to be 665{+-}33 barns. Resonance parameters were obtained using the SAMMY7 fit to the measured cross section in the resonance region. Significant discrepancies were found between our results and data evaluations for the first three lowest lying resonances. The cross section for neutrons with E{sub n}>l keV agrees well with the ENDF/B-VII.0 and JENDL-3.3 evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Channeling of Neutrons in the Potential Well of a Planar Waveguide

The channeling of neutrons in a three-layer planar waveguide with a neutron-optical potential well is studied. Neutrons incident on a sample surface, which propagate in a middle layer and escape from the waveguide end in the form of a narrow divergent beam, are detected. The decay parameter of a neutron wave inside the waveguide is measured as a function of the potential well depth. Experimental results are compared with a theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Methodology and Software for Gross Defect Detection of Spent Nuclear Fuel at the Atucha-I Reactor [Novel Methodology and Software for Spent Fuel Gross Defect Detection at the Atucha-I Reactor]

Here, fuel assemblies in the spent fuel pool are stored by suspending them in two vertically stacked layers at the Atucha Unit 1 nuclear power plant (Atucha-I). This introduces the unique problem of verifying the presence of fuel in either layer without physically moving the fuel assemblies. Given that the facility uses both natural uranium and slightly enriched uranium at 0.85 wt% 235 U and has been in operation since 1974, a wide range of burnups and cooling times can exist in any given pool. A gross defect detection tool, the spent fuel neutron counter (SFNC), has been used at the site to verify the presence of fuel up to burnups of 8000 MWd/t. At higher discharge burnups, the existing signal processing software of the tool was found to fail due to nonlinearity of the source term with burnup.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗