Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The ORNL analysis technique for extracting β -delayed multi-neutron branching ratios with BRIKEN

Here, many choices are available in order to evaluate large radioactive decay networks. There are many parameters that influence the calculated -decay delayed single and multi-neutron emission branching fractions. We describe assumptions about the decay model, background, and other parameters and their influence on β-decay delayed multi-neutron emission analysis. An analysis technique, the ORNL BRIKEN analysis procedure, for determining -delayed multi-neutron branching ratios in β-neutron precursors produced by means of heavy-ion fragmentation is presented. The technique is based on estimating the initial activities of zero, one, and two neutrons occurring in coincidence with an ion-implant and β trigger. The technique allows one to extract β-delayed multi-neutron decay branching ratios measured with the 3 He BRIKEN neutron counter. As an example, two analyses of the -neutron emitter 77 Cu based on different a priori assumptions are presented along with comparisons to literature values.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new generation of uranium coincidence fast neutron collars for assay of LWR fresh fuel assemblies

The active uranium neutron coincidence collar provides a means of non-destructively assaying the fissile linear density of Light Water Reactor fresh fuel assemblies containing low enriched uranium. These neutron collars can operate in two modes: a thermal and a fast mode. In fast mode, a neutron collar has an added cadmium (Cd) liner in the sample cavity of the detector to reduce the impact of the burnable poison (thermal neutron absorber) on the detector signal (doubles). The main advantage for operating in fast mode is a detected signal that is less dependent of the burnable neutron poison content and thus less dependent on facility operator declarations. The drawback is that operating in fast mode requires a longer measurement time (~hour vs tens of minutes for thermal mode) to achieve the statistically needed precision in the measurements. The trend in the modern reactor fuel assemblies is moving to higher burnup by using higher initial enrichment and, consequently, a higher number of burnable poison rods to compensate the initial neutron reactivity. The increase of the burnable poison loading has motivated the development of a new generation of high efficiency fast neutron collars to allow practical measurements in-field by nuclear inspectors. This paper describes the development and performance evaluation of a new generation of neutron collars, for both boiling water reactor (BWR) and pressurized water reactor (PWR) fuels, jointly developed between the US Department of Energy, through Los Alamos National Laboratory, and the Euratom Safeguards Directorate of the European Commission. In this work, we present here calibrations with reference fuel assemblies at Los Alamos National Laboratory as well as the results of in-field measurement campaigns in fuel fabrication plants with modern commercial fuel assemblies. The experimental results show that a typical PWR verification can be made in a total time of 30 min with an uncertainty in the measured mass of 2% at one standard deviation (1σ). A BWR verification can be made in 47 min with an uncertainty in the measured mass of 1.9% at 1σ, or a total time of 20 min with 1σ uncertainty in the measured mass of 2.5%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning a time-gated camera for fast neutron beamline spatial-energy characterization at LANSCE-WNR spallation source

An energy-resolved fast neutron beam imaging diagnostic has been successfully commissioned at the Weapons Neutron Research (WNR) spallation source within the Los Alamos Neutron Science Center (LANSCE) facility. This diagnostic replaces the existing analog phosphor image plates, which integrate across all neutron energies, as well as other particles, with a near-real-time energy-sensitive imaging capability. The system uses a fast plastic scintillator coupled with an intensified CCD camera. Specifically, the Teledyne Pi-MAX4 camera is coupled with either a 4 mm thick Eljen (EJ) 204 or 228 plastic scintillator. These scintillators are most sensitive to the fast neutrons (0.8-800 MeV) directly from the spallation source rather than low energy background radiation. Experimentally, these plastic scintillators were shown to have sufficiently fast decay to differentiate the bright gamma flash from the spallation neutrons. The spatial resolution is dominated by neutron beam divergence, with minimal additional contributions from scatter and light divergence. The system successfully resolved changes in neutron beam characteristics caused by intentional proton steering variations. Additionally, simulations of scintillator light yield as a function of thickness conducted using PHITS (with Scinful-QMD package) found that increasing scintillator thickness from 4 mm to 6 or 8 mm could potentially increase brightness ~ 3x. This may be explored if there is a need to reduce image acquisition time from several minutes to under one minute.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Selective thermal neutron transmutation doping with Gd masks in GaN semiconductors

For the first time, selective neutron transmutation doping was successfully performed on GaN through Gd masks, showing the feasibility of patternable doping through neutron irradiations. In collaborating with Oak Ridge National Laboratory, GaN with Gd masks was irradiated by directional neutrons. By using the Gd properties with high neutron absorption cross-sections, it was confirmed that the area covered by Gd masks on GaN was completely shielded from neutrons, and the uncovered area was doped with the generated Ge and 14 C. Property differences were clearly identified in various ways when comparing the area exposed by neutrons and the area unexposed by neutrons. The discoloration by the ejected protons and elastic scattering of neutrons appeared only in the exposed area while the unexposed area remained the same as before irradiation. The aspect ratio of the patterned profile of GaN was estimated by comparing patterns on the front and backside. From energy dispersive X-ray spectroscopy spectra and secondary ion mass spectrometry measurement, the concentration difference between Ge and 14 C as well as the exact concentration of produced 14 C was also checked. Further, Schottky barrier diodes on the selectively doped GaN were fabricated and investigated to study the electrical properties.

42 ENGINEERING↗

Fabrication and characterization of the source grating for visibility improvement of neutron phase imaging with gratings

The fabrication of gratings including metal deposition processes for highly neutron absorbing lines is a critical issue to achieve a good visibility of the grating-based phase imaging system. The source grating for a neutron Talbot-Lau interferometer is an array of Gadolinium (Gd) structures that are generally made by sputtering, photo-lithography, and chemical wet etching. However, it is very challenging to fabricate a Gd structure with sufficient neutron attenuation of approximately more than 20 {mu}m using a conventional metal deposition method because of the slow Gd deposition rate, film stress, high material cost, and so on. In this article, we fabricated the source gratings for neutron Talbot-Lau interferometers by filling the silicon structure with Gadox particles. The new fabrication method allowed us a very stable and efficient way to achieve a much higher Gadox filled structure than a Gd film structure, and is even more suitable for thermal polychromatic neutrons, which are more difficult to stop than cold neutrons. The newly fabricated source gratings were tested at the polychromatic thermal neutron grating interferometer system of HANARO at the Korea Atomic Energy Research Institute, and the visibilities and images from the neutron phase imaging system with the new source gratings were compared with those fabricated by a Gd deposition method.

36 MATERIALS SCIENCE↗

Phillips-Tikhonov regularization with a priori information for neutron emission tomographic reconstruction on Joint European Torus

A method of tomographic reconstruction of the neutron emissivity in the poloidal cross section of the Joint European Torus (JET, Culham, UK) tokamak was developed. Due to very limited data set (two projection angles, 19 lines of sight only) provided by the neutron emission profile monitor (KN3 neutron camera), the reconstruction is an ill-posed inverse problem. The aim of this work consists in making a contribution to the development of reliable plasma tomography reconstruction methods that could be routinely used at JET tokamak. The proposed method is based on Phillips-Tikhonov regularization and incorporates a priori knowledge of the shape of normalized neutron emissivity profile. For the purpose of the optimal selection of the regularization parameters, the shape of normalized neutron emissivity profile is approximated by the shape of normalized electron density profile measured by LIDAR or high resolution Thomson scattering JET diagnostics. In contrast with some previously developed methods of ill-posed plasma tomography reconstruction problem, the developed algorithms do not include any post-processing of the obtained solution and the physical constrains on the solution are imposed during the regularization process. The accuracy of the method is at first evaluated by several tests with synthetic data based on various plasma neutron emissivity models (phantoms). Then, the method is applied to the neutron emissivity reconstruction for JET D plasma discharge #85100. It is demonstrated that this method shows good performance and reliability and it can be routinely used for plasma neutron emissivity reconstruction on JET.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the radial neutron camera system for the HL-2A tokamak

A new radial neutron camera system has been developed and operated recently in the HL-2A tokamak to measure the spatial and time resolved 2.5 MeV D-D fusion neutron, enhancing the understanding of the energetic-ion physics. The camera mainly consists of a multichannel collimator, liquid-scintillation detectors, shielding systems, and a data acquisition system. Measurements of the D-D fusion neutrons using the camera have been successfully performed during the 2015 HL-2A experiment campaign. The measurements show that the distribution of the fusion neutrons in the HL-2A plasma has a peaked profile, suggesting that the neutral beam injection beam ions in the plasma have a peaked distribution. It also suggests that the neutrons are primarily produced from beam-target reactions in the plasma core region. The measurement results from the neutron camera are well consistent with the results of both a standard {sup 235}U fission chamber and NUBEAM neutron calculations. In this paper, the new radial neutron camera system on HL-2A and the first experimental results are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development and characterization of a high yield transportable pulsed neutron source with efficient and compact pulsed power system

The results of characterization experiments carried out on a newly developed dense plasma focus device based intense pulsed neutron source with efficient and compact pulsed power system are reported. Its high current sealed pseudospark switch based low inductance capacitor bank with maximum stored energy of ∼10 kJ is segregated into four modules of ∼2.5 kJ each and it cumulatively delivers peak current in the range of 400 kA–600 kA (corresponding to charging voltage range of 14 kV–18 kV) in a quarter time period of ∼2 μs. The neutron yield performance of this device has been optimized by discretely varying deuterium filling gas pressure in the range of 6 mbar–11 mbar at ∼17 kV/550 kA discharge. At ∼7 kJ/8.5 mbar operation, the average neutron yield has been measured to be in the order of ∼4 × 10{sup 9} neutrons/pulse which is the highest ever reported neutron yield from a plasma focus device with the same stored energy. The average forward to radial anisotropy in neutron yield is found to be ∼2. The entire system is contained on a moveable trolley having dimensions 1.5 m × 1 m × 0.7 m and its operation and control (up to the distance of 25 m) are facilitated through optically isolated handheld remote console. The overall compactness of this system provides minimum proximity to small as well as large samples for irradiation. The major intended application objective of this high neutron yield dense plasma focus device development is to explore the feasibility of active neutron interrogation experiments by utilization of intense pulsed neutron sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated edge-to-exascale workflow for real-time steering in neutron scattering experiments

We introduce a computational framework that integrates artificial intelligence (AI), machine learning, and high-performance computing to enable real-time steering of neutron scattering experiments using an edge-to-exascale workflow. Focusing on time-of-flight neutron event data at the Spallation Neutron Source, our approach combines temporal processing of four-dimensional neutron event data with predictive modeling for multidimensional crystallography. At the core of this workflow is the Temporal Fusion Transformer model, which provides voxel-level precision in predicting 3D neutron scattering patterns. The system incorporates edge computing for rapid data preprocessing and exascale computing via the Frontier supercomputer for large-scale AI model training, enabling adaptive, data-driven decisions during experiments. This framework optimizes neutron beam time, improves experimental accuracy, and lays the foundation for automation in neutron scattering. Although real-time experiment steering is still in the proof-of-concept stage, the demonstrated potential of this system offers a substantial reduction in data processing time from hours to minutes via distributed training, and significant improvements in model accuracy, setting the stage for widespread adoption across neutron scattering facilities and more efficient exploration of complex material systems.

97 MATHEMATICS AND COMPUTING↗

An Analytic Benchmark for Neutron Boltzmann Transport with Downscattering—Part I: Flux and Eigenvalue Solutions

Computing in the energy dimension is one of the greatest challenges confronting present-day deterministic neutron transport solvers. Accurately resolving the neutron flux as neutrons downscatter across resonances in the nuclear cross sections currently requires considerable computing power and suffers from approximation errors. Flux uncertainty resulting from the uncertainty of the resonance structure is the single-largest cause of reactivity uncertainty. Any additional reference solution for the critical neutron downscattering problem with resonance phenomena would be a boon to verification and validation of neutronics codes. This paper establishes a benchmark to verify the accuracy of neutron transport criticality solvers along the energy dimension. For the first time, the analytic solution of the flux amplitude is derived in the particular case of an infinite homogeneous medium with isotropic scattering in the center of mass and an arbitrary number of no-threshold, neutral particle reaction resonances (e.g., radiative capture, fission, and resonance scattering). Furthermore, original analytic expressions are established to quantify the discrepancy between the ψ k (E) and ψ α (E) flux amplitudes, respective solutions of the multiplication factor k, or the exponential time-evolution frequency α eigenproblems. The physical study of these relations led to analysis of their first-order relative difference near the criticality condition α=0. Finally, numerical solutions are provided to a benchmark problem constituted of the first resonance of 239 Pu, the 6.67-eV resonance of 238 U, and a scattering isotope with a flat cross section, allowing for the computational verification of the energy resolution of current neutron transport criticality codes. Through these novel results, this analytic benchmark can serve as a reference to verify the energy resolution and sensitivity analysis of neutron transport criticality calculations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

NEUTRINO EMISSION FROM COOPER PAIRS AND MINIMAL COOLING OF NEUTRON STARS

The minimal cooling paradigm for neutron star cooling assumes that enhanced cooling due to neutrino emission from any direct Urca process, due either to nucleons or to exotica such as hyperons, Bose condensates, or deconfined quarks, does not occur. Previous studies showed that the observed temperatures of young, cooling, isolated neutron stars with ages between 10{sup 2} and 10{sup 5} yr, with the possible exception of the pulsar in the supernova remnant CTA 1, are consistent with predictions of the minimal cooling paradigm as long as the neutron {sup 3} P{sub 2} pairing gap present in the stellar core is of moderate size. Recently, it has been found that Cooper-pair neutrino emission from the vector channel is suppressed by a large factor, of the order of 10{sup -3}, compared to the original estimates that violated vector current conservation. We show that Cooper-pair neutrino emission remains, nevertheless, an efficient cooling mechanism through the axial channel. As a result, the elimination of neutrino emission from Cooper-paired nucleons through the vector channel has only minor effects on the long-term cooling of neutron stars within the minimal cooling paradigm. We further quantify precisely the effect of the size of the neutron {sup 3} P{sub 2} gap and demonstrate that consistency between observations and the minimal cooling paradigm requires that the critical temperature T{sub c} for this gap covers a range of values between T {sup min}{sub c} approx< 0.2 x 10{sup 9} up to T {sup max}{sub c} approx> 0.5 x 10{sup 9} in the core of the star. This range of values guarantees that the Cooper-pair neutrino emission is operating efficiently in stars with ages between 10{sup 3} to 10{sup 5} yr, leading to the coldest predicted temperatures for young neutron stars. In addition, it is required that young neutron stars have heterogeneous envelope compositions: some must have light-element compositions and others must have heavy-element compositions. Unless these two conditions are fulfilled, about half of the observed young cooling neutron stars are inconsistent with the minimal cooling paradigm and provide evidence for the existence of enhanced cooling.

79 ASTRONOMY AND ASTROPHYSICS↗

Prospects for measuring neutron-star masses and radii with X-ray pulse profile modeling

Modeling the amplitudes and shapes of the X-ray pulsations observed from hot, rotating neutron stars provides a direct method for measuring neutron-star properties. This technique constitutes an important part of the science case for the forthcoming NICER and proposed LOFT X-ray missions. In this paper, we determine the number of distinct observables that can be derived from pulse profile modeling and show that using only bolometric pulse profiles is insufficient for breaking the degeneracy between inferred neutron-star radius and mass. However, we also show that for moderately spinning (300-800 Hz) neutron stars, analysis of pulse profiles in two different energy bands provides additional constraints that allow a unique determination of the neutron-star properties. Using the fractional amplitudes of the fundamental and the second harmonic of the pulse profile in addition to the amplitude and phase difference of the spectral color oscillations, we quantify the signal-to-noise ratio necessary to achieve a specified measurement precision for neutron star radius. We find that accumulating 10{sup 6} counts in a pulse profile is sufficient to achieve a ≲ 5% uncertainty in the neutron star radius, which is the level of accuracy required to determine the equation of state of neutron-star matter. Finally, we formally derive the background limits that can be tolerated in the measurements of the various pulsation amplitudes as a function of the system parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Deuterium Depth Profile in Neutron-Irradiated Tungsten Exposed to Plasma

The effect of radiation damage has been mainly simulated using high-energy ion bombardment. The ions, however, are limited in range to only a few microns into the surface. Hence, some uncertainty remains about the increase of trapping at radiation damage produced by 14 MeV fusion neutrons, which penetrate much farther into the bulk material. With the Japan-US joint research project: Tritium, Irradiations, and Thermofluids for America and Nippon (TITAN), the tungsten samples (99.99 % pure from A.L.M.T., 6mm in diameter, 0.2mm in thickness) were irradiated to high flux neutrons at 50 C and to 0.025 dpa in the High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory (ORNL). Subsequently, the neutron-irradiated tungsten samples were exposed to a high-flux deuterium plasma (ion flux: 1021-1022 m-2s-1, ion fluence: 1025-1026 m-2) in the Tritium Plasma Experiment (TPE) at the Idaho National Laboratory (INL). First results of deuterium retention in neutron-irradiated tungsten exposed in TPE have been reported previously. This paper presents the latest results in our on-going work of deuterium depth profiling in neutron-irradiated tungsten via nuclear reaction analysis. The experimental data is compared with the result from non neutron-irradiated tungsten, and is analyzed with the Tritium Migration Analysis Program (TMAP) to elucidate the hydrogen isotope behavior such as retention and depth distribution in neutron-irradiated and non neutron-irradiated tungsten.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

Neutron Science TeraGrid Gateway

The unique contributions of the Neutron Science TeraGrid Gateway (NSTG) are the connection of national user facility instrument data sources to the integrated cyberinfrastructure of the National Science FoundationTeraGrid and the development of a neutron science gateway that allows neutron scientists to use TeraGrid resources to analyze their data, including comparison of experiment with simulation. The NSTG is working in close collaboration with the Spallation Neutron Source (SNS) at Oak Ridge as their principal facility partner. The SNS is a next-generation neutron source. It has completed construction at a cost of $1.4 billion and is ramping up operations. The SNS will provide an order of magnitude greater flux than any previous facility in the world and will be available to all of the nation's scientists, independent of funding source, on a peer-reviewed merit basis. With this new capability, the neutron science community is facing orders of magnitude larger data sets and is at a critical point for data analysis and simulation. There is a recognized need for new ways to manage and analyze data to optimize both beam time and scientific output. The TeraGrid is providing new capabilities in the gateway for simulations using McStas and a fitting service on distributed TeraGrid resources to improved turnaround. NSTG staff are also exploring replicating experimental data in archival storage. As part of the SNS partnership, the NSTG provides access to gateway support, cyberinfrastructure outreach, community development, and user support for the neutron science community. This community includes not only SNS staff and users but extends to all the major worldwide neutron scattering centers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

First full Dalitz plot measurement in neutron 𝛽 decay using the Nab spectrometer and implications for new physics

Precision measurements of observables in neutron 𝛽 decay are used to test the standard model description of the weak interaction and search for evidence of new physics. The Nab experiment at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was constructed to measure correlations in neutron decay by utilizing an asymmetric spectrometer and novel detection system to accurately reconstruct the proton momentum and electron energy for each 𝛽 decay. This work describes the detection of neutron 𝛽-decay products in the Nab spectrometer and presents the first full Dalitz plot representation of the phase space of neutron 𝛽 decay for all electrons >100 keV. In addition, new constraints are placed on a possible excited neutron state, hypothesized to explain the disagreement between the appearance and disappearance neutron lifetime techniques.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Relativistic mean-field theories for neutron-star physics based on chiral effective field theory

We describe and implement a procedure for determining the couplings of a relativistic mean-field theory (RMFT) that is optimized for application to neutron star phenomenology. In the standard RMFT approach, the couplings are constrained by comparing the theory's predictions for symmetric matter at saturation density with measured nuclear properties. The theory is then applied to neutron stars which consist of neutron-rich matter at densities ranging up to several times saturation density, which allows for additional astrophysical constraints. In our approach, rather than using the RMFT to extrapolate from symmetric to neutron-rich matter and from finite-sized nuclei to uniform matter, we fit the RMFT to properties of uniform pure neutron matter obtained from chiral effective field theory. Chiral effective field theory incorporates the experimental data for nuclei in the framework of a controlled expansion for nuclear forces valid at nuclear densities and enables us to account for theoretical uncertainties when fitting the RMFT. We construct four simple RMFTs that span the uncertainties provided by chiral effective field theory for neutron matter, and are consistent with current astrophysical constraints on the equation of state. Lastly, our RMFTs can be used to model the properties of neutron-rich matter across the vast range of densities and temperatures encountered in neutron stars and their mergers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Information Content of a New Observable: The Case of the Nuclear Neutron Skin

The radius of the neutron distribution of a heavy nucleus is related to the equation of state for neutron matter that determines properties of nuclei and neutron stars. By systematically varying coupling constants characterizing the nuclear energy density functional and studying the resulting confidence ellipsoid, we quantify the relationships between the neutron skin and various properties of finite nuclei and infinite nuclear matter. According to the covariance analysis, the neutron skin is strongly correlated with the dipole polarizability and symmetry energy, and is very weakly correlated with the low-energy electric dipole strength. By adding the information on the neutron radius to the pool of observables determining the energy functional, we show how precise experimental determination of the neutron radius in ^{208}Pb would reduce theoretical uncertainties on the neutron matter equation of state.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗