Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Modal Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The Transit-Time Distribution from the Northern Hemisphere Midlatitude Surface

The distribution of transit times from the Northern Hemisphere (NH) midlatitude surface is a fundamental property of tropospheric transport. Here we present an analysis of the transit time distribution (TTD) since air last contacted the northern midlatitude surface layer, as simulated by the NASA Global Modeling Initiative Chemistry Transport Model. We find that throughout the troposphere the TTD is characterized by long flat tails that reflect the recirculation of old air from the Southern Hemisphere and results in mean ages that are significantly larger than the modal age. Key aspects of the TTD -- its mode, mean and spectral width -- are interpreted in terms of tropospheric dynamics, including seasonal shifts in the location and strength of tropical convection and variations in quasi-isentropic transport out of the northern midlatitude surface layer. Our results indicate that current diagnostics of tropospheric transport are insufficient for comparing model transport and that the full distribution of transit times is a more appropriate constraint.

model transport↗

CAMFeND: Credibility-Aware Multimodal Fake News Detection with Rotational Attention

In the evolving digital landscape, fake news is a significant challenge, influencing public perception and decision-making. Traditional detection approaches focus on single-modal data or simple multimodal fusion, often overlooking deeper interactions and news credibility. We propose a novel model addressing these limitations by introducing rotational attention and news domain information as a feature. Unlike static attention mechanisms, our rotational attention dynamically shifts query, key, and value roles across text and image inputs, enabling richer cross-modal interaction. Incorporating news domain information further enhances the model’s reliability by associating news posts with top domains extracted from Google search results, reducing false detections. This approach assesses both the content and the broader web context in which the news is discussed. Our model outperforms existing state-of-the-art methods by providing deeper, layered multimodal integration and domain information analysis, resulting in a more robust and adaptive fake news detection system.

Gupta, Nidhi↗

Finite-element analysis of vibration and flutter of cantilever anisotropic plates

The hybrid stress finite element method is used to study the effects of filament angle and orthotropicity parameter on the vibration and flutter characteristics of cantilevered anisotropic plates. The results indicate a generally strong lack of monotonic dependence on filament angle. Also, the natural frequency in certain cases involving the first few modes, can become relatively insensitive to both filament angle and orthotropicity parameter for a range of filament angle beyond 70 deg. Values of critical dynamic pressure are obtained by a modal approach, in which the mode shapes are obtained by the hybrid stress method. Convergence of the modal method is rather rapid for the configurations analyzed, and a comparison of the method with an exact solution for the case of an isotropic simply supported plate shows that use of six modes gives excellent agreement.

Rossettos, J. N.↗

TH-AB-209-07: High Resolution X-Ray-Induced Acoustic Computed Tomography

Purpose: X-ray radiographic absorption imaging is an invaluable tool in medical diagnostics, biology and materials science. However, the use of conventional CT is limited by two factors: the detection sensitivity to weak absorption material and the radiation dose from CT scanning. The purpose of this study is to explore X-ray induced acoustic computed tomography (XACT), a new imaging modality, which combines X-ray absorption contrast and high ultrasonic resolution to address these challenges. Methods: First, theoretical models was built to analyze the XACT sensitivity to X-ray absorption and calculate the minimal radiation dose in XACT imaging. Then, an XACT system comprised of an ultrashort X-ray pulse, a low noise ultrasound detector and a signal acquisition system was built to evaluate the X-ray induced acoustic signal generation. A piece of chicken bone and a phantom with two golden fiducial markers were exposed to 270 kVp X-ray source with 60 ns exposure time, and the X-ray induced acoustic signal was received by a 2.25MHz ultrasound transducer in 200 positions. XACT images were reconstructed by a filtered back-projection algorithm. Results: The theoretical analysis shows that X-ray induced acoustic signals have 100% relative sensitivity to X-ray absorption, but not to X-ray scattering. Applying this innovative technology to breast imaging, we can reduce radiation dose by a factor of 50 compared with newly FDA approved breast CT. The reconstructed images of chicken bone and golden fiducial marker phantom reveal that the spatial resolution of the built XACT system is 350µm. Conclusion: In XACT, the imaging sensitivity to X-ray absorption is improved and the imaging dose is dramatically reduced by using ultrashort pulsed X-ray. Taking advantage of the high ultrasonic resolution, we can also perform 3D imaging with a single X-ray pulse. This new modality has the potential to revolutionize x-ray imaging applications in medicine and biology.

60 APPLIED LIFE SCIENCES↗

Advances in Multimodal Characterization of Structural Materials

The myriad detectors and instruments now available for materials characterization provide researchers with an ever-growing suite of tools to probe material behavior. Progress in the development of instrumentation and workflows that enable the collection, and leverage the potential, of various data modalities have provided novel insights into material behavior. Using data across multiple length scales, or performing complementary analyses of in situ and ex situ data, can help reveal a more complete picture of dynamic processes or material structure. However, the accurate combination, or fusion, of these disparate data modalities presents new challenges. Differences in resolution, as well as the varying length scales at which physical phenomena are exploited to generate these data, necessitate novel approaches to accurately interpret and combine these data. Furthermore, the papers within this special topic focus on the collection and fusion of multimodal data to better understand structural materials. From new frameworks and workflows for data segmentation and analysis, process monitoring, enhancing simulations, or interrogating mechanical response, these papers reveal the potential benefits of utilizing multimodal data.

36 MATERIALS SCIENCE↗

Robotic Image-Guided Stereotactic Radiotherapy, for Isolated Recurrent Primary, Lymph Node or Metastatic Prostate Cancer

Purpose: To evaluate the outcome of robotic CyberKnife (Accuray, Sunnyvale, CA)-based stereotactic radiotherapy (CBK-SRT) for isolated recurrent primary, lymph node, or metastatic prostate cancer. Methods and Materials: Between May 2007 and December 2009, 34 consecutive patients/38 lesions were treated (15 patients reirradiated for local recurrence [P], 4 patients reirradiated for anastomosis recurrence [A], 16 patients treated for single lymph node recurrence [LN], and 3 patients treated for single metastasis [M]). In all but 4 patients, [{sup 11}C]choline positron emission tomography/computed tomography was performed. CBK-SRT consisted of reirradiation and first radiotherapy in 27 and 11 lesions, respectively. The median CBK-SRT dose was 30 Gy in 4.5 fractions (P, 30 Gy in 5 fractions; A, 30 Gy in 5 fractions; LN, 33 Gy in 3 fractions; and M, 36 Gy in 3 fractions). In 18 patients (21 lesions) androgen deprivation was added to CBK-SRT (median duration, 16.6 months). Results: The median follow-up was 16.9 months. Acute toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event). Late toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event and 1 Grade 2 event). Biochemical response was observed in 32 of 38 evaluable lesions. Prostate-specific antigen stabilization was seen for 4 lesions, and in 2 cases prostate-specific antigen progression was reported. The 30-month progression-free survival rate was 42.6%. Disease progression was observed for 14 lesions (5, 2, 5, and 2 in Groups P, A, LN, and M respectively). In only 3 cases, in-field progression was seen. At the time of analysis (May 2010), 19 patients are alive with no evidence of disease and 15 are alive with disease. Conclusions: CyberKnife-based stereotactic radiotherapy is a feasible approach for isolated recurrent primary, lymph node, or metastatic prostate cancer, offering excellent in-field tumor control and a low toxicity profile. Further investigation is warranted to identify the patients who benefit most from this treatment modality. The optimal combination with androgen deprivation should also be defined.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-J-51: A Cone-Based Scintillator Detector for IGRT QA for Scattered and Scanning Proton Therapy

Purpose: IGRT commissioning and QA are critical components for precise delivery of proton treatment beams to patients. In order to ensure high quality IGRT, a new cone-based scintillator detector was evaluated for our QA activities for double-scattered and scanning proton modalities. This allows a routine evaluation of the gantry-angle dependent position offset between the radiation and imaging. Methods: The cone-based scintillator detector (XRV-124, Logos Systems, Int’l CA, USA) features a unique configuration of measuring stereotactic paths of proton and x-ray beams in a single setup with arbitrary gantry angles. For the beams-eye-view (BEV) analysis of x-ray crosshair images, a cylindrical representation of the cone image was newly developed. The calibration accuracy was evaluated using different CT resolutions for a range of 55 – 95mm in patient’s cranial direction and ±9mm in the lateral direction. Energy-dependent spot sizes (σ) of pencil beams were characterized and compared to measurements by the MatriXX detector (IBA, Germany). Iso-centric deviations between radiation and x-ray imaging were characterized as a function of gantry angle. Results: The position calibration of the detector was successfully verified with a reproducible positioning by x-ray imaging. The measurements were reproducible within clinical tolerances (±1mm). The spot size vs. energy at zero gantry angle measured with the scintillating cone detector agreed with the MatriXX detector measurements within 17%. Conclusion: The new approach to investigate the accuracy of IGRT and pencil beam properties could successfully be implemented into the QA program. The system will improve efficiency in our QA activities for proton treatments.

60 APPLIED LIFE SCIENCES↗

Microbial Community Analysis & Functional Evaluation in Soils

The overall objective of this proposal was to develop technologies to alter the composition and function of important members of microbial communities. In particular, the overall objective of the microbial community editing portion of the proposal focuses on developing foundational tools and understanding required to predict, alter and design grass rhizosphere communities impacting DOE missions. Specifically, the project is centered on the Microbial Community Analysis & Functional Evaluation in Soils (m-CAFES) to manipulate microbial consortia associated with plants of interest for the bioenergy sector, under the presumption that bacterial communities can be manipulated to enhance plant health. For tasks of specific interest to us, we are focusing on developing novel Clustered Regularly Interspaced Short Palindromic Repeats (CRISPR) based technologies (primarily focusing on Aim 1) and their delivery modalities (notably subaim 1.2) to edit specific bacterial genomes of interest to enhance their functionalities, and programmably ablate specific undesirable members of bacterial communities for plant health. We are focusing on engineering bacteriophages (bacterial viruses, for subaim 1.2) to carry programmable CRISPR-Cas systems (subaim 1.1) to target (ablate) or alter (edit) genomes of interest. This will enable us to carry out microbial perturbations that will impact community composition and function and ultimately plant growth and health, to enable the next phase of the project by deploying them in situ (subaims 1.3 and 1.4).

59 BASIC BIOLOGICAL SCIENCES↗

Some instrumentation requirement issues for the Space Station structural characterization experiment

The Space Station will provide unique opportunities to the research and technology community as a national in-space research facility. Opportunities will exist for technology experiments in a variety of disciplines, including dynamics and control of large space structures (LSS). The Space Station Structural Characterization Experiment (SSSCE) is an early space station technology experiment now under development. The objective of the experiment is to instrument and use the Space Station as a generic research test article, in support of research and technology activities in the areas of structural dynamics and control/structure interaction (CSI). Tests will be conducted, potentially, on each assembly flight configuration, as well as on the phase 1 configuration. Structural dynamic response data will be measured and transferred to the ground for analysis. These measurements will support the development and in-space verification of system identification and analytical modeling techniques for future LSS, including the evolutionary Space Station. The paper begins by restating the principal objective of SSSCE, along with the basic approach that will be used. The body of the paper deals with instrumentation requirement issues. The paper closes with several questions concerning modal-testing objectives and limitations, a brief review of a previous on-orbit experiment, the Solar Array Flight Experiment, and concluding remarks.

Pappa, Richard S.↗

Operating Deflection Shapes for the Space Shuttle Partial Stack Rollout

In November of 2003 a rollout test was performed to gain a better understanding of the dynamic environment for the Space Shuttle during transportation from the Vehicle Assembly Building to the launch pad. This was part of a study evaluating the methodology for including the rollout dynamic loads in the Space Shuttle fatigue life predictions. The rollout test was conducted with a partial stack consisting of the Crawler Transporter, Mobile Launch Platform, and the Solid Rocket Boosters with an interconnecting crossbeam. Instrumentation included over 100 accelerometers. Data was recorded for steady state speeds, start-ups and stops, and ambient wind excitations with the vehicle at idle. This paper will describe the operating deflection shape analysis performed using the measured acceleration response data. The response data for the steady state speed runs were dominated by harmonics of the forcing frequencies, which were proportional to the vehicle speed. Assuming a broadband excitation for the wind, analyses of the data sets with the vehicle at idle were used to estimate the natural frequencies and corresponding mode shapes. Comparisons of the measured modal properties with numerical predictions are presented.

Buehrle, Ralph D.↗

Advanced Multimodal Solutions for Information Presentation

High-workload, fast-paced, and degraded sensory environments are the likeliest candidates to benefit from multimodal information presentation. For example, during EVA (Extra-Vehicular Activity) and telerobotic operations, the sensory restrictions associated with a space environment provide a major challenge to maintaining the situation awareness (SA) required for safe operations. Multimodal displays hold promise to enhance situation awareness and task performance by utilizing different sensory modalities and maximizing their effectiveness based on appropriate interaction between modalities. During EVA, the visual and auditory channels are likely to be the most utilized with tasks such as monitoring the visual environment, attending visual and auditory displays, and maintaining multichannel auditory communications. Previous studies have shown that compared to unimodal displays (spatial auditory or 2D visual), bimodal presentation of information can improve operator performance during simulated extravehicular activity on planetary surfaces for tasks as diverse as orientation, localization or docking, particularly when the visual environment is degraded or workload is increased. Tactile displays offer a third sensory channel that may both offload information processing effort and provide a means to capture attention when urgently required. For example, recent studies suggest that including tactile cues may result in increased orientation and alerting accuracy, improved task response time and decreased workload, as well as provide self-orientation cues in microgravity on the ISS (International Space Station). An important overall issue is that context-dependent factors like task complexity, sensory degradation, peripersonal vs. extrapersonal space operations, workload, experience level, and operator fatigue tend to vary greatly in complex real-world environments and it will be difficult to design a multimodal interface that performs well under all conditions. As a possible solution, adaptive systems have been proposed in which the information presented to the user changes as a function of taskcontext-dependent factors. However, this presupposes that adequate methods for detecting andor predicting such factors are developed. Further, research in adaptive systems for aviation suggests that they can sometimes serve to increase workload and reduce situational awareness. It will be critical to develop multimodal display guidelines that include consideration of smart systems that can select the best display method for a particular contextsituation.The scope of the current work is an analysis of potential multimodal display technologies for long duration missions and, in particular, will focus on their potential role in EVA activities. The review will address multimodal (combined visual, auditory andor tactile) displays investigated by NASA, industry, and DoD (Dept. of Defense). It also considers the need for adaptive information systems to accommodate a variety of operational contexts such as crew status (e.g., fatigue, workload level) and task environment (e.g., EVA, habitat, rover, spacecraft). Current approaches to guidelines and best practices for combining modalities for the most effective information displays are also reviewed. Potential issues in developing interface guidelines for the Exploration Information System (EIS) are briefly considered.

multimodal display↗

A General Framework for Monitoring Image Acquisition Workflow in the Radiology Environment: Timeliness for Acute Stroke CT Imaging

Many facets of an image acquisition workflow leave a digital footprint, making workflow analysis amenable to an informatics-based solution. This paper describes a detailed framework for analyzing workflow and uses acute stroke response timeliness in CT as a practical demonstration. We review methods for accessing the digital footprints resulting from common technologist/device interactions. This overview lays a foundation for obtaining data for workflow analysis. We demonstrate the method by analyzing CT imaging efficiency in the setting of acute stroke. We successfully used digital footprints of CT technologists to analyze their workflow. We presented an overview of other digital footprints including but not limited to contrast administration, patient positioning, billing, reformat creation, and scheduling. A framework for analyzing image acquisition workflow was presented. This framework is transferable to any modality, as the key steps of image acquisition, image reconstruction, image post processing, and image transfer to PACS are common to any imaging modality in diagnostic radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

In vivo measurement of mechanical properties of human long bone by using sonic sound

Vibration analysis has evaluated as non-invasive techniques for the in vivo assessment of bone mechanical properties. The relation between the resonant frequencies, long bone geometry and mechanical properties can be obtained by vibration analysis. In vivo measurements were performed on human ulna as a simple beam model with an experimental technique and associated apparatus. The resonant frequency of the ulna was obtained by Fast Fourier Transformation (FFT) analysis of the vibration response of piezoelectric accelerometer. Both elastic modulus and speed of the sound were inferred from the resonant frequency. Measurement error in the improved experimental setup was comparable with the previous work. The in vivo determination of bone elastic response has potential value in screening programs for metabolic bone disease, early detection of osteoporosis and evaluation of skeletal effects of various therapeutic modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Determination of optical parameters of atmospheric particulates from ground-based polarimeter measurements

This paper describes the theoretical analysis that is required to infer, from polarimeter measurements of skylight, the size distribution, refractive index and abundance of particulates in the atmosphere. To illustrate the viability of the method, some data obtained at UCLA is analyzed and the atmospheric parameters are derived. The explicit demonstration of the redundancy in the description of aerosol distributions suggests that radiation field measurements will not uniquely determine the modal radius of the size distribution. In spite of this nonuniqueness information useful to heat budget calculations can be derived.

Kuriyan, J. G.↗

On the use of the consistent mass matrix in flexible multibody systems

Two different methods are used in finite element structural analysis to define element mass distribution: consistent and lumped mass approximations. The lumped mass method is currently favored in multibody dynamics software packages because of its computational efficiency. This paper, however, presents a multibody dynamics formulation based on the consistent mass approach which should prove to be as computationally efficient as the lumped mass approach. It is shown that when component flexibility is modelled using modal coordinates, the equations of motion, as formulated by these two methods, are very similar in appearance, thereby facilitating their comparison. It is also shown, through simulation of a simple multibody system, that a system formulated with the lumped mass approximation will often require more finite elements and smaller integration step sizes than the corresponding consistent mass system.

Anthony, Tobin C.↗

Comparison of Predicted and Measured Attenuation of Turbine Noise from a Static Engine Test

Aircraft noise has become an increasing concern for commercial airlines. Worldwide demand for quieter aircraft is increasing, making the prediction of engine noise suppression one of the most important fields of research. The Low-Pressure Turbine (LPT) can be an important noise source during the approach condition for commercial aircraft. The National Aeronautics and Space Administration (NASA), Pratt & Whitney (P&W), and Goodrich Aerostructures (Goodrich) conducted a joint program to validate a method for predicting turbine noise attenuation. The method includes noise-source estimation, acoustic treatment impedance prediction, and in-duct noise propagation analysis. Two noise propagation prediction codes, Eversman Finite Element Method (FEM) code [1] and the CDUCT-LaRC [2] code, were used in this study to compare the predicted and the measured turbine noise attenuation from a static engine test. In this paper, the test setup, test configurations and test results are detailed in Section II. A description of the input parameters, including estimated noise modal content (in terms of acoustic potential), and acoustic treatment impedance values are provided in Section III. The prediction-to-test correlation study results are illustrated and discussed in Section IV and V for the FEM and the CDUCT-LaRC codes, respectively, and a summary of the results is presented in Section VI.

Chien, Eugene W.↗

The Effects of Fiber Orientation and Adhesives on Tensile Properties of Carbon Fiber Reinforced Polymer Matrix Composite with Embedded Nickel-Titanium Shape Memory Alloys

Tensile tests of Nickel-titanium (NiTi) shape memory alloys (SMA) embedded within carbon fiber reinforced polymer matrix composite (CFRP/PMC) laminates were evaluated with simultaneous monitoring of modal acoustic emissions (MAE). Three different layup configurations utilizing two different thin film adhesives were applied to bond the materials. Ultimate tensile strengths, strains, and moduli were obtained along with cumulative AE energy of events and specimen failure location. Scanning electron microscopy was used to examine the break areas of the specimens post-test. Microscopy was used to validate failure locations revealed from MAE analysis. A unique finding within this research showed that 90° plies in the outer ply gave the strongest acoustic signals as well as the cleanest fracture of the specimens tested. Overlapping 0° ply layers surrounding the SMA was found to be the best scenario to prevent failure of the specimen itself.

Derek Quade↗

Identifying Sample Provenance From SEM/EDS Automated Particle Analysis via Few-Shot Learning Coupled With Similarity Graph Clustering

Automated particle analysis (APA) provides a vast amount of compositional data via energy-dispersive X-ray spectroscopy along with size and shape data via scanning electron microscopy for individual particles in a sample. In many instances, APA data are leveraged to support identification of the source of a sample based on the detection of particles of a specific composition. Often, the particles that provide context make up a minuscule portion of the sample. Additionally, the interpretation of complex samples can be difficult due to the diversity of compositions both in the mixture and within a particle. In this work, we demonstrate a method to compute and cluster similarity graphs that describe inter-particle relationships within a sample using a multi-modal few-shot learning neural network. Here, as a proof-of-concept, we show that samples known to have been exposed to gunshot residue can be distinguished from samples occasionally mistaken for gunshot residue. Our workflow builds upon standard APA techniques and data processing methods to unveil additional information in a readily interpretable and quantitatively comparable format.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗