Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Material Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Compression-after-impact testing of thin composite materials

A new method has been devised to test composite specimens as thin as 8 plies and up to 7.6 cm in width for compression strength. This method utilizes a fixture incorporating the best features of the Celanese and IITRI fixtures combined with an antibuckling jig developed at the University of Dayton Research Institute. This new method uses up to 83 percent less material than the most commonly used compression-after-impact technique (which calls for a 48 ply test specimen) and can also be performed on smaller loading frames since a much smaller force is needed to fail the specimen. The thickness of the test specimen can be fabricated to exactly match production part thickness, thus yielding more meaningful results. CAI tests were performed on IM6/3501 carbon/epoxy utilizing this new method. To verify the design, a series of tests were performed in which undamaged specimens were tested using the new fixture and ASTM D 3410-87 (Celanese compression test) and the results compared. The new fixture works well and will be a valuable asset to MSFC's damage tolerance program.

Nettles, Alan T.↗

Full-scale aircraft cabin flammability tests of improved fire-resistant materials

Full-scale aircraft cabin flammability tests to evaluate the effectiveness of new fire-resistant materials by comparing their burning characteristics with those of older aircraft materials are described. Three tests were conducted and are detailed. Test 1, using pre-1968 materials, was run to correlate the procedures and to compare the results with previous tests by other organizations. Test 2 included newer, improved fire-resistant materials. Test 3 was essentially a duplicate of test 2, but a smokeless fuel was used. Test objectives, methods, materials, and results are presented and discussed. Results indicate that the pre-1968 materials ignited easily, allowed the fire to spread, produced large amounts of smoke and toxic combustion products, and resulted in a flash fire and major fire damage. The newer fire-resistant materials did not allow the fire to spread. Furthermore, they produced less, lower concentrations of toxic combustion products, and lower temperatures. The newer materials did not produce a flash fire.

Stuckey, R. N.↗

Double Cantilever Beam and End Notched Flexure Fracture Toughness Testing of Two Composite Materials

Two different unidirectional composite materials were provided by NASA Langley Research Center and tested by the Composite Materials Research Group within the Department of Mechanical Engineering at the University of Wyoming. Double cantilever beam and end notched flexure tests were performed to measure the mode I (crack opening) and mode II (sliding or shear) interlaminar fracture toughness of the two materials. The two composites consisted of IM7 carbon fiber combined with either RP46 resin toughened with special formulation of LaRC IA resin, known as JJS1356; or PES chain extended thermoplastic resin known as JJS1361. Double Cantilever Beam Specimen Configuration and Test Methods As received from NASA, the test specimens were nominally 0.5 inch wide, 6 inches long, and 0.2 inch thick. A 1 inch long Kapton insert at the midplane of one end of the specimen (placed during laminate fabrication) facilitated crack initiation and extension. It was noted that the specimens provided were smaller than the nominal 1.5 inch wide, 9.0 inch long configuration specified. Similarly, the Kapton inserts were of greater length than those in the present specimens. Hence, the data below should not be compared directly to those generated with the referenced methods. No preconditioning was performed on the specimens prior to testing. In general, the methodology was used for the present work. Crack opening loads were introduced to the specimens via piano hinges attached to the main specimen faces at a single end of each specimen. Hinges were bolted to the specimens using the technique presented. The cracks were extended a small distance from the end of the Kapton insert prior to testing. Just before precracking, the sides of the specimens were coated with water-soluble typewriter correction fluid to aid in crack visualization. Scribe marks were then made in the coating at half-inch intervals.

Kessler, Jeff A.↗

A Novel Rotating Flexure-Test Technique for Brittle Materials with Circular Geometries

The four-point bend test is one of the simplest and often the preferred flexural strength evaluation method for brittle materials. In this loading mode, fracture often initiates from a critical surface (or subsurface) flaw when subjected to a tensile stress state. However, if the critical flaw exists on the compression side of the test specimen, it may not activate to grow a crack and hence the resulting flexural strength will be higher than the true value. The goal of this study is to measure the true flexural strength of a solid or hollow cylindrical brittle specimen by ensuring that failure occurs at its weakest point by rotating along its longitudinal axis, thereby exposing and activating its critical surface flaw during a four-point bend test. A novel test fixture has been designed and fabricated, and the true flexural strengths of cylindrical brittle and quasi-brittle tubular specimens have been measured and compared to existing experimental data obtained through traditional four-point bend tests. In this work, experimental results showcase the orientation dependance on flexural strength for various materials. Additionally, similarities between experimental findings and those available in literature, including observations of fracture surfaces and relationships between surface roughness and material strength, are discussed.

36 MATERIALS SCIENCE↗

Linear variable differential transformer (LVDT)-based elongation measurements in Advanced Test Reactor high temperature irradiation testing

New materials are being considered for fuel, cladding and structures in next generation and existing nuclear reactors. These materials can undergo significant dimensional and physical changes during high temperature irradiations. Currently, such changes are determined by repeatedly irradiating a specimen for a specified period of time in the Advanced Test Reactor (ATR) and then removing it from the reactor for evaluation. The labor and time to remove, examine and return irradiated samples for each measurement make this approach very expensive. In addition, such techniques provide limited data and may disturb the phenomena of interest. To resolve these issues, an instrumented creep testing capability is being developed for specimens irradiated under pressurized water reactor coolant conditions in the ATR at the Idaho National Laboratory (INL). This paper reports the status of INL efforts to develop this testing capability. In addition to providing an overview of in-pile creep test capabilities available at other test reactors, this paper focuses on efforts to design and evaluate a prototype test rig in an autoclave at INL’s High Temperature Test Laboratory.

99 GENERAL AND MISCELLANEOUS↗

Durability Testing of Commercial Ceramic Materials

Technical efforts by AlliedSignal Engines in DOE/NASA-funded project from February, 1978 through December, 1995 are reported in the fields ceramic materials for gas turbine engines and cyclic thermal durability testing. A total of 29 materials were evaluated in 40 cyclic oxidation exposure durability tests. Ceramic test bars were cyclically thermally exposed to a hot combustion environment at temperatures up to 1371 C (2500 F) for periods of up to 3500 hours, simulating conditions typically encountered by hot flowpath components in an automotive gas turbine engine. Before and after exposure, quarter-point flexure strength tests were performed on the specimens, and fractography examinations including scanning electron microscopy (SEM) were performed to determine failure origins.

Schienle, J. L.↗

Irradiation Testing of Additively Manufactured Materials for LWR Applications: Alloy 718 and 316L Stainless Steel

The objective of this NSUF Project is to assess the changes in irradiated additively manufactured (AM) material properties as compared to non-irradiated material. Type 316L stainless steel and Alloy 718 samples were produced using Direct Metal Laser Melting (DMLM) fabrication. Materials produced from this fabrication method have several potential applications within the nuclear industry as reactor internal repair parts, fuel debris resistant filters, or fuel spacers within existing light water reactors (LWRs). AM materials have been shown to achieve equivalent mechanical behavior in simulated reactor environments as compared to wrought materials, but have significantly more flexibility when it comes to unique design features. The increased component design flexibility makes these AM materials an attractive choice for both current LWR applications as well as for small modular reactor (SMR) designs. Prior to use of these materials in reactor fleet operation, the industry as a whole must evaluate the effects of irradiation on their material properties. Standard 0.4 inch thick Compact Tension specimens and SSJ3 type tensile bars were neutron irradiated at the Advanced Test Reactor to ~1 dpa for the purpose of performing a variety of mechanical tests in a range of simulated environments applicable to LWRs. For the ductile austenitic Type 316L stainless steel, the irradiated data will be used to confirm that the AM process produces materials with properties that are equivalent to wrought materials under testing conditions applicable to LWR operation. Transmission electron microscopy analysis was also performed in order to understand microstructural and microchemical changes induced in each material in response to neutron irradiation. If possible, data collected from these AM 316L samples will be used to remove fluence limits from specifications of ASME code cases for this alloy, which will give vendors much more flexibility in building future components.

36 - MATERIALS SCIENCE↗

3D printed polymer gaskets for custom-form batteries

Additive manufacturing (AM) processes, like 3D printing, help to facilitate complex and customizable battery geometries which can provide design freedom and enhance volumetric energy density within electronic devices. AM materials must have the thermal and mechanical properties that enable printability, and when used in batteries, AM materials must also be chemically and electrochemically compatible with the battery chemistry. The compatibility between AM materials and the battery is of particular importance for the cell packaging materials which must be inert and are often overlooked. This study systematically studies AM-compatible polymeric materials for use as gaskets in lithium-ion cells. The materials investigated include three thermoplastics suitable for material extrusion printing: polylactic acid (PLA), polycarbonate, and polypropylene/polyethylene copolymer (PPPEC); and two photoresins suitable for vat photopolymerization (VPP) printing: an acrylate-based photoresin and a polyethylene glycol diacrylate photoresin. The AM gasket materials were tested in comparison to a conventional commercial polypropylene gasket. Mechanical testing (swell measurements and material stiffness) and electrochemical testing (linear sweep voltammetry and galvanostatic cycling of full cells) demonstrated that PLA and the VPP polymers were the least compatible with the lithium-ion battery chemistry, despite their prevalent use in studies of AM batteries, and that PPPEC was the most compatible.

3D printing↗

Single-Crystal Tungsten Carbide in High-Temperature In-Situ Additive Manufacturing Characterization

Nanoindenters are commonly used for measuring the mechanical properties of a wide variety of materials with both industrial and scientific applications. Typically, these instruments employ an indenter made of a material of suitable hardness bonded to an appropriate shaft or holder to create an indentation on the material being tested. While a variety of materials may be employed for the indenter, diamond and boron carbide are by far the most common materials used due to their hardness and other desirable properties. However, as the increasing complexity of new materials demands a broader range of testing capabilities, conventional indenter materials exhibit significant performance limitations. Among these are the inability of diamond indenters to perform in-situ measurements at temperatures above 600oC in air due to oxidation of the diamond material and subsequent degradation of the indenters mechanical properties. Similarly, boron carbide also fails at high temperature due to fracture. [1] Transition metal carbides possess a combination of hardness and mechanical properties at high temperatures that offer an attractive alternative to conventional indenter materials. Here we describe the technical aspects for the growth of single-crystal tungsten carbide (WC) for use as a high-temperature indenter material, and we examine a possible approach to brazing these crystals to a suitable mount for grinding and attachment to the indenter instrument. The use of a by-product of the recovery process is also suggested as possibly having commercial value.

36 MATERIALS SCIENCE↗

Characterization of the Mechanical Trash Compactor Bag Removal Force

Managing trash accumulation is a critical challenge in human space explorations since the trash volume and mass can significantly influence launch cost and operational efficiency. This study aids the development of a Mechanical Trash Compactor (Mpactor) by testing the removal force required to remove a “trash bag” from the Mpactor. To do this, a Pneumatic Pressure Mandrel System was designed to simulate the normal force trash would exerts on the trash bag and subsequently the sidewalls of the Mpactor. For various levels of sidewall normal force, the removal force required to remove the simulated trash bag from the Mpactor compaction chamber was measured. This testing is used to identify optimal bag materials. Additionally, testing was done on both the native stainless steel walls of the compaction chamber as well as the walls after being Teflon lined. Split-plot ANOVA, simple main effects analysis, Holm’s post hoc comparisons for interaction, and sensitivity analyses were conducted to assess the influence of trash bag and sidewall materials on the required removal force. It was found that Teflon reduced the force required to remove the trash bag as well as reduced material-dependent variation in removal force. Testing showed that Teflon reduced the required removal force with a Polyvinylidene Fluoride , an unidentified Ethylene acrylate - Low Density Polyethylene copolymer, and a Polyvinyl Chloride all requiring significantly less removal force than the other materials tested.

pressure mandrel↗

Status of the Fuel Fragment Dispersal Studies at Oak Ridge National Laboratory

During a loss-of-coolant accident, a nuclear fuel rods undergo balloon and burst. High burnup fuel is known to fragment and pulverize leading to the potential for the fuel to disperse through the burst opening either during the initial burst or following the burst during the reflood event. This milestone summarizes the design and assembly of a system to study dispersal in a postburst event. Surrogate fuel material (HfO2, tungsten, and yttria-stabilized zirconia [YSZ]) dispersing from as-burst loss-of-coolant accident (LOCA) test specimens was extensively investigated, along with dispersal of actual nuclear fuel following a LOCA Severe Accident Test Station (SATS) test. Surrogate material tests spanned a variety of burst geometries, particle types, particle size distributions, and rod oscillation loadings (frequency and amplitude combinations).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Offgassing test methodology for composite materials

A significant increase in the use of composite materials has occurred during the past 20 years. Associated with this increased use is the potential for employees to be exposed to offgassing components from composite systems. Various components in composite systems, particularly residual solvents, offgas under various conditions. The potential for offgassing to occur increases as a composite material is heated either during cure or during lay-up operations. Various techniques can be employed to evaluate the offgassing characteristics of a composite system. A joint effort between AIA and SACMA resulted in the drafting of a proposed test method for evaluating the offgassing potential of composite materials. The purpose of testing composite materials for offgassing is to provide the industrial hygienist with information which can be used to assess the safety of the workplace. This paper outlines the proposed test method and presents round robin testing data associated with the test method. Also in this presentation is a discussion of classes of compounds which require specialized sampling techniques.

Scheer, Dale A.↗

Mechanical Impact Testing: A Statistical Measurement

In the decades since the 1950s, when NASA first developed mechanical impact testing of materials, researchers have continued efforts to gain a better understanding of the chemical, mechanical, and thermodynamic nature of the phenomenon. The impact mechanism is a real combustion ignition mechanism that needs understanding in the design of an oxygen system. The use of test data from this test method has been questioned due to lack of a clear method of application of the data and variability found between tests, material batches, and facilities. This effort explores a large database that has accumulated over a number of years and explores its overall nature. Moreover, testing was performed to determine the statistical nature of the test procedure to help establish sample size guidelines for material characterization. The current method of determining a pass/fail criterion based on either light emission or sound report or material charring is questioned.

Engel, Carl D.↗

Dynamic Scaling Analysis of Accelerated Irradiation Testing on Additive Manufacturing Materials by Positron Annihilation

The timely applications of Additive Manufacturing (AM) materials in nuclear environments require accelerated irradiation tests, mainly ion irradiation to enable rapid prototyping. Low dose ion irradiation would cause sub-nanostructure changes by generation of lattice defects, vacancies, vacancy clusters and voids and void swelling caused by cellular dislocations. Positron Annihilation Lifetime (PAL), a novel technology, sensitive towards sub-nanostructure morphology with high accuracy (about 10-7 vacancy per atom), supported by Transition Electron Microscope (TEM) would be applied to identify the type and total size of the defects. The subsequent PAL measurements and TEM surface studies would be followed by PAL analysis that includes sophisticated trapping model. The PAS results would become an input to dynamic scaling analysis (that predicts radiation effects from low dose studies for high dose effects), which incorporate mean-field theory model. The final effect is an in-depth understanding of the microstructure evolution of AM materials under ion irradiation which can be extrapolated to the studies of neutron irradiation, since ion-irradiation takes less time and do not cause the irradiation hazard. The working hypothesis is that PAL technology, that have excellent sensitivity to low-defect concentration would help to identify ion-induced material damage on the atomic and nano-scale level, which then could be extrapolated to understand the neutron damage better.

accelerated irradiation testing↗

Testing for characterization of the materials from radiological point of view

The nuclear techniques and materials are now used in a large number of applications, both in medicine and industry. Due to this fact, new materials are needed in order to assure the radiological protection of the personnel involved in these activities. But, finally, all these materials have to be tested for some specific parameters, in order to prove that they are adequate for the purposed for which they were created. One of the important parameters of the materials used for the radiological protection is the attenuation coefficient. The attenuation coefficient of the ionizing radiation composed by particles without electrical charge (X,γ-ray and neutron) is the most important parameter for the materials used for the shielding of these ionizing radiation. This paper deals with the experimental methods developed for the determination of the attenuation of fast and thermal neutrons. These experimental methods, involved the use of Am-Be source and U-120 Cyclotron of IFIN-HH. For the tests which were done at the U-120 Cyclotron, a number of experiments had to be performed, in order to establish the irradiation geometry and the dose equivalent rates in front of and behind the material samples. The experimental results obtained for samples of several materials, confirmed the methods as adequate for the aim of the test.

36 MATERIALS SCIENCE↗

Compatibility Testing of Non-Metallic Materials for the Urine Processor Assembly (UPA) of International Space Station (ISS)

In the International Space Station (ISS), astronauts will convert urine into potable water with the Urine Processor Assembly (UPA). The urine is distilled, with the concentrated form containing about 15% brine solids, and the dilute form as a blend of pre-treated urine/wastewater. Eighteen candidate non-metallic materials for use with the UPA were tested in 2000 for compatibility with the concentrated and dilute urine solutions for continuous times of at least 30 days, and at conditions of 0.5 psia pressure and 100 F, to simulate the working UPA environment. A primary screening test for each material (virgin and conditioned) was dynamic mechanical analysis (DMA) in the stress relaxation mode, with the test data used to predict material performance for a 10-year use in space. Data showed that most of the candidate materials passed the compatibility testing, although a few significant changes in stress relaxation modulus were observed.

Wingard, Charles Doug↗