Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “LOAD TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Conceptual Design of a Tiltduct Reference Vehicle for Urban Air Mobility

NASA is establishing a fleet of conceptual air vehicle designs to support research and development for Urban Air Mobility (UAM). This fleet of vehicles will enable examination of the sensitivity of UAM vehicle designs to technology assumptions, identify key research and development needs for UAM aircraft, and provide the UAM community with reference vehicles that are publicly available and based upon known assumptions. To date, five six-passenger reference vehicles have been published: a quadrotor, a side-by-side, a lift-plus-cruise, a single-main-rotor helicopter, and a tiltwing. To increase the breadth of vehicle technologies encapsulated in the fleet of NASA UAM reference vehicles, this paper establishes a tiltduct vehicle as an addition to the fleet. The fleet will continue to evolve as future analyses and trade studies are performed. The tiltduct reference vehicle has six tilting ducted proprotors. This paper describes the initial configuration downselection; discusses ducted proprotor design rules of thumb as they applied to the conceptual design of the reference vehicle; describes the vehicle sizing, trade studies, and tuning of models performed; and finally, compares the resulting tiltduct vehicle against the other six-passenger NASA UAM reference vehicles. The high-level analyses performed for this study did not indicate significant differences in performance between the tiltduct and tiltwing reference vehicles, and so vehicle performance alone may not be a key driver in the selection of a tiltduct vehicle over a tiltwing vehicle. However, if ducts are found to have significant acoustical benefits, then acoustical priorities may provide a compelling reason to incorporate ducted proprotors. One significant limitation of the design presented in this paper is that the ducted proprotor performance was tuned based upon performance characteristics observed during historical tests with disk loadings (defined as thrust divided by proprotor disk area) of 125-250 lb/ft^2. The tiltduct vehicle designed in this study has a disk loading of 30 lb/ft^2, to be more representative of UAM vehicles; further studies to understand performance of ducted proprotors at representative disk loadings are warranted.

Tiltduct↗

Conceptual Design of a Tiltduct Reference Vehicle for Urban Air Mobility

NASA is establishing a fleet of conceptual air vehicle designs to support research and development for Urban Air Mobility (UAM). This fleet of vehicles will enable examination of the sensitivity of UAM vehicle designs to technology assumptions, identify key research and development needs for UAM aircraft, and provide the UAM community with reference vehicles that are publicly available and based upon known assumptions. To date, five six-passenger UAM reference vehicles have been published: a single-main-rotor helicopter, a side-by-side helicopter, a quadrotor, a lift-plus-cruise, and a tiltwing. To increase the breadth of vehicle technologies encapsulated in the fleet of NASA UAM reference vehicles, this paper establishes a tiltduct vehicle as an addition to the fleet. The fleet will continue to evolve as future analyses and trade studies are performed. The tiltduct UAM reference vehicle has six tilting ducted proprotors. This paper describes the initial configuration downselection; discusses ducted proprotor design rules of thumb as they applied to the conceptual design of the reference vehicle; describes the vehicle sizing, trade studies, and tuning of models performed; and finally, compares the resulting tiltduct vehicle against the other six-passenger NASA UAM reference vehicles. The high-level analyses performed for this study did not indicate significant differences in performance between the tiltduct and tiltwing reference vehicles, and so vehicle performance alone may not be a key driver in the selection of a tiltduct vehicle over a tiltwing vehicle. However, if ducts are found to have significant acoustical benefits, then acoustical priorities may provide a compelling reason to incorporate ducted proprotors. One significant limitation of the design presented in this paper is that the ducted proprotor performance was tuned based upon performance characteristics observed during historical tests with disk loadings (defined as thrust divided by proprotor disk area) of 125-250 lb/ft$^2$. The tiltduct vehicle designed in this study has a disk loading of 30 lb/ft$^2$, to be more representative of UAM vehicles; further studies to understand performance of ducted proprotors at representative disk loadings are warranted.

Tiltduct↗

Shock- and Corrosion-Resistant Bearings for Space Mechanisms

Nickel-titanium (NiTi) alloys are an emerging class of materials for rolling element bearing applications that require superior corrosion resistance and/or high load capability. Certain space mechanisms fall into one or both of those categories. Often, due to size and mass considerations, space mechanism systems are limited in torque margin and necessarily require small, precision-instrument bearings with very little frictional drag (i.e., low torque). In addition, space mechanism bearings must survive launch conditions without suffering raceway dents known as brinnelling, which would increase operating torque and reduce overall smoothness. Consequently, a bearing material or design that reduces or eliminates brinnelling under high contact stress conditions would represent a beneficial technology advancement. One specific alloy, nickel-titanium-hafnium (NiTi-Hf), under development for several years at the NASA Glenn Research Center as a bearing material, has the potential to mitigate concerns about brinnelling under extreme load conditions due to its unusually high elastic strain capability. In the present work, a sample of small precision bearings produced with three different ball materials (steel, ceramic, and NiTi-Hf) is subjected to a range of load conditions sufficient to dent the races. The dent depth as a function of load is compared and demonstrates that NiTi-Hf has the potential to increase bearing load capacity from the perspective of brinnelling under severe load conditions; additional testing of full NiTi-Hf bearings demonstrates corrosion resistance superior to that of 440C bearings.

Bearings↗

Examination of Cavity Formation in Cold-Worked Alloy 690

Although stress corrosion cracking (SCC) has not been reported in Alloy 690 components after more than 30 years of pressure water reactor (PWR) service, susceptibility to SCC growth in PWR primary water has been reported by many labs for highly CW Alloy 690 along with isolated observations of crack initiation. Post-test examinations on SCC initiation specimens suggested a key role of creep by inducing the formation and growth of grain boundary cavities at carbide interfaces leading to intergranular cracking. However, it is clear that high levels of cold work can produce grain boundary voids and complicates the quantitative evaluation of damage evolution during testing in high-temperature water. Therefore, it is crucial to understand how to properly examine and classify this type of damage in the pre-test condition and establish its evolution with time. This paper outlines our observational protocols on how to best prepare sample surfaces to avoid inducing artifacts, and to perform subsequent examinations utilizing scanning electron microscopy, transmission electron microscopy and focused ion beam milling to assess the formation and development of grain boundary cavities. Detailed examinations will be reviewed on several commercial Alloy 690 heats in the pre-test CW condition and after long-term initiation testing at constant load in 360°C simulated PWR primary water to effectively document grain boundary cavity formation and growth leading to crack initiation.

Olszta, Matthew J.↗

Experimental Methods for the Performance Test of Environment-Assisted Cracking (EAC) in Nuclear Industry and Examples through NSUF

Environmentally assisted cracking (EAC) is a critical failure mode in nuclear reactor environments, where materials are exposed to high temperatures, radiation, and corrosive media. Specific EAC studies in nuclear environments include stress corrosion cracking in primary water chemistry, irradiation-assisted stress corrosion cracking (IASCC) under neutron exposure, and hydrogen induced cracking (HIC) in reactor pressure vessels. The experimental methodologies of EAC include slow strain rate testing (SSRT), constant load, and cyclic loading techniques, conducted in autoclaves designed to simulate the reactor’s operational environments. This paper highlights several experimental case studies, especially on IASCC, conducted within the Nuclear Science User Facilities (NSUF).

36 - MATERIALS SCIENCE↗

Improved Tensile Adhesion Specimens for High Strength Epoxy Systems in Aerospace Applications

An improved tensile adhesion button has been designed and tested that results in higher measured tensile adhesion strength while providing increased capability for testing high strength epoxy adhesive systems. The best attributes of two well-established tensile button designs were combined and refined into an optimized tensile button. The most significant design change to the tensile button was to improve alignment of the bonded tensile button specimens during tensile testing by changing the interface between the tensile button and the tensile test machine. The established or old button design uses a test fixture that pulls from a grooved annulus or anvil head while the new button design pulls from a threaded hole in the centerline of the button. Finite element (FE) analysis showed that asymmetric loading of the established anvil head tensile button significantly increases the stress concentration in the adhesive, causing failure at lower tensile test loads. The new tensile button was designed to eliminate asymmetric loading and eliminate misalignment sensitivity. Enhanced alignment resulted in improved tensile adhesion strength measurement up to 13.8 MPa (2000psi) over the established button design. Another design change increased the capability of the button by increasing the threaded hole diameter allowing it to test high strength epoxy systems up to 85 MPa(less than 12,000 psi). The improved tensile button can be used in button- to-button or button-to-panel configurations.

Haddock, M. Reed↗

JT9D engine diagnostics. Task 2: Feasibility study of measuring in-service flight loads

The feasibility of measuring JT9D propulsion system flight inertia loads on a 747 airplane is studied. Flight loads background is discussed including the current status of 747/JT9D loads knowledge. An instrumentation and test plan is formulated for an airline-owned in-service airplane and the Boeing-owned RA001 test airplane. Technical and cost comparisons are made between these two options. An overall technical feasibility evaluation is made and a cost summary presented. Conclusions and recommendations are presented in regard to using existing inertia loads data versus conducting a flight test to measure inertia loads.

Kafka, P. G.↗

Shot 3 Post-Shot Report: Fault Analysis of MK-X Data [Slides]

This presentation constitutes a post-shot report for the MK-X performance on Shot 3 (13 July 2022). It focuses primarily on the analysis of electrical faults which have been a persistent issue in MK-X performance and were a significant focus of the test. The MK-X is a helical flux compression generator (HFCG) that has been manufactured in a novel and very cost-effective way. Shot 3 was the fourth test in a series which began with a low initial-current-level HFCG test coupled to a dummy load (Shot 0) and then a high stress test (Shot 1) coupled to a primitive pulse forming network (PFN). Shot 0 performed close to expectation but Shot 1 had early time losses that could not be explained. As a result, Shots 2 and 3 had dual goals. Each shot looked at MK-X performance relative to the early time losses, and since the amount of current generated on the first two tests was a useful amount, we coupled to a fast R43S Ranchero flux compression generator for Shot 2 to ascertain Ranchero’s performance with higher-than-ever initial current and another PFN load. Then Shot 3 implemented a specific change to the MK-X and coupled to only a low inductance PFN load. The report shows that Shots 1-3 all have qualitatively similar losses and the change made for Shot 3 to explore losses led to even further losses. However, the PFN on shot 3 was low inductance and in spite of the losses, 32 MA was generated. This report discusses the losses seen specifically on Shot 3 and compares the electrical and camera data along with a careful comparison to 3 D MHD modeling.

42 ENGINEERING↗

Effect of outdoor exposure at ambient and elevated temperatures on fatigue life of Ti-6Al-4V titanium alloy sheet in the annealed and the solution treated and aged condition

Specimens of Ti-6Al-4V titanium alloy sheet in the annealed and the solution-treated and aged heat-treatment condition were exposed outdoors at ambient and 560 K (550 F) temperatures to determine the effect of outdoor exposure on fatigue life. Effects of exposure were determined by comparing fatigue lives of exposed specimens to those of unexpected specimens. Two procedures for fatigue testing the exposed specimens were evaluated: (1) fatigue tests conducted outdoors by applying 1200 load cycles per week until failure occurred and (2) conventional fatigue tests (continuous cycling until failure occurred) conducted indoors after outdoor exposure under static load. The exposure period ranged from 9 to 28 months for the outdoor fatigue-test group and was 24 months for the static-load group. All fatigue tests were constant-amplitude bending of specimens containing a drilled hole (stress concentration factor of 1.6). The results of the tests indicate that the fatigue lives of solution-treated and aged specimens were significantly reduced by the outdoor exposure at 560 K but not by the exposure at ambient temperature. Fatigue lives of the annealed specimens were essentially unaffected by the outdoor exposure at either temperature. The two test procedures - outdoor fatigue test and indoor fatigue test after outdoor exposure - led to the same conclusions about exposure effects.

Phillips, E. P.↗

A torque, tension and stress corrosion evaluation of high strength A286 bolts

The problems associated with overtorque applied to the Booster Separation Motor (BSM) Igniter Adapter high strength 200 KSI (1379 Mpa) A286 CRES bolts and the threaded holes of the 7075-T73 aluminum alloy BSM cases are addressed. The evaluation included torque, tensile, and stress corrosion tests incorporating the A286 CRES bolts and the 7075-T73 aluminum alloy BSM cases. The tensile test data includes ultimate tensile load (UTL), Johnson's 2/3 yield load (J2/3YL), proportional limit load (PLL), and total bolt stretch. Torque tension data includes torque, torque induced load, and positive and negative break-away torque. Stress corrosion test data reflect the overtorque and the resulting torque induced loads sustained by the A286 CRES bolts torqued into a 7075-T73 aluminum alloy forged dome with threaded holes. After 60 days of salt fog exposure, the positive and the negative break-away torques, the subsequent mechanical property tensile test results, and the BSM dome threaded hole axial tensile pullout loads are reported.

Montano, J. W.↗

Failure of composite plates under static biaxial planar loading

The project involved detailed investigations into the failure mechanisms in composite plates as a function of hole size (holes centrally located in the plates) under static loading. There were two phases to the project, the first dealing with uniaxial loads along the fiber direction, and the second dealing with coplanar biaxial loading. Results for the uniaxial tests have been reported and published previously, thus this report will place emphasis on the second phase of the project, namely the biaxial tests. The composite plates used in the biaxial loading experiments, as well as the uniaxial, were composed of a single ply unidirectional graphite/epoxy prepreg sandwiched between two layers of transparent thermoplastic. This setup enabled us to examine the failure initiation and propagation modes nondestructively, during the test. Currently, similar tests and analysis of results are in progress for graphite/epoxy cruciform shaped flat laminates. The results obtained from these tests will be available at a later time.

Waas, Anthony M.↗

Experimental investigation of cyclic thermomechanical deformation in torsion

An investigation of thermomechanical testing and deformation behavior of tubular specimens under torsional loading is described. Experimental issues concerning test accuracy and control specific to thermomechanical loadings under a torsional regime are discussed. A series of shear strain-controlled tests involving the nickel-base superalloy Hastelloy X were performed with various temperature excursions and compared to similar thermomechanical uniaxial tests. The concept and use of second invariants of the deviatoric stress and strain tensors as a means of comparing uniaxial and torsional specimens is also briefly presented and discussed in light of previous thermomechanical tests conducted under uniaxial conditions.

Ellis, John R.↗

Specimens and Reusable Fixturing for Testing Advanced Aeropropulsion Materials Under In-Plane Biaxial Loading: Results of Conceptual Design Study - Part 1

A design study was undertaken to investigate the feasibility of using simple specimen designs and reusable fixturing for in-plane biaxial tests planned for advanced aeropropulsion materials. Materials of interest in this work include: advanced metallics, polymeric matrix composites, metal and intermetallic matrix composites, and ceramic matrix composites. Early experience with advanced metallics showed that the cruciform specimen design typically used in this type of testing was impractical for these materials, primarily because of concerns regarding complexity and cost. The objective of this research was to develop specimen designs, fixturing, and procedures which would allow in-plane biaxial tests to be conducted on a wide range of aeropropulsion materials while at the same time keeping costs within acceptable limits. With this goal in mind. a conceptual design was developed centered on a specimen incorporating a relatively simple arrangement of slots and fingers for attachment and loading purposes. The ANSYS finite element code was used to demonstrate the feasibility of the approach and also to develop a number of optimized specimen designs. The same computer code was used to develop the reusable fixturing needed to position and grip the specimens in the load frame. The design adopted uses an assembly of slotted fingers which can be reconfigured as necessary to obtain optimum biaxial stress states in the specimen gage area. Most recently, prototype fixturing was manufactured and is being evaluated over a range of uniaxial and biaxial loading conditions.

Ellis, J. R.↗

Buckling Response of a Large-Scale, Seamless, Orthogrid-Stiffened Metallic Cylinder

Results from the buckling test of a compression-loaded 8-ft-diameter seamless (i.e., without manufacturing joints), orthogrid-stiffened metallic cylinder are presented. This test was used to assess the buckling response and imperfection sensitivity characteristics of a seamless cylinder. In addition, the test article and test served as a technology demonstration to show the application of the flow forming manufacturing process to build more efficient buckling-critical structures by eliminating the welded joints that are traditionally used in the manufacturing of large metallic barrels. Pretest predictions of the cylinder buckling response were obtained using a finite-element model that included measured geometric imperfections. The buckling load predicted using this model was 697,000 lb, and the test article buckled at 743,000 lb (6% higher). After the test, the model was revised to account for measured variations in skin and stiffener geometry, nonuniform loading, and material properties. The revised model predicted a buckling load of 754,000 lb, which is within 1.5% of the tested buckling load. In addition, it was determined that the load carrying capability of the seamless cylinder is approximately 28% greater than a corresponding cylinder with welded joints.

Rudd, Michelle Tillotson↗

Thermal and Fluid Modeling of the CRYogenic Orbital TEstbed (CRYOTE) Ground Test Article (GTA)

The purpose of this study was to anchor thermal and fluid system models to data acquired from a ground test article (GTA) for the CRYogenic Orbital TEstbed - CRYOTE. To accomplish this analysis, it was broken into four primary tasks. These included model development, pre-test predictions, testing support at Marshall Space Flight Center (MSFC} and post-test correlations. Information from MSFC facilitated the task of refining and correlating the initial models. The primary goal of the modeling/testing/correlating efforts was to characterize heat loads throughout the ground test article. Significant factors impacting the heat loads included radiative environments, multi-layer insulation (MLI) performance, tank fill levels, tank pressures, and even contact conductance coefficients. This paper demonstrates how analytical thermal/fluid networks were established, and it includes supporting rationale for specific thermal responses seen during testing.

Piryk, David↗

ORBIT simulations of fast ion power loads on the wall of the Divertor Tokamak Test

Abstract Neutral beam injection in tokamaks produces a population of fast ions, which interact with 3D magnetic fields in a variety of ways, often resulting in energetic particle losses in very short times to the wall. Careful design of neutral beams and active control of error fields helps to keep these losses to a minimum. Nevertheless, past experience in tokamaks in the 1980s and detailed simulations for future machines, such as International Thermonuclear Experimental Reactor, suggest that very localized fast ion losses (‘hot spots’) can be present, even if the overall losses are low. In this paper, we discuss this issue in the Divertor Tokamak Test (DTT) project, and we show that in the standard single-null full-power scenario of the DTT, fast ions produce two hot spots, corresponding approximately to the beam injection and exit toroidal angles: the former being mainly due to prompt losses/passing particles, while the latter is due to trapped ions. However, the maximum power load in these spots is of the order ∼ 63 kW m −2 , below the tolerance of plasma-facing components of the machine.

Physics↗

In situ environmental scanning electron microscope observations of colloidal failure mechanisms using the Brazilian disk test

This paper presents data produced using a novel test fixture to study the crack initiation and fracture mechanisms in brittle colloidal systems, in situ in an Environmental Scanning Electron Microscope (ESEM), based on the Brazilian disk test. The test is based on diametral compression loading of a disk of material, which causes a tensile stress in the centre of the disk perpendicular to the loading direction. Key advantages over commercial tensile tests are simplicity of specimen preparation, especially important for fragile and brittle materials, which because of their nature in many cases cannot be microscopically characterised after testing. The test was successful in creating the desired perpendicular tensile stresses and yielded diametral cracks across the latex specimens. It was found that when end crushing was minimal, multiple cracks initiated at several points on the disk and a number of factors appeared to influence the propagation of cracks through the latex, these include: particle packing arrangements, surface defects, and the presence of other cracks. Following the onset of fracture, it was observed that the cracks connected to form a single failure route, here described as the path of least resistance. This, in essence, resulted in the crack taking a route around stronger, more ordered regions of the latex (be they “crystals” or surface defects). The experimental results presented and discussed here represent the first attempt to utilise this loading arrangement in the study of crack propagation in colloidal systems.

42 ENGINEERING↗

Test fixture insures high degree of accuracy in flexure tests

Modified die set improves accuracy in load application, minimizes problems of parallelism, and eliminates testing errors normally encountered during flexure tests. Test results are given for a comparison test of the old and new fixtures.

Duran, E. M.↗