Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

TU-AB-202-05: GPU-Based 4D Deformable Image Registration Using Adaptive Tetrahedral Mesh Modeling

Purpose: Deformable image registration (DIR) has been employed today as an automated and effective segmentation method to transfer tumor or organ contours from the planning image to daily images, instead of manual segmentation. However, the computational time and accuracy of current DIR approaches are still insufficient for online adaptive radiation therapy (ART), which requires real-time and high-quality image segmentation, especially in a large datasets of 4D-CT images. The objective of this work is to propose a new DIR algorithm, with fast computational speed and high accuracy, by using adaptive feature-based tetrahedral meshing and GPU-based parallelization. Methods: The first step is to generate the adaptive tetrahedral mesh based on the image features of a reference phase of 4D-CT, so that the deformation can be well captured and accurately diffused from the mesh vertices to voxels of the image volume. Subsequently, the deformation vector fields (DVF) and other phases of 4D-CT can be obtained by matching each phase of the target 4D-CT images with the corresponding deformed reference phase. The proposed 4D DIR method is implemented on GPU, resulting in significantly increasing the computational efficiency due to its parallel computing ability. Results: A 4D NCAT digital phantom was used to test the efficiency and accuracy of our method. Both the image and DVF results show that the fine structures and shapes of lung are well preserved, and the tumor position is well captured, i.e., 3D distance error is 1.14 mm. Compared to the previous voxel-based CPU implementation of DIR, such as demons, the proposed method is about 160x faster for registering a 10-phase 4D-CT with a phase dimension of 256×256×150. Conclusion: The proposed 4D DIR method uses feature-based mesh and GPU-based parallelism, which demonstrates the capability to compute both high-quality image and motion results, with significant improvement on the computational speed.

60 APPLIED LIFE SCIENCES↗

TU-FG-BRB-05: A 3 Dimensional Prompt Gamma Imaging System for Range Verification in Proton Radiotherapy

Purpose: To report on the initial developments of a clinical 3-dimensional (3D) prompt gamma (PG) imaging system for proton radiotherapy range verification. Methods: The new imaging system under development consists of a prototype Compton camera to measure PG emission during proton beam irradiation and software to reconstruct, display, and analyze 3D images of the PG emission. For initial test of the system, PGs were measured with a prototype CC during a 200 cGy dose delivery with clinical proton pencil beams (ranging from 100 MeV – 200 MeV) to a water phantom. Measurements were also carried out with the CC placed 15 cm from the phantom for a full range 150 MeV pencil beam and with its range shifted by 2 mm. Reconstructed images of the PG emission were displayed by the clinical PG imaging software and compared to the dose distributions of the proton beams calculated by a commercial treatment planning system. Results: Measurements made with the new PG imaging system showed that a 3D image could be reconstructed from PGs measured during the delivery of 200 cGy of dose, and that shifts in the Bragg peak range of as little as 2 mm could be detected. Conclusion: Initial tests of a new PG imaging system show its potential to provide 3D imaging and range verification for proton radiotherapy. Based on these results, we have begun work to improve the system with the goal that images can be produced from delivery of as little as 20 cGy so that the system could be used for in-vivo proton beam range verification on a daily basis.

60 APPLIED LIFE SCIENCES↗

TH-AB-209-09: Quantitative Imaging of Electrical Conductivity by VHF-Induced Thermoacoustics

Purpose: To demonstrate that very high frequency (VHF) induced thermoacoustics has the potential to provide quantitative images of electrical conductivity in Siemens/meter, much as shear wave elastography provides tissue stiffness in kPa. Quantitatively imaging a large organ requires exciting thermoacoustic pulses throughout the volume and broadband detection of those pulses because tomographic image reconstruction preserves frequency content. Applying the half-wavelength limit to a 200-micron inclusion inside a 7.5 cm diameter organ requires measurement sensitivity to frequencies ranging from 4 MHz down to 10 kHz, respectively. VHF irradiation provides superior depth penetration over near infrared used in photoacoustics. Additionally, VHF signal production is proportional to electrical conductivity, and prostate cancer is known to suppress electrical conductivity of prostatic fluid. Methods: A dual-transducer system utilizing a P4-1 array connected to a Verasonics V1 system augmented by a lower frequency focused single element transducer was developed. Simultaneous acquisition of VHF-induced thermoacoustic pulses by both transducers enabled comparison of transducer performance. Data from the clinical array generated a stack of 96-images with separation of 0.3 mm, whereas the single element transducer imaged only in a single plane. In-plane resolution and quantitative accuracy were measured at isocenter. Results: The array provided volumetric imaging capability with superior resolution whereas the single element transducer provided superior quantitative accuracy. Combining axial images from both transducers preserved resolution of the P4-1 array and improved image contrast. Neither transducer was sensitive to frequencies below 50 kHz, resulting in a DC offset and low-frequency shading over fields of view exceeding 15 mm. Fresh human prostates were imaged ex vivo and volumetric reconstructions reveal structures rarely seen in diagnostic images. Conclusion: Quantitative whole-organ thermoacoustic tomography will be feasible by sparsely interspersing transducer elements sensitive to the low end of the ultrasonic range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polarization Imaging for International Safeguards (FY2019)

A polarization imaging camera, Salsa (Bossa Nova Technologies) was evaluated for use in nuclear safeguards inspection with a focus on swipe sampling. The camera and supporting electronics and software determine the full Stokes parameters for the entire image field. The camera can be used for real-time video or still images. Stokes parameters S0, S1, S2, and S3 can be recorded for each pixel and exported for post processing. This study compared color photography to polarization imaging for powders on many surfaces under ambient lighting. False color images can be created from the Stokes parameters directly from the vendor software to highlight the various polarization states. In most cases, linear polarization showed the greatest effects. The polarization images are easy to collect and very sensitive to surfaces and textures. Fine powders are highlighted in the images, and particle size and refractive index effects were noticed. The images are not affected by ambient lighting (angle, or intensity). Lens choice is key and may require expert knowledge. Very small deposits of 1 µm particles were difficult to image using the standard video lens. General dirt on smooth surfaces and handprints are easily documented as well as powders on textured painted surfaces. Scratches on metal surfaces can be readily separated from other image features. The camera may be useful for tamper indication as surface damage is easy to discern and ambient lighting is not a concern.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Monte Carlo Simulation and Reconstruction: Assessment of Myocardial Perfusion Imaging of Tracer Dynamics With Cardiac Motion Due to Deformation and Respiration Using Gamma Camera With Continuous Acquisition

Purpose: Myocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) is routinely used for stress testing in nuclear medicine. Recently, our group extended its potential going from 3D visual qualitative image analysis to 4D spatiotemporal reconstruction of dynamically acquired data to capture the time variation of the radiotracer concentration and the estimated myocardial blood flow (MBF) and coronary flow reserve (CFR). However, the quality of reconstructed image is compromised due to cardiac deformation and respiration. The work presented here develops an algorithm that reconstructs the dynamic sequence of separate respiratory and cardiac phases and evaluates the algorithm with data simulated with a Monte Carlo simulation for the continuous image acquisition and processing with a slowly rotating SPECT camera. Methods: A clinically realistic Monte Carlo (MC) simulation is developed using the 4D Extended Cardiac Torso (XCAT) digital phantom with respiratory and cardiac motion to model continuous data acquisition of dynamic cardiac SPECT with slowly rotating gamma cameras by incorporating deformation and displacement of the myocardium due to cardiac and respiratory motion. We extended our previously developed 4D maximum-likelihood expectation-maximization (MLEM) reconstruction algorithm for a data set binned from a continuous list mode (LM) simulation with cardiac and respiratory information. Our spatiotemporal image reconstruction uses splines to explicitly model the temporal change of the tracer for each cardiac and respiratory gate that delineates the myocardial spatial position as the tracer washes in and out. Unlike in a fully list-mode data acquisition and reconstruction the accumulated photons are binned over a specific but very short time interval corresponding to each cardiac and respiratory gate. Reconstruction results are presented showing the dynamics of the tracer in the myocardium as it continuously deforms. These results are then compared with the conventional 4D spatiotemporal reconstruction method that models only the temporal changes of the tracer activity. Mean Stabilized Activity (MSA), signal to noise ratio (SNR) and Bias for the myocardium activities for three different target-to-background ratios (TBRs) are evaluated. Dynamic quantitative indices such as wash-in (K1) and wash-out (k2) rates at each gate were also estimated. Results: The MSA and SNR are higher with higher TBRs while biases were improved with higher TBRs to less than 10%. The correlation between exhalation-inhalation sequence with the ground truth during respiratory cycle was excellent. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Estimated values of K1 and k2 were also consistent with the ground truth. Conclusion: The continuous image acquisition for dynamic scan using conventional two-head gamma cameras can provide valuable information for MPI. Our study demonstrated the viability of using a continuous image acquisition method on a widely used clinical two-head SPECT system. Our reconstruction method showed better resolved myocardial walls during diastole to systole as compared to the ungated 4D image. Precise implementation of reconstruction algorithms, better segmentation techniques by generating images of different tissue types and background activity would improve the feasibility of the method in real clinical environment.

60 APPLIED LIFE SCIENCES↗

Image Collection Simulation Using High-Resolution Atmospheric Modeling

A new method is described for simulating the passive remote sensing image collection of ground targets that includes effects from atmospheric physics and dynamics at fine spatial and temporal scales. The innovation in this research is the process of combining a high-resolution weather model with image collection simulation to attempt to account for heterogeneous and high-resolution atmospheric effects on image products. The atmosphere was modeled on a 3D voxel grid by a Large-Eddy Simulation (LES) driven by forcing data constrained by local ground-based and air-based observations. The spatial scale of the atmospheric model (10–100 m) came closer than conventional weather forecast scales (10–100 km) to approaching the scale of typical commercial multispectral imagery (2 m). This approach was demonstrated through a ground truth experiment conducted at the Department of Energy Atmospheric Radiation Measurement Southern Great Plains site. In this experiment, calibrated targets (colored spectral tarps) were placed on the ground, and the scene was imaged with WorldView-3 multispectral imagery at a resolution enabling the tarps to be visible in at least 9–12 image pixels. The image collection was simulated with Digital Imaging and Remote Sensing Image Generation (DIRSIG) software, using the 3D atmosphere from the LES model to generate a high-resolution cloud mask. The high-resolution atmospheric model-predicted cloud coverage was usually within 23% of the measured cloud cover. The simulated image products were comparable to the WorldView-3 satellite imagery in terms of the variations of cloud distributions and spectral properties of the ground targets in clear-sky regions, suggesting the potential utility of the proposed modeling framework in improving simulation capabilities, as well as testing and improving the operation of image collection processes.

54 ENVIRONMENTAL SCIENCES↗

Qualitative and quantitative effects of harmonic echocardiographic imaging on endocardial edge definition and side-lobe artifacts

Harmonic imaging is a new ultrasonographic technique that is designed to improve image quality by exploiting the spontaneous generation of higher frequencies as ultrasound propagates through tissue. We studied 51 difficult-to-image patients with blinded side-by-side cineloop evaluation of endocardial border definition by harmonic versus fundamental imaging. In addition, quantitative intensities from cavity versus wall were compared for harmonic versus fundamental imaging. Harmonic imaging improved left ventricular endocardial border delineation over fundamental imaging (superior: harmonic = 71.1%, fundamental = 18.7%; similar: 10.2%; P <.001). Quantitative analysis of 100 wall/cavity combinations demonstrated brighter wall segments and more strikingly darker cavities during harmonic imaging (cavity intensity on a 0 to 255 scale: fundamental = 15.6 +/- 8.6; harmonic = 6.0 +/- 5.3; P <.0001), which led to enhanced contrast between the wall and cavity (1.89 versus 1.19, P <.0001). Harmonic imaging reduces side-lobe artifacts, resulting in a darker cavity and brighter walls, thereby improving image contrast and endocardial delineation.

NASA Discipline Cardiopulmonary↗

Delta-Doped Back-Illuminated CMOS Imaging Arrays: Progress and Prospects

In this paper, we report the latest results on our development of delta-doped, thinned, back-illuminated CMOS imaging arrays. As with charge-coupled devices, thinning and back-illumination are essential to the development of high performance CMOS imaging arrays. Problems with back surface passivation have emerged as critical to the prospects for incorporating CMOS imaging arrays into high performance scientific instruments, just as they did for CCDs over twenty years ago. In the early 1990's, JPL developed delta-doped CCDs, in which low temperature molecular beam epitaxy was used to form an ideal passivation layer on the silicon back surface. Comprising only a few nanometers of highly-doped epitaxial silicon, delta-doping achieves the stability and uniformity that are essential for high performance imaging and spectroscopy. Delta-doped CCDs were shown to have high, stable, and uniform quantum efficiency across the entire spectral range from the extreme ultraviolet through the near infrared. JPL has recently bump-bonded thinned, delta-doped CMOS imaging arrays to a CMOS readout, and demonstrated imaging. Delta-doped CMOS devices exhibit the high quantum efficiency that has become the standard for scientific-grade CCDs. Together with new circuit designs for low-noise readout currently under development, delta-doping expands the potential scientific applications of CMOS imaging arrays, and brings within reach important new capabilities, such as fast, high-sensitivity imaging with parallel readout and real-time signal processing. It remains to demonstrate manufacturability of delta-doped CMOS imaging arrays. To that end, JPL has acquired a new silicon MBE and ancillary equipment for delta-doping wafers up to 200mm in diameter, and is now developing processes for high-throughput, high yield delta-doping of fully-processed wafers with CCD and CMOS imaging devices.

imagers↗

Advances in imaging of chemically reacting flows

Many important chemically reacting systems are inherently multi-dimensional with spatial and temporal variations in the thermochemical state, which can be strongly coupled to interactions with transport processes. Fundamental insights into these systems require multi-dimensional measurements of the thermochemical state as well as fluid dynamics quantities. Laser-based imaging diagnostics provide spatially and temporally resolved measurements that help address this need. The state of the art in imaging diagnostics is continually progressing with the goal of attaining simultaneous multi-parameter measurements that capture transient processes, particularly those that lead to stochastic events, such as localized extinction in turbulent combustion. Development efforts in imaging diagnostics benefit from advances in laser and detector technology. This article provides a perspective on the progression of increasing dimensionality of laser-based imaging diagnostics and highlights the evolution from single-point measurements to 1D and 2D multi-parameter imaging and 3D high-speed imaging. This evolution is demonstrated using highlights of laser-based imaging techniques in combustion science research as an exemplar of a complex multi-dimensional chemically reacting system with chemistry–transport coupling. Imaging diagnostics impact basic research in other chemically reacting systems as well, such as measurements of near-surface gases in heterogeneous catalysis. The expanding dimensionality of imaging diagnostics leads to larger and more complex datasets that require increasingly demanding approaches to data analysis and provide opportunities for increased collaboration between experimental and computational researchers in tackling these challenges.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Importance of Imaging in Radiation Oncology for National Clinical Trials Network Protocols

Imaging is essential in successfully executing radiation therapy (RT) in oncology clinical trials. As technically sophisticated diagnostic imaging and RT were incorporated into trials, quality assurance in the National Clinical Trials Network groups entered a new era promoting image acquisition and review. Most trials involving RT require pre- and post-therapy imaging for target validation and outcome assessment. The increasing real-time (before and during therapy) imaging and RT object reviews are to ensure compliance with trial objectives. Objects easily transmit digitally for review from anywhere in the world. Physician interpretation of imaging and image application to RT treatment plans is essential for optimal trial execution. Imaging and RT data sets are used to credential RT sites to confirm investigator and institutional ability to meet trial target volume delineation and delivery requirements. Real-time imaging and RT object reviews can be performed multiple times during a trial to assess response to therapy and application of RT objects. This process has matured into an effective data management mechanism. When necessary, site and study investigators review objects together through web media technologies to ensure the patient is enrolled on the appropriate trial and the intended RT is planned and executed in a trial-compliant manner. Real-time imaging review makes sure: (1) the patient is entered and eligible for the trial, (2) the patient meets trial-specific adaptive therapy requirements, if applicable, and (3) the intended RT is according to trial guidelines. This review ensures the study population is uniform and the results are believable and can be applied to clinical practice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of deformed image-based dose calculations for adaptive radiotherapy of nasopharyngeal carcinoma

The ultimate goal of adaptive radiotherapy (ART) is to deliver truly customized radiation treatments. Currently, the quality of cone-beam computed tomography (CBCT) images is still inferior to that of conventional CT images in contour delineations and dose calculations for replanning purposes. This retrospective study aims to evaluate the dosimetric accuracy of using deformed conventional CT images for dose calculations, in the hope of inferring the feasibility of ART using planning CT (PCT) images that deformed to up-to-date CBCT images for patients with nasopharyngeal carcinoma (NPC). Thirty consecutive patients with NPC who had undergone 1 replan in their radiotherapy treatments were selected. The pretreatment PCT images were deformed to match the mid-treatment PCT images by deformable image registration. The same volumetric modulated arc therapy plan was then calculated on the deformed PCT images. The resulting dose distributions and dose volume histograms of the tumors and organs at risk (OARs) were compared with the original plan. Five dose levels, D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%}, were recorded for 9 NPC targets. Four dose levels, D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean}, were recorded for 15 OARs. The greatest percentage difference in observed dose for D{sub 98%}, D{sub 95%}, D{sub 50%}, D{sub 5%}, and D{sub 2%} of the targets were 1.71%, 1.55%, 0.64%, 0.97%, and 1.13%, respectively. The greatest percentage difference in observed dose for D{sub max}, D{sub 10%}, D{sub 50%}, and D{sub mean} of the OARs were -26.51% (left optic nerve), -17.06% (left optic nerve), 56.70% (spinal cord), and 18.97% (spinal cord), respectively. In addition, 29 of 45 (64%) dosimetric end points of the targets showed statistically significant dose differences (p p < 0.05). Dose calculations using deformed PCT images could result in significant dose uncertainties in target volumes and OARs. Larger dose deviations were found in OARs in comparison with target volumes. The spinal cord and optic nerve showed the greatest percentage dose differences and the clinical significance has yet to be determined. Deformable registration error was believed to be the problem causing the dose deviations. Owing to unknown clinical significanceof dose deviation results obtained from this study, a conventional CT scan is still required for replanning in patients with NPC who are experiencing significant anatomical changes during the course of radiation treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Proton imaging of stochastic magnetic fields

Recent laser-plasma experiments report the existence of dynamically significant magnetic fields, whose statistical characterization is essential for a complete understanding of the physical processes these experiments are attempting to investigate. In this paper, we show how a proton-imaging diagnostic can be used to determine a range of relevant magnetic-field statistics, including the magnetic-energy spectrum. To achieve this goal, we explore the properties of an analytic relation between a stochastic magnetic field and the image-flux distribution created upon imaging that field. This ‘Kugland image-flux relation’ was previously derived under simplifying assumptions typically valid in actual proton-imaging set-ups. We conclude that, as with regular electromagnetic fields, features of the beam’s final image-flux distribution often display a universal character determined by a single, field-scale dependent parameter – the contrast parameter $\unicode[STIX]{x1D707}\equiv d_{s}/{\mathcal{M}}l_{B}$ – which quantifies the relative size of the correlation length $l_{B}$ of the stochastic field, proton displacements $d_{s}$ due to magnetic deflections and the image magnification ${\mathcal{M}}$ . For stochastic magnetic fields, we establish the existence of four contrast regimes, under which proton-flux images relate to their parent fields in a qualitatively distinct manner. These are linear, nonlinear injective, caustic and diffusive. The diffusive regime is newly identified and characterized. The nonlinear injective regime is distinguished from the caustic regime in manifesting nonlinear behaviour, but as in the linear regime, the path-integrated magnetic field experienced by the beam can be extracted uniquely. Thus, in the linear and nonlinear injective regimes we show that the magnetic-energy spectrum can be obtained under a further statistical assumption of isotropy. This is not the case in the caustic or diffusive regimes. We discuss complications to the contrast-regime characterization arising for inhomogeneous, multi-scale stochastic fields, which can encompass many contrast regimes, as well as limitations currently placed by experimental capabilities on one’s ability to extract magnetic-field statistics. Furthermore, the results presented in this paper are of consequence in providing a comprehensive description of proton images of stochastic magnetic fields, with applications for improved analysis of proton-flux images.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Statistical characterization of experimental magnetized liner inertial fusion stagnation images using deep-learning-based fuel–background segmentation

Significant variety is observed in spherical crystal x-ray imager (SCXI) data for the stagnated fuel–liner system created in Magnetized Liner Inertial Fusion (MagLIF) experiments conducted at the Sandia National Laboratories Z-facility. As a result, image analysis tasks involving, e.g., region-of-interest selection (i.e. segmentation), background subtraction and image registration have generally required tedious manual treatment leading to increased risk of irreproducibility, lack of uncertainty quantification and smaller-scale studies using only a fraction of available data. We present a convolutional neural network (CNN)-based pipeline to automate much of the image processing workflow. This tool enabled batch preprocessing of an ensemble of N scans = 139 SCXI images across N exp = 67 different experiments for subsequent study. The pipeline begins by segmenting images into the stagnated fuel and background using a CNN trained on synthetic images generated from a geometric model of a physical three-dimensional plasma. The resulting segmentation allows for a rules-based registration. Our approach flexibly handles rarely occurring artifacts through minimal user input and avoids the need for extensive hand labelling and augmentation of our experimental dataset that would be needed to train an end-to-end pipeline. Here we also fit background pixels using low-degree polynomials, and perform a statistical assessment of the background and noise properties over the entire image database. Our results provide a guide for choices made in statistical inference models using stagnation image data and can be applied in the generation of synthetic datasets with realistic choices of noise statistics and background models used for machine learning tasks in MagLIF data analysis. We anticipate that the method may be readily extended to automate other MagLIF stagnation imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Constructing Self-Labeled Materials Imaging Datasets from Open Access Scientific Journals with EXSCLAIM!

Due to recent improvements in image resolution and acquisition speeds, materials microscopy is experiencing an explosion in imaging data. Yet, despite the volume of images generated, the overall accessibility landscape is highly fragmented, as researchers who do release images to the public, often only do so as snapshots of their larger private dataset in context of scientific journal publications. The effort to automatically consolidate images and descriptive information from web-based platforms has garnered broad attention from the computer vision, language technologies, and chemistry/materials informatics communities. However, these methods are problematic for scientific figures because over 30% of figures are compound in nature, and it is the individual images themselves, paired with relevant context, that are necessary for construction a proper labeled dataset. To this end, we outline in this paper the design of a software pipeline for the automatic EXtraction, Separation, and Caption-based natural Language Annotation of IMages from scientific figures (EXSCLAIM!). Successful consolidation of materials imaging across literature sources will enhance navigation and searchability of materials microscopy images for both novice and experienced researchers, as well as establish the framework necessary for users to search by images, text, or some combination of both.

36 MATERIALS SCIENCE↗

Synchrotron-based coherent scatter x-ray projection imaging using an array of monoenergetic pencil beams

Traditional projection x-ray imaging utilizes only the information from the primary photons. Low-angle coherent scatter images can be acquired simultaneous to the primary images and provide additional information. In medical applications scatter imaging can improve x-ray contrast or reduce dose using information that is currently discarded in radiological images to augment the transmitted radiation information. Other applications include non-destructive testing and security. A system at the Canadian Light Source synchrotron was configured which utilizes multiple pencil beams (up to five) to create both primary and coherent scatter projection images, simultaneously. The sample was scanned through the beams using an automated step-and-shoot setup. Pixels were acquired in a hexagonal lattice to maximize packing efficiency. The typical pitch was between 1.0 and 1.6 mm. A Maximum Likelihood-Expectation Maximization-based iterative method was used to disentangle the overlapping information from the flat panel digital x-ray detector. The pixel value of the coherent scatter image was generated by integrating the radial profile (scatter intensity versus scattering angle) over an angular range. Different angular ranges maximize the contrast between different materials of interest. A five-beam primary and scatter image set (which had a pixel beam time of 990 ms and total scan time of 56 min) of a porcine phantom is included. For comparison a single-beam coherent scatter image of the same phantom is included. The muscle-fat contrast was 0.10 {+-} 0.01 and 1.16 {+-} 0.03 for the five-beam primary and scatter images, respectively. The air kerma was measured free in air using aluminum oxide optically stimulated luminescent dosimeters. The total area-averaged air kerma for the scan was measured to be 7.2 {+-} 0.4 cGy although due to difficulties in small-beam dosimetry this number could be inaccurate.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementing an Accurate and Rapid Sparse Sampling Approach for Low-Dose Atomic Resolution STEM Imaging

Aberration correction for scanning transmission electron microscopes (STEM) has dramatically increased spatial image resolution for beam-stable materials, but it is the sample stability rather than the microscope that often limits the practical resolution of STEM images. To extract physical information from images of beam sensitive materials it is becoming clear that there is a critical dose/dose-rate below which the images can be interpreted as representative of the pristine material, while above it the observation is dominated by beam effects. Here we describe an experimental approach for sparse sampling in the STEM and in-painting image reconstruction in order to reduce the electron dose/dose-rate to the sample during imaging. By characterizing the induction limited rise-time and hysteresis in scan coils, we show that sparse line-hopping approach to scan randomization can be implemented that optimizes both the speed of the scan and the amount of the sample that needs to be illuminated by the beam. The dose and acquisition time for the sparse sampling is shown to be effectively decreased by factor of 5x relative to conventional acquisition, permitting imaging of beam sensitive materials to be obtained without changing the microscope operating parameters. As a result, the use of sparse line-hopping scan to acquire STEM images is demonstrated with atomic resolution aberration corrected Z-contrast images of CaCO 3 , a material that is traditionally difficult to image by TEM/STEM because of dose issues.

36 MATERIALS SCIENCE↗

Label-free quantum super-resolution imaging using entangled multi-mode squeezed light

Abstract In this study, we explore the theoretical application of entangled multi-mode squeezed light for label-free optical super-resolution imaging. By generating massively entangled multi-mode squeezed light through an array of balanced beam splitters, using a single-mode squeezed light input, we create a multi-mode quantum light state with exceptional entanglement and noise suppression below the shot noise level. This significantly reduces imaging measurement errors compared to classical coherent state light imaging when the same number of photons are used on the imaging sample. We demonstrate how to optimize the imaging system’s parameters to achieve the Heisenberg imaging error limit, taking into account the number of entangled modes and photons used. We also examine the effects of optical losses in the imaging system, necessitating adjustments to the optimized parameters based on the degree of optical loss. In practical applications, this new quantum imaging approach reduces the number of photons needed to achieve the same image quality by two orders of magnitude compared to classical imaging methods that use non-entangled, non-squeezed coherent state light.

Soh, Daniel (ORCID:0000000325625675)↗

Image registration for accurate electrode deformation analysis in operando microscopy of battery materials

Operando imaging techniques have become increasingly valuable in both battery research and manufacturing. However, the reliability of these methods can be compromised by instabilities in the imaging setup and operando cells, particularly when utilizing high-resolution imaging systems. The acquired imaging data often include features arising from both undesirable system vibrations and drift, as well as the scientifically relevant deformations occurring in the battery sample during cell operation. For meaningful analysis, it is crucial to distinguish and separately evaluate these two factors. To address these challenges, we employ a suite of advanced image-processing techniques. These include fast Fourier transform analysis in the frequency domain, power spectrum-based assessments for image quality, as well as rigid and non-rigid image-registration methods. These techniques allow us to identify and exclude blurred images, correct for displacements caused by motor vibrations and sample holder drift and, thus, prevent unwanted image artifacts from affecting subsequent analyses and interpretations. Additionally, we apply optical flow analysis to track the dynamic deformation of battery electrode materials during electrochemical cycling. This enables us to observe and quantify the evolving mechanical responses of the electrodes, offering deeper insights into battery degradation. Together, these methods ensure more accurate image analysis and enhance our understanding of the chemomechanical interplay in battery performance and longevity.

Sun, Tianxiao↗