Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Development and test of an IR camera for astronomical observation at the Palomar 200-in. observatory using the NICMOS II array

A NICMOS II array, a NIR (0.80 - 2.6 micron) imaging system, was integrated into the California Institute of Technology Palomar Observatory camera. The Palomar camera system which consists of six discrete subsystems including a focal plane, an electrical interface, data acquisition electronics, a dewar, dewar optics, and the software is described. The performance and calibration data for each subsystem are presented. Emphasis is placed on test data on the focal plane performance.

Bruce, Carl↗

Active figure maintenance control using an optical truss laser metrology system for a space-based far-IR segmented telescope

A two-stage active control approach was developed addressing the figure control problem for a spaceborne FIR telescope, the Precision Segmented Reflectors Focus Moderate Mission Telescope (FMMT). The first active control stage aligns the optical segments based on images; attention is here given to the second stage, active figure maintenance control system, which maintains the alignment of the optical elements between initializations to hold the mirror figure steady while obtaining data and fixes translational and rotational changes of the optical segments induced by long-term thermal drifts of the support structure. Errors are expected to be 10-100 microns at the nodes of the primary backup structure over the course of an orbit. An rms performance of 0.8 microns of wavefront error can be expected during the maintenance function based on specified nominal sensor noises, actuator accuracies, and system environments. A performance of less than 0.3 microns rms can be expected, based on advanced components.

Lau, Kenneth↗

Response of a piezoelectric pressure transducer to IR laser beam impingement

The non-pressure response of a PCB Model 113A transducer to a far infrared radiation impulse from a carbon dioxide laser was investigated. Incident radiation was applied both to the bare transducer diaphragm and to coated diaphragms. Coatings included two common ablative materials and a reflective gold coating. High-flux radiation impulses induced an immediate brief negative output followed by a longer-duration positive output. Both timing and amplitude of the responses will be discussed, and the effects of coatings will be compared. Bursts of blackbody radiation from a 1500 K source produced qualitatively similar responses.

Smith, William C.↗

Advanced Si IR detectors using molecular beam epitaxy

SiGe/Si heterojunction internal photoemission (HIP) long wavelength infrared (LWIR) detectors have been fabricated by MBE. The SiGe/Si HIP detector offers a tailorable spectral response in the long wavelength infrared regime by varying the SiGe/Si heterojunction barrier. Degenerately doped p(+) SiGe layers were grown using elemental boron, as the dopant source allows a low growth temperature. Good crystalline quality was achieved for boron-doped SiGe due to the reduced growth temperature. The dark current density of the boron-doped HIP detectors was found to be thermionic emission limited. HIP detectors with a 0.066 eV were fabricated and characterized using activation energy analysis, corresponding to a 18 micron cutoff wavelength. Photoresponse of the detectors at wavelengths ranging from 2 to 12 microns has been characterized with corresponding quantum efficiencies of 5 - 0.1 percent.

Lin, T. L.↗

Stratospheric N2O5, CH4, and N2O profiles from IR solar occultation spectra

Stratospheric volume mixing ratio profiles of N2O5, CH4, and N2O have been retrieved from a set of 0.052/cm resolution (FWHM) solar occultation spectra recorded at sunrise during a balloon flight from Aire sur l'Adour, France (44 N latitude) on 12 October 1990. The N2O5 results have been derived from measurements of the integrated absorption by the 1246/cm band. Assuming a total intensity of 4.32 x 10 exp -17 cm/molecule/sq cm independent of temperature, the retrieved N2O5 volume mixing ratios in ppbv, interpolated to 2 km height spacings, are 1.64 +/- 0.49 at 37.5 km, 1.92 +/- 0.56 at 35.5 km, 2.06 +/- 0.47 at 33.5 km, 1.95 +/- 0.42 at 31.5 km, 1.60 +/- 0.33 at 29.5 km, 1.26 +/- 0.28 at 27.5 km, and 0.85 +/- 0.20 at 25.5 km. Error bars indicate the estimated 1-sigma uncertainty including the error in the total band intensity. The retrieved profiles are compared with previous measurements and photochemical model results.

Camy-Peyret, C.↗

Calibration of the AVHRR visible and near IR channels using radiances measured over remote ocean areas

An inflight absolute calibration method has been adapted and applied to channel 1 of the AVHRR. The approach is based on AVHRR observations in channels 1, 2 and 4. A rigorous cloud screening is performed, based on the homogeneity of the data in channel 1 and 2 and on the temperature in channel 4. In a combined approach, the off-nadir view satellite count in channel 2 is used to detect the aerosol optical thickness and loading and the count of channel 1 is used to calibrate this channel, based on the predictable Rayleigh scattering component. Water vapor data are used, and the channels are intercalibrated using the ratio between channels 1 and 2 over the glint region.

Vermote, Eric F.↗

Development and testing of 11- and 24-inch hybrid motors under the joint government/industry IR&D program

Establishment of a test facility and associated 11-in.-diameter motor for hybrid propulsion technology development at NASA's George C. Marshall Space Flight Center is discussed in this paper. Results of twenty 11-in.-diameter motor tests with a UTF-29901 (60 percent polycyclopentadiene, 40 percent hydroxyl-terminated polybutadiene)/gaseous oxygen propellant system are presented. Tests at this scale have developed fuel regression correlations for comparison with results of yet-to-be-completed, 24-in.-diameter motor tests; demonstrated combustion efficiency levels in the 95 percent range for both single- and multiple-port grain configurations; have shown smooth and stable throttling characteristics over flight-type throttle ranges; and have begun to establish criteria for stable combustion in hybrid motors. The testing of 24-in. motors has not as yet been initiated and is not addressed.

Boardman, T. A.↗

Far-IR Fabry-Perot spectrometer for OH measurements

The Far Infrared Limb Observing Spectrometer (FILOS) is an instrument designed to measure chemical species in the upper atmosphere using limb emission in the FIR region of the spectrum. FILOS uses three Fabry-Perot etalons in series to obtain a resolution of 0.0017/cm near 100/cm (100 microns). It is compact and has low power and low data rate requirements so that it may be flown as an auxiliary balloon payload with larger instruments. FILOS has two 0.05/cm bandwidth channels which are currently tuned to a HCl line at 104.2/cm and a pair of OH lines at 101.3/cm. The instrument is described in further detail and results are presented from two recent balloon flights in which OH was measured as a function of time on one hour centers from sunrise to sunset.

Pickett, Herbert M.↗

AE 152 cascode readout for far-IR focal plane arrays

The Amber Engineering AE 152 readout is a 32-channel multiplexer built as part of the FIR focal plane array development effort for the Space Infrared Telescope Facility (SIRTF). The design of the device addresses a number of constraints peculiar to the operation of germanium photoconductors. In particular, the need for a very high level of bias stability is solved by a nonswitched operation of the first stage. Additionally, the readout was optimized for the detector capacitance expected of large bulk photoconductors (about 0.7 pF) and for the slow operating speeds anticipated for this astronomical application. Fabricated in a 1.25-micron C-MOS process, the circuit utilizes a cascode input stage to provide gain at the front end while avoiding the Miller effect. The AE 152 also includes an internal offset correction and a shift register multiplexer for the output. We present test data for this device at a variety of temperatures, and show read noises as low as 8 electrons at a temperature of 77 K.

Young, Erick T.↗

Implementation of a noise reduction circuit for spaceflight IR spectrometers

The paper discusses the implementation and analysis of a correlated triple sampling circuit using analog subtractor/integrators. The software and test setup for noise measurements are also described. The correlation circuitry is part of the signal chain for a 256-element InSb line array used in the Visible and Infrared Mapping Spectrometer. Using a focal-plane array (FPA) simulator, system noise measurements of 0.7 DN are obtained. A test setup for FPA/SPE (signal processing electronics) characterization along with noise measurements is demonstrated.

Ramirez, L.↗

Low background IR detector and detector array evaluations

A technology program has been underway at Ames since 1978 to develop and evaluate detectors and integrated detector arrays for low-background astronomical applications. The approach is to evaluate existing (less than 24 micron) array technology under low-background conditions, with the aim of adapting and optimizing existing devices. For longer wavelengths, where the technology is much less mature, development is sponsored and devices are evaluated, in both discrete and array formats, for eventual applications. The status of this program has been reported previously. We rely on industrial and university sources for the detectors. Typically, after a brief functionality check in the supplier's laboratory, we work with the device at Ames to characterize its low-background performance. In the case of promising arrays or detectors, we conduct ground-based telescope testing to face the problems associated with real applications. A list of devices tested at Ames is given. In the array category, accumulation-mode charge-injection-devices (AMCIDs) appear repeatedly; this reflects our recent experience with the 2 x 64 and 16 x 16 arrays. Results from the 1 x 16 CID and InSb CCD have been reported. The status of our tests of the discrete Ge:x detectors from Lawrence Berkeley Laboratory are described below. Tests of a 1 x 2 switched sample photoconductor array are just beginning. A 32-channel CMOS multiplexer has been tested at 10 K. Low-temperature silicon MOSFETs and germanium JFETs have also been tested, primarily at Ball Aerospace. This paper describes results to date on three elements of this program: AMCID array, discrete Ge:Ga detectors, and Ge JFET preamplifiers.

Goebel, J. H.↗

UCSD IR detector development programs

A diagram is presented for the UCSD low background infrared spot scanner. The spot scanner parameters are outlined. The testing that is planned for the charge injection device is outlined. The Aerojet linear 128 element array is also outlined.

Jones, B.↗

Development and testing of a superconducting link for an IR detector

The development and testing of a ceramic superconducting link for an infrared detector is summarized. Areas of study included the materials used, the electrical contacts, radiation and temperature cycling effects, aging, thermal conductivity, and computer models of an ideal link. Materials' samples were processed in a tube furnace at temperatures of 840 C to 865 C for periods up to 17 days and transition temperatures and critical current densities were recorded. The project achieved better quality high superconducting transition temperature material through improved processing and also achieved high quality electrical contacts. Studies on effects of electron irradiation, temperature cycling, and aging on superconducting properties indicate that the materials will be suitable for space applications. Various presentations and publications on the study's results are reported.

Caton, R.↗

Composition of the Martian aerosols through near-IR spectroscopy

Near-infrared spectroscopy is a powerful technique to study the composition of planetary surfaces, as the main minerals exhibit absorption bands in this spectral range. It gave important information on the mineralogy and petrology of Mars in the past twenty years although in this case it is well known that a large fraction of light is scattered by the airborne particles before reaching the surface. The measured signal is thus the sum of two different contributions that should be studied separately: One from the surface and one from the aerosols that depends on their density, size distribution and composition. Data from the ISM imaging spectrometer are used here to derive the aerosols spectrum. They consist in sets of spectra (from 0.76 to 3.16 microns) of approximately 3000 pixels approximately 25x25 sq km in size. The resulting spectrum exhibits both water-ice and clay mineral features superimposed on a scattering continuum.

Erard, Stephane↗

Predesign of diamond turned refractive/diffractive elements for IR objectives

Diffractive lenses have arrived. Literally hundreds of papers have been published and technology impact reports have been written about the exciting addition of a new tool for the lens designer. Sophisticated computer programs have been developed to aid in the optimization of these diffractive phase profiles for a wide variety of applications. Now, several fabrication methods are being pursued to produce these diffractive elements economically. The best known process is the etching of a multi-level relief grating, known as binary optics. This process uses sets of computer generated lithographic masks. Another, more recently developed method is Dry Photopolymer Embossing (DPE). This replication process uses master holograms. And now, diamond turning is being applied for the machining of these elements. Diamond turning is especially well suited for infrared optics. As any process has advantages and limitations, so has diamond turning. These advantages and limitations are discussed and general guidelines are presented to aid the designer and systems engineer in the project predesign stage.

Riedl, Max J.↗

Wavelength dependence of limb-darkening of Mars from visible and near-IR telescopic spectral imaging

We are investigating the photometric properties of Mars using Earthbased telescopic spectral imaging obtained during 1988. Each spatial pixel consists of 300 spectral channels from 0.44 to 1.02 microns, calibrated to radiance factor (r(sub F)) through a careful procedure involving standard star observations in 1988 and 1990. Calibrated data include 3 spectral images with solar phase angle (g) of 12 degrees and 4 images with g of 4 degrees. Pixels near the sub-Earth point have a spatial footprint of about 280 x 150 km. Preliminary work using Hapke photometric function reveals a dependence of both single-scattering albedo and roughness parameter on wavelength. The former is in agreement with observed spectra of the martian surface, but the latter is unexpected.

Pierazzo, E.↗

Surface-induced brightness temperature variations and their effects on detecting thin cirrus clouds using IR emission channels in the 8-12 micrometer region

A method for detecting cirrus clouds in terms of brightness temperature differences between narrow bands at 8, 11, and 12 mu m has been proposed by Ackerman et al. (1990). In this method, the variation of emissivity with wavelength for different surface targets was not taken into consideration. Based on state-of-the-art laboratory measurements of reflectance spectra of terrestrial materials by Salisbury and D'Aria (1992), we have found that the brightness temperature differences between the 8 and 11 mu m bands for soils, rocks and minerals, and dry vegetation can vary between approximately -8 K and +8 K due solely to surface emissivity variations. We conclude that although the method of Ackerman et al. is useful for detecting cirrus clouds over areas covered by green vegetation, water, and ice, it is less effective for detecting cirrus clouds over areas covered by bare soils, rocks and minerals, and dry vegetation. In addition, we recommend that in future the variation of surface emissivity with wavelength should be taken into account in algorithms for retrieving surface temperatures and low-level atmospheric temperature and water vapor profiles.

Gao, Bo-Cai↗

UV extinction and IR emission in diffuse H2 regions

During this period, much work was spent in an attempt to use theoretical UV line indices as a basis for spectral calibration of the program stars. Five line indices are shown as functions of effective temperature and log g, calculated with the spectral synthesis programs of Kurucz. Open stars and circles are observed values from Fanelli et al., using the spectral class-effective temperature calibration of Schmidt-Kaler. We conclude that these line indices may be used to determine an effective stellar temperature, but with uncertainties of approximately a few thousand degrees. Also, for the hotter stars, theoretical line opacities are systematically low compared to observations. We have also found that Kurucz's new models appear to represent hot stars very well, even at far-UV wavelengths. This is shown in an example where two spectra of mu Col (spectral class 09.5 V) are compared to a synthetic spectrum for T(sub eff) = 33,000 K, log g = 4.0. Also shown (uppermost curve) is an empirical estimate of the intrinsic flux distribution for 09.5 V stars from Papaj, Wegner, and Krelowski.

Aannestad, Per A.↗