Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “INTEGRAL DOSES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Overview of the SNS Target System Testing and Initial Beam Operation Experience

The Spallation Neutron Source (SNS) construction project has been completed including initial beam operation with the mercury target, moderators and associated systems. The project was initiated in 1999, with groundbreaking in December of 1999. Final integrated system testing for the mercury target, cryogenic moderators, shutter systems, water and other utility systems and all control and safety systems were completed in April 2006 and first beam on target delivered April 28, 2006. This paper will give an overview of the system testing conducted in preparation for beam operation and initial operating experience with low power beams. One area of testing was extensive remote handling testing in the Target Service Bay to demonstrate all key operations associated with the target and mercury loop. Many improvements were implemented as a result of this experience. Another set of tests involved bringing the supercritical cryogenic moderator systems on line. Again, lesions learned here resulted in system changes. Testing of the four water loops was very time consuming because of the complexity of the systems and many instrumentation issues had to be resolved. A temporary phosphor view screen was installed on the front of the target which has been extremely useful in evaluating the beam profile on the target. Initial profile results will be presented. Target System performance for initial beam operation will be discussed. In general, all systems performed well with excellent availability. There were some unexpected findings. For example, xenon spallation gas products are believed to have deposited on a downstream gold amalgamation bed designed to remove mercury vapor and increased the local dose rate. A summary of findings and plans for ramping up in power will be given.

Spallation↗

SU-F-J-150: Development of An End-To-End Chain Test for the First-In-Man MR-Guided Treatments with the MRI Linear Accelerator by Using the Alderson Phantom

The Alderson phantom is a human shaped quality assurance tool that has been used for over 30 years in radiotherapy. The phantom can provide integrated tests of the entire chain of treatment planning and delivery. The purpose of this research was to investigate if this phantom can be used to chain test a treatment on the MRI linear accelerator (MRL) which is currently being developed at the UMC Utrecht, in collaboration with Elekta and Philips. The latter was demonstrated by chain testing the future First-in-Man treatments with this system.An Alderson phantom was used to chain test an entire treatment with the MRL. First, a CT was acquired of the phantom with additional markers that are both visible on MR and CT. A treatment plan for treating bone metastases in the sacrum was made. The phantom was consecutively placed in the MRL. For MRI imaging, an 3D volume was acquired. The initially developed treatment plan was then simulated on the new MRI dataset. For simulation, both the MR and CT data was used by registering them together. Before treatment delivery a MV image was acquired and compared with a DRR that was calculated form the MR/CT registration data. Finally, the treatment was delivered. Figure 1 shows both the T1 weighted MR-image of the phantom and the CT that was registered to the MR image. Figure 2 shows both the calculated and measured MV image that was acquired by the MV panel. Figure 3 shows the dose distribution that was simulated. The total elapsed time for the entire procedure excluding irradiation was 13:35 minutes.The Alderson Phantom yields sufficient MR contrast and can be used for full MR guided radiotherapy treatment chain testing. As a result, we are able to perform an end-to-end chain test of the future First-in-Man treatments.

60 APPLIED LIFE SCIENCES↗

Nuclear Data Performance Testing Using Sensitive, but Less Frequently Used ICSBEP Benchmarks

The International Criticality Safety Benchmark Evaluation Project (ICSBEP) has published the International Handbook of Evaluated Criticality Safety Benchmark Experiments annually since 1995. The Handbook now spans over 51,000 pages with benchmark specifications for 4,283 critical, near critical, or subcritical configurations; 24 criticality alarm placement/shielding configurations with multiple dose points for each; and 200 configurations that have been categorized as fundamental physics measurements relevant to criticality safety applications. Benchmark data in the ICSBEP Handbook were originally intended for validation of criticality safety methods and data; however, the benchmark specifications are now used extensively for nuclear data testing. There are several, less frequently used benchmarks within the Handbook that are very sensitive to thorium and certain key structural and moderating materials. Calculated results for many of those benchmarks using modern nuclear data libraries suggest there is still room for improvement. These and other highly sensitive, but rarely quoted benchmarks are highlighted and data testing results provided using the Monte Carlo N-Particle Version 5 (MCNP5) code and continuous energy ENDF/B-V, VI.8, and VII.0, JEFF-3.1, and JENDL-3.3 nuclear data libraries.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron yields from 155 MeV/nucleon carbon and helium stopping in aluminum

Neutron fluences have been measured from 155 MeV/nucleon 4He and 12C ions stopping in an Al target at laboratory angles between 10 and 160 deg. The resultant spectra were integrated over angle and energy above 10 MeV to produce total neutron yields. Comparison of the two systems shows that approximately two times as many neutrons are produced from 155 MeV/nucleon 4He stopping in Al and 155 MeV/nucleon 12C stopping in Al. Using an energy-dependent geometric cross-section formula to calculate the expected number of primary nuclear interactions shows that the 12C + Al system has, within uncertainties, the same number of neutrons per interaction (0.99 +/- 0.03) as does the 4He + Al system (1.02 +/- 0.04), despite the fact that 12C has three times as many neutrons as does 4He. Energy and angular distributions for both systems are also reported. No major differences can be seen between the two systems in those distributions, except for the overall magnitude. Where possible, the 4He + Al spectra are compared with previously measured spectra from 160 and 177.5 MeV/nucleon 4He interactions in a variety of stopping targets. The reported spectra are consistent with previously measured spectra. The data were acquired to provide data applicable to problems dealing with the determination of the radiation risk to humans engaged in long-term missions in space; however, the data are also of interest for issues related to the determination of the radiation environment in high-altitude flight, with shielding at high-energy heavy-ion accelerators and with doses delivered outside tumor sites treated with high-energy hadronic beams.

NASA Discipline Radiation Health↗

WE-E-17A-07: Patient-Specific Mathematical Neuro-Oncology: Biologically-Informed Radiation Therapy and Imaging Physics

Purpose: To demonstrate a method of generating patient-specific, biologically-guided radiation therapy (RT) plans and to quantify and predict response to RT in glioblastoma. We investigate the biological correlates and imaging physics driving T2-MRI based response to radiation therapy using an MRI simulator. Methods: We have integrated a patient-specific biomathematical model of glioblastoma proliferation, invasion and radiotherapy with a multiobjective evolutionary algorithm for intensity-modulated RT optimization to construct individualized, biologically-guided plans. Patient-individualized simulations of the standard-of-care and optimized plans are compared in terms of several biological metrics quantified on MRI. An extension of the PI model is used to investigate the role of angiogenesis and its correlates in glioma response to therapy with the Proliferation-Invasion-Hypoxia- Necrosis-Angiogenesis model (PIHNA). The PIHNA model is used with a brain tissue phantom to predict tumor-induced vasogenic edema, tumor and tissue density that is used in a multi-compartmental MRI signal equation for generation of simulated T2- weighted MRIs. Results: Applying a novel metric of treatment response (Days Gained) to the patient-individualized simulation results predicted that the optimized RT plans would have a significant impact on delaying tumor progression, with Days Gained increases from 21% to 105%. For the T2- MRI simulations, initial validation tests compared average simulated T2 values for white matter, tumor, and peripheral edema to values cited in the literature. Simulated results closely match the characteristic T2 value for each tissue. Conclusion: Patient-individualized simulations using the combination of a biomathematical model with an optimization algorithm for RT generated biologically-guided doses that decreased normal tissue dose and increased therapeutic ratio with the potential to improve survival outcomes for treatment of glioblastoma. Simulated T2-MRI is shown to be consistent with known physics of MRI and can be used to further investigate biological drivers of imaging-based response to RT.

60 APPLIED LIFE SCIENCES↗

Effect of Space Radiation on TES Detectors Performance

The Athena mission and its X-IFU instrument (X-ray Integral Field Unit) will be positioned at the Sun-Earth Lagrangian point L1, where it will be subject to solar wind (low flux plasma of 95% protons and 5% alpha particles) with energy below 0.1 MeV, and to galactic cosmic rays and solar flares (energetic protons, alpha particles, and electrons) with energies up to hundreds of MeV for protons and the GeV for heavier ions. Some of these particles will go through the satellite and hit the focal plane assembly and hence the detectors. These detectors will be TES (Transition-edge sensor) microcalorimeters, flown for the first time in such an environment. In order to ensure the performance of this type of detectors throughout the duration of such mission, it is critical to study the impact of the radiation on their behavior. Indeed, although a lot of reference material exist for semiconductor detectors such as CCDs, little is currently known about the impact of radiation on TES detectors. These energetic events could cause local heating or damage to the detectors and affect their performance. In this work, we describe how we designed a test campaign to assess the impact of L1 radiation on TES detectors for Athena/X-IFU-like missions and present the results of the tests. Analyses includes assessing changes in the pulse shapes and energy resolution of the detectors measured at 55 mK after several radiation dose steps performed at 4 K.

Sophie Beaumont↗

Ambient Monitoring for Sinclair and Dyes Inlets, Puget Sound, Washington: Chemical Analyses for 2012 Regional Mussel Watch

Under the Project ENVVEST Final Project Agreement, the Puget Sound Naval Shipyard & Intermediate Maintenance Facility (PSNS&IMF), Environmental Protection Agency (EPA), Washington State Department of Ecology (Ecology), and local stakeholders have worked collaboratively to improve the environmental quality of Sinclair and Dyes Inlets. A regional mussel monitoring program began in 2010 to assess the status and trend of ecological resources, assess the effectiveness of cleanup and pollution control measures, and determine if discharges from all sources are protective of beneficial uses including aquatic life. The program collected indigenous mussels to represent a time-integrated measure of bioavailable metals and organic chemicals present in the water column. This document supplements the 2010 indigenous mussel data with 2012 data to provide two years of data on the chemical residue of mussels present in the inter-tidal regions of Sinclair Inlet, Dyes Inlet, Port Orchard Passage, Rich Passage, Agate Passage, Liberty Bay, and Keyport Lagoon. The 2012 data set added one station at PSNS&IMF and one market samples from Penn Cove. Indigenous mussels were collected from a small boat and/or from along the shoreline, measured, composited, and analyzed for percent lipids, percent moisture, stable isotopes of carbon and nitrogen, and a suite of trace metals and organic contaminants. The trace metals included silver (Ag), arsenic (As), cadmium (Cd), copper (Cu), mercury (Hg), lead (Pb), and zinc (Zn). The organic contaminants included the list of NOAA Status and Trends 20 polychlorinated biphenyls (PCB) congeners and suite of parent and methylated polycyclic aromatic hydrocarbons (PAHs). The average lengths between the 2010 and 2012 data were generally less than 30% relative percent difference (RPD). Generally, the metals concentrations were lower in 2012 than 2010 with some notable exceptions in Sinclair Inlet and Rich Passage where increases in Ag, Hg, Pb, Cu, and Zn exceeded an RPD of 50% between years. However, they did not exceed the bioaccumulation critical values or the critical body residues corresponding to the no observed effect dose (NOED) and the lowest observed effect dose (LOED) with one exception. The Cd concentrations exceeded the NOED and LOED for the Manchester Lab Pier and the Pike Place Market samples. For the PAHs and PCB, the 2012 data were generally lower than 2010 and some cases significantly lower for PAHs and none of the available invertebrate benchmarks were exceeded.

Brandenberger, Jill M.↗

SU-E-P-21: Impact of MLC Position Errors On Simultaneous Integrated Boost Intensity-Modulated Radiotherapy for Nasopharyngeal Carcinoma

Purpose: To investigate the impact of MLC position errors on simultaneous integrated boost intensity-modulated radiotherapy (SIB-IMRT) for patients with nasopharyngeal carcinoma. Methods: To compare the dosimetric differences between the simulated plans and the clinical plans, ten patients with locally advanced NPC treated with SIB-IMRT were enrolled in this study. All plans were calculated with an inverse planning system (Pinnacle3, Philips Medical System{sub )}. Random errors −2mm to 2mm{sub )},shift errors{sub (} 2mm,1mm and 0.5mm) and systematic extension/ contraction errors (±2mm, ±1mm and ±0.5mm) of the MLC leaf position were introduced respectively into the original plans to create the simulated plans. Dosimetry factors were compared between the original and the simulated plans. Results: The dosimetric impact of the random and system shift errors of MLC position was insignificant within 2mm, the maximum changes in D95% of PGTV,PTV1,PTV2 were-0.92±0.51%,1.00±0.24% and 0.62±0.17%, the maximum changes in the D0.1cc of spinal cord and brainstem were 1.90±2.80% and −1.78±1.42%, the maximum changes in the Dmean of parotids were1.36±1.23% and −2.25±2.04%.However,the impact of MLC extension or contraction errors was found significant. For 2mm leaf extension errors, the average changes in D95% of PGTV,PTV1,PTV2 were 4.31±0.67%,4.29±0.65% and 4.79±0.82%, the averaged value of the D0.1cc to spinal cord and brainstem were increased by 7.39±5.25% and 6.32±2.28%,the averaged value of the mean dose to left and right parotid were increased by 12.75±2.02%,13.39±2.17% respectively. Conclusion: The dosimetric effect was insignificant for random MLC leaf position errors up to 2mm. There was a high sensitivity to dose distribution for MLC extension or contraction errors.We should pay attention to the anatomic changes in target organs and anatomical structures during the course,individual radiotherapy was recommended to ensure adaptive doses.

60 APPLIED LIFE SCIENCES↗

Weekly Low-Dose Docetaxel-Based Chemoradiotherapy for Locally Advanced Oropharyngeal or Hypopharyngeal Carcinoma: A Retrospective, Single-Institution Study

Purpose: To retrospectively assess the efficacy, toxicity, and prognostic factors of weekly low-dose docetaxel-based chemoradiotherapy for Stage III/IV oropharyngeal or hypopharyngeal carcinoma. Methods and Materials: Between 2001 and 2005, 72 consecutive patients with locally advanced oropharyngeal or hypopharyngeal carcinoma were treated with concurrent chemoradiotherapy (CCR; radiation at 60 Gy plus weekly docetaxel [10 mg/m{sup 2}]). Thirty of these patients also received neoadjuvant chemotherapy (NAC; docetaxel, cisplatin, and 5-fluorouracil) before concurrent chemoradiotherapy. Survival was calculated according to the Kaplan-Meier method. The prognostic factors were evaluated by univariate and multivariate analyses. Results: The median follow-up was 33 months, with overall survival, disease-free survival, and locoregional control rates at 3 years of 59%, 45%, and 52%, respectively. Thirty-six patients (50%) experienced more than one Grade 3 to 4 acute toxicity. Grade 3 mucositis occurred in 32 patients (44%), Grade 4 laryngeal edema in 1 (1%). Grade >=3 severe hematologic toxicity was observed in only 2 patients (3%). Grade 3 dysphagia occurred as a late complication in 2 patients (3%). Multivariate analyses identified age, T stage, hemoglobin level, and completion of weekly docetaxel, but not NAC, as significant factors determining disease-free survival. Conclusions: Docetaxel is an active agent used in both concurrent and sequential chemoradiotherapy regimens. Mucositis was the major acute toxicity, but this was well tolerated in most subjects. Anemia was the most significant prognostic factor determining survival. Further studies are warranted to investigate the optimal protocol for integrating docetaxel into first-line chemoradiotherapy regimens, as well as the potential additive impact of NAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Concept of Operations for Advanced Reactor Spent Nuclear Fuel Management

This presentation presents a preliminary description of a concept of operations to incorporate advanced-reactor spent nuclear fuel (SNF) into an integrated waste-management system (IWMS). The evaluation includes SNF from four advanced-reactor concepts with the following fuel types: (1) small modular reactors using oxide fuels, (2) tristructural-isotropic (TRISO) fuels, (3) metallic fuels, and (4) fuel salts. To provide context for the proposed concept of operations for advanced reactors, a comparison is made with traditional light-water reactors (LWRs) to identify potential gaps in the IWMS. The technical differences between advanced reactors and LWRs are assessed to determine the feasibility of managing advanced-reactor waste streams using existing operations and technology. This presentation emphasizes fuel types from Advanced Reactor Demonstration Program reactors: Xe 100, which uses TRISO fuel and Natrium, with its metallic fuels while also analyzing management options for molten-salt reactors and advanced light-water reactors (ALWRs). Understanding the storage, transportation, and disposal requirements of SNF is dependent on both the quantity and characteristics of the SNF generated by nuclear reactors. This presentation provides a high level overview, comparing the anticipated concept of operations for different SNFs from advanced reactors. The IWMS includes at-reactor storage, transportation, potential off-site storage, potential treatment, and disposition. To assess the potential effect of advanced-reactor concept of operations on the IWMS, estimates were made for fuel characteristics that contribute to storage, transportation, disposal, and possible treatment of advanced-reactor SNF. These include canister heat load, dose rates, and criticality-control limits, which are important for determining the condition and configuration of the advanced reactor SNF. At-reactor storage of LWR SNF traditionally involves a spent-fuel pool (SFP) before transfer to an independent spent-fuel storage installation. However, some advanced-reactor concepts, particularly those using TRISO and salt fuels, do not anticipate the use of an SFP. This difference in at-reactor storage could impact the IWMS. Additionally, transportation of advanced-reactor SNF may include additional processes tied to potential off gassing, and transportation of microreactor SNF may occur within the reactor vessel. Some advanced-reactor SNF could also undergo treatment to meet requirements of an acceptable waste form for disposition, and the treatment location will be a major contributor to efficiently performing IWMS responsibilities. Moreover, the quantity of SNF generated is an important consideration for IWMS because it could affect the size of the transportation fleet and potential off-site storage requirements. Additionally, volume and heat load are the primary drivers for SNF disposition. This presentation compares potential packaging options for advanced reactor SNF with traditional LWR packaging to provide a high-level comparison for the needs of the IWMS for advanced-reactor SNF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

WE-FG-BRA-07: Theranostic Nanoparticles Improve Clinical MR-Guided Radiation Therapy

Purpose: MR-guided radiation therapy is a current and emerging clinical reality. We have designed and tested a silica-based gadolinium chelates nanoparticle (AGuIX) for integration with MR-guided radiation therapy. The AGuIX nanoparticles used in this study are a dual-modality probe with radiosensitization properties and better MRI contrast than current FDA-approved gadolinium chelates. In advance of an approved Phase I clinical trial, we report on the efficacy and safety in multiple animal models and clinically relevant radiation conditions. By modeling our study on current clinic workflows, we show compatibility with modern patient care, thus heightening the translational significance of this research. Methods: The dual imaging and therapy functionality of AGuIX was investigated in mice with clinical radiation beams while safety was evaluated in mice, and nonhuman primates after systemic injection of 0.25 mg/g of nanoparticles. MRI/ICP-MS were used to measure tumor uptake and biodistribution. Due to their small size (2–3 nm), AGuIX have good renal clearance (t1/2=19min). We performed in vitro cell uptake quantification and radiosensitization studies (clonogenic assays and DNA damage quantification). In vivo radiation therapy studies were performed with both 6MV and 6MV-FFF clinical radiation beams. Histology was performed to measure the increase in DNA damage in the tumor and to evaluate the toxicity in healthy tissues. Results: In vitro and in vivo results demonstrate statistically significant increase (P < 0.01) in DNA damage, tumor growth supression and survival (+100 days) compared to radiation alone. Negligible toxicity was observed in all of the animal models. The combination of 6MV-FFF/AGuIX demonstrated a substantial dose enhancement compared to 6MV/AGuIX (DEF = 1.36 vs. 1.22) due to the higher proportion of low energy photons. Conclusion: With demonstrated efficacy and negligible toxicity in mice and non-human primates, AGuIX is a biocompatible nanoplatform with strong translational potential for MR-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

HDG-1 Experiment Irradiation Monitoring Data Qualification Final Report

SUMMARY The U.S. Department of Energy (DOE) Advanced Reactor Technologies (ART) Graphite Research and Development (GRD) Program is conducting a series of six experiments to quantify the effects of irradiation on nuclear-grade graphite. This report documents the qualification of irradiation monitoring data for the fifth experiment, High Dose Graphite-1 (HDG-1). Qualified monitoring data are required by the ART program to support the design and licensing of the first high-temperature reactor (HTR) nuclear plant. Data are classified as Qualified if they meet the usage requirements described in the experiment planning and quality assurance (QA) documents, Failed if they do not meet those requirements and provide no usable information, or Trend if they do not fully meet all requirements but still provide useful information subject to an assessment of how any deficiencies may affect a particular use of the data. HDG-1 irradiation began with Advanced Test Reactor (ATR) Cycle 168B on August 24, 2020, and concluded after Cycle 173C on January 27, 2025. The HDG-1 capsule was removed from the reactor core twice—during core internal change (CIC) Cycle 170A and powered axial locator mechanism (PALM) Cycle 172A—to prevent overheating of the graphite specimens during high-power PALM cycles. The capsule was therefore irradiated during a total of seven normal ATR cycles: 168B, 169A, 171A, 171B, 173A, 173B, and 173C. Irradiation monitoring data evaluated in this report include thermocouple (TC) temperature, gas flow rate, gas moisture, gas pressure, specimen load, and graphite stack displacement. Temperature. A total of 14,508,065 TC temperature records were captured. Of these, 13,901,785 (95.8%) are Qualified and 606,280 (4.2%) are Failed. The principal source of failed temperature data was the instrument failure of TC-9 (Zone 2) on June 24, 2024, and TC-10 (Zone 1) on July 5, 2024, near the end of Cycle 173A, which resulted in 595,554 Failed readings. An additional 379 missing values and 10,347 slightly negative values from TC-13 during ATR outages are also Failed. Neither TC-9 nor TC-10 was used as a temperature-control TC, and their failures did not compromise capsule condition monitoring. Correlation analysis of all 13 TCs found no evidence of virtual junction formation. Control chart analysis revealed clear downward drift of approximately 80°C for TC-6 (Zone 3) relative to other stable TCs, and possible downward drift of approximately 60°C for TC-13 relative to the Zone 5 control TC (TC-1), though TC-13 remained consistent with the Zone 2 control TC (TC-12). Gas flow. A total of 20,088,090 gas flow rate records were captured. Of these, 19,941,463 (99.3%) are Qualified and 146,627 (0.7%) are Failed due to missing values. All argon, helium, and total gas flow data were within expected ranges throughout the irradiation. Gas moisture. A total of 1,116,005 outlet gas moisture values were captured. Of these, 1,101,421 (98.7%) are Qualified and 14,584 (1.3%) are Failed, comprising 14,556 out-of-range values and 28 missing values. The out-of-range moisture values exceeded 22,000 ppmv for approximately 1 week at the beginning of Cycle 173A, when accumulated moisture evaporated after the capsule was retrieved from water storage during PALM Cycle 172A and reinserted into the east flux trap. Moisture levels returned to below 25 ppmv for the remaining three cycles, and the transient high-moisture event did not affect the integrity of specimen irradiation. Gas pressure. A total of 7,812,035 gas pressure values were captured. Of these, 6,642,048 (85.0%) are Qualified and 1,169,987 (15.0%) outlet pressure values are Failed, comprising 718,537 zero outlet pressure values due to sensor failure from Cycle 168B through Cycle 171B, 54,550 missing values, and 396,900 too-low outlet pressure values, ranging from 1.1 to 1.6 psia after sensor replacement during Cycle 173A. Load. A total of 6,696,030 load values were captured. Of these, 6,694,580 (99.98%) are Qualified and 1,450 (0.02%) are Failed due to missing values. Applied loads to the six specimen stacks were stable throughout the irradiation. Stack displacement. A total of 6,696,030 displacement values were captured. Of these, 5,713,297 (85.32%) are Qualified and 3,781 (0.06%) are Failed due to missing values. Stack displacement increased consistently throughout the irradiation, reaching approximately 3.08 in. for Channels 5 and 6 by the end of irradiation. 978,952 (14.62%) substantially elevated displacements observed for Channel 6 beginning in Cycle 171A and for Channel 5 beginning in Cycle 173A are assigned Trend status. Raising pressure. A total of 1,115,999 raising pressure values were captured. Of these, 1,115,430 (99.95%) are Qualified and 569 (0.05%) are Failed due to missing values. Ram pressure. A total of 6,696,030 ram pressure values were captured. Of these, 6,692,249 (99.95%) are Qualified and 3,484 (0.05%) are Failed due to missing values. Stack raising was perf

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Biocompatibility, Inflammatory Response, and Recannalization Characteristics of Nonradioactive Resin Microspheres: Histological Findings

Intra-arterial radiotherapy with yttrium-90 microspheres (radioembolization) is a therapeutic procedure exclusively applied to the liver that allows the direct delivery of high-dose radiation to liver tumors, by means of endovascular catheters, selectively placed within the tumor vasculature. The aim of the study was to describe the distribution of spheres within the precapillaries, inflammatory response, and recannalization characteristics after embolization with nonradioactive resin microspheres in the kidney and liver. We performed a partial embolization of the liver and kidney vessels in nine white pigs. The left renal and left hepatic arteries were catheterized and filled with nonradioactive resin microspheres. Embolization was defined as the initiation of near-stasis of blood flow, rather than total occlusion of the vessels. The hepatic circulation was not isolated so that the effects of reflux of microspheres into stomach could be observed. Animals were sacrificed at 48 h, 4 weeks, and 8 weeks, and tissue samples from the kidney, liver, lung, and stomach evaluated. Microscopic evaluation revealed clusters of 10-30 microspheres (15-30 {mu}m in diameter) in the small vessels of the kidney (the arciform arteries, vasa recti, and glomerular afferent vessels) and liver. Aggregates were associated with focal ischemia and mild vascular wall damage. Occlusion of the small vessels was associated with a mild perivascular inflammatory reaction. After filling of the left hepatic artery with microspheres, there was some evidence of arteriovenous shunting into the lungs, and one case of cholecystitis and one case of marked gastritis and ulceration at the site of arterial occlusion due to the presence of clusters of microspheres. Beyond 48 h, microspheres were progressively integrated into the vascular wall by phagocytosis and the lumen recannalized. Eight-week evaluation found that the perivascular inflammatory reaction was mild. Liver cell damage, bile duct injury, and portal space fibrosis were not observed. In conclusion, resin microspheres (15-30 {mu}m diameter) trigger virtually no inflammatory response in target tissues (liver and kidney). Clusters rather than individual microspheres were associated with a mild to moderate perivascular inflammatory reaction. There was no evidence of either a prolonged inflammatory reaction or fibrosis in the liver parenchyma following recannalization.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Integrating static PRA information with risk informed safety margin characterization (RISMC) simulation methods

The overall objective of the project was to develop a computationally feasible and user-friendly mechanized process to integrate traditional probabilistic risk assessment (PRA) and dynamic PRA (DPRA) results. Starting with the systematic identification of items in an existing PRA that need dynamic augmentation, the project used a generic 4-loop pressurized reactor (PWR) and 3-loop PWR as example plants. Station blackout (SBO) and large break loss of coolant accident SBLOCA) were selected as the example initiating events. Using the traditional event-tree (ET)/fault-tree (FT) methodology augmented by dynamic evet tree approach, the potential consequences of the initiating events were simulated with RELAP-3D and MELCOR/RASCAL codes to cover Level 1 through Level 3 of PRA. RAVEN and ADAPT software were used to generate Level 1 simulations with RELAP-3D and Level 2/3 simulations with MELCOR (Level 2)/RASCAL (Level 3), respectively. Example branching conditions (BCs) for SBO included AC power recovery time, valve repair failure time, reactor coolant pump leak time/break size and emergency power supply duration to a total of 9. Example BCs for LOCA included off-site power recovery time, diesel generator power recovery time, auxiliary feed water system operation time, safety relief valve failure to open upon demand, reactor coolant pump seal break time and size to a total of 21. Each RELAP-3D simulation (9,587 scenarios) was labelled OK or Core Damage based on the maximum allowed peak clad temperature (2,100oF). Each MELCOR simulation (4610 scenarios) was labeled as Bin over 10rem or Bin 0-10rem based on the dose at the site boundary. The scenarios were clustered based on the criteria above using the mean shift methodology. Classical PRA (CPRA) and DPRA results were compared to identify the ET sequences that need DPRA augmentation. Several approaches were proposed for the incorporation of these sequences into CPRA using clustering with the mean shift methodology, restructuring the CPRA ETs by adding new BCs/sequences, and using the concept of a limit surface. Procedures for decision making regarding the possible consequences of an initiating event (e.g. core damage or not, site evacuation or not) were developed using a convolutional neural network (CNN), a recurrent neural network (RNN) and a transformer neural network (TNN). The project has led to two PhD degrees, three archival journal papers and five refereed conference proceedings.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Irradiation at Different Fetal Stages Results in Different Translocation Frequencies in Adult Mouse Thyroid Cells

While it is generally believed that fetuses are at high risk of developing cancers, including leukemia, after low doses of radiation, it has been reported that atomic bomb survivors exposed in utero did not show a dose response for translocations in blood T lymphocytes when they were examined at approximately 40 years of age. Subsequent mouse studies confirmed that animals irradiated during the fetal stage did not show evidence of radiation effects in lymphocytes and bone marrow cells when they were examined after reaching adulthood. However, in a study of rat mammary epithelial cells, radiation effects were clearly observed after fetal irradiation. These results indicate that the fate of chromosome aberrations induced in a fetus could vary among different tissues. Here we report on translocation frequencies in mouse thyroid cells, which were irradiated at different stages of fetal development. Cytogenetic examination was then conducted using fluorescence in situ hybridization (FISH) painting of chromosomes 1 and 3. Adult mice, 2 Gy X-ray irradiated at 15.5-day-old fetuses (E15.5), showed a higher translocation frequency (30/1,155 or 25.3 x 10 -3 ) than nonirradiated adult controls (0/1,007 or 0.1 x 10 -3 ), and was near that experienced by irradiated mothers and non-pregnant adult females (43/1,244 or 33.7 x 10 -3 ). These results are consistent with those seen in rat mammary cells. However, when fetuses were irradiated at an earlier stage of development (E6.5) before thyroid organogenesis, the resulting observed translocation frequency was much lower (3/502 or 5.8 x 10 -3 ) than that in E15.5 mice. These results suggest that after fetal irradiation, tissue stem cells record radiation effects primarily when the exposure occurs in cells that have been integrated into tissue. Embryonic stem cells that have been damaged prior to integration into the niche may undergo negative selection due to apoptosis, mitotic death or stem cell-niche cell interactions. The implications of these results in interpreting cancer risks after fetal irradiation are also discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Nested Pebble Bed Blanket (NesPeB)

Recent advances in magnetic confinement fusion technology have attracted billions of dollars of investments in startups from venture capitals and corporations, resulting in the development of devices aiming to demonstrate net energy gain in a self-heated burning plasma, such as SPARC (under construction) and others. However, future fusion power plants must operate in regimes that will require technologies far beyond current experience. According to a National Academies of Science, Engineering, and Medicine report, to have nuclear fusion power plants contributing in a timely manner to the planned reduction of atmospheric carbon dioxide, a pilot plant should be built by 2035, and it should demonstrate fusion power production and the performance of the tritium fuel system (requiring a high enough tritium breeding) by 2040. A recognized key technology gap by [26] is the fusion first wall and blanket since no current blanket concept is considered satisfactory or has been built and proven. The first wall and blanket in magnetic fusion reactors form a vital and complex system, as it must satisfy different functions such as power extraction, tritium breeding, plasma containment, radiation shielding, and safety. The list of design requirements is even longer: high enough tritium production for fusion self-sufficiency, low material activation, decay heat and shutdown dose rates, high thermal efficiency, high-capacity factor, high magnets-divertor-vacuum vessel-first wall life, low corrosion, low cost, and intrinsically safe (requiring minimal licensing). Despite fifty-plus years of research, the first wall and blanket concepts proposed suffer from fundamental technical problems and immaturity (TRL=2-3) that jeopardize the timely delivery of a commercial fusion power plant. A fusion first-wall blanket has never been built nor tested, and a "winning", practical functioning design requires enough engineering margins (high enough tritium breeding considering the uncertainty, etc.), manufacturing simplicity, ease of continuous operation, maintenance, and low cost. A new, groundbreaking blanket concept called "Nested Pebble Bed Blanket" (NesPeB) was developed at ORNL under the successful ARPA-E GAMOW FERMI project (patent application allowed by the USPTO). The NesPeB blanket concept addresses current blanket concepts' shortcomings and technical immaturity, paving the way for accelerated delivery of fusion power plants. NesPeB is based on nested pebbles, which are binary-sized lithium-ceramic pebbles enclosed in "Beryllide" perforated and coated spherical shells, which are also binary-sized, stacked on top of each other, forming a "bed" and cooled by Nitrogen gas also "sweeping" the Helium and Tritium generated by the neutron irradiation of Lithium; the vacuum vessel plasma facing material is Molybdenum-96 and -97 with the first wall cooled by Helium while the divertor armor is made of Tungsten. The simulations of the NesPeB blanket using Fusion Reactors Models Integrator (FERMI) are encouraging as they estimate a tritium breeding ratio (TBR) greater than 1.2 using natural Lithium, acceptable pressure drop, and excellent heat transfer properties. Furthermore, the NesPeB blanket is not limited by magneto-hydro-dynamics (MHD) effects, is designed for online refueling, relies on existing tritium extraction technologies, has a simple construction, and limits the corrosion and chemical reactivity problems. NesPeB has the potential to be transformational and disruptive since it can solve all the main, challenging technical problems of fusion device blankets and accelerate a pilot plant delivery for 10 or more years.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Oak Ridge Reservation Annual Site Environmental Report for 2009

The Oak Ridge Reservation Annual Site Environmental Report is prepared annually and presents summary environmental data to (1) characterize environmental performance, (2) summarize environmental occurrences reported during the year, (3) confirm compliance with environmental standards and requirements, and (4) highlight significant program activities. The report fulfills the requirement contained in DOE Order 231.1A, Environment, Safety and Health Reporting (DOE 2004) that an integrated annual site environmental report be prepared. The results summarized in this report are based on data collected prior to and through 2009. This report is not intended to nor does it present the results of all environmental monitoring associated with the ORR. Data collected for other site and regulatory purposes, such as environmental restoration/remedial investigation reports, waste management characterization sampling data, and environmental permit compliance data, are presented in other documents that have been prepared in accordance with applicable DOE guidance and/or laws and are referenced herein as appropriate. Appendix A to this report identifies corrections for the 2008 report. Appendix B contains a glossary of technical terms that may be useful for understanding the terminology used in this document. Environmental monitoring on the ORR consists primarily of two major activities: effluent monitoring and environmental surveillance. Effluent monitoring involves the collection and analysis of samples or measurements of liquid and gaseous effluents at the points of release to the environment; these measurements allow the quantification and official reporting of contaminant levels, assessment of radiation and chemical exposures to the public, and demonstration of compliance with applicable standards and permit requirements. Environmental surveillance consists of direct measurements and collection and analysis of samples taken from the site and its environs exclusive of effluents; these activities provide information on contaminant concentrations in air, water, groundwater, soil, foods, biota, and other media. Environmental surveillance data support determinations regarding environmental compliance and, when combined with data from effluent monitoring, support chemical and radiation dose and exposure assessments regarding the potential effects of ORR operations, if any, on the local environment.

Thompson, Sharon D↗