Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

University Research in Support of TREAT Modeling and Simulation, FY 2017

INL is currently evolving a modeling and simulation (M&S) capability that will enable im- proved core operation as well as design and analysis of TREAT experiments. This M&S capability primarily uses MAMMOTH, a reactor physics application being developed under the Multi-physics Object Oriented Simulation Environment (MOOSE) framework. MAMMOTH allows the coupling of a number of other MOOSE-based applications. This work is being supplemented by related research projects at a number of universities. INL is funding TREAT-related research at North Carolina State University, University of New Mexico, Oregon State University, and MIT under internally funded projects within the INL/Battelle National University Consortium Program. Under the DOE Nuclear Energy Advanced Modeling and Simulation program (NEAMS), other research is being performed at MIT, University of Florida, and Texas A&M University. In addition, Dr. Barry Ganapol of University of Arizona was funded for summer work at the INL. This report is a compilation of conference papers that were submitted as part of this research by the NEAMS University partners and from the visiting professor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Xenon International Overview

The Xenon International system is a fully automated unattended system designed to collect, separate, purify, quantify, and perform nuclear counting on radioxenon isotopes as well as transmit data using two-way communications (Figure 1). Xenon International is designed to stringent requirements that make it an high performance next-generation-system for use in nuclear explosion monitoring networks such as the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extending Dynamic Range for Untargeted Ion Mobility-MS Workflows

Preprocessing and identification algorithms can boost the quality and reproducibility of results in untargeted ion mobility (IM)-MS workflows. For this CRADA we developed two methods for pre-processing to improve the quality of Agilent metabolomics data: i) a new saturation repair preprocessing method and ii) multi-dimensional smoothing.

97 MATHEMATICS AND COMPUTING↗

2018 Nanometrics Centaur Digitizer Evaluation

Sandia National Laboratories has tested and evaluated two Nanometrics Centaur digitizers. The Centaur digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Centaur digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Preliminary Modeling to Support the TREAT Hodoscope System for Fuel Motion Monitoring

Fuel motion is monitored in real time at the Transient Reactor Test Facility (TREAT) using a direct-viewing hodoscope that monitors fast neutrons emitted from test fuel undergoing fission during transients. The hodoscope system is now being refurbished, after over twenty years, to once again support research and development activities examining the survival and failure modes of advanced nuclear reactor fuel systems under accident conditions. An im-portant part of this activity is the development of high-fidelity modeling tools to predict the hodoscope's response to different fuel systems, in different test vehicles, throughout different transient cycles. Initial work has involved the collection of archival data related to how the hodoscope currently at TREAT was manufactured and installed, and the use of this data to create a preliminary radiation transport model using MCNP6. This model is now undergoing refinement to improve its fidelity and to permit its integration with other tools under development to model TREAT transients. The model will be used to study how fast-neutrons measured in the hodoscope's detectors relate to the fission of nuclear material in a test vehicle as a function of location within the vehicle and reactor power. The goal is to develop a time-dependent coupling factor that will relate the measured data to the fuel mass present within each pixel of the hodoscope's field of view. This paper will present the current status of the TREAT hodoscope refurbishment program and modeling activities related to interpreting hodoscope data and inferring fuel motion during transients.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of Temporary Shutdown Testing and Groundwater Pump-Testing at Agra, Kansas, February-September 2016 and march 2017, and Assessment of Groundwater and Contaminant Migration

In 2005, the Commodity Credit Corporation/U.S. Department of Agriculture (CCC/USDA) conducted a comprehensive investigation of potential contaminant source areas on, and in the vicinity of, the former CCC/USDA grain storage facility in Agra, Kansas (Argonne 2006). The data collected during this investigation identified three primary source areas for carbon tetrachloride contamination. One source is located on the former CCC/USDA property, and the other two (western and eastern) sources are located on adjacent property owned by Pro-Ag Marketing. The soil source located at the western end of the Pro-Ag property has been identified as the sole source of carbon tetrachloride contamination to the groundwater in this portion of the Agra site, and is not associated with any grain storage activities on the former CCC/USDA property. In 2008-2009, to address the carbon tetrachloride contamination detected on its former property, the CCC/USDA initiated source area cleanup as an interim measure (IM). The cleanup employs five large-diameter boreholes (LDBs) that were excavated by auger drilling. The purposes of these borings were to (1) physically remove soils impacted by carbon tetrachloride from the most contaminated area for treatment by onsite land farming and (2) provide locations for the installation of coupled soil vapor extraction (SVE) and air sparging (AS) wells to facilitate in-situ treatment of the carbon tetrachloride in the soils and underlying groundwater. With the approval of the KDHE, operation of the SVE/AS systems began in May 2009, and has generally continued with minimal interruption since that time. Land farming operations to treat contaminated soil excavated from the LDBs were successfully completed in October 2010.

54 ENVIRONMENTAL SCIENCES↗

Improving the luminosity for Beam Energy Scan II at RHIC

The QCD (Quantum Chromodynamics) phase diagram [1], one of the most im-portant graphs in nuclear physics, has many uncharted territories. In particular,the nature of the transformation from Quark-Gluon plasma (QGP) to the stateof Hadronic gas is totally unknown [2]. A beam energy scan [3,4], scanning thephase diagram with variable collision energy, has been conducted at RHIC toexplore the first-order phase transition and determine the location of a possible critical point.

43 PARTICLE ACCELERATORS↗

Constraints on neutrino oscillation parameters with the NOvA experiment

NOvA is a long-baseline neutrino oscillation experiment, which consists of two finely-segmented liquid-scintillator detectors operating 14 mrad off-axis from the NuMI muon neutrino beam. With an 810 km baseline, the combined measurements of muon neutrino disappearance and electron neutrino appearance allow the determination of neutrino oscillation unknowns, namely the mass hierarchy, the octant of the largest neutrino mixing angle, and the CP violating phase. In this dissertation I present the joint analysis of $\nu_\mu \to \nu_\mu$ and $\nu_\mu \to \nu_e$ oscillation data with an exposure of $8.85\times10^{20}$ protons on target on the 14 kton detector. It includes the estimation of neutrino energy distributions in the far detector using near detector data constraints, details of the implementation of the simultaneous fit of \numu and \nue samples, and the effect of systematic uncertainties on the measurement of oscillation parameters. I also discuss NOvA's projected sensiti vity to determine the mass hierarchy and discover CP violation in future analyses with increased exposure and the addition of antineutrino datasets. With 66 electron neutrino and 126 muon neutrino candidates, the best fit to the data corresponds to the normal mass hierarchy, $\Delta m^2_{32}=2.44\times 10^{-3} eV^2/c^4$, $\sin^2 \theta_{23}=0.56$, and $\delta_{CP} = 1.21\pi$, with the allowed regions $\Delta m^2_{32} \in [2.37,2.52]\times 10^{-3} eV^2/c^4$, $\sin^2 \theta_{23} \in [0.43,0.51] \cup [0.52,0.60]$ and $\delta_{CP} \in [0,0.12\pi] \cup [0.91\pi,2\pi]$ at the 68.3\% C.L. Our data disfavor maximal mixing by 0.8$\sigma$, $\delta_{CP} = \pi/2$ in the inverted hierarchy at higher than 3$\sigma$, and the entire inverted mass hierarchy at the 95\% confidence level. % By increasing the size of the samples and adding anti-neutrino data, \nova can potentially resolve the neutrino mass hierarchy at 4$\sigma$ C.L. or higher for some combinations of oscillation parameters. Im provements to the sensitivity to the determination of the ma! ss hierarchy and CP violation in the neutrino sector can be achieved through gains in the NuMI beam intensity, the inclusion of external data, and refinements in the analysis methodology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Special Analysis: Impact of Updated GSA Flow Model on E-Area Low-Level Waste Facility Groundwater Performance

In March 2018, the Savannah River National Laboratory (SRNL) notified Solid Waste Management (SWM) of new information that could potentially impact groundwater (GW) disposal limits and possibly require temporary protective measures (Crowley 2018). GW flow directions in the E-Area Low-Level Waste Facility (LLWF) Slit Trenches (STs), Engineered Trenches (ETs), and the Low Activity Waste Vault (LAWV) have notably changed in the new 2018 General Separations Area (GSA) flow model (Flach 2018a). The 2018 GSA flow model had been updated using 20 years of new hydrologic field data and model calibration methods that employed mathematical optimization software. It was later determined that the primary reason for the change in GW flow directions was due to the influence of low permeability caps that had been placed over the Old Burial Grounds and the Low Level Radioactive Waste Disposal Facility (LLRWDF). Updated flow directions in the model produce a higher degree of plume overlap for disposal units (DU’s) in the southeastern portion of E-Area than had been predicted in the 2008 E-Area LLWF Performance Assessment (PA). SWM and SRNL outlined the scope for this Special Analysis (SA) and proposed a set of interim measures (IM’s) to protect trench operations from exceeding Performance Objectives (PO’s) during the preparation of this SA, both of which were approved by the SWM Performance Assessment Review Committee (PARC) (Mooneyhan 2018).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Western Sector In-Situ Chemical Oxidation Project: Initial Results Following Injection Activities (U)

The persistence of elevated groundwater concentrations of volatile organic compounds (VOCs) (i.e., trichloroethylene [TCE] and tetrachloroethylene [PCE]) in the Lost Lake Aquifer Zone (LLAZ) requires focused treatment to supplement the removal of these contaminants by the existing corrective action systems. The 2000 Resource Conservation and Recovery Act Part B Permit Renewal Application: M-Area and Metallurgical Laboratory Hazardous Waste Management Facilities (HWMFs) Post Closure (WSRC-IM-98-30, Volume III, Revision 7, March 2014) included the use of four temporary authorization (TA) requests to assess the effectiveness of different corrective action technologies at the field scale in the Western and Southern Sectors of A/M Area. There is indeterminate dense non-aqueous phase liquid (DNAPL) associated with historic migration along geologic strata. The DNAPL source is likely the M-Area Settling Basin; however, the 321-M Solvent Storage Tank Area is another potential source. Both of these source areas have been treated using dynamic underground stripping and soil vapor extraction. Groundwater from both of these potential source locations is currently undergoing groundwater pump and treat.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INSPIRE Phase I Development

Sandia National Laboratories (Sandia) and Makel Engineering, Inc developed a pathway towards an advanced multi-modal sensor system suitable for in-situ analysis of exhaled volatile organic compounds (VOCs) for pilots, divers and field patients. Our proposed In-Mask Sensors for Physiological Investigation of Respiratory Exhalation - INSPIRE, will combine micro-gas chromatograph (microGC) and miniature ion mobility spectrometer (IMS) for detection of trace amounts of exhaled breath VOCs with miniature solid state sensors for inorganic compounds found in breath such as oxygen, carbon dioxide, moisture and the inert gases nitrogen, argon and helium. To develop clear developmental pathway towards that goal Sandia demonstrated a new version of its ion-mobility spectrometer detection technology for VOC detection, while Makel demonstrated detection of inorganics and concepts for mask integration. Sandia demonstrated detection of many compounds from the EPA TO-15 Test Mixture, which is representative of many classes of compounds found in air, and can be purchased as a gas standard from a variety of suppliers. The work demonstrated for phase I was sufficient to move the team into phase II of the program, where a full prototype unit will be developed. This CRADA provided clear value to the taxpayer by allowing a US small business to continue to phase II of a competitive STTR proposal for the Air Force. This process will help to transition Sandia’s technology into the marketplace to address a clear DoD requirement.

Moorman, Matthew↗

Evaluation of Experimental Shroud Designs for the Hyperion 5201W Infrasound Sensor

Sandia National Laboratories has tested and evaluated various infrasound shrouds, produced Doug Seastrand and Gary Walker, DOE staff in Las Vegas, Nevada, intended for a Hyperion 5201W digital infrasound sensor. The purpose of these shrouds is to improve the infrasound sensor’s attenuation of incoherent signals, specifically those caused by wind passing by the sensor. The purpose of the shroud evaluation was to measure amplitude and phase of the sensors with a variety of shroud designs attached and determine whether there is any appreciable changes in amplitude and/or phase response over the IMS passband for infrasound applications, 0.02 Hz to 4.0 Hz. These shrouds utilize a tubule design that directs and mixes airflow from ports radially distributed at approximately 90 degree offsets in an attempt to minimize wind-generated signal due to Bernoulli effect caused by airflow passing by ports perpendicular to the wind.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2019 Hyperion 5313A and 5119A Infrasound Sensor Type Approval Evaluation

Sandia National Laboratories has tested and evaluated two variations of a new model of infrasound sensor, the Hyperion 5313A and 5119A. The purpose of this infrasound sensor evaluation is to measure the performance characteristics in such areas as power consumption, sensitivity, full scale, self-noise, dynamic range, response, passband, sensitivity variation due to changes in static pressure and temperature, and sensitivity to vertical acceleration. The Hyperion infrasound sensors are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty Organization (CTBTO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Multi-Instance learning Framework for Seismic Detectors

In this report, we construct and test a framework for fusing the predictions of a ensemble of seismic wave detectors. The framework is drawn from multi-instance learning and is meant to improve the predictive skill of the ensemble beyond that of the individual detectors. We show how the framework allows the use of multiple features derived from the seismogram to detect seismic wave arrivals, as well as how it allows only the most informative features to be retained in the ensemble. The computational cost of the "ensembling" method is linear in the size of the ensemble, allowing a scalable method for monitoring multiple features/transformations of a seismogram. The framework is tested on teleseismic and regional p-wave arrivals at the IMS (International Monitoring System) station in Warramunga, NT, Australia and the PNSU station in University of Utah's monitoring network.

58 GEOSCIENCES↗

2018 Kinemetrics Q330M+ Digitizer Evaluation

Sandia National Laboratories has tested and evaluated two Kinemetrics Q330M+ digitizers. The digitizers are intended to record sensor output for seismic and infrasound monitoring applications. Notable improvements to the Q330M+ include the support for transmission and authentication of CD1.1 data, integration of analog and digital weather stations, support for multiple gain amplification levels, and the use of a webpage for status and configuration of the digitizer. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test- Ban-Treaty Organization (CTBTO).

47 OTHER INSTRUMENTATION↗

Technical Issues in the Comprehensive Nuclear Test Ban Treaty (CTBT) Ratification Debate: A 20 Year Retrospective

Two decades after the U.S. Senate declined in 1999 to give its consent to ratification of the Comprehensive Nuclear Test Ban Treaty (CTBT), the treaty remains in legal and political limbo. Legally, the treaty cannot enter into force without U.S. ratification. However, the Senate’s rejection does not strip the treaty of its force as an element of customary international law or alter the will of other signatories to see it enter into force. Politically, the debate over the virtues and flaws of the treaty remains as strong as ever, with some CTBT advocates pushing energetically for U.S. re-review while some opponents seek ways to “un-sign” the treaty. Meanwhile, despite the Senate’s rejection of the treaty, the United States acts in a manner consistent with its main obligations by maintaining a moratorium on explosive nuclear testing and providing financial support (as well as technical expertise) to the CTBT Organization (CTBTO)—in particular the CTBTO’s International Monitoring System (IMS). The CTBT may well remain in such limbo for a long time to come, unless some catalytic event comes along to re-shape national perceptions and priorities, one way or the other. The treaty’s future, whatever it might be, will be determined in part by how much perspectives might have changed in light of interim developments. Our purpose is to shed light on some of those developments and to assess their relevance. The 1999 ratification debate addressed a large number of issues. Rejection was driven by various policy and technical judgments. The purpose of this paper is to re-examine those technical judgments in light of what has been learned over the following two decades. On some technical matters, there was explicit recognition of extant uncertainties, as well as a conviction and hope that time would dispel them. To be doubly clear, our purpose is not to recommend a way forward on CTBT ratification. The policy judgments of 1999 and 2020 are beyond the scope of this paper. This technical re-examination proceeds as follows. It begins with a short background section to introduce the key technical matters in discussion in the U.S. ratification process. Then it moves systematically through each of those topics with a review of relevant background information, a discussion of key points in debate, an analysis of subsequent experience, and a current assessment. The historical analysis draws on many sources including the primary documents of the Congressional debate, the official article-by-article interpretation by the Department of State, and the statements of key players in the process. We also relied on key technical reports and publications by subject matter experts that have addressed in more detail many of the issues in our focus. These sources include the 2002 and 2012 reports of the National Academy of Sciences as well as publications by senior technical staff of Lawrence Livermore National Laboratory (LLNL) who were actively involved in the ratification debate, including then-Laboratory Director Bruce Tarter. We also conducted several interviews with government officials from the 1990s, past laboratory directors, and other members of the scientific community. But, except where individuals are specifically cited by name, the judgments offered here are our own and should not be attributed to any other individual or to LLNL as such.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

RASA Field Performance at US International Monitoring Stations

This report attempts to collate, analyze, and summarize RASA performance over time at each of 11 US operated IMS stations. The performance over time was compared to routine maintenance operations. The data, in general, were summarized into a set analyzed almost exclusively in Excel. The data set allows for further probing into RASA performance over time. The data set would permit data to be routinely added for continued analysis. In general, all RASA systems ran within the CTBTO mandated the MDA requirements over their current lifetime of operations. The largest impacts to performance appeared to arise from variabilities of Germanium gamma detectors as they were replaced. It is noted that the air volumes of samples were not provided and had to be assumed to be constant over the period analyzed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation Hardened Foam Cold Test Plan – Phase-I: Foam Adhesion, Contamination Fixation, Moisture Stresses, Pipe Cutting, and Thermal Profile Testing

This document outlines the Phase-I test objectives and implementation plan for a down-selective foam fixative technology intended to facilitate activities in support of the Savannah River Site (SRS) F/H labs deactivation and decommissioning (D&D) efforts. It is a collaborative effort between Savannah River National Laboratory (SRNL), Florida International University (FIU), and the SRS F/H labs team intended to test and evaluate the potential of an intumescent, fire-retardant foam in mitigating the release of contamination during dismantling operations on radioactively contaminated piping in legacy facilities. The cold test plan addresses specific requirements highlighted by site and safety personnel and will be executed in FIU’s Outdoor Test and Evaluation Facility using a mock-up that replicates the operational conditions at the proposed hot test location at F/H labs. Results from the cold test plan will inform the hot test at F/H labs, which will use the foam fixative to confine and/or isolate residual contamination within a 3-dimensional void space of Hastelloy C-22 piping designated for removal from the site and transported to a proper disposal facility. Phase-I testing will address eight test objectives: (1) evaluation of the adhesion and bonding properties of foam fixative in piping, (2) evaluation of the adhesion of the foam fixative in piping under varying moisture conditions, (3) determination of the heat profile of the foam fixative during curing, (4) determination of the relationship between pipe diameter and foam fixative quantity, (5) determination of the internal pipe pressure after foam deployment and curing, (6) development of a leak test standard operating procedure to test for the effectiveness of the foam plug, (7) initiation of a literature review to determine if using a hot tap is a viable method to deliver foam into piping, and (8) initiation of a 10-foot mock up test that will be used in Phase-II cold testing. The cold test will be conducted at FIU and all testing activities will comply with SRNL Conduct of R&D Protocols (SRNL-IM-2020-00019).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗