Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Focusing Ions at Atmospheric Pressure using Nonlinear DC Voltage Sequences Applied to a Stacked Ring Ion Guide

Many modern ion mobility (IM) and mass spectrometers (MS) operate under low pressure (= 10 Torr) and employ high voltage radiofrequencies (RF) to provide ion confinement. Unfortunately, RF effectiveness drastically decreases as pressure increases, and few techniques for focusing ions at elevated pressures exist. Here we demonstrate a new approach for focusing ions at atmospheric pressure (AP) by applying nonlinear DC voltage sequences following quadratic and power (exponential) functions to a stacked ring ion guide. We used ion trajectory simulations to rigorously explore how ions react to nonlinear electric fields and validate the simulations with a set of ion current measurements performed at AP. Ion trajectory simulations show that ions initially defocus near the entrance of the device but then become intensely focused as they travel through the device. Contour plots for both nonlinear voltage sequences show electric field lines that increasingly curve inwards as a function of distance, resulting in spatial ion focusing. Experimental ion current and spot size measurements were performed at AP using a 10-cm stacked ring ion guide and a segmented Faraday cup detector. Quadratic sequences produced ~5% smaller spot sizes (~22.8 mm) and ~25% higher ion current compared to a linear voltage sequence (~24.0 mm). Alternatively, power sequences produced ~64% smaller spot sizes (~8.7 mm), albeit with ~10x lower ion current. However, both nonlinear voltage sequences produced similar ion currents at the center of the Faraday cup detector, indicating that higher ion densities are achieved when using nonlinear voltage gradients. These results demonstrate a new way to focus ions at AP, and the capabilities demonstrated here provide fundamental insights on how to keep ions inside analytical devices at elevated pressures without RF.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fundamental Superconductivity of Nb films for Quantum Computing Application

Niobium is a widely accepted material for quantum computing device as well as superconducting radio frequency (SRF) technology. Superconducting niobium is a marginal type II superconductor which has a very narrow gap (~20-30 mT) of the mixed state at 2K, even showing the intermediate state (IMS) at the early stage of magnetic vortex penetration. Tremendous progress has been made in understanding the impact of the Nb surface and bulk superconductivities on SRF resonator performance. However, the effect of thin superconducting Nb films for quantum computing applications requires further examination. In this study, we explore the fundamental superconducting properties of various thin Nb films and compare them with respect to the energy relaxation time, T1, measured from superconducting qubit fabricated with these films. The Nb films are fabricated both with or without a surface protective layer that prevents the formation of lossy Nb2O5. Electromagnetic properties are characterized by means of bulk magnetization, electromagnetic transport, and dynamics of surface superconductivity. In addition, analytical electron microscopy is implemented to further connect the superconducting properties to microstructure.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Beta-Gamma Data Viewer v2.2.34 User's Manual

This document provides an overview, and procedures, for operating the beta-gamma data viewer for 7 regions of interest (7 ROI) data. The Beta-Gamma 7 ROI Data Viewer is a set of software tools that allow for viewing and analysis of IMS 2.0 Pulse Height Data (PHD) / Pulse Beta Gamma (PBG) files, state of health (SoH) files, and event log files. This is an upgrade from previous release of the tool that includes calibration tools.

97 MATHEMATICS AND COMPUTING↗

Dose Rate Effects on Degradation of Nuclear Power Plant Electrical Cable Insulation at a Common Dose

The intent of this report is to address an identified knowledge gap in relating accelerated aging of nuclear electrical cables to service aging: dose rate effects (DRE). Here, DRE refer to gamma radiation-induced polymer degradation being a function of dose rate in addition to total absorbed dose. The concern raised is that historical qualification conducted at higher dose rates to simulate service lifetime may underestimate insulation degradation that occurs at lower dose rates in service. In the work described herein, common nuclear cable insulation materials—cross-linked polyethylene (XLPE) and ethylene propylene diene elastomer (EPDM)—were subjected to accelerated aging at ambient temperature (26°C) at different gamma dose rates of 100, 200 and 1800 Gy/h for select exposure durations to achieve constant total doses of 170, 210 and 300 kGy to evaluate DRE. First, the cable insulation material types investigated are described. Then, the accelerated aging experimental process involving gamma irradiation applied to the insulation specimens at room temperature and different dose rates is discussed. Then, the experimental characterization techniques used to perform this work are elucidated. These include elongation at break (EAB), mass change, yellowness index (YI), carbonyl index (CI), density, indenter modulus (IM), and relaxation constant (t). Theory of polymer degradation is discussed, and characterization results and discussion are provided. Finally, concluding remarks are made. The findings from this work and cited prior work reveal that DRE are material dependent, even between similar material categories (e.g., XLPE). In the case of the EPDM studied, degradation of ductility was observed to be greater at higher dose rate for the same total dose, indicating accelerated gamma aging to be more conservative than extended aging. Thus, conclusions regarding the conservatism of historical qualification likely require additional consideration for specific materials and conditions in question. The results of this study support the contention that, due to inherent limitations and uncertainties associated with prediction of cable remaining useful life from accelerated aging experiments, trending of installed cable insulation health status will be more practical and useful for safe and efficient cable aging management repair and replace decisions than lifetime prediction from historical qualification. The combination of material robustness demonstrated by the qualification process and ongoing monitoring of cable health status combine to provide confidence in continued safe use of existing nuclear cables. Additional research into effective and efficient condition monitoring methods for non-destructive evaluation of installed cables is needed to support aging cable management, including material studies to inform interpretation of measured results.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Exploration of Fuel Property Impacts on the Combustion of Late Post Injections Using Binary Blends and High-Reactivity Ether Bioblendstocks

In this study, the impacts of fuel volatility and reactivity on com- bustion stability and emissions were studied in a light-duty single- cylinder research engine for a three-injection catalyst heating oper- ation strategy with late post-injections. N-heptane and blends of farnesane/2,2,4,4,6,8,8-heptamethylnonane were used to study the im- pacts of volatility and reactivity. The effect of increased chemical reac- tivity was also analysed by comparing the baseline #2 diesel operation with a pure blend of mono-ether components (CN > 100) representa- tive of potential high cetane oxygenated bioblendstocks and a 25 vol.% blend of the mono-ether blend and #2 diesel with a cetane number (CN) of 55. At constant reactivity, little to no variation in combustion performance was observed due to differences in volatility, whereas in- creased reactivity improved combustion stability and efficiency at late injection timings. Fuels with higher reactivity were found to reduce engine-out hydrocarbon and carbon monoxide emissions while also achieving stable combustion at post-injection timings later than those achievable with #2 diesel fuel. The pure ether blend had the latest achievable post-injection timing of +30.5 CAD while still maintaining stable combustion (coefficient of variation of gross-indicated mean ef- fective pressure < 5%). With post-injection timing adjusted to achieve a matched exhaust temperature of 300 °C, the ether-diesel CN 55 blend was observed to have slightly higher thermal efficiency in comparison to the baseline #2 diesel fuel. The results also indicate that cetane num- ber may serve as a good indicator of combustion characteristics at late injection timings used for aftertreatment thermal management opera- tion.

99 GENERAL AND MISCELLANEOUS↗

2023 Reftek Wrangler Digitizer Type Approval Evaluation

Sandia National Laboratories has tested and evaluated the Reftek Wrangler digitizer. The Wrangler digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self-noise, dynamic range, system noise, response, passband, and timing. The Wrangler digitizers are being evaluated for potential use in the International Monitoring System (IMS) and On-site Inspection (OSI) components of Comprehensive Nuclear-Test-Ban Treaty (CTBT).

58 GEOSCIENCES↗

2023 Reftek Colt Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated three Colt broadband seismometers designed and manufactured by Reftek. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The Colt model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

Algorithms and file structures to extend and enhance liquid chromatography and ion mobility mass spectrometry workflows (CRADA Final Report)

The purpose of this project was to continue supporting customizations of algorithms and raw data file structures to enhance software workflows for liquid chromatography (LC), mass spectrometry (MS) and ion mobility mass spectrometry (IM-MS)-based protein and metabolite characterization. PNNL worked with Agilent to design, implement, evaluate, and demonstrate new algorithms and integrated them as functionalities into the PNNL-PreProcessor software. The project augmented PNNL’s capabilities to analyze complex proteomics and metabolomics samples. These capabilities are directly beneficial to DOE and PNNL efforts to characterize and analyze these compounds in microbial and plant communities. The project assisted Agilent in further developing improved instrument-software solutions combining liquid chromatography and ion mobility with mass spectrometry for widespread applications in life sciences and other fields.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2023 T120 Horizon and Slim Posthole Seismometer Exploratory Evaluation

Sandia National Laboratories has tested and evaluated a suite of four T120 broadband seismometers designed and manufactured by Nanometrics. Specifically, two T120 Horizon V2 sensors, one T120 Horizon V1 sensor and one T120 Slim Posthole (PH) sensor were evaluated. The purpose of this seismometer evaluation is to measure performance characteristics in areas such as power consumption, sensitivity, frequency response, full scale, self-noise, dynamic range, calibration system response, and passband. The T120 model of sensors are being evaluated to explore the potential for a future seismometer Type Approval process in the International Monitoring System (IMS) of the Comprehensive Nuclear-Test-Ban Treaty (CTBT).

47 OTHER INSTRUMENTATION↗

MaPSA Quality Control and AI-Enhanced Grading For the CMS Phase-II Tracker Upgrade

The Compact Muon Solenoid (CMS) experiment will undergo changes as part of the Large Hadron Collider upgrade. The CMS tracker will be upgraded to cope with the new radiation environment and to provide tracking at the first level trigger. This upgrade features a new type of silicon module called PS Module, which combines a Pixel sensor and a Strip sensor in the same module. The pixel portion of the PS module has a sensor bump bonded to 16 Macro Pixel ASICs (MPA) to form a Macro Pixel Sub Assembly (MaPSA). At Fermilab, MaPSAs are tested for quality control before being assembled with the strip sensors, readout and service electronics to form a PS Module. All of this test data is stored in a centralized database, and is used to grade the final module to determine if it will be installed in the detector. The Phase II Outer Tracker Analyzer of Test Outputs (POTATO) is the software that processes this data and determines the module grades. Using recent technologies, an AI agent is being im plemented into POTATO in order to allow users to more efficiently sort through the large amounts of analysis data and ensure that only the user specified data is being considered. This poster will display the process of testing a MaPSA, how that test data is relevant to module assembly and grading, and how the POTATO grading tool is being improved with the use of an embedded AI agent.

Gzamouranis, Olivia [Purdue U.]↗

Vision 0.3.2 Users Guide: Revision 0

Vision is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. These stations are part of a worldwide network to monitor for nuclear explosions, and the data they produce are critical to make the determination of whether a sample is from a nuclear explosion or some other source (i.e., nuclear reactor or medical isotope production facility). Stations deliver their measurements and system status to the International Monitoring System (IMS), which forwards it via email to all subscribers. Vision provides tools for viewing and analyzing these stations’ state of health data.

97 MATHEMATICS AND COMPUTING↗

Beowulf v2.5.3 User Guide: Revision 5

This document is a user guide for the Beowulf (rebranding of Watchmen) tool. It describes how operators can access and utilize the application's functionality. Beowulf is a research software application developed by Pacific Northwest National Laboratory (PNNL) that incorporates the scientific and operational expertise for reviewing data from treaty monitoring radionuclide stations. These stations are part of a worldwide network to monitor for nuclear explosions, and the data they produce are critical to make the determination of whether a sample is from a nuclear explosion or some other source (i.e., nuclear reactor or medical isotope production facility). Stations deliver their measurements and system status to the International Monitoring System (IMS), which forwards it via email to all subscribers. Beowulf is capable of processing data from several radioxenon station types and development is in progress on a solution for particulate stations. Screening of data in Beowulf may be done by a number of different users such as radionuclide analysts, evaluators, and data quality experts. This guide is provided to assist those users in navigating the application. The term Beowulf is used generically throughout this document to refer to any of the various components in the software application. The user interface that is viewed with a web browser is the primary focus of this user guide. Other components include a database to store measurements and state of health (SOH) data; and the data loader that monitors incoming emails, parses the data, populates the database, does the initial analysis, and routes data for review.

97 MATHEMATICS AND COMPUTING↗

Developing a Vaccine Platform for a Balanced Mucosal Immune Response (CB11446), Project Report: Year 1

Mucosal vaccines can elicit protective immune responses at the infection site of respiratory or aerosolized pathogens. Achieving balanced mucosal and systemic responses is a key challenge in the design of mucosal vaccines, especially in terms of developing a broadly applicable vaccine delivery platform amenable to a wide range of subunit vaccine antigens. The overarching goal of the project entitled “Developing a Vaccine Platform for a Balanced Mucosal Immune Response” is to develop a pathogen-agnostic vaccine platform that elicits robust and balanced mucosal immune responses upon intranasal vaccination, in the context of a nanolipoprotein particle (NLP) platform. In year one, we investigated NLP-based vaccine formulations incorporating select immune adjuvants (Monophosphoryl Lipid A (MPLA), FSL-1, L18-muramyl dipeptide (MDP), and cholesterol-tagged ODN2006 (cCpG)) along with antigens relevant to plague (LcrV), tularemia (IglC), and Ebola virus (GP). We demonstrated the ability to prepare, characterize, and quantify these formulations. We then carried out studies in vivo using a BALB/c mouse model, comparing intranasal and intramuscular administration and systematically evaluated the resulting mucosal and systemic immune responses using ELISpot and ELISAs. All proposed tasks (Table 1) were completed within the twelve-month base period, and the established go/no go metric was successfully achieved. Numerous adjuvant:LcrV:NLP formulations were found to have statistically significant increases in IgA titers in serum and/or lung upon IN administration (compared to IM administration), while also producing robust IgG responses in serum. Some formulations also showed significant IFNγ responses using restimulated splenocytes. The data collected during the base period provide valuable insights for the future design of safe and effective mucosal subunit vaccines while also highlighting areas of research that merit further investigation.

59 BASIC BIOLOGICAL SCIENCES↗

Energy Deposition Analysis of VERA Progression Problems using MCNP6

The current energy deposition model in the CASL neutronics code MPACT assumes all the fission energy is deposited locally. This approximation limits the accurate represen tation of the heating source distribution in the reactor core, which is essential for the thermal/hydraulic coupling calculations. There has been ongoing work to develop im proved models in MPACT to account for the energy deposition distribution of gamma rays, including direct fission gamma (prompt and delayed) and the gamma rays from neutron capture. Also, the neutron/photon coupling transport calculation has been considered as a potential capability to be added in MPACT to provide high-fidelity heating calculations. In order to provide a reference solution for these gamma heating models, MCNP has been used in this work to develop a set of energy deposition bench mark problems, based on the elective VERA Progression Problems, including single pin cells, 2-D assemblies and 2-D quarter core cases.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Thermal Compton Scattering of Electron Beams on Blackbody Photons: A Monte Carlo Event Generator for Multi-Turn Tracking at the Electron-Ion Collider

Compton scattering of ultra-relativistic electrons on thermal (blackbody) photons is typically a subdominant process in electron storage rings, but at sufficiently high electron energy and low residual gas pressure it can become competitive with beam-gas scattering and contribute to dis tributed losses and backgrounds. We present a self-contained Monte Carlo event generator for thermal Compton scattering designed for integration into multi-turn tracking workflows. The im plementation follows H. Burkhardt’s proposal method: trial scattering angles are sampled from the Thomson differential cross section and accepted/rejected using the Klein-Nishina to Thomson ratio, yielding the correct Compton spectrum while retaining simple absolute-rate normalization. Ther mal photon energies are sampled from the blackbody photon-number spectrum via an exact mixture representation.

43 PARTICLE ACCELERATORS↗