Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Homogenization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Innovative methodology for the synthesis of Ba-M hexaferrite BaFe{sub 12}O{sub 19} nanoparticles

Graphical abstract: Transmission electron microscope images for the BaFe12O19. - Highlights: • BaFe{sub 12}O{sub 19}nanoparticles were prepared in single-phase from organometallic precursors. • BaFe{sub 12}O{sub 19} possesses small size 65 nm, H{sub C} = 3695 Oe and M{sub s} = 58 emu/g. • This method of preparation could be extended in the synthesis of other metal oxide nanoparticles. - Abstract: In this piece of work, high quality and homogeneity, barium hexaferrite (BaM) BaFe{sub 12}O{sub 19} nanoparticles were prepared from organometallic precursors for the 1st time. This method is based on the formation of supramolecular crystal structure of Ba[Fe(H{sub 3}NCH{sub 2}CH{sub 2}NH{sub 3})]Cl{sub 7}·8H{sub 2}O. The crystal structure, morphology and magnetic properties of BaFe{sub 12}O{sub 19} at two different annealing temperatures namely 1000 °C and 1200 °C were investigated using X-ray diffraction, transmission electron microscope TEM and vibrating sample magnetometry (VSM). The results show that monophasic nanoparticles of hexaferrites were obtained. Nanoparticles of crystallite size 40–50 nm distinguished by narrow distribution and excellent homogeneity were obtained with superior magnetic properties which suggested single-domain particles of Ba-M hexaferrite.

36 MATERIALS SCIENCE↗

Improving the low-temperature capacitance of CoNiAl three-component layered double hydroxide in a redox electrolyte

Graphical abstract: The specific capacitance of CoNiAl layered double hydroxide in 6 M KOH reduces sharply from room temperature to −20 °C, which is effectively enhanced by adding redox pair Fe(CN){sub 6}{sup 3−}/Fe(CN){sub 6}{sup 4−} in the electrolyte. - Highlights: • CoNiAl layered double hydroxide is synthesized by homogeneous precipitation. • The specific capacitance reduces sharply with the decrease of temperature. • At −20 °C the specific capacitance is increased by 178% in a redox electrolyte. - Abstract: CoNiAl three-component layered double hydroxide with a lamellar structure similar to hydrotalcite-like compounds is synthesized via homogeneous precipitation and the effect of temperature on its capacitive performances in 6 M KOH is investigated. Electrochemical tests show its specific capacitance reduces sharply with the decrease of temperature from 18 to −20 °C. At −20 °C an increase of specific capacitance by 178% is achieved by adding redox pair Fe(CN){sub 6}{sup 3−}/Fe(CN){sub 6}{sup 4−} as the electron shuttle in the electrolyte due to their cooperation with the electrode reaction during the charge/discharge processes.

36 MATERIALS SCIENCE↗

A chemical approach toward low temperature alloying of immiscible iron and molybdenum metals

Graphical abstract: - Highlights: • Low temperature pyrolysis of [Fe(bipy){sub 3}]Cl{sub 2} and [Mo(bipy)Cl{sub 4}] homogeneous powder. • Easy low temperature alloying of immiscible metals like Fe and Mo. • Uniform sized Fe–Mo nanoalloy with particle size of 48–68 nm. • Characterization by EDXRF, AFM, XRPD, magnetometery, {sup 57}Fe Mössbauer and impedance. • Alloy behaves as almost superparamagnetic obeying simple –R(CPE)– circuit. - Abstract: The present research is based on a low temperature operated feasible method for the synthesis of immiscible iron and molybdenum metals’ nanoalloy for technological applications. The nanoalloy has been synthesized by pyrolysis of homogeneous powder precipitated, from a common solvent, of the two complexes, trisbipyridineiron(II)chloride, [Fe(bipy){sub 3}]Cl{sub 2}, and bipyridinemolybedenum(IV) chloride, [Mo(bipy)Cl{sub 4}], followed by heating at 500 °C in an inert atmosphere of flowing argon gas. The resulting nanoalloy has been characterized by using EDXRF, AFM, XRD, magnetometery, {sup 57}Fe Mössbauer and impedance spectroscopies. These results showed that under provided experimental conditions iron and molybdenum metals, with known miscibility barrier, alloy together to give (1:1) single phase material having particle size in the range of 48–66 nm. The magnetism of iron is considerably reduced after alloy formation and shows its trend toward superparamagnetism. The designed chemical synthetic procedure is equally feasible for the fabrication of other immiscible metals.

36 MATERIALS SCIENCE↗

Growth and characterization of kesterite Cu{sub 2}ZnSn(S{sub x}Se{sub 1−x}){sub 4} crystals for photovoltaic applications

Highlights: • Cu{sub 2}ZnSn(S{sub x}Se{sub 1−x}){sub 4} crystals were grown using vertical gradient freeze technique. • Grown CZTSSe crystals exhibited highly crystalline tetragonal kesterite structure. • Grown ingot showed a homogeneous, stoichiometric composition along the growth axis. • Cu-rich particulates were observed along the polycrystalline grain boundaries. • Large volume of high quality CZTSSe can be grown using this novel VGF method. - Abstract: Cu{sub 2}ZnSn(S{sub x}Se{sub 1−x}){sub 4} (CZTSSe) bulk crystals have been grown for the first time, in multi-gram quantities, using a novel vertical gradient freeze (VGF) technique. Large grain polycrystalline CZTSSe ingot with grain sizes ∼0.2–0.5 mm was grown in a vacuum sealed quartz ampoule. Structural, compositional, and electronic properties of the ingot were characterized by X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), energy dispersive X-ray spectroscopy (EDS), and van der Pauw measurements. XRD analysis showed highly crystalline tetragonal structure corresponding to kesterite CZTSSe with lattice constants of a = 5.563 Å, and c = 11.09 Å (c/2a = 0.997) and Raman spectra confirmed the formation of single phase CZTSSe. High-resolution XPS spectra confirmed the formation of metal-sulfoselenides. The ingot along the growth axis showed a homogeneous near stoichiometric elemental distribution corresponding to Cu/(Zn + Sn) = 0.94 and Zn/Sn = 0.98. EDS mapping on the ingot's outer surface revealed formation of islanded Cu-rich droplets at the grain boundaries. Grown crystals exhibited p-type conductivity with a measured bulk resistivity of ∼51 Ω cm.

36 MATERIALS SCIENCE↗

Microwave-assisted synthesis and optical properties of cuprous oxide micro/nanocrystals

Graphical abstract: Cuprous oxide micro/nanocrystals were fabricated by a facile and green microwave-assisted method using soluble starch as reductant and dispersant. Spheres with the diameter of about 100 and 600 nm, octahedron and truncated octahedron with the edge length of about 0.8–3 μm cuprous oxide micro/nanocrystals were successfully obtained. Microwave heating was proved to be a efficient method and was advantageous to the homogeneous nucleation. Growth mechanism of the prepared Cu{sub 2}O microcrystals were investigated carefully. Furthermore, the optical properties of the prepared cuprous oxide microcrystals were investigated by UV–vis diffuse reflectance spectroscopy, demonstrating that their band gaps of obtained samples were 1.96–2.07 eV, assigned to their different sizes and morphologies. - Abstract: Cuprous oxide micro/nanocrystals were fabricated by a facile and green microwave-assisted method using soluble starch as reductant and dispersant. It was observed that the addition amounts of NaOH had a prominent effect on the morphologies and size of cuprous oxide products, and microwave heating was proved to be a efficient method and was advantageous to the homogeneous nucleation. The as-obtained samples were characterized by X-ray diffraction (XRD), and field-emission scanning electron microscopy (FESEM). The results indicated that the samples were pure cuprous oxide. Spheres with the diameter of about 100 and 600 nm, octahedron and truncated octahedron with the edge length of about 0.8–3 μm cuprous oxide micro/nanocrystals were successfully obtained. Furthermore, the UV–vis diffuse reflectance spectroscopy was used to investigate the optical properties of the prepared cuprous oxide microcrystals, demonstrating that their band gaps of obtained samples were 1.96–2.07 eV, assigned to their different sizes and morphologies.

36 MATERIALS SCIENCE↗

Synthesis and thermoluminescence studies of γ-irradiated Dy{sup 3+} doped SrGd{sub 2}O{sub 4} phosphor

Highlights: • SrGd2O4:Dy3+ phosphors have been prepared via homogeneous precipitation cum auto-combustion method for the first time. • TL characteristics of γ-irradiated SrGd2O4: Dy3+ phosphors were studied for various Dy3+ contents and heating rates. • Linear TL profile, less fading and high reproducibility of the present phosphor system reveals its applicability in TL dosimetry. - Abstract: Dy{sup 3+} doped SrGd{sub 2}O{sub 4} phosphors were synthesized via homogeneous precipitation cum auto-combustion method for the first time. Orthorhombic phase formation and granular morphology of SrGd{sub 2}O{sub 4}: Dy{sup 3+} samples were investigated through X-ray diffraction (XRD) and microscopic studies. Thermoluminescence (TL) characteristics of SrGd{sub 2}O{sub 4}: Dy{sup 3+} phosphors were taken after exposure of {sup 60}Co γ-rays. The TL glow curve of as-prepared phosphors was well-resolved into five peaks 114 °C, 161 °C, 198 °C, 248 °C, and 293 °C by using computerized glow curve deconvolution program. The effect of impurity (Dy{sup 3+}) contents and heating rates for the TL glow curves were also studied. The linear behaviour of as-formed SrGd{sub 2}O{sub 4}: Dy{sup 3+} samples are observed within a wide range of dose of 80 Gy–2 kGy. Fading characteristics of SrGd{sub 2}O{sub 4}: Dy{sup 3+} phosphor was studied over the duration of 30 days. A comparative study was done to estimate different trapping parameters by employing Chen’s peak shape method and CGCD simulation of TL glow curves.

36 MATERIALS SCIENCE↗

Fluorescein-sensitized Au/g-C3N4 nanocomposite for enhanced photocatalytic hydrogen evolution under visible light

Highlights: • Preparation of Au/g-C{sub 3}N{sub 4} composite through protonation, adsorption and reduction. • Au nanoparticles with average diameter of 4.1 nm are homogeneous deposited on g-C{sub 3}N{sub 4}. • The H{sub 2} evolution rate of Au/g-C{sub 3}N{sub 4} raises by 22 times after fluorescein sensitization. • Efficient transfer of photo-generated electrons among fluorescein, g-C{sub 3}N{sub 4} and Au. - Abstract: Au/g-C{sub 3}N{sub 4} composite is prepared through protonation of g-C{sub 3}N{sub 4}, followed by electrostatic adsorption of AuCl{sub 4{sup {sub −}}} and subsequent chemical reduction. The homogeneous deposition of Au nanoparticles with an average diameter of 4.1 nm on g-C{sub 3}N{sub 4} is confirmed by TEM measurement. Compared with pure g-C{sub 3}N{sub 4}, Au/g-C{sub 3}N{sub 4} composite exhibits a significant improvement in the photocatalytic activity for H{sub 2} production from water in the presence of triethanolamine as sacrificial electron donor under visible light irradiation (λ > 420 nm). Significantly, the rate of H{sub 2} production increases more than 22 times by adding fluorescein in the photocatalytic reaction system. It is more than 25 times higher than that of protonated g-C{sub 3}N{sub 4} in the presence of fluorescein. Based on our experimental results, the mechanism of photocatalytic activity for H{sub 2} evolution over fluorescein-sensitized Au/g-C{sub 3}N{sub 4} nanocomposite is accordingly proposed. The highly-improved performance is ascribed to the efficient transfer of photo-generated electrons among photo-excited fluorescein molecule, g-C{sub 3}N{sub 4} and Au, which is supported by photoluminescence spectra and transient photocurrent responses.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Structural, morphological, optical and magnetic properties of Ag3(2+x)InxNb4-xO11+δ (0.25 ≤ x ≤ 1.0) nanoparticles synthesized by sol–gel method

Highlights: • Novel Ag{sub 3 (2+x)} In{sub x}Nb{sub 4-x}O{sub 11+δ} nanoparticles were synthesized by sol-gel method and studied their optical magnetic properties. • XRD studies confirm the single-phase monoclinic lattice structure with P2/m space group. • Morphology, purity and homogeneity of samples were confirmed by SEM images, EDX and X-ray mapping. • The absorption spectra and tauc plots confirms the semiconductor nature of the samples. • Magnetic studies reveals the ferromagnetic behavior of the samples at room temperature. - Abstract: Herein, we report the structure, morphology, optical and magnetic properties of novel Ag{sub 3 (2+x)} In{sub x}Nb{sub 4-x}O{sub 11+δ} (0.25 ≤ × ≤ 1.0; A1–A4) nanoparticles prepared by sol-gel technique. The samples were studied using X-ray diffraction, electron microscopy, diffuse reflectance spectroscopy, vibrating sample magnetometer, and electron spin resonance. X-ray diffraction studies confirm the formation of monoclinic lattice type with P2/m space group. Purity and homogeneity of the samples were confirmed by X-ray mapping. The semiconductor nature of the samples was identified by optical absorption spectra which indicate an inter-band transition from the oxygen 2p to niobium 4d electronic states. The magnetization plots reveal the room temperature ferromagnetic behavior of the samples.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Reducing the Risk of Xerostomia and Mandibular Osteoradionecrosis: The Potential Benefits of Intensity Modulated Radiotherapy in Advanced Oral Cavity Carcinoma

Radiation therapy for squamous cell carcinoma of the oral cavity may be curative, but carries a risk of permanent damage to bone, salivary glands, and other soft tissues. We studied the potential of intensity modulated radiotherapy (IMRT) to improve target volume coverage, and normal tissue sparing for advanced oral cavity carcinoma (OCC). Six patients with advanced OCC requiring bilateral irradiation to the oral cavity and neck were studied. Standard 3D conformal radiotherapy (3DCRT) and inverse-planned IMRT dose distributions were compared by using dose-volume histograms. Doses to organs at risk, including spinal cord, parotid glands, and mandible, were assessed as surrogates of radiation toxicity. PTV1 mean dose was 60.8 {+-} 0.8 Gy for 3DCRT and 59.8 {+-} 0.1 Gy for IMRT (p = 0.04). PTV1 dose range was 24.7 {+-} 6 Gy for 3DCRT and 15.3 {+-} 4 Gy for IMRT (p = 0.001). PTV2 mean dose was 54.5 {+-} 0.8 Gy for 3DCRT and for IMRT was 54.2 {+-} 0.2 Gy (p = 0.34). PTV2 dose range was improved by IMRT (7.8 {+-} 3.2 Gy vs. 30.7 {+-} 12.8 Gy, p = 0.006). Homogeneity index (HI) values for PTV2 were closer to unity using IMRT (p = 0.0003). Mean parotid doses were 25.6 {+-} 2.7 Gy for IMRT and 42.0 {+-} 8.8 Gy with 3DCRT (p = 0.002). The parotid V30 in all IMRT plans was <45%. The mandible V50, V55, and V60 were significantly lower for the IMRT plans. Maximum spinal cord and brain stem doses were similar for the 2 techniques. IMRT provided superior target volume dose homogeneity and sparing of organs at risk. The magnitude of reductions in dose to the salivary glands and mandible are likely to translate into reduced incidence of xerostomia and osteoradionecrosis for patients with OCC.

61 RADIATION PROTECTION AND DOSIMETRY↗

Helical Tomotherapy of Nasopharyngeal Carcinoma-Any Advantages Over Conventional Intensity-Modulated Radiotherapy?

Helical tomotherapy uses different planning algorithm and dose delivery method from the linear accelerator (linac)-based intensity-modulated radiotherapy (IMRT). This study compared the dosimetric outcomes between the tomotherapy plans and conventional linac-based IMRT plans in the treatment of nasopharyngeal carcinoma (NPC). Fifteen stage II-III cancer (American Joint Committee on Cancer) NPC patients treated by tomotherapy were conveniently recruited. Apart from the tomotherapy plans, a 7-field 6-MV photon conventional IMRT plan was computed for each patient with the same CT dataset and reference from the dose constraints and target dose prescriptions of the tomotherapy plans using the XiO treatment planning system. Average values of the dose parameters including the conformity index (CI), homogeneity index (HI), maximum and minimum doses of the target volumes, and the maximum and mean doses of the organs at risk (OAR) were compared between the two treatment methods. Better dose coverage of the planning target volume (PTV) was demonstrated in the tomotherapy plans, in which the differences in the maximum and mean doses reached statistical significance (p < 0.05). Besides, the CI of the tomotherapy plans were significantly higher than the conventional linac-based plans for the nasopharynx PTV (NP-PTV) and neck lymphatics PTV (LN-PTV) (p = 0.017 and 0.010, respectively). The HI was significantly smaller in both NP-PTV and LN-PTV (p = 0.024 and < 0.001, respectively). Among the OAR, the brain stem and spinal cord doses in the tomotherapy plans were lower than that of the conventional IMRT plans. However, the doses to the other OAR did not show significant dosimetric differences. In the treatment of nasopharyngeal carcinoma, tomotherapy plans were superior to the 7-field conventional IMRT plans in PTV dose conformity and homogeneity and the sparing of the brain stem and spinal cord. However, no significant advantages were observed for the rest of the OAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric Comparison of Helical Tomotherapy and Linac-IMRT Treatment Plans for Head and Neck Cancer Patients

The rapid development and clinical implementation of external beam radiation treatment technologies continues. The existence of various commercially available technologies for intensity-modulated radiation therapy (IMRT) has stimulated interest in exploring the differential potential advantage one may have compared with another. Two such technologies, Hi-Art Helical Tomotherapy (HT) and conventional medical linear accelerator-based IMRT (LIMRT) have been shown to be particularly suitable for the treatment of head and neck cancers. In this study, 23 patients who were diagnosed with stages 3 or 4 head and neck cancers, without evidence of distance metastatic disease, were treated in our clinic. Treatment plans were developed for all patients simultaneously on the HT planning station and on the Pinnacle treatment planning system for step-and-shoot IMRT. Patients were treated only on the HT unit, with the LIMRT plan serving as a backup in case the HT system might not be available. All plans were approved for clinical use by a physician. The prescription was that patients receive at least 95% of the planning target volume (PTV), which is 66 Gy at 2.2 Gy per fraction. Several dosimetric parameters were computed: PTV dose coverage; PTV volume conformity index; the normalized total dose (NTD), where doses were converted to 2 Gy per fraction to organs at risk (OAR); and PTV dose homogeneity. Both planning systems satisfied our clinic's PTV prescription requirements. The results suggest that HT plans had, in general, slightly better dosimetric characteristics, especially regarding PTV dose homogeneity and normal tissue sparing. However, for both techniques, doses to OAR were well below the currently accepted normal tissue tolerances. Consequently, factors other than the dosimetric parameters studied here may have to be considered when making a choice between IMRT techniques.

61 RADIATION PROTECTION AND DOSIMETRY↗

Conformal Locoregional Breast Irradiation with an Oblique Parasternal Photon Field Technique

We evaluated an isocentric technique for conformal irradiation of the breast, internal mammary, and medial supra-clavicular lymph nodes (IM-MS LN) using the oblique parasternal photon (OPP) technique. For 20 breast cancer patients, the OPP technique was compared with a conventional mixed-beam technique (2D) and a conformal partly wide tangential (PWT) technique, using dose-volume histogram analysis and normal tissue complication probabilities (NTCPs). The 3D techniques resulted in a better target coverage and homogeneity than did the 2D technique. The homogeneity index for the IM-MS PTV increased from 0.57 for 2D to 0.90 for PWT and 0.91 for OPP (both p < 0.001). The OPP technique was able to reduce the volume of heart receiving more than 30 Gy (V{sub 30}), the cardiac NTCP, and the volume of contralateral breast receiving 5 Gy (V{sub 5}) compared with the PWT plans (all p < 0.05). There is no significant difference in mean lung dose or lung NTCP between both 3D techniques. Compared with the PWT technique, the volume of lung receiving more than 20 Gy (V{sub 20}) was increased with the OPP technique, whereas the volume of lung receiving more than 40 Gy (V{sub 40}) was decreased (both p < 0.05). Compared with the PWT technique, the OPP technique can reduce doses to the contralateral breast and heart at the expense of an increased lung V{sub 20}.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Technique for Stereotactic Radiosurgery Treatment Planning with Helical Tomotherapy

The purpose of this study was to develop an efficient and effective planning technique for stereotactic radiosurgery using helical tomotherapy. Planning CTs and contours of 20 patients, previously treated in our clinic for brain metastases with linac-based radiosurgery using circular collimators, were used to develop a robust TomoTherapy planning technique. Plan calculation times as well as delivery times were recorded for all patients to allow for an efficiency evaluation. In addition, conformation and homogeneity indices were calculated as metrics to compare plan quality with that which is achieved with conventional radiosurgery delivery systems. A robust and efficient planning technique was identified to produce plans of radiosurgical quality using the TomoTherapy treatment planning system. Dose calculation did not exceed a few hours and resulting delivery times were less than 1 hour, which allows the process to fit into a single day radiosurgery workflow. Plan conformity compared favorably with published results for gamma knife radiosurgery. In addition, plan homogeneity was similar to linac-based approaches. The TomoTherapy planning software can be used to create plans of acceptable quality for stereotactic radiosurgery in a time that is appropriate for a radiosurgery workflow that requires that planning and delivery occur within 1 treatment day.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Case Report on the Effect of Fan Beam Thickness in Helical Tomotherapy of Nasopharyngeal Carcinoma

The fan beam thickness (FBT) in helical tomotherapy is defined by a pair of collimators parallel to the rotational orbit of the radiation beam and is fixed for a specific patient treatment. The aim of this case study is to evaluate the dosimetric influence of changing the FBT in the treatment of a nasopharyngeal carcinoma (NPC) patient. The subject was a T2N1M0 stage NPC patient. The planning target volumes (PTVs) of the primary nasopharyngeal tumor and the left and right cervical lymphatics were delineated along with the organs at risk (OARs) in the corresponding computed tomography slices. Three treatment plans with FBT of 1.0 cm, 2.5 cm, and 5.0 cm (FBT-10, FBT-25, and FBT-50) were generated separately based on similar dose constraints and planning parameters. The dosimetric results of the PTV and OARs were collected and compared among the 3 treatment plans. The differences in the dose parameters of the PTVs were small among the 3 plans. The FBT-10 plan demonstrated the most homogeneous PTV doses with the smallest homogeneity indices (HIs). The FBT-50 plan delivered the highest dose to the OARs and the FBT-10 plan delivered the lowest. The differences between the 2 plans were more significant in the spinal cord, optic chiasm, optic nerves, and lens. This case study demonstrated that the variation of FBT in tomotherapy affected the quality of the treatment plan mainly in the OAR doses, but not so much in the PTV. Increasing the FBT reduced the effectiveness in the sparing of OARs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy Delivery of an IMRT Boost in Lieu of Interstitial Brachytherapy in the Setting of Gynecologic Malignancy: Feasibility and Dosimetric Comparison

Interstitial brachytherapy is an important means by which to improve local control in gynecologic malignancy when intracavitary brachytherapy is untenable. Patients unable to receive brachytherapy have traditionally received conventional external beam radiation alone with modest results. We investigated the ability of Tomotherapy (Tomotherapy Inc., Madison, WI) to replace interstitial brachytherapy. Six patients were selected. The planning CT of each patient was contoured with the planning target volume (PTV), bladder, rectum, femoral heads, and bowel. Identical contour sets were exported to Tomotherapy and Nucletron PLATO (Nucletron B.V., Veenendaal, The Netherlands). With Tomotherapy, the PTV was prescribed 31 Gy in 5 fractions to 90% of the volume. With PLATO, 600 cGy x 5 fractions was prescribed to the surface of the PTV. Dose delivered was normalized to 2 Gy fractions (EQD2) and added to a hypothetical homogenous 45-Gy pelvic dose. Tomotherapy achieved a D90 of 87 Gy EQD2 versus 86 Gy with brachytherapy. PTV dose was more homogeneous with tomotherapy. The dose to the most at-risk 2 mL of bladder and rectum with Tomotherapy was of 78 and 71 Gy EQD2 versus 81 and 75 Gy with brachytherapy. Tomotherapy delivered more dose to the femoral heads (mean 1.23 Gy per fraction) and bowel. Tomotherapy was capable of replicating the peripheral dose achieved with brachytherapy, without the PTV hotspots inherent to interstitial brachytherapy. Similar maximum doses to bowel and bladder were achieved with both methods. Excessive small bowel and femoral head toxicity may result if previous pelvic irradiation is not planned accordingly. Significant challenges related to interfraction and intrafraction motion must be overcome if treatment of this nature is to be contemplated.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comparison of Helical Intensity-Modulated Radiotherapy, Intensity-Modulated Radiotherapy, and 3D-Conformal Radiation Therapy for Pancreatic Cancer

We assessed dosimetric differences in pancreatic cancer radiotherapy via helical intensity-modulated radiotherapy (HIMRT), linac-based IMRT, and 3D-conformal radiation therapy (3D-CRT) with regard to successful plan acceptance and dose to critical organs. Dosimetric analysis was performed in 16 pancreatic cases that were planned to 54 Gy; both post-pancreaticoduodenectomy (n = 8) and unresected (n = 8) cases were compared. Without volume modification, plans met constraints 75% of the time with HIMRT and IMRT and 13% with 3D-CRT. There was no statistically significantly improvement with HIMRT over conventional IMRT in reducing liver V35, stomach V45, or bowel V45. HIMRT offers improved planning target volume (PTV) dose homogeneity compared with IMRT, averaging a lower maximum dose and higher volume receiving the prescription dose (D100). HIMRT showed an increased mean dose over IMRT to bowel and liver. Both HIMRT and IMRT offer a statistically significant improvement over 3D-CRT in lowering dose to liver, stomach, and bowel. The results were similar for both unresected and resected patients. In pancreatic cancer, HIMRT offers improved dose homogeneity over conventional IMRT and several significant benefits to 3D-CRT. Factors to consider before incorporating IMRT into pancreatic cancer therapy are respiratory motion, dose inhomogeneity, and mean dose.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Pitch and Jaw Width to Decrease Delivery Time of Helical Tomotherapy Treatments for Head and Neck Cancer

Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.86, 0.43, 0.287, and 0.215) were used with a (maximum) modulation factor setting of 4. Twelve plans were generated for each patient using an identical optimization procedure (e.g., number of iterations, objective weights, and penalties, etc.), based on recommendations from TomoTherapy (Madison, WI). The plans were compared using isodose plots, dose volume histograms, dose homogeneity indexes, conformity indexes, radiobiological models, and treatment times. Smaller pitches and jaw widths showed better target dose homogeneity and sparing of normal tissue, as expected. However, the treatment time increased inversely proportional to the jaw width, resulting in delivery times of 24 {+-} 1.9 min for the 1-cm jaw width. Although treatment plans produced with the 2.5-cm jaw were dosimetrically superior to plans produced with the 5-cm jaw, subsequent calculations of tumor control probabilities and normal tissue complication probabilities suggest that these differences may not be radiobiologically meaningful. Because treatment plans produced with the 5-cm jaw can be delivered in approximately half the time of plans produced with the 2.5-cm jaw (5.1 {+-} 0.6 min vs. 9.5 {+-} 1.1 min), use of the 5-cm jaw in routine treatment planning may be a viable approach to decreasing treatment delivery times from helical tomotherapy units.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Results of Helical Tomotherapy in Patients with Complex-Shaped Meningiomas Close to the Optic Pathway

Meningiomas are the most common benign intracranial tumor. Meningiomas close to the optic pathway represent a treatment challenge both for surgery and radiotherapy. The aim of this article is to describe early results of helical tomotherapy treatment in complex-shaped meningiomas close to the optic pathway. Twenty-eight patients were consecutively treated. All patients were immobilized with a thermoplastic head mask and planned with the aid of a magnetic resonance imaging-computed tomography fusion. All treatments included daily image guidance. Pretreatment symptoms and acute toxicity were recorded. Median age was 57.5 years, and 92.8% patients had Eastern Cooperative Oncology Group performance status scale {<=}1. The most common localizations were the sella turcica, followed by the cavernous sinus and the sphenoid. The most common symptoms were derived from cranial nerve deficits. Tomotherapy was administered as primary treatment in 35.7% of patients, as an adjuvant treatment in 32.4%, and as a rescue treatment after postsurgical progression in 32.1% patients. Most patients were either inoperable or Simpson IV. Total dose varied between 5000 and 5400 cGy; fractionation varied between 180 and 200 cGy. Median dose to the planning target volume was 51.7 Gy (range, 50.2-55.9 Gy). Median coverage index was 0.89 (range, 0.18-0.97). Median homogeneity index was 1.05 (range, 1-1.12). Acute transient toxicity was grade 1 and included headache in 35.7% patients, ocular pain/dryness in 28.5%, and radiation dermatitis in 25%. Thus far, with a maximal follow-up of 3 years, no late effects have been seen and all patients have a radiological stabilization of the disease. Helical tomotherapy offered a safe and effective therapeutic alternative for patients with inoperable or subtotally resected complex-shaped meningiomas close to the optic pathway. Acceptable coverage and homogeneity indexes were achieved with appropriate values for maximal doses delivered to the eyes, lenses, and chiasm, despite the proximity of the tumor to these structures.

61 RADIATION PROTECTION AND DOSIMETRY↗