Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High throughput”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

The Advanced Technology Large-Aperture Space Telescope (ATLAST) Technology Roadmap

We present the key technologies and capabilities that will enable a future, large-aperture ultravioletopticalinfrared (UVOIR) space observatory. These include starlight suppression systems, vibration isolation and control systems, lightweight mirror segments, detector systems, and mirror coatings. These capabilities will provide major advances over current and near-future observatories for sensitivity, angular resolution, and starlight suppression. The goals adopted in our study for the starlight suppression system are 10-10 contrast with an inner working angle of 40 milliarcsec and broad bandpass. We estimate that a vibration and isolation control system that achieves a total system vibration isolation of 140 dB for a vibration-isolated mass of 5000 kg is required to achieve the high wavefront error stability needed for exoplanet coronagraphy. Technology challenges for lightweight mirror segments include diffraction-limited optical quality and high wavefront error stability as well as low cost, low mass, and rapid fabrication. Key challenges for the detector systems include visible-blind, high quantum efficiency UV arrays, photon counting visible and NIR arrays for coronagraphic spectroscopy and starlight wavefront sensing and control, and detectors with deep full wells with low persistence and radiation tolerance to enable transit imaging and spectroscopy at all wavelengths. Finally, mirror coatings with high reflectivity ( 90), high uniformity ( 1) and low polarization ( 1) that are scalable to large diameter mirror substrates will be essential for ensuring that both high throughput UV observations and high contrast observations can be performed by the same observatory.

Telescope↗

A Future Large-Aperture UVOIR Space Observatory: Key Technologies and Capabilities

We present the key technologies and capabilities that will enable a future, large-aperture ultravioletopticalinfrared (UVOIR) space observatory. These include starlight suppression systems, vibration isolation and control systems, lightweight mirror segments, detector systems, and mirror coatings. These capabilities will provide major advances over current and near-future observatories for sensitivity, angular resolution, and starlight suppression. The goals adopted in our study for the starlight suppression system are 10-10 contrast with an inner working angle of 20 milliarcsec and broad bandpass. We estimate that a vibration and isolation control system that achieves a total system vibration isolation of 140 dB for a vibration-isolated mass of 5000 kg is required to achieve the high wavefront error stability needed for exoplanet coronagraphy. Technology challenges for lightweight mirror segments include diffraction-limited optical quality and high wavefront error stability as well as low cost, low mass, and rapid fabrication. Key challenges for the detector systems include visible-blind, high quantum efficiency UV arrays, photon counting visible and NIR arrays for coronagraphic spectroscopy and starlight wavefront sensing and control, and detectors with deep full wells with low persistence and radiation tolerance to enable transit imaging and spectroscopy at all wavelengths. Finally, mirror coatings with high reflectivity ( 90), high uniformity ( 1) and low polarization ( 1) that are scalable to large diameter mirror substrates will be essential for ensuring that both high throughput UV observations and high contrast observations can be performed by the same observatory.

Instrument↗

End-to-End Assessment of a Large Aperture Segmented Ultraviolet Optical Infrared (UVOIR) Telescope Architecture

Key challenges of a future large aperture, segmented Ultraviolet Optical Infrared (UVOIR) Telescope capable of performing a spectroscopic survey of hundreds of Exoplanets will be sufficient stability to achieve 10^-10 contrast measurements and sufficient throughput and sensitivity for high yield Exo-Earth spectroscopic detection. Our team has collectively assessed an optimized end to end architecture including a high throughput coronagraph capable of working with a segmented telescope, a cost-effective and heritage based stable segmented telescope, a control architecture that minimizes the amount of new technologies, and an Exo-Earth yield assessment to evaluate potential performance. These efforts are combined through integrated modeling, coronagraph evaluations, and Exo-Earth yield calculations to assess the potential performance of the selected architecture. In addition, we discusses the scalability of this architecture to larger apertures and the technological tall poles to enabling it.

Feinberg, Lee↗

End-to-End Assessment of a Large Aperture Segmented Ultraviolet Optical Infrared (UVOIR) Telescope Architecture

Key challenges of a future large aperture, segmented Ultraviolet Optical Infrared (UVOIR) Telescope capable of performing a spectroscopic survey of hundreds of Exoplanets will be sufficient stability to achieve 10-10 contrast measurements and sufficient throughput and sensitivity for high yield Exo-Earth spectroscopic detection. Our team has collectively assessed an optimized end to end architecture including a high throughput coronagraph capable of working with a segmented telescope, a cost-effective and heritage based stable segmented telescope, a control architecture that minimizes the amount of new technologies, and an Exo-Earth yield assessment to evaluate potential performance.

Feinberg, Lee↗

High mass throughput particle generation using multiple nozzle spraying

Spraying apparatus and methods that employ multiple nozzle structures for producing multiple sprays of particles, e.g., nanoparticles, for various applications, e.g., pharmaceuticals, are provided. For example, an electrospray dispensing device may include a plurality of nozzle structures, wherein each nozzle structure is separated from adjacent nozzle structures by an internozzle distance. Sprays of particles are established from the nozzle structures by creating a nonuniform electrical field between the nozzle structures and an electrode electrically isolated therefrom.

36 MATERIALS SCIENCE↗

Data Storage for HEP Experiments in the Era of High-Performance Computing

As particle physics experiments push their limits on both the energy and the intensity frontiers, the amount and complexity of the produced data are also expected to increase accordingly. With such large data volumes, next-generation efforts like the HL-LHC and DUNE will rely even more on both high-throughput (HTC) and high-performance (HPC) computing clusters. Full utilization of HPC resources requires scalable and efficient data-handling and I/O. For the last few decades, ROOT has been used by most HEP experiments to store data. However, other storage technologies like HDF5 may perform better in HPC environments. Initial explorations with HDF5 have begun using ATLAS, CMS and DUNE data; the DUNE experiment has also adopted HDF5 for its data-acquisition system. This paper presents the future outlook of the HEP computing and the role of HPC, and a summary of ongoing and future works to use HDF5 as a possible data storage technology for the HEP experiments to use in HPC environments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-data throughput reconfigurable computing platform

A reconfigurable computing platform includes a reconfigurable computing device, electro-optical transceiver, and first voltage converter disposed on a multilayer board. The electro-optical transceiver converts an optical signal at least one of to and from an electrical signal, and the electrical signal is operatively coupled to the reconfigurable computing device. The electro-optical transceiver is disposed in proximity to the reconfigurable computing device, and the first voltage converter is operatively coupled to a common voltage distributed around a periphery of the multilayer board. The first voltage converter converts the common voltage to a first operating voltage, and the first voltage converter is disposed in proximity to the reconfigurable computing device. The first operating voltage is provided to the reconfigurable computing device as a first power source. A reconfigurable computing system includes a plurality of reconfigurable computing platforms operatively coupled together using an optical signal. A corresponding method of providing a reconfigurable computing platform is also disclosed.

Tang, Shaochun↗

High mass throughput particle generation using multiple nozzle spraying

Spraying apparatus and methods that employ multiple nozzle structures for producing multiple sprays of particles, e.g., nanoparticles, for various applications, e.g., pharmaceuticals, are provided. For example, an electrospray dispensing device may include a plurality of nozzle structures, wherein each nozzle structure is separated from adjacent nozzle structures by an internozzle distance. Sprays of particles are established from the nozzle structures by creating a nonuniform electrical field between the nozzle structures and an electrode electrically isolated therefrom.

47 OTHER INSTRUMENTATION↗

Single-throughput Complementary High-resolution Analytical Techniques for Characterizing Complex Natural Organic Matter Mixtures

Natural organic matter (NOM) is composed of a highly complex mixture of thousands of organic compounds which, historically, proved difficult to characterize. However, to understand the thermodynamic and kinetic controls on greenhouse gas (carbon dioxide [CO 2 ] and methane [CH 4 ]) production resulting from the decomposition of NOM, a molecular-level characterization coupled with microbial proteome analyses is necessary. Further, climate and environmental changes are expected to perturb natural ecosystems, potentially upsetting complex interactions that influence both the supply of organic matter substrates and the microorganisms performing the transformations. A detailed molecular characterization of the organic matter, microbial proteomics, and the pathways and transformations by which organic matter is decomposed will be necessary to predict the direction and magnitude of the effects of environmental changes. This article describes a methodological throughput for comprehensive metabolite characterization in a single sample by direct injection Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS), gas chromatography mass spectrometry (GC-MS), nuclear magnetic resonance (NMR) spectroscopy, liquid chromatography mass spectrometry (LC-MS), and proteomics analysis. Furthermore, this approach results in a fully-paired dataset which improves statistical confidence for inferring pathways of organic matter decomposition, the resulting CO 2 and CH 4 production rates, and their responses to environmental perturbation. Herein we present results of applying this method to NOM samples collected from peatlands; however, the protocol is applicable to any NOM sample (e.g., peat, forested soils, marine sediments, etc.).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optical designs of reflection and refraction collection optics for a JT-60SA core Thomson scattering system

Collection optics for core measurements in a JT-60SA Thomson scattering system were designed. The collection optics will be installed in a limited space and have a wide field of view and wide wavelength range. Two types of the optics are therefore suggested: refraction and reflection types. The reflection system, with a large primary mirror, avoids large chromatic aberrations. Because the size limit of the primary mirror and vignetting due to the secondary mirror affect the total collection throughput, conditions that provide the high throughput are found through an optimization. A refraction system with four lenses forming an Ernostar system is also employed. The use of high-refractive-index glass materials enhances the freedom of the lens curvatures, resulting in suppression of the spherical and coma aberration. Moreover, sufficient throughput can be achieved, even with smaller lenses than that of a previous design given in [H. Tojo, T. Hatae, T. Sakuma, T. Hamano, K. Itami, Y. Aida, S. Suitoh, and D. Fujie, Rev. Sci. Instrum. 81, 10D539 (2010)]. The optical resolutions of the reflection and refraction systems are both sufficient for understanding the spatial structures in plasma. In particular, the spot sizes at the image of the optics are evaluated as ∼0.3 mm and ∼0.4 mm, respectively. The throughput for the two systems, including the pupil size and transmissivity, are also compared. The results show that good measurement accuracy (<10%) even at high electron temperatures (<30 keV) can be expected in the refraction system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-stage dynamic deregulation of metabolism improves process robustness & scalability in engineered E. coli.

Here, we report that two-stage dynamic control improves bioprocess robustness as a result of the dynamic deregulation of central metabolism. Dynamic control is implemented during stationary phase using combinations of CRISPR interference and controlled proteolysis to reduce levels of central metabolic enzymes. Reducing the levels of key enzymes alters metabolite pools resulting in deregulation of the metabolic network. Deregulated networks are less sensitive to environmental conditions improving process robustness. Process robustness in turn leads to predictable scalability, minimizing the need for traditional process optimization. We validate process robustness and scalability of strains and bioprocesses synthesizing the important industrial chemicals alanine, citramalate and xylitol. Predictive high throughput approaches that translate to larger scales are critical for metabolic engineering programs to truly take advantage of the rapidly increasing throughput and decreasing costs of synthetic biology.

59 BASIC BIOLOGICAL SCIENCES↗

Optimized Incorporation of Furan into Diketopyrrolopyrrole-Based Conjugated Polymers for Organic Field-Effect Transistors

Flexible electronics have received considerable attention in the past decades due to their promising application in rollable display screens, wearable devices, implantable devices, and other electronic applications. Here, in particular, conjugated polymers are favored for flexible electronics due to their mechanical flexibility and potential for solution-processed fabrication techniques, such as blade-coating, roll-to-roll printing, and high-throughput printing allowing for high-performance transistor devices. Thiophene is the prevailing conjugated unit to construct these conjugated polymers due to its favorable electronic properties. On the other hand, furans are among the few conjugated moieties that are easily derived from bio renewable resources. To promote sustainability, we selectively introduced furan into the conjugated backbone of a high-mobility polymer scaffold and systematically studied the effect on the microstructure and charge transport. We show that partially and selectively replacing thiophene units with furan can yield nearly comparable performance compared to the all-thiophene polymer. This strategy offers an improvement in the sustainability of the polymer by incorporating bio-sourced furan without sacrificing the high-performance characteristics. Meanwhile, polymers with incorrect or complete furan incorporation show reduced mobilities. This work serves to develop coherent structure–morphology–performance relationships; such knowledge will establish guidelines for the future development of sustainable, furan-based conjugated materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

TES X-ray Spectrometer at SLAC LCLS-II

We are building a transition edge sensor (TES) X-ray spectrometer for the Linac Coherent Light Source (LCLS-II) at SLAC National Accelerator Laboratory (SLAC) to coincide with new upgrades for this free electron laser facility. This new X-ray spectrometer will have 1000 TES pixels with 0.5 eV energy resolution for soft X-rays below 1 keV. Multiplexing will be done with microwave SQUID resonators and new specialized electronic hardware developed at SLAC. This spectrometer will use a dilution refrigerator to achieve lower operating temperatures than previous TES spectrometers and will be coupled to the liquid jet endstation at LCLS-II. The spectrometer is designed to operate at much higher count rates than previous TES X-ray spectrometers to take advantage of the high repetition rate of the LCLS-II. Science applications will utilize the high photon collection efficiency and throughput, high energy resolution, as well as its ability to simultaneously measure its full calibrated energy range.

47 OTHER INSTRUMENTATION↗

Sorting for secreted molecule production using a biosensor-in-microdroplet approach

Significance The design–build–test cycle of metabolic engineering is swiftly becoming test limited owing to advances in DNA synthesis and library design. At the same time, improving extracellular production requires high-throughput studies to detect extracellular (not intracellular) content. Traditional approaches that utilize chromatography-based analysis or plate-based fluorescence assays are relatively throughput limited and require a high degree of liquid handling. These limitations are avoided here by creating a generalizable approach for small molecule production screening. Namely, this paradigm combines “off-the-shelf” biosensors with large library screening from producing cells in a cell-type agnostic manner.

Bowman, Emily K.↗

Mechanisms of a novel regulatory light chain–dependent cardiac myosin inhibitor

Hypertrophic cardiomyopathy (HCM) is a genetic disease of the heart characterized by thickening of the left ventricle (LV), hypercontractility, and impaired relaxation. HCM is caused primarily by heritable mutations in sarcomeric proteins, such as β myosin heavy chain. Until recently, medications in clinical use for HCM did not directly target the underlying contractile changes in the sarcomere. Here, we investigate a novel small molecule, RLC-1, identified in a bovine cardiac myofibril high-throughput screen. RLC-1 is highly dependent on the presence of a regulatory light chain to bind to cardiac myosin and modulate its ATPase activity. In demembranated rat LV trabeculae, RLC-1 decreased maximal Ca2+-activated force and Ca2+ sensitivity of force, while it increased the submaximal rate constant for tension redevelopment. In myofibrils isolated from rat LV, both maximal and submaximal Ca2+-activated force are reduced by nearly 50%. Additionally, the fast and slow phases of relaxation were approximately twice as fast as DMSO controls, and the duration of the slow phase was shorter. Structurally, x-ray diffraction studies showed that RLC-1 moved myosin heads away from the thick filament backbone and decreased the order of myosin heads, which is different from other myosin inhibitors. In intact trabeculae and isolated cardiomyocytes, RLC-1 treatment resulted in decreased peak twitch magnitude and faster activation and relaxation kinetics. In conclusion, RLC-1 accelerated kinetics and decreased force production in the demembranated tissue, intact tissue, and intact whole cells, resulting in a smaller cardiac twitch, which could improve the underlying contractile changes associated with HCM.

Physiology↗

Evaluation of advanced polymers for additive manufacturing

The goal of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Oak Ridge National Laboratory (ORNL) and PPG Industries, Inc. was to evaluate the feasibility of using conventional coatings chemistry and technology to build up material layer-by-layer. The PPG-ORNL study successfully demonstrated that polymeric coatings formulations may overcome many limitations of common thermoplastics used in additive manufacturing (AM), allow lightweight nozzle design for material deposition and increase build rate. The materials effort focused on layer-by-layer deposition of coatings with each layer fusing together. The combination of materials and deposition results in an additively manufactured build that has sufficient mechanical properties to bear the load of additional layers, yet is capable of bonding across the z-layers to improve build direction strength. The formulation properties were tuned to enable a novel, high-throughput deposition method that is highly scalable, compatible with high loading of reinforcing fillers, and is inherently low-cost.

36 MATERIALS SCIENCE↗

Evaluation of Advanced Polymers for Additive Manufacturing

The goal of this Manufacturing Demonstration Facility (MDF) technical collaboration project between Oak Ridge National Laboratory (ORNL) and PPG Industries, Inc. (PPG) was to evaluate the feasibility of using conventional coatings chemistry and technology to build up material layer-by-layer. The PPG-ORNL study successfully demonstrated that polymeric coatings formulations may overcome many limitations of common thermoplastics used in additive manufacturing (AM), allow lightweight nozzle design for material deposition, and increase build rate. The materials effort focused on layer-by-layer deposition of coatings with each layer fusing together. The combination of materials and deposition results in an additively manufactured build that has sufficient mechanical properties to bear the load of additional layers, yet is capable of bonding across the z-layers to improve build direction strength. The formulation properties were tuned to enable a novel, high-throughput deposition method that is highly scalable, compatible with high loading of reinforcing fillers, and inherently low-cost.

36 MATERIALS SCIENCE↗