Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Handling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Stretchable Mould Interconnect Optimization: Peeling Automation and Carrierless Techniques

The primary bottleneck of the stretchable mold interconnect (SMI) technology is its reliance on carrier boards. These are necessary to handle the meandered circuit during production and to ensure dimensional stability of the flexible circuit board before encapsulation. However, for all the problems it solves, it also introduces a new major problem by requiring a peeling step – which is difficult to automate. This manuscript aims to present some of the work that went into eliminating this problem, discussing both unsuccessful and functioning methods to tackle this conundrum and some of the experimental work that went into verifying these techniques. First, alterations to the design to simplify peeling are considered, followed by adhesivebased peeling processes and mechanical pin-based systems. Next, masking and structuring of the carrier board adhesive are considered. Finally, two carrierless methods which circumvent the problems are discussed, a two-step process – which cuts temporary support structures after partial encapsulation – and a technique whereby the frame is designed to fail in a controlled manner during the first use of the circuit, creating a carrierless process feasible for high-volume production.

Plovie, Bart↗

An Algorithm of an X-ray Hit Allocation to a Single Pixel in a Cluster and Its Test-Circuit Implementation

An on-chip implementable algorithm for allocation of an X-ray photon imprint, called a hit, to a single pixel in the presence of charge sharing in a highly segmented pixel detector is described. Its proof-of-principle implementation is also given supported by the results of tests using a highly collimated X-ray photon beam from a synchrotron source. The algorithm handles asynchronous arrivals of X-ray photons. Activation of groups of pixels, comparisons of peak amplitudes of pulses within an active neighborhood and finally latching of the results of these comparisons constitute the three procedural steps of the algorithm. A grouping of pixels to one virtual pixel, that recovers composite signals and event driven strobes, to control comparisons of fractional signals between neighboring pixels are the actuators of the algorithm. The circuitry necessary to implement the algorithm requires an extensive inter-pixel connection grid of analog and digital signals, that are exchanged between pixels. A test-circuit implementation of the algorithm was achieved with a small array of 32 × 32 pixels and the device was exposed to an 8 keV highly collimated to a diameter of 3-μm X-ray beam. Furthermore, the results of these tests are given in this paper assessing physical implementation of the algorithm.

47 OTHER INSTRUMENTATION↗

Privacy-Assured Aggregation Protocol for Smart Metering: A Proactive Fault-Tolerant Approach [Proactive Fault-Tolerant Aggregation Protocol for Privacy-Assured Smart Metering]

Smart meters are integral to demand response in emerging smart grids, by reporting the electricity consumption of users to serve application needs. But reporting real-time usage information for individual households raises privacy concerns. Existing techniques to guarantee differential privacy (DP) of smart meter users either are not fault tolerant or achieve (possibly partial) fault tolerance at high communication overheads. In this paper, we propose a fault-tolerant protocol for smart metering that can handle general communication failures while ensuring DP with significantly improved efficiency and lower errors compared with the state of the art. Our protocol handles fail-stop faults proactively by using a novel design of future ciphertexts, and distributes trust among the smart meters by sharing secret keys among them. We prove the DP properties of our protocol and analyze its advantages in fault tolerance, accuracy, and communication efficiency relative to competing techniques. We illustrate our analysis by simulations driven by real-world traces of electricity consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detailed Modeling and Evaluation of a Scalable Multilevel Checkpointing System

High-performance computing (HPC) systems are growing more powerful by utilizing more components. As the system mean time before failure correspondingly drops, applications must checkpoint frequently to make progress. But, at scale, the cost of checkpointing becomes prohibitive. A solution to this problem is multilevel checkpointing, which employs multiple types of checkpoints in a single run. Moreover, lightweight checkpoints can handle the most common failure modes, while more expensive checkpoints can handle severe failures. We designed a multilevel checkpointing library, the Scalable Checkpoint/Restart (SCR) library, that writes lightweight checkpoints to node-local storage in addition to the parallel file system. We present probabilistic Markov models of SCR's performance. We show that on future large-scale systems, SCR can lead to a gain in machine efficiency of up to 35 percent, and reduce the load on the parallel file system by a factor of two. In addition, we predict that checkpoint scavenging, or only writing checkpoints to the parallel file system on application termination, can reduce the load on the parallel file system by 20 × on today's systems and still maintain high application efficiency.

97 MATHEMATICS AND COMPUTING↗

A Robust State Estimation Framework Considering Measurement Correlations and Imperfect Synchronization

This paper develops a robust power system state estimation framework with the consideration of measurement correlations and imperfect synchronization. In the framework, correlations of SCADA and PMU measurements are calculated separately through unscented transformation and a vector autoregression (VAR) model. In particular, PMU measurements during the waiting period of two SCADA measurement scans are buffered to develop the VAR model. The latter takes into account the temporal and spatial correlations of PMU measurements and provides redundant measurements to suppress bad data and mitigate imperfect synchronization. In case of synchronization issues between SCADA and PMU measurements, either forecasted PMU measurements or prior SCADA measurements from the last estimation run are leveraged to restore system observability. After that, robust generalized maximum-likelihood (GM)-estimator is developed to integrate full measurement correlations and handle bad data in SCADA and PMU measurements. Thanks to the robustness and flexibility of the proposed robust estimator, bad data as well as imperfect measurement synchronization are mitigated, yielding high statistical efficiency. Comprehensive comparison results with other alternatives under various conditions demonstrate the benefits of the proposed framework.

Zhao, Junbo (ORCID:0000000284989666)↗

A robust dynamic state estimation approach against model errors caused by load changes

Dynamic state estimation (DSE) plays an important role in power system security monitoring and online control. In practice, there are two approaches to implementing DSE. The first approach is distributed DSE, which is based on the assumption that the terminal bus of each generator can be measured by PMUs (phasor measurement units). The assumption cannot be satisfied currently, however, because PMUs usually are installed at important high-voltage buses such as 500-kV buses installed in portions of the grid overseen by the Western Electricity Coordinating Council. Another issue of this approach is that performance of DSE is vulnerable to bad measurement data. The reason for this vulnerability is that DSE is performed separately through measurements at each terminal bus, and measurements at terminal buses are the only measurement upon which DSE can rely. Therefore, important redundant measurements are not included in this approach. The second approach is centralized DSE. This approach does not have the requirement for PMU location, and redundant measurements can be considered fully. However, load changes and grid topology changes impact centralized DSE. In this paper, we propose a new approach for handling the impact of load changes on DSE. We have developed a new algorithm that includes two sequential steps. In the first step, errors caused by load changes are detected by analyzing the difference between prediction results and measured results. In the second step, once model error is detected, a model optimization procedure is run to correct the error so the state estimation error can be mitigated. Simulation results from the IEEE 68 bus system show that the proposed approach can effectively handle model errors caused by load changes.

robust dynamic state estimation, load change, powe↗

Risk Assessment of Rare Events in Probabilistic Power Flow via Hybrid Multi-Surrogate Method

The risks associated with rare events threatening the security of power system operation are of paramount importance to power system planners and operators. To analyze the risks caused by high-impact, low-frequency rare events, an immensely large number of samples are typically required for the Monte-Carlo (MC) method on the high-fidelity power system model to achieve a sufficient accuracy, thereby rendering this approach computationally prohibitive. To handle this problem efficiently, it is desirable to construct a surrogate model for the power system response. However, the straightforward MC sampling of the low-fidelity surrogate can lead to biased results in the low-probability tail regions that are vital to risk assessment. Moreover, a single surrogate is unable to handle the topology uncertainties caused by random branch outages. To overcome these issues, we propose a hybrid multi-surrogate (HMS) method based on the polynomial chaos expansion (PCE) with low-probability tail events reevaluated by the high-fidelity model through a probabilistic analysis. This method improves the computational efficiency of the MC method for rare-event risk assessment by leveraging multi-fidelity models while retaining the desired accuracy. Simulations conducted in three test systems verify the excellent performances of the HMS method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Day-Ahead Optimal Operation for Multi-Energy Residential Systems with Renewables

The intermittency and stochasticity nature of distributed renewable energy sources has introduced great challenges to the efficiency and security of energy distribution system operations. To address the negative impacts of intermittent renewable energy sources, this paper proposes here a day-ahead optimal operation strategy utilizing distributed energy resources based on the framework of the interconnected multi-energy system. First, a framework and mathematical models of multi-energy residential systems (MERS) are proposed. Based on the characteristics of residential energy distribution networks, the complex MERS models are reformulated to relieve the computational burden. Furthermore, the uncertainty factors such as renewable energy generation fluctuations and demand variations are handled by a reformulated chance con-strained programming technique. The feasibility and effectiveness of the proposed method are validated through a combined electric power and natural gas test system. Compared to similar models and methods in the existing literature, the proposed method performs better in terms of solution time, model scalability, and robustness in handling uncertainties.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Comprehensive Calibration Framework for the Northwest River Forecast Center

We present a comprehensive framework developed by the Northwest River Forecast Center for calibrating hydrologically diverse basins. The framework includes models for snow, soil moisture, routing, channel loss, and consumptive use. Data inputs include a wide range of open-access datasets for meteorology, land use, topography, and land cover. The framework uses conceptual hydrologic models to handle basins with various hydrologic regimes including rain-driven and snowmelt-dominated basins. We also develop a flexible automatic calibration system that can handle numerous unobservable model parameters in a computationally efficient manner. A single-basin automatic calibration run can typically be completed on a modern laptop in under 10 min. We found that model performance metrics for this new approach match the quality of the NWRFC's previous labor-intensive manual calibrations. The model performance also rivals that of a state-of-the-art deep learning model at a fraction of the computational cost. This framework presents a new standard for the quality of calibrations possible with lumped conceptual hydrologic models, combining careful data curation, an objective calibration framework, and expert local knowledge. In addition, we have made software packages available for the entire suite of National Weather Service River Forecast System models, including SAC-SMA, SNOW-17, and Lag-K. These modern interfaces are intended to increase accessibility and facilitate future research.

Forecasting↗

Human Factors in Streaming Data Analysis: Challenges and Opportunities for Information Visualization: Human Factors in Streaming Data Analysis

State-of-the-art visual analytics models and frameworks mostly assume a static snapshot of the data, while in many cases it is a stream with constant updates and changes. Exploration of streaming data poses unique challenges as machine-level computations and abstractions need to be synchronized with the visual representation of the data and the temporally evolving human insights. In the visual analytics literature, we lack a thorough characterization of streaming data and analysis of the challenges associated with task abstraction, visualization design, and adaptation of the role of human-in-the-loop for exploration of data streams. We aim to fill this gap by conducting a survey of the state-of-the-art in visual analytics of streaming data for systematically describing the contributions and shortcomings of current techniques and analyzing the research gaps that need to be addressed in the future. Our contributions are: i) problem characterization for identifying challenges that are unique to streaming data analysis tasks, ii) a survey and analysis of the state-of-the-art in streaming data visualization research with a focus on the visualization design space for dynamic data and the role of the human-in-the-loop, and iii) reflections on the design-trade-offs for streaming visual analytics techniques and their practical applicability in real-world application scenarios.

streaming data↗

A Statistical Evaluation of Combining Human Productivity Metrics in the Indoor Environment

The potential of improving human productivity by providing healthy indoor environments has been a consistent interest in the building field for decades. This research field's long-standing challenge is to measure human productivity given the complex nature of office work. Previous studies have diversified productivity metrics, allowing greater flexibility in collecting human data; however, this diversity complicates the ability to combine productivity metrics from disparate studies within a meta-analysis. This study aims to categorize existing productivity metrics and statistically assess which categories show similar behavior when used to measure the impacts of indoor environmental quality. The 106 productivity metrics compiled were grouped into six productivity metric categories: neurobehavioral speed, accuracy, neurobehavioral response time, call handling time, self-reported productivity, and performance score. Then, this study set neurobehavioral speed as the baseline category given its fitness to the efficiency-based definition of productivity (i.e., output versus input) and conducted three statistical analyses with the other categories to evaluate their similarity. As results, the categories of neurobehavioral response time, self-reported productivity, and call handling time were found to have statistical similarity with neurobehavioral speed. This study contributes to creating a constructive research environment for future meta-analyses to understand which human productivity metrics can be combined with each other.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of evaluation models of manpower needs for dismantling the dry conversion process-related equipment in uranium refining and conversion plant (URCP)

Evaluation models for determining the manpower needs for dismantling various types of equipment in uranium refining and conversion plant (URCP) have been developed. The models are widely applicable to other uranium handling facilities. Additionally, a simplified model was developed for easily and accurately calculating the manpower needs for dismantling dry conversion process-related equipment (DP equipment). It is important to evaluate beforehand project management data such as manpower needs to prepare an optimized decommissioning plan and implement effective dismantling activity. The Japan Atomic Energy Agency (JAEA) has developed the project management data evaluation system for dismantling activities (PRODIA code), which can generate project management data using evaluation models. For preparing an optimized decommissioning plan, these evaluation models should be established based on the type of nuclear facility and actual dismantling data. In URCP, the dry conversion process of reprocessed uranium and others was operated until 1999, and the equipment related to the main process was dismantled from 2008 to 2011. Actual data such as manpower for dismantling were collected during the dismantling activities, and evaluation models were developed using the collected actual data on the basis of equipment classification considering the characteristics of uranium handling facility. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cadarache LOR (liquides organiques radioactifs) treatment by a solidification process using NOCHAR polymers

In France, two options can be considered to handle the Very Low Level Waste (VLLW) and the Low Level Waste (LLW). The first one is the incineration at CENTRACO facility and the second one is the disposal at ANDRA sites. The waste acceptance in these two channels is dependent upon the adequacy between the waste characteristics (physical chemistry and radiological) and the channel specifications. If the waste characteristics and the channel specifications (presence of significant quantities of halogens, complexing agents, organic components... or/and high activity limits) are incompatible, an alternative solution have to be identify. It consists of a waste pre-treatment process. For Cadarache LOR (Liquides Organiques Radioactifs) waste streams, two radioactive scintillation cocktails have to be treated. They are composed of a mix of organic liquids and water: for the first one, 19 % of organic compounds (xylene, mesitylene, diphenyloxazole, TBP...) and 86.9 % of water, and for the second one, 23 % of organic compounds (TBP...) and 77 % of water. They contain halogens (chlorine and fluorine), complexants agents (nitrate, sulphate, oxalate and formate) and have got αβγ spectra with mass activities equal to some 100 Bq/g. Therefore, tritium is also present. As a consequence, in order for storage acceptance at the ANDRA site, it is necessary to pre-treat the waste. An adequate solution seems to be a solidification process using NOCHAR polymers. Indeed, NOCHAR polymers correspond to an important variety of products applied to the treatment of radioactive aqueous and organic liquids (solvent, oil, solvent/oil mixing ...) and sludge through a mechanical and chemical solidification process. For Cadarache LOR, N910 and N960 respectively dedicated to the organic and aqueous liquids solidification are considered. With the N910, the organic waste solidification occurs in two steps. As the organic liquid travels moves through the polymer strands, the strands swell and immobilize the liquid. Then as the polymer-organic cure, over time, the polymer continues to collapse on the organic to create a permanent chemical bond. The N960 has the ability to absorb aqueous waste up to 100 times its own weight. It creates a strong mechanical bond which permanently traps the contamination imbedded in the aqueous liquids. Therefore, these two NOCHAR polymers seem to be able to constitute a suitable solidification matrix for a final acceptance in storage on ANDRA sites. In order to validate the solidification process using NOCHAR polymers as an acceptable solution for Cadarache LOR treatment, some solidification tests realised with N910 and N960, have been carried out for different Waste/Polymer ratios. To determine the best Waste/Polymer ratio and the optimal experimental parameters, exudation tests have been made. Indeed, the process prevents leaching and it results in the absence residual free organic or aqueous liquid which is forbidden in storage by ANDRA specifications. With these results, the obtained scientific data constitute a fundamental basis of an ANDRA agreement. As a conclusion, the aim of this study is to demonstrate that the pre-treatment by solidification using NOCHAR polymers can constitute a solution for Cadarache LOR handling and more generally, for various organic and mixed organic/aqueous waste which can not be directly acceptable at CENTRACO facility or at ANDRA storage sites. So then, this study is a solid background to demonstrate the feasibility of the waste pre-treatment by solidification with NOCHAR polymer and to encourage this process development. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Unique and massive Chernobyl cranes for deconstruction activities in the new safe confinement

On 26 April 1986, the worst nuclear power plant accident in history occurred at the Chernobyl plant in Ukraine (then part of the Soviet Union). The destruction of Unit 4 sent highly radioactive fallout over Belarus, Russia, Ukraine, and Europe. The object shelter-a containment sarcophagus-was built in November 1986 to limit exposure to radiation. However, it has only a planned 25-year lifespan and would probably not survive even a moderate seismic event in a region that has more than its share of such events. It was time to take action. One of the largest tasks that are in progress is the design and construction of the New Safe Confinement (NSC). The NSC is an engineered enclosure for the entire object shelter that includes a suite of process equipment. The process equipment will be used for the dismantling of the destroyed Chernobyl Nuclear Power Plant Unit. One of the major mechanical handling systems to be installed in the new safe confinement is the Main Cranes System. The planned decontamination and decommissioning or dismantling activities will require the handling of heavily shielded waste disposal casks containing nuclear fuel as well as lifting and transporting extremely large structural elements. These activities, to be performed within the new safe confinement, will require large and sophisticated cranes. The article will focus on the current progress of the new safe confinement and of the main cranes system for the decommissioning or dismantling activities. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

AN APPROACH TO BRINGING AUTOMATED FAULT DETECTION AND DIAGNOSIS (AFDD) TOOLS FOR HVAC&R INTO THE MAINSTREAM

Heating, ventilation and air-conditioning (HVAC) systems can consume over 5 quads of energy annually, representing 30% of energy consumption in the U.S. in commercial buildings. Additionally, commercial refrigeration (R) systems add about 2 quads to commercial buildings energy consumption. Most HVAC systems have one or more faults (low/high refrigerant charge, valve leakage, condenser/evaporator fouling, filter/dryer restriction, economizer faults, controls faults) that result in increased energy consumption. Automated fault detection and diagnosis (AFDD) tools have been developed to address this national issue and many tools are commercially available. AFDD tools have the potential to save considerable energy for existing commercial RTUs, chillers and refrigeration systems. These devices can be used for both retro commissioning, and, when faults are addressed, continuous commissioning as well. However, there appears to be multiple market barriers for this technology. A key market barrier for this technology is the lack of awareness of AFDD products among potential customers. Most HVAC contractors are not familiar with the latest AFDD technologies and HVAC technicians lack skills regarding these technologies. Quantifying potential benefits to building owners is difficult since there are several FDD tools with varying capabilities. For instance, there are several FDD products ranging from handling just economizer faults to those that also handle full-blown refrigerant-side and air-side faults. Methods/algorithms used in FDD vary significantly. Even though there are efforts to develop standards, currently there are no standards/methods to define functions, capabilities, accuracy, and reliability of FDD tools. Moreover, most of the commercial AFDD tools have not been verified in the field independently. This paper presents a comprehensive approach to bringing HVAC AFDD tools into the mainstream. The approach involves demonstrating ten commercially available tools at ten different sites, independent testing and evaluation of the FDD tools, communication with various stakeholders, identifying market barriers, and assisting utility companies in developing incentive programs. This paper presents selection of AFDD tools, ite identification, and field testing and evaluation method.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Numerical Analysis on Hydraulic Power Take-Off for Wave Energy Converter and Power Smoothing Methods: Preprint

One of the primary challenges for wave energy converter (WEC) systems is the fluctuating nature of wave resources, which require the WEC components to be designed to handle loads (i.e., torques, forces, and powers) that are many times greater than the average load. This approach requires a much greater power take-off (PTO) capacity than the average power output and indicates a higher cost for the PTO. Moreover, additional design requirements, such as battery storage, are needed, particularly for practical electrical grid connection, and can be a problem for sensitive equipment (e.g., radar, computing devices, and sensors). Therefore, it is essential to investigate potential methodologies to reduce the overall power fluctuation while trying to optimize the power output from WECs. In this study, a detailed hydraulic PTO model was developed and coupled with a time-domain hydrodynamics model (WEC-Sim) to evaluate the PTO efficiency for WECs and the trade-off between power output and fluctuation using different power smoothing methods, including energy storage, pressure relief mechanism, and a powerbased setpoint control method. The study also revealed that the maximum power fluctuation for WECs can be significantly reduced by one order of magnitude when these power smoothing methods are applied.

16 TIDAL AND WAVE POWER↗

Tuning of Nacelle Feedback Gains for Floating Wind Turbine Controllers Using a Two-DOF Model

Designing a collective blade pitch controller for floating offshore wind turbines (FOWTs) poses unique challenges due to the interaction of the controller with the dynamics of the platform. The controller must also handle the competing objectives of power production performance and fatigue load management. Existing solutions either detune the controller with the result of slowed response, make use of complicated tuning methods, or incorporate a nacelle velocity feedback gain. With the goal of developing a simple control tuning method for the general FOWT researcher that is easily extensible to a wide array of turbine and hull configurations, this last idea is built upon by proposing a simple tuning strategy for the feedback gain. This strategy uses a two degree-of-freedom (DoF) turbine model that considers tower-top fore-aft and rotor angular displacements. For evaluation, the nacelle velocity term is added to an existing gain scheduled proportional-integral controller as a proportional gain. The modified controller is then compared to baseline land-based and detuned controllers on an example system for several load cases. First-pass results are favorable, demonstrating how researchers can use the proposed tuning method to efficiently schedule gains for adequate controller performance as they investigate new FOWT configurations.

49 EE - Wind and Water Power Program - Wind (EE-4W↗

Umbilical Fatigue Analysis for a Wave Energy Converter

Unique umbilical designs for wave energy converters (WECs), including the ability to handle significantly larger motions and loads over long deployments, are often required when conventional marine umbilical designs for offshore oil and gas and offshore wind may not meet the design and cost needs of wave energy technologies. This study details a fatigue analysis of a dynamic power umbilical attached to a two-body floating point absorber WEC system, using the sea states provided for the PacWave testing facilities. The 6 degrees of freedom motion time history for the WEC was simulated, and the motions of the attachment point for the umbilical on the WEC and respective sea states were used to analyze the dynamic motions and fatigue of the connected power umbilical to predict the fatigue life. The results show that the fatigue damage observed is more significant in shallow water, and extensive fatigue damage may occur because of the larger curvature response of the umbilical. The umbilical configurations departing at 90 deg off incoming waves were found to have the highest fatigue life attributed to less extension or compression of the umbilical. However, additional bend stiffener/limiter features may need to be incorporated into the buoyancy section and touchdown regions to minimize curvature-induced fatigue.

50 EE - Wind and Water Power Program - Water (EE-4↗