Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUORIDES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,693 records · Page 94

Hugoniot Models for Na and LiF from LEOS

In this document, we provide the Hugoniot for sodium from two models: LEOS table L110 and Lynx table 110. We also provide the Hugoniot for lithium fluoride from LEOS (L2240) and Lynx (2240). The Hugoniot pressures are supplied for temperatures between 338.0 and 1.16×10 9 Kelvin and densities between 0.968 and 11.5 g/cc. These LEOS models were developed by the quotidian EOS methodology, which is a widely used and robust method for producing tabular EOS data. Tables list the model data for LEOS 110, Lynx 110, LEOS 2240, and Lynx 2240. The Lynx models follow the same methodology as the LEOS models; however, the Purgatorio average-atom DFT code was used to compute the electron thermal part of the EOS. The models for Lynx are only listed at high compression due to known issues with the Lynx library at lower pressures.

36 MATERIALS SCIENCE↗

Nevada National Security Site 2018 Data Report: Groundwater Monitoring Program, Area 5 Radioactive Waste Management Site

This report is a compilation of the groundwater and waste cell leachate sampling results from the Area 5 Radioactive Waste Management Site (RWMS) at the Nevada National Security Site, Nye County, Nevada. Groundwater samples from the aquifer immediately below the Area 5 RWMS have been collected and analyzed and static water levels have been measured in this aquifer since 1993. These groundwater data are evaluated for evidence of effects on the aquifer related to the Area 5 RWMS. Leachate from one lined mixed waste cell at the Area 5 RWMS (Cell 18) has been sampled since the cell opened in 2011. These leachate data are analyzed for hazardous contaminants to determine appropriate leachate handling and disposal. A second lined mixed waste cell at the Area 5 RWMS (Cell 25) began receiving waste in August 2018, but no leachate samples were collected or analyzed during 2018. This report includes data from 2014 through 2018 but focuses on the 2018 data. During 2018, groundwater samples were collected and static water levels were measured at three wells surrounding the Area 5 RWMS. Groundwater samples were collected at wells UE5PW-1, UE5PW-2, and UE5PW-3 on March 6 and August 14, 2018. Static water levels were measured at each of these wells on March 5, June 4, August 13, and October 25, 2018. Groundwater monitoring at the Area 5 RWMS complies with Title 40 Code of Federal Regulations (CFR) Part 264.97, General ground-water monitoring requirements , and 40 CFR 264.98, Detection monitoring program. Groundwater samples were analyzed for indicators of contamination (pH, specific conductance [SC], total organic carbon, total organic halides, and tritium) and, beginning in 2017, toxicity characteristic metals (arsenic, barium, cadmium, chromium, lead, mercury, selenium, and silver). General water chemistry parameters (calcium, iron, magnesium, manganese, potassium, sodium, sulfate, chloride, fluoride, bicarbonate, and silicate) were also measured. Results from samples collected in 2018 are within the limits for each parameter established by the Nevada Division of Environmental Protection in Resource Conservation and Recovery Act (RCRA) Permit NEV HW0101, Revision 6. Data from the shallow aquifer indicate there has been no measurable impact to the uppermost aquifer from the Area 5 RWMS, and there were no significant changes in measured groundwater parameters compared to previous years. Leachate from lined mixed waste Cell 18 drains into a sump and is pumped into an above ground tank. Samples are collected from the tank when the leachate volume approaches the 3,000-gallon tank capacity. During 2018, leachate samples were collected on March 1, 2018 and August 1, 2018. All leachate analysis results are below the regulatory levels for toxicity characteristic contaminants (40 CFR 261.24) and below the investigation levels for polychlorinated biphenyls (PCBs), tritium, pH, and SC specified in RCRA Permit NEV HW0101, Revision 6. No quantifiable PCB levels were detected in any leachate sample. Based on the leachate analysis results, RCRA Permit NEV HW0101 allowed all leachate collected from Cell 18 to be pumped from the collection tank and used for dust control at Cell 18.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Integrated Fuel Cycle Materials and Chemistry Program (FY21 Plutonium Science Task Report)

Task 2 of the IFCMCP was designed to utilize vibrational spectroscopy, microscopy, X-ray diffraction, and calorimetry to explore the spectroscopic, structural, and chemical properties of plutonium compounds relevant to the nuclear fuel cycle. An important precursor to this work is production of fresh, high-quality plutonium samples. Given the health hazards and material accountability associated with plutonium, sample production is not trivial and production experiments require extensive planning and coordination by research and support staff. Further, because alpha-emissions from plutonium produce time- and dose dependent radiolysis resulting in structural defects, particularly in the presence of water, freshly prepared plutonium samples must be carefully packaged and analyzed with urgency following their production. In FY21, SRNL and UND engaged in numerous research studies involving production and subsequent characterization of plutonium dioxide, plutonium fluoride, plutonium oxalate, and plutonium nitrate. Specific efforts involving each of these compounds are described in detail in the body of this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Triboelectric Nanogenerator Repeatability and Reproducibility Study

The development of triboelectric nanogenerators (TENGs) has largely focused on optimizing output performance, often at the expense of other critical research considerations such as the development of reliable technical procedures. In particular, the reliability of reported results—specifically repeatability and reproducibility—remains underexplored and is frequently limited to brief discussion within available literature. Without rigorous validation through repeatability and reproducibility studies, the credibility and broader applicability of reported findings remain uncertain. This study addresses this gap by systematically evaluating the repeatability and reproducibility of TENG performance data. Five polymer materials—Kapton, polyethylene (PE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyvinylidene fluoride (PVDF)—were investigated across all pairwise combinations of 25 total combinations for the reproducibility study and three selected pairs of the 25 samples were selected for the repeatability study. For each TENG pairing, we analyzed the methodology, experimental procedures, and resulting performance data to quantify consistency and reliability. The objective of this work is to assess the validity of the collected dataset and determine whether the observed performance trends are consistent for use in future TENG design and optimization studies. Establishing reliable and reproducible data is essential for advancing the development of high-output TENG systems and ensuring their dependable implementation in practical applications.

36 MATERIALS SCIENCE↗

Flexible Conversion Ratio Fast Reactor Systems Evaluation

Conceptual designs of lead-cooled and liquid salt-cooled fast flexible conversion ratio reactors were developed. Both concepts have cores reated at 2400 MWt placed in a large-pool-type vessel with dual-free level, which also contains four intermediate heat exchanges coupling a primary coolant to a compact and efficient supercritical CO2 Brayton cycle power conversion system. Decay heat is removed passively using an enhanced Reactor Vessel Auxiliary Cooling System and a Passive Secondary Auxiliary Cooling System. The most important findings were that (1) it is feasible to design the lead-cooled and salt-cooled reactor with the flexible conversion ratio (CR) in the range of CR=0 and CR=1 n a manner that achieves inherent reactor shutdown in unprotected accidents, (2) the salt-cooled reactor requires Lithium thermal Expansion Modules to overcme the inherent salt coolant's large positive coolant temperature reactivity coefficient, (3) the preferable salt for fast spectrum high power density cores is NaCl-Kcl-MgCl2 as opposed to fluoride salts due to its better themal-hydraulic and neutronic characteristics, and (4) both reactor, but attain power density 3 times smaller than that of the sodium-cooled reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

DISSOLUTION OF NEPTUNIUM OXIDE RESIDUES

This report describes the development of a dissolution flowsheet for neptunium (Np) oxide (NpO{sub 2}) residues (i.e., various NpO{sub 2} sources, HB-Line glovebox sweepings, and Savannah River National Laboratory (SRNL) thermogravimetric analysis samples). Samples of each type of materials proposed for processing were dissolved in a closed laboratory apparatus and the rate and total quantity of off-gas were measured. Samples of the off-gas were also analyzed. The quantity and type of solids remaining (when visible) were determined after post-dissolution filtration of the solution. Recommended conditions for dissolution of the NpO{sub 2} residues are: Solution Matrix and Loading: {approx}50 g Np/L (750 g Np in 15 L of dissolver solution), using 8 M nitric acid (HNO{sub 3}), 0.025 M potassium fluoride (KF) at greater than 100 C for at least 3 hours. Off-gas: Analysis of the off-gas indicated nitric oxide (NO), nitrogen dioxide (NO{sub 2}) and nitrous oxide (N{sub 2}O) as the only identified components. No hydrogen (H{sub 2}) was detected. The molar ratio of off-gas produced per mole of Np dissolved ranged from 0.25 to 0.4 moles of gas per mole of Np dissolved. A peak off-gas rate of {approx}0.1 scfm/kg bulk oxide was observed. Residual Solids: Pure NpO{sub 2} dissolved with little or no residue with the proposed flowsheet but the NpCo and both sweepings samples left visible solid residue after dissolution. For the NpCo and Part II Sweepings samples the residue amounted to {approx}1% of the initial material, but for the Part I Sweepings sample, the residue amounted to {approx}8 % of the initial material. These residues contained primarily aluminum (Al) and silicon (Si) compounds that did not completely dissolve under the flowsheet conditions. The residues from both sweepings samples contained minor amounts of plutonium (Pu) particles. Overall, the undissolved Np and Pu particles in the residues were a very small fraction of the total solids.

08 HYDROGEN↗

Platinum Group Metal Recycling Technology Development - Final Report

BASF Catalysts LLC, formerly Engelhard Corporation, has completed a project to recover Pt from PEM fuel cell membrane electrode assemblies. The project, which began in 2003, has met the project objective of an environmentally-friendly, cost-effective method for recovery of platinum without release of hydrogen fluoride. This has been achieved using a combination of milling, dispersion and acid leaching. 99% recovery of Pt was achieved, and this high yield can be scaled up using one vessel for a single leach and rinse. Leaching was been successfully achieved using a 10% solids level, double the original target. At this solids content, the reagent and utility costs represent ~0.35% of the Pt value of a lot, using very conservative assumptions. The main cost of the process is capital depreciation, followed by labor.

08 HYDROGEN↗

Engineering Evaluation of Proposed Alternative Salt Transfer Method for the Molten Salt Reactor Experiement for the Oak Ridge National Laboratory

This evaluation was performed by Pro2Serve in accordance with the Technical Specification for an Engineering Evaluation of the Proposed Alternative Salt Transfer Method for the Molten Salt Reactor Experiment at the Oak Ridge National Laboratory (BJC 2009b). The evaluators reviewed the Engineering Evaluation Work Plan for Molten Salt Reactor Experiment Residual Salt Removal, Oak Ridge National Laboratory, Oak Ridge, Tennessee (DOE 2008). The Work Plan (DOE 2008) involves installing a salt transfer probe and new drain line into the Fuel Drain Tanks and Fuel Flush Tank and connecting them to the new salt transfer line at the drain tank cell shield. The probe is to be inserted through the tank ball valve and the molten salt to the bottom of the tank. The tank would then be pressurized through the Reactive Gas Removal System to force the salt into the salt canisters. The Evaluation Team reviewed the work plan, interviewed site personnel, reviewed numerous documents on the Molten Salt Reactor (Sects. 7 and 8), and inspected the probes planned to be used for the transfer. Based on several concerns identified during this review, the team recommends not proceeding with the salt transfer via the proposed alternate salt transfer method. The major concerns identified during this evaluation are: (1) Structural integrity of the tanks - The main concern is with the corrosion that occurred during the fluorination phase of the uranium removal process. This may also apply to the salt transfer line for the Fuel Flush Tank. Corrosion Associated with Fluorination in the Oak Ridge National Laboratory Fluoride Volatility Process (Litman 1961) shows that this problem is significant. (2) Continued generation of Fluorine - Although the generation of Fluorine will be at a lower rate than experienced before the uranium removal, it will continue to be generated. This needs to be taken into consideration regardless of what actions are taken with the salt. (3) More than one phase of material - There are likely multiple phases of material in the salt (metal or compound), either suspended through the salt matrix, layered in the bottom of the tank, or both. These phases may contribute to plugging during any planned transfer. There is not enough data to know for sure. (4) Probe heat trace - The alternate transfer method does not include heat tracing of the bottom of the probe. There is a concern that this may cool the salt and other phases of materials present enough to block the flow of salt. (5) Stress-corrosion cracking - Additionally, there is a concern regarding moisture that may have been introduced into the tanks. Due to time constraints, this concern was not validated. However, if moisture was introduced into the tanks and not removed during heating the tanks before HF and F2 sparging, there would be an additional concern regarding the potential for stress-corrosion cracking of the tank walls.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

TASK 2.5.5 NATURAL EXPOSURE TESTING IN CALIFORNIA

Airborne particulate matter that settles on a roof can either reflect or absorb incoming solar radiation, dependent on the chemical content and size of the particles. These light scattering and absorption processes occur within a few microns of the surface, and can affect the solar reflectance of the roof. Wilkes et al. (2000) tested 24 different roof coatings on a low-slope test stand and observed about a 25% decrease in the solar reflectance of white-coated and aluminum-coated surfaces as the time of exposure increased; however, the decrease leveled off after 2 years. SPRI Inc. and its affiliates studied the effect of climatic exposure on the surface properties of white thermoplastic single-ply membranes and determined that membranes lose from 30 to 50% of their reflectance over 3 years (Miller et al. 2002). The CMRC and its affiliates AISI, NamZAC, MBMA, MCA and NCCA exposed unpainted and painted metal roofing on both steep- and low-slope test roofs and found that after 3 years, the painted polyvinylidene fluoride (PVDF) metal roofs lost less than 5% of their original reflectance (Miller et al. 2004). The results of the three different weathering studies are very interesting in terms of their solar reflectance after 3 years of exposure. The white thermoplastic membrane and white ceramic coating with white topcoat had original reflectance measures that were about 20 percentage points higher than the painted metal; however, after 3-years of field exposure the solar reflectance of the painted metal exceeds that of the thermoplastic membrane and equals that of the coating. The long-term loss of reflectance appears driven by the ability of the particulate matter to cling to the roof and resist being washed off by wind and or rain. Miller et al. (2002) discovered that aerosol deposition introduced biomass of complex microbial consortia onto the test roofs and the combination of contaminants and biomass accelerated the loss of solar reflectance for the thermoplastic membranes and the roof coatings. Airborne contaminants and biomass were also detected on the painted metal roofs; however, the loss of solar reflectance was less than 5% for the painted metal roofs. The chemistry of the PVDF paint resin system uses similar organic film bonding to that responsible for Teflon , making it extremely chemical resistant and dirt shedding. Miller and Rudolph (2003) found the PVDF painted metals maintained solar reflectance even after 30 years of climatic exposure. Therefore the reduction of roof reflectance is closely related to the composition of the roof and to the chemical profile of the contaminants soiling the roof. Contaminants collected from samples of roof products exposed at seven California weathering sites were analyzed for elements and carbons to characterize the chemical profile of the particles soiling each roof sample and to identify those elements that degrade or enhance solar reflectance. The losses in solar reflectance varied from site to site and also varied at a give site based on the color of the coupon. The least drop in reflectance was observed in the alpine climate of McArthur while the largest drop occurred in sites near urban development. Light color samples were soiled after just one year of exposure. The darker color coupons did not show the same seasonal variations in solar reflectance as observed for the lighter colors. However, after an additional year of exposure the samples at all sites regained most of their solar reflectance due to rain and/or wind washing. The loss of reflectance appears cyclical with the onset of seasons having more rainfall. Solar reflectance of the cool pigmented coupons always exceeded that of the conventional pigmented coupons. Climatic soiling did not cause the cool pigmented roof coupons to lose any more solar reflectance than their conventional pigmented counterparts. The effect of roof slope appears to have more of an effect on lighter color roofs whose solar reflectance exceeds at least 0.5 and visually shows the accumulation of airborne contaminants. The thermal emittance remained invariant with time and location and was therefore not affected by climatic soiling. A thin-film deposition model was developed based on first principles, which simulates light interaction with a soiled substrate. This model was used in combination with the measured data to determine the solar absorptance and reflectance of particulate matter at each of the sites calculated using least squares fitting routines. Principal Component Analysis was used to determine the most important combinations of chemicals correlated with changes in solar absorption. Linear regression helped extract an approximate correlation using chromium, iron and elemental carbon concentrations. It appears that chromium ranks first, iron ranks second, and elemental carbon ranks third in importance to soil absorptance in the data

09 BIOMASS FUELS↗

Glue Film Thickness Measurements by Spectral Reflectance

Spectral reflectance was used to determine the thickness of thin glue layers in a study of the effect of the glue on radiance and reflectance measurements of shocked-tin substrates attached to lithium fluoride windows. Measurements based on profilometry of the components were found to be inaccurate due to flatness variations and deformation of the tin substrate under pressure during the gluing process. The accuracy of the spectral reflectance measurements were estimated to be ±0.5 μm, which was sufficient to demonstrate a convincing correlation between glue thickness and shock-generated light.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DETECTION OF HF TOWARD PKS 1830–211, SEARCH FOR INTERSTELLAR H{sub 2}F{sup +}, AND LABORATORY STUDY OF H{sub 2}F{sup +} AND H{sub 2}Cl{sup +} DISSOCIATIVE RECOMBINATION

We report extragalactic observations of two fluorine-bearing species, hydrogen fluoride (HF) and fluoronium (H{sub 2}F{sup +}), in the z = 0.89 absorber in front of the lensed blazar PKS 1830−211 with the Atacama Large Millimeter/submillimeter Array. HF was detected toward both southwest and northeast images of the blazar, with column densities >3.4 × 10{sup 14} cm{sup −2} and 0.18 × 10{sup 14} cm{sup −2}, respectively. H{sub 2}F{sup +} was not detected, down to an upper limit (3σ) of 8.8 × 10{sup 11} cm{sup −2} and an abundance ratio of [H{sub 2}F{sup +}]/[HF] ⩽ 1/386. We also searched for H{sub 2}F{sup +} toward the Galactic sources NGC 6334 I and W51C, and toward Galactic center clouds with the Herschel HIFI spectrometer.{sup 6} The upper limit on the column density was derived to be 2.5 × 10{sup 11} cm{sup −2} in NGC 6334 I, which is 1/68 of that for H{sub 2}Cl{sup +}. In constrast, the ortho transition of H{sub 2}Cl{sup +} is detected toward PKS 1830–211. To understand the small abundance of interstellar H{sub 2}F{sup +}, we carried out laboratory experiments to determine the rate constants for the ion–electron recombination reaction by infrared time-resolved spectroscopy. The constants determined are k {sub e}(209 K) = (1.1±0.3)×10{sup −7} cm{sup 3} s{sup −1} and (0.46±0.05)×10{sup −7} cm{sup 3} s{sup −1} for H{sub 2}F{sup +} and H{sub 2}Cl{sup +}, respectively. The difference in the dissociative recombination rates between H{sub 2}F{sup +} and H{sub 2}Cl{sup +} by a factor ∼2 and the cosmic abundance ratio [F]/[Cl] ≈ 1/6 are not enough to explain the much smaller abundance of H{sub 2}F{sup +}. The difference in the formation mechanism of H{sub 2}F{sup +} and H{sub 2}Cl{sup +} in interstellar space would be a major factor in the small abundance of H{sub 2}F{sup +}.

79 ASTRONOMY AND ASTROPHYSICS↗

Impact of Biodiesel, Renewable Diesel, 1-Octanol, Dibutoxymethane, n-Undecane, Hexyl hexanoate and 2-Nonanone with Infrastructure Plastics as Blends with Diesel

In this work the volume and hardness were measured for thermoplastics and thermosetting resins with diesel containing up to 30% of the following blend stocks: biodiesel, renewable diesel, n-undecane, dibutoxymethane, 1-octanol, hexyl hexanoate, and 2-nonanone. Thermoplastics included polyphenylene sulfide (PPS), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), polyvinylidene fluoride (PVDF), polyoxymethylene (POM), polybutylene terephthalate (PBT), polypropylene (PP), high density polyethylene (HDPE), nylons, acetals, polyetherimide (PEI), polyetheretherketone (PEEK), a PET co-polymer, polyphthalamides (PPAs), polyarylamide (PARA) and ethylene tetrafluoroethylene (ETFE). Three thermosetting resins were also evaluated. The material specimens were exposed to the test fuels under ambient conditions for 16 weeks. In general, the volume and hardness of the specimens were relatively unaffected following exposure to the test fuels; however, n-undecane produced significant swelling in polypropylene and may not be suitable for use with this material. N-undecane, along with hexyl hexanoate and 2-nonanone also caused low levels of swelling in nylon, which was not significant enough to preclude the use of nylons in sealing applications with these fuels.

09 BIOMASS FUELS↗